Madhyanchal Vidut Vitran Nigam Limited has published Development Of Distribution Infrastructure At [ Raebareilly, Sitapur, Unnao ] District Of Uttar Pradesh Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Lt Line With Xlpe Armoured Cable In High Loss Area 2 Rout. Submission Date for this Tender is 31-08-2022. MS Flat Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Aug-2022 | Pre bid meeting | Other | 20-08-2022 |
2 | 17-Aug-2022 | Date extension | Date | 31-08-2022 |
3 | 26-Aug-2022 | pre bid query reply | Other | 31-08-2022 |
Sl. No. | Item Description |
1 | LT Line with XLPE Armoured Cable in high loss area |
2 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
3 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
4 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
5 | 13 M long steel Tubular poles with welded steel base plate of Designation 410 SP 72 |
6 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
7 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
8 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) |
9 | Red oxide paint as per TS |
10 | Aluminium paint as per TS |
11 | 1.1 kV Single Core 25sqmm XLPE armoured cable (1Cx25 sqmm) |
12 | 1.1 kV Single Core 50sqmm XLPE armoured cable (1Cx50 sqmm) |
13 | 1.1 kV Single Core 95sqmm XLPE armoured cable (1Cx95 sqmm) |
14 | 1.1 kV Single Core 120sqmm XLPE armoured cable (1Cx120 sqmm) |
15 | LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg)with Nuts and bolts |
16 | LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts |
17 | C-Clamp with Nut & bolts |
18 | LT shakle insulator |
19 | Distribution tie for shakle insulator |
20 | Mid span joint 25sqmm |
21 | Mid span joint 50sqmm |
22 | Mid span joint 95sqmm |
23 | Mid span joint 120sqmm |
24 | Three phase 20SWG CRCA MS sheet by deep drawn/sheet bending processPole top distribution box with calmps (50x6 mm) and nut & bolts and lugs suitable for 25 sqmm armoured cable |
25 | Three Single phase 20SWG CRCA MS sheet by deep drawn/sheet bending processPole top distribution box with calmps (50x6 mm) and nut & bolts and lugs suitable for 50 sqmm armoured cable |
26 | Three phase 20SWG CRCA MS sheet by deep drawn/sheet bending processPole top distribution box with calmps (50x6 mm) and nut & bolts and lugs suitable for 95 sqmm armoured cable |
27 | Three phase 20SWG CRCA MS sheet by deep drawn/sheet bending processPole top distribution box with calmps (50x6 mm) and nut & bolts and lugs suitable for 120 sqmm armoured cable |
28 | 1x2.5 sqmm PVC insulated Aluminium cable for energising the street light. |
29 | 5A, 240 V, ISI marked Piano type switch |
30 | Earthing of pole by earthing coil (with Salt & Charcoal) |
31 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
32 | Removal of existing material and shifting to MVVNL store |
33 | Armoured cabling in consumer service connection |
34 | Single phase (2CX4 sqmm) PVC Armoured Service Cable |
35 | Single phase (2CX6 sqmm) PVC Armoured Service Cable |
36 | Three phase (4CX16 sqmm) PVC Armoured Service Cable |
37 | Supporting GI Wire 10 SWG (As per site requirements) |
38 | 20 SWG GI wire for binding |
39 | Arrangement for holding the service cable at pole (MS flat 50x8 mm, 3.0 kg) with nuts and bolts |
40 | Arrangement for holding the service cable at pole (MS flat 75x8 mm, 4.6 kg) with nuts and bolts |
41 | MS angle 50X50X5 mm for holding the service cable at consumer premises (length 1000 mm) |
42 | Polycarbonated box for single phase consumer |
43 | Polycarbonated box for three phase consumer |
44 | Removal of existing material and shifting to MVVNL store |
45 | Replacement of Bare conductors/Damage cable with AB cables |
46 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
47 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
48 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
49 | 13 M long steel Tubular poles with welded steel base plate of Designation 410 SP 72 |
50 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
51 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
52 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) |
53 | Red oxide paint as per TS |
54 | Aluminium paint as per TS |
55 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with calmps (40x3 mm) and nut & bolts |
56 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with calmps (40x3 mm) and nut & bolts |
57 | 2Cx25 sqmm XLPE aluminium conductor cable for single phase DB incomer |
58 | 4Cx35 sqmm XLPE aluminium conductor cable for Three phase DB incomer |
59 | Earthing of pole by earthing coil (with Salt & Charcoal) |
60 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
61 | Aerial Bunched XLPE Cable 1X25 (Ph) + 1X25 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
62 | Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
63 | Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
64 | Aerial Bunched XLPE Cable 3X120 (Ph) + 1X95 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
65 | Aerial Bunched XLPE Cable 3X150 (Ph) + 1X120 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
66 | LT pole clamp (50x8mm) (2.56 kg) with Nut and bolts |
67 | LT Eye hook |
68 | suspension clamp |
69 | Dead end clamp |
70 | Insulation Piercing connectors/Connector type-I (AB cable to AB cable) |
71 | Insulation Piercing connectors type-II (AB cable to Service cable) |
72 | Removal of existing material and shifting to MVVNL store |
73 | 1x2.5 sqmm PVC Al Cable for energising the street light |
74 | End cap for AB cable 25 sqmm |
75 | End cap for AB cable 50 sqmm |
76 | End cap for AB cable 95 sqmm |
77 | End cap for AB cable 120 sqmm |
78 | End cap for AB cable 150 sqmm |
79 | PG clamp for messanger wire |
80 | Provision of AB cables for extra circuits at existing DTR |
81 | Overhead LT for Extra circuit at existing DTR |
82 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
83 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
84 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
85 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
86 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
87 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) |
88 | Red oxide paint as per TS |
89 | Aluminium paint as per TS |
90 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with calmps (40x3 mm) and nut & bolts |
91 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with calmps (40x3 mm) and nut & bolts |
92 | 2Cx25 sqmm XLPE aluminium conductor cable for single phase DB incomer |
93 | 4Cx35 sqmm XLPE aluminium conductor cable for Three phase DB incomer |
94 | Earthing of pole by earthing coil (with Salt & Charcoal) |
95 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
96 | Aerial Bunched XLPE Cable 1X25 (Ph) + 1X25 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
97 | Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
98 | Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
99 | Aerial Bunched XLPE Cable 3X120 (Ph) + 1X95 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
100 | Aerial Bunched XLPE Cable 3X150 (Ph) + 1X120 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
101 | LT pole clamp (50x8mm) (2.56 kg) with Nut and bolts |
102 | LT Eye hook |
103 | suspension clamp |
104 | Dead end clamp |
105 | Insulation Piercing connectors/Connector type-I (AB cable to AB cable) |
106 | Insulation Piercing connectors type-II (AB cable to Service cable) |
107 | 1x2.5 sqmm PVC Al Cable for energising the street light |
108 | End cap for AB cable 25 sqmm |
109 | End cap for AB cable 50 sqmm |
110 | End cap for AB cable 95 sqmm |
111 | End cap for AB cable 120 sqmm |
112 | End cap for AB cable 150 sqmm |
113 | PG clamp for messanger wire |
114 | Feeder Segregation |
115 | Overhead 11 kV New feeder |
116 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
117 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
118 | 9 meter long /400 KG PCC Poles (PCC Pole as per state practice) |
119 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
120 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) |
121 | Stone pad for supports as per scope of works & drawing (450x450x75 mm ) |
122 | 11KV V-Type Cross-arm (M.S Channel 75X40x6mm) welded with MS angel (50x50x6) (weight-10.37 kg) with bolts and nuts |
123 | Cross arm holding clamps (MS Flat-50x8 mm) (weight-1.33 kg) with bolts and nuts |
124 | F- Bracket MS flat (50x8 mm) (weight- 1.56 kg) with nut and bolts |
125 | Cut point top channel (100x50x6 mm) of length 230 mm along with nut & bolts |
126 | Cut point bottom channel (100x50x6 mm) of length 1150 mm along with nut & bolts |
127 | Tapping horizontal cross arm (100x50x6 mm) of length 1020 mm along with calmps (50x8) and nut and bolts |
128 | Tapping top channel (100x50x6 mm) of length 256 mm along with calmps(50x8) and nut and bolts |
129 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
130 | Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts |
131 | Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts |
132 | Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts |
133 | Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts |
134 | Fish plate for jumpering |
135 | 6/2.59 + 1/2.59 mm (30 sqmm Al. Area) ACSR weasel conductors |
136 | 6/3.35 + 1/3.35 mm (50 sqmm Al. Area) ACSR Rabbit conductors |
137 | 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog conductor |
138 | PG clamp for weasel conductor |
139 | PG clamp for Rabbit conductor |
140 | PG clamp for dog conductor |
141 | Distribution tie for pin insulator |
142 | Armoured Rod with Ferrule |
143 | Jointing sleeves Aluminium |
144 | Aluminium binding wire and tape |
145 | 11 KV polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings |
146 | 11 KV Polymer Pin Insulators 5 KN with nuts |
147 | Earthing of pole by earthing coil (with Salt & Charcoal) |
148 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
149 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
150 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
151 | Numbering of pole of each support as per Technical specification and scope of work |
152 | Underground 11 kV New feeder |
153 | Radar route survey for route profile of any utility cables,pipes etc. along the route as per TS and scope of work |
154 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
155 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
156 | Red oxide paint as per TS |
157 | Aluminium paint as per TS |
158 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
159 | Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts |
160 | Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts |
161 | Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts |
162 | Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts |
163 | Fish plate for jumpering |
164 | 11 KV Polymer Pin Insulators 5 KN with nuts |
165 | Heat Shrinkable Jointing kit indoor for 11 KV 3C×185 sq.mm. XLPE Cable |
166 | Heat Shrinkable Jointing kit indoor for 11 KV 3C×120 sq.mm. XLPE Cable |
167 | Heat Shrinkable Jointing kit outdoor for 11 KV 3C×185 sq.mm. XLPE Cable |
168 | Heat Shrinkable Jointing kit outdoor for 11 KV 3C×120 sq.mm. XLPE Cable |
169 | Heat Shrinkable Cable Jointing kit straight through for 11 kv 3C×185 sq.mm. XLPE Cable |
170 | Heat Shrinkable Cable Jointing kit straight through for 11 kv 3C×120 sq.mm. XLPE Cable |
171 | Road Restoration Chages for Pucca Road Crossing |
172 | Road Restoration chages for Kucchha Road Crossing |
173 | Supply and Placing of Pre-cast Concrete Manhole Chambers of size 900mm x 900mm Internal Dimension x 800mm Height & 100mm wall thickness (Heavy Duty) with Concrete Cover of 100mm thickness in the specified locations in the trench. |
174 | Supply & Erection of 11 kV Single core 95 sqmm XLPE Aluminium cable for jumpering |
175 | Supply & Erection of Aluminum lugs -185 Sq.mm. |
176 | Supply & Erection of Aluminum lugs -120 Sq.mm. |
177 | Supply & Erection of Cable warning tape |
178 | Fixing of Cable marker on cable route and inscription of feeder name and voltage on cable marker |
179 | Supply of 11 KV 3C×120 sqmm XLPE Cable |
180 | Supply of 11 KV 3C×185 sqmm XLPE Cable |
181 | Earth digging, laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 120/185 Sqmm XLPE power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per TS/approved drawing. |
182 | Laying of 11 KV 3Cx185 sq mm XLPE Singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (all the material) |
183 | Laying of 11 KV 3x185 sq mm XLPE twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick,sand,stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. The ferruling of cable also include in this work (all the material) |
184 | Laying of 11 KV 3Cx120 sq mm XLPE Singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (all the material |
185 | Laying of 11 KV 3x120 sq mm XLPE twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick,sand,stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. The ferruling of cable also include in this work (all the material) |
186 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 120/185 Sqmm XLPE power cable undergroundusing HDPE pipecomplete in all respect along with all accessories, earthing etc. and as per TS/approved drawing . |
187 | Laying of 11 KV 3C×185 sqmm XLPE Cable |
188 | Laying of 11 KV 3×120 sqmm XLPE Cable |
189 | Pipe (HDPE 160 mm dia) for Cable Laying |
190 | Earth digging by horizontal Directional Drilling(HDD)method,Laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 120/185 Sqmm XLPE power cable undergroundwithout HDPE Pipes in all respect along with all accessories, earthing etc. and as per TS/approved drawing . |
191 | Laying of 11 KV 3C×185 sqmm XLPE Cable |
192 | Laying of 11 KV 3×120 sqmm XLPE Cable |
193 | Hoisting of following sizes of11 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6"" dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.(all the material shall be arranged by contractor) |
194 | Testing & commissioning of 11 KV grade 3-core 185 Sqmm XLPE power underground cable |
195 | Testing & commissioning of 11 KV grade 3-core 120 Sqmm XLPE power underground cable |
196 | Earthing of pole by earthing coil (with Salt & Charcoal) |
197 | 8 SWG GI wire for pole, DB earthing with GI nuts, bolts & washers |
198 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
199 | Anti-climbing device-3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS |
200 | Numbering of pole of each support as per Technical specification and scope of work |
201 | Railway Crossing |
202 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
203 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
204 | Red oxide paint as per TS |
205 | Aluminium paint as per TS |
206 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
207 | Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts |
208 | Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts |
209 | Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts |
210 | Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts |
211 | Fish plate for jumpering |
212 | 11 KV Polymer Pin Insulators 5 KN with nuts |
213 | 9 kV, 10 kA station class LA |
214 | Supply of 11 KV 3C×185 sqmm XLPE Cable |
215 | Supply of 33 KV 3C×300 sqmm XLPE Cable |
216 | Heat Shrinkable Jointing kit outdoor for 11 KV 3C×185 sq.mm. XLPE Cable |
217 | Heat Shrinkable Jointing kit outdoor for 33 KV 3C×300 sq.mm. XLPE Cable |
218 | Hoisting of following sizes of11 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6"" dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.(all the material shall be arranged by contractor) |
219 | 11 KV or 33 kV LINEFORUNDER GROUND RAILWAY CROSSING BY 2 Nos (INCLUDING ONE SPARE) 3Cx185 or 3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS,LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. |
220 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection of 11 KV grade 3-core 185 Sqmm XLPE power cable underground as per TS/approved drawing . |
221 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection of 33 KV grade 3-core 300 Sqmm XLPE power cable underground as per TS/approved drawing . |
222 | Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 11 KV XLPE cables including cost of Bricks, sand, clamps etc. |
223 | Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 33 KV XLPE cables including cost of Bricks, sand, clamps etc. |
224 | G.I. Pipe (6" dia.) forlaying UG below the Railway track (minimum 3 meter) by HDD Method. |
225 | Supply & Erection of 11 kV Single core 95 sqmm XLPE Aluminium cable for jumpering |
226 | Supply & Erection of 33 kV Single core 120 sqmm XLPE Aluminium cable for jumpering |
227 | Supply & Erection of Aluminum lugs -185 Sq.mm. |
228 | Supply & Erection of Aluminum lugs -300 Sq.mm. |
229 | Railway crossing documentation and approval fee etc. |
230 | Testing & commissioning of 11 KV grade 3-core 185 Sqmm XLPE power underground cable |
231 | Testing & commissioning of 33 kV 3-core 300 Sqmm XLPE power underground cable |
232 | Earthing of pole by earthing coil (with Salt & Charcoal) |
233 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
234 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
235 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
236 | Numbering of pole of each support as per Technical specification and scope of work |
237 | National highway crossing |
238 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
239 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
240 | Red oxide paint as per TS |
241 | Aluminium paint as per TS |
242 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
243 | Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts |
244 | Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts |
245 | Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts |
246 | Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts |
247 | Fish plate for jumpering |
248 | 11 KV Polymer Pin Insulators 5 KN with nuts |
249 | 9 kV, 10 kA station class LA |
250 | Supply & Erection of 11 kV Single core 95 sqmm XLPE Aluminium cable for jumpering |
251 | Supply & Erection of 33 kV Single core 120 sqmm XLPE Aluminium cable for jumpering |
252 | Supply & Erection of Aluminum lugs -185 Sq.mm. |
253 | Supply & Erection of Aluminum lugs -300 Sq.mm. |
254 | Supply of 11 KV 3C×185 sqmm XLPE Cable |
255 | Supply of 33 KV 3C×300 sqmm XLPE Cable |
256 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 185 or 300 Sqmm XLPE power cable underground as per TS/approved drawing . |
257 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection of 11 KV grade 3-core 185 Sqmm XLPE power cable underground as per TS/approved drawing . |
258 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection of 33 KV grade 3-core 300 Sqmm XLPE power cable underground as per TS/approved drawing . |
259 | Pipe (HDPE 160 mm dia) for Cable Laying at road crossings |
260 | Heat Shrinkable Jointing kit outdoor for 11 KV 3C×185 sq.mm. XLPE Cable |
261 | Heat Shrinkable Jointing kit outdoor for 11 KV 3C×300 sq.mm. XLPE Cable |
262 | Hoisting of following sizes of11 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6"" dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.(all the material shall be arranged by contractor) |
263 | Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 11 KV XLPE cables including cost of Bricks, sand, clamps etc. |
264 | Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 33 KV XLPE cables including cost of Bricks, sand, clamps etc. |
265 | Testing & commissioning of 11 KV grade 3-core 185 Sqmm XLPE power underground cable |
266 | Testing & commissioning of 33 KV 3-core 300 Sqmm XLPE power underground cable |
267 | Earthing of pole by earthing coil (with Salt & Charcoal) |
268 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
269 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
270 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
271 | Numbering of pole of each support as per Technical specification and scope of work |
272 | Supply & Installation of 11KV VCB Switchgear panel outgoing for extra feeder under feeder segregation/bifurcartion works. |
273 | control room extension |
274 | Excavation in foundation in ordinary soil (Loam day or sand) including lift upto 1.5 mtr. And lead upto 30 m and including filling watering and ramming of excavated earth into the building and sides of the foundation trenches or in to the plinth and directed by the engineer-in-charge upto a distance of 30 m from the foundation |
275 | Concrete with 4 cm.gauge 1st class brick ballast (class 150) coarse sand (F.M.1.8 to 2.5) and cement in proportion of 10:5:1 in foundation and under floors including supply of all materials labour and T&P etc. required for propoer complrtion of work. |
276 | 1st class brick work in 1:6 cement & coarse sand (F.M.1.8 to 2.5) morter in foundation & plinth including supply of all materials, labour and T&P etc. required for propoer complrtion of work. |
277 | 1st class brick (class 150)work in 1:6 cement & coarse sand (FM 1.8 to 2.50) morter but in supper structure but for wall of one & half brick thick including supply of all materials , labour T&P etc required for propoer completion of work. |
278 | st class brick (class 150) work in 1:6 cement & coarse sand (FM1.8 to 2.50) morter but in supper structure but for wall of one brick thick including supply of all materials , labour T&P etc required for proper completion of work. |
279 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in over all rate) wrought to required shape as necessary I/C bending for proper completion of the work & I/C supply of steel its wastege shall be measured stee! shall not be supplied by the department. |
280 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks roof work gates etc. wrought to required form including holes riveting or welding where necessary and also including supply of steel bolts nuts wastage etc.and their fixing required for proper completion of the work (steel is not supplies by the department) |
281 | R.C.C. work with cement approved coarse sand (P.M. 1.8 to 2.5)and 2 Cm gauge graded approved hard stone ballast in proportion 1:2:4 in lintels of doors & windows excluding supply of reinforcement and its bending but including its fixing & binding the same with 24 BWG G.I. binding wire and including necessary centring & shuttering etc. and also including cost of all materials, labour and T&P etc. required for proper completion of the work. |
282 | R.c.c. work with cement approved coarse sand (P.M. 1.8 to 2.5)and 2 Cm gauge graded approved hard stone ballast in proportion 1:1:5:3 for slab excluding supply of reinforcement and its bending but including its fixing & binding the same with 24 BWG G.I binding wire and I/C necessary centering & shuttering etc. and also I/C cost of all materials, labour and T&P etc. required for proper completion of the work. |
283 | 12 MM thick plaster with cement morter consisting of 1 aart: Sparts of approved coarse sand on fare surface "ncluding supply of all materials, labour T&P etc. required for proper completion of work. |
284 | Supply & fixing fan hooks 16 mm dia 200 mm long complete. |
285 | P/F glass strip of 40 mm depth in joints of floor and skirting at the time of laying, floors flush with floor level ncluding labour. Tools and plants etc. complete. |
286 | 40 mm thick 1:2:4 floor without base concrete floor with cement, approved coarse sand &2 cm. graded approved stone ballast (shingle for bareily) laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and giving them a uniform finish including supply of all labour and T&P etc required for proper completion of work. |
287 | White washing three coats of new surface including cost of all materials, labour and T&P etc. required for proper completion of the work exept cost of angle iron and flat. |
288 | One priming coat and two coats of dry distemper castle or equivalent make on new surface including cost of all materials, labour and T&P etc. required for proper completion of the work. |
289 | Finishing walls with water proof cement paint of approved make and quality over new work with three coats to give an even shade including supply of all materials, labour and T&P etc.required for proper completion of the work. |
290 | Writing point for light with 1.5 sq.mm. FRPVC insulated multistrand single core copper conductor cable in surface conduit pipe, complete with copper earth continuity wire, piano type switch & ceiling rose/angle/button holder on 3mm thick phenolic aminated backelite-sheet etc. Complete in all respects, as directed including matching colour wash. |
291 | Wiring point for fan/fresh air fan (light duty exhaust fan) n PVC conduit with 1.5 sq.mm. FR PVC insulted multistrand copper condctor cable as earth wire drawn nside the conduit. |
292 | S/F Batten/Angle Holder of approved quality complete n all respect. |
293 | Painting or varnishing on new iron work in small areas or new wood work with one coat of ready mixed priming paint and two coats of approved superior quality ready mixed paint (Luxol) or equivalent brand or varnish I/C supply of all materials, labour T&P etc. required for proper completion of work.Paint to be used should conform I.S.103-1950 |
294 | Dismantling brick work or stone work in time or cement mortar and including stacking of materials as directed by E/l within distance of 60mtr. |
295 | Dismantling Existing plaster including disposal of refuse as directed by E/l within a distance of 60 mtr. |
296 | Dismantling C.C brick or brick or granolithic floors including base concrete and including stacking of dismantled material as directed by E/l within a distance of 60 mtr. |
297 | Road crossings on 9 meter and 11 meter Poles |
298 | 9 meter long /400 KG PCC Poles (PCC Pole as per state practice) |
299 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
300 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
301 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
302 | Stone pad for supports as per scope of works & drawing (450x450x75 mm ) |
303 | Red oxide paint as per TS |
304 | Aluminium paint as per TS |
305 | V-cross arm supporting channel (100x50x6 mm), 3000mm long with holding clamps ,bolts and nuts. |
306 | 11KV V-Type Cross-arm (M.S Channel 75X40x6mm) welded with MS angel (50x50x6) (weight-10.37 kg) with bolts and nuts |
307 | 11KV Bridling V-Type Cross-arm (M.S Channel 75X40x6mm) welded with MS angel (50x50x6) (weight- 10.5 kg) with bolts and nuts |
308 | Guarding Cross arm (75x40x6 mm) 2210 mm long with eye bolts (16mm dia) |
309 | Back clamp for guarding cross arm (50x8 mm) (weight- 1.15 kg)with nut & bolts. |
310 | Cross arm holding clamps (MS Flat-50x8 mm) (weight-1.33 kg) with bolts and nuts |
311 | F- Bracket MS flat (50x8 mm) (weight- 1.56 kg) with nut and bolts |
312 | Distribution tie for pin insulator |
313 | 11 KV Polymer Pin Insulators 5 KN with nuts |
314 | 6 SWG GI wire along the span |
315 | 8 SWG GI wire across the span |
316 | 12 SWG GI wire for binding |
317 | Earthing of pole by earthing coil (with Salt & Charcoal) |
318 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
319 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
320 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
321 | Numbering of pole of each support as per Technical specification and scope of work |
322 | Relocation of 11/.433 KV 3Ph Distribution Transformer |
323 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
324 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
325 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) |
326 | Shifting of Distribution transformer and ALL fabricated items and other allied materials |
327 | Distribution transformer for segregated feeders |
328 | 9 meter long /400 KG PCC Poles (PCC Pole as per state practice) |
329 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
330 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
331 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
332 | Stone pad for supports as per scope of works & drawing (450x450x75 mm ) |
333 | Red oxide paint as per TS |
334 | Aluminium paint as per TS |
335 | Transformer Top channel (100x50x6mm) 2800 mm long with nuts & bolts |
336 | AB switch mounting channel (100x50x6mm) 2800 mm long with nuts & bolts |
337 | Back clamp for AB switch mounting channel(50x8mm)- (weight-1.8 kg) with nuts & bolts |
338 | DO fuse mounting channel (75x40x6mm) 2800 mm long with nuts & bolts |
339 | Back clamp for DO fuse mounting channel(50x8mm)- (weight-1.9 kg) with nuts & bolts |
340 | Transformer mounting channel (100x50x6mm) 2800 mm with nuts & bolts |
341 | Transformer mounting channel support (50x50x6mm) 500 mm long with Nuts & bolts. |
342 | Transformer Belting angle (50x50x6mm) 2800 mm longwith nuts & bolts |
343 | Transformer Belting angle support (35x35x6 mm)500 mm long with nuts & bolts |
344 | 11 KV polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings |
345 | 11 KV Polymer Pin Insulators 5 KN with nuts |
346 | 11/0.230 kV Distribution Transformer 16 KVA single Phase aluminum wound DTR |
347 | 11/0.4 kV Distribution Transformer 25 KVA Three Phase aluminum wound DTR |
348 | 11/0.4 kV Distribution Transformer 63 KVA Three Phase aluminum wound DTR |
349 | 11/0.4 kV Distribution Transformer 100 KVA Three Phase aluminum wound DTR |
350 | 11/0.4 kV Distribution Transformer 250 KVA Three Phase copper wound DTR |
351 | ACSR weasel counductor for Jumpering |
352 | Bimetallic connector for HT & LT side of the transformer |
353 | T-Clamp & PG clamp for jumpering |
354 | LT Distribution box polyester sheet moulding compound (SMC) for 16 kVA Distribution transformer with arrangement of suitable bus-bars and MCCB"s as per scope of works of SBD |
355 | LT Distribution box polyester sheet moulding compound (SMC) for 25 kVA Distribution transformer with arrangement of suitable bus-bars & MCCB"s as per scope of works