Repair To Roof Treatment, Cgi Sheets / Ac Sheets In Roofing, Wall Panelling, False Ceiling In Technical Area At Air Force Station Pathannkot , pathankot-Punjab

Military Engineer Services-MES has published Repair To Roof Treatment, Cgi Sheets / Ac Sheets In Roofing, Wall Panelling, False Ceiling In Technical Area At Air Force Station Pathannkot . Submission Date for this Tender is 03-09-2022. Shed Construction Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

33432739
Corrigendum : Repair To Roof Treatment, Cgi Sheets / Ac Sheets In Roofing, Wall Panelling, False Ceiling In Technical Area At Air Force Station Pathannkot
Open Tender
Indian
Punjab
pathankot
03-09-2022

Tender Details

Repair To Roof Treatment, Cgi Sheets / Ac Sheets In Roofing, Wall Panelling, False Ceiling In Technical Area At Air Force Station Pathannkot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work : REPAIR TO ROOF TREATMENT, CGI SHEETS/ AC SHEETS IN ROOFING, WALL PANELLING, FALSE CEILING IN TECHNICAL AREA AT AIR FORCE STATION PATHANNKOT
Sl. No. Item Description
1Removing old tar felt, all loose dirt,old roof tiles,cleaning the concrete surface including removal & cleaning of vegetation, fungus,mass small trees etc from the roof top with wire brush, removing the strips of lightening conductor including refixing the same after repair workand applying neat cement slurry @ 1.5Kg/Sqm complete all as specified and directed by Engineer-in-Charge.
2Material and labour for 15mm thick cement plaster in cement mortar 1:4 over concrete surface on top of roof finished even and smooth without using extra cement mixed with water proofing compound pidi proof LW @ 200ml per 50Kg cement as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge (WPC shall be measured and paid separately).
3Supply only liquid water proofing compound pidilite LW complete all as specified and directed by Engineer-in-Charge.
4Material and labour for providing APP modified water proofingmembrane with non woven polyster super thermally laid with overlaps, bonded with hot blown bitumen85/25 @ 1.20Kg/Sqm, over a coat of manufacturer"s primer 0.3 ltr/Sqm on the prepared surface of plaster,end overlaps shall not be less than 150mm and side overlaps 75mm . APP modified water proofing membrane shuold be five layered 3mm thick and minimum weight 3kg per square metre complete all as specified and as directed by Engineer-in-Charge.
5Taking down cementplaster of any description on brick or stone walls, including raking out joints, hacking for keys, scubbing down with water etc and complete all as specified and directed by Engineer-in-Charge.
6Material and labour for 15mm thick cemet plalster in cement mortar 1:4 over concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
7Rendering dubbing coat over damaged irregular surface of chajjas, roof projection ceilings facia etc average 15mm thick in cement mortar 1:4 over cement slurry coatbthick @ 3 Kg/Sqm making the surface even followed by 5mm thick rendering in cement mortar 1:3 furnished even & smooth including applying two coats of exterior emulsion paint with one coat of coloured primer in camouflage pattern (four) or more shades including making of drip course as required complete including roughening surface of old concrete by picking sweeping clean and washing with water complete all as specified and directed by Engineer-in-Charge.
8Dismantling framed wooden trusses span n exc 10 m of any description and in any position complete all as specified and directed by Engineer-in-Charge.
9Dismantling timber scantling in fillets, rails, posts, rafters, purlins etc. under 40 Sqcm in section framed work complete all as specified and directed by Engineer-in-Charge.
10Supply and fixing for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleatsconforming to Fe 410-W (Gde-E 250) quality-B etc complete all as specified and directed by Engineer-in-Charge.
11Supply and fixing rolled MS section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates confirming to Fe 410-W quality B complete all as specified and directed by Engineer-in-Charge.
12Supply and fixing for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,with riveted, bolted or welded attachment conforming to Fe 410-W (Gde-E 250) quality-A etc complete all as specified and directed by Engineer-in-Charge.
13Refixing and erection of old MS rolled section of any thickness/size as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed by Engineer-in-Charge.
14Refixingold any thickness/size of MS works as in wind tie for roof flat iron fillet for securing wire mesh etc and similar worksincluding drilling holes as required complete all as specified and directed by Engineer-in-Charge.
15Dismantling AC corrugated or semi corrugated sheets in wall cladding or roof coverings including ridges and make good of aluminium earthing strips after fixing of sheets complete all as specified and directed by Engineer-in-Charge.
16Dismantling GI/PGI corrugated or semi corrugated sheets in wall cladding or roof coverings including ridges and make good of aluminium earthing strips after fixing of sheets complete all as specified and directed by Engineer-in-Charge.
17Supply and fixing for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
18Supply and fixingin repair pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
19Supply and fixing forin repair 0.63mm thick galvanised with grade of zinc coating 275gm/sqm mild steel sheeting (with grade of zinc coating 275 Gm/sqm) with two corrugation side lap fixed with L- type or cranked hook bolts and washer in roof, wall etc bent to curve complete all as specified and directed by Engineer-in-Charge.
20Taking down earthing arrester including stripand refixing same postion after fixing of any type roof sheet complete all as specified and directed by Engineer-in-Charge.
21Preparing new steel surfaces of any description over 10 cm in width or girth and applying two coats synthetic enamel paint of camouflage pattern de-galvanizngwith one coat of "H" primer in four or more shades complete all as specified and directed by Engineer-in-Charge including necessary scaffolding and other safety arrangement to work at any height at site if required.
22Refixingold any thickness Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. complete all as specified and directed by Engineer-in-Charge.
23Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
24Taking down carefully (copper/aluminium) point wiring for ceiling fan/light fitting in ceiling and refixing the same in any position including replacing damaged material and lowering/rising the rod of ceiling fan if required complete all as specified and directed by Engineer-in-Charge.
25Taking down carefully switch boards of any size and any description and boxes of such types on wall and refixing at same place duly modification over PVC panelling including necessary screws, washers, replacement of damage switches etc. complete all as specified and directed by Engineer-in-Charge.
26Supply and fixing position suspended false ceiling system using T-grid suspended ceiling grid system . The size of grid shall be 600x600mm with GI frame work main runner 38x24x3600mm, cross tee 25x24x600mm/ 25x 24 x 1200mm and wall angle 24x24x2540mm( thickness of the materail of 0.30mm). using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in the drop texture as per IS-2095, part-I 1996, fixed in the grid of T-grid suspended ceiling grid system duly susupended by 4mm dia GI bar hanged from the purlins of the roof with butter fly clipscomplete all as specified and directed by Engineer-in-Charge.
27Demolition brick work built in cement mortar of any description complete all as specified and directed by Engineer-in-Charge.
28Material and labour brick work with sub class "B" modular brick straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
29Preparing new steel surfaces of any description exc 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed by Engineer-in-Charge.
30Preparation of steel surfaces of any description, not otherwise described, not exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
31Dismantling water tankscapacity of tank exc 500 ltr and n exc 1000 ltr and removing to store etc complete all as specified and directed by Engineer-in-Charge.
32Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top)three layers hoisted andfixed in position complete andall as specified and as directed by Engineer-in-Charge including dismantling existing water tank and removing from site of any capacity.
33Refixingold 500 Litre capacity Rotational moulded polyethylene water storage tank fixed in position complete all as specified and directed by Engineer-in-Charge.
34Supply and fixing in repairs 20 mm bore float valve of high pressure PTMT with epoxy coated aluminuim rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
35Taking up or down GI tubing 25mm bore including cleaning for refixing complete all as specified and directed by Engr-in-Charge
36Taking up or down GI tubing 20mm bore including cleaning for refixing complete all as specified and directed by Engr-in-Charge.
37Supply and fixing 25 mm tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floorcomplete all as specified and directed by Engr-in-Charge
38Refixingold steel tubing and connectionsof 25mm dia in new or old position (wall, ceiling, floors etc.) complete all as specified and directed by Engineer-in-Charge.
39Supply and fixing 20 mm tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed by Engr-in-Charge.
40Refixingold steel tubing and connectionsof 20mm dia in new or old position (wall, ceiling, floors etc.) complete all as specified and directed by Engineer-in-Charge.
41Dismantling of Rain waterpipeof AC or PVCor any typefixed to wallof wall claddingwithMSstrapof any diameter complete all as specified and directed by Engineer-in-Charge.
42Supply and fixing150 mm diaPVC (SWR) pipe singlesocketed in any length with rubberring joint fixedto wall /wall cladding complete all as specified and directed by Engineer-in-Charge.
43Supply and fixingof 150mm diaPVC(SWR)bends as a shoes of rain water complete all as specified and directed by Engineer-in-Charge.
44Supply and fixingofbands , strapssupports of staysforrain water pipe, strap forvalley gutter and oneextraangle welded toexistingwindow frametofix thetwo windowpanes in onefixed type window .Similar smallarticle confirming to FE -290-Gde -E -165 complete all as specified and directed by Engineer-in-Charge.
45Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed by Engineer-in-Charge.
46Supply and fixing for posts and strutsincluding cutting tops to shape as directed, drilling holes, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
47Supply and fixing for 4mm mild steel wire, galvanised class 3, inany postion including straining and fixing tosteel posts and/or tostraining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified and directed by Engineer-in-Charge.
48Material and labour for re-securing and restraining GI Wireincluding making goodcomplete all as specified and directed by Engineer-in-Charge.
49Material and labour for cement concrete type B-2 (1:2:4) using 40 mm graded crushed stone aggregate complete all as specified and directed by Engineer-in-Charge.
50Demolition of cement concrete of any description and in any position not otherwise specifically complete all as specified and directed by Engineer-in-Charge.
51Material and labour for providing PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate including necessary formwork as in cills, steps, seismic & other similar bands, string course, lacing course, parapets & railing up to 60cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles & throating complete all as specified and directed by Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail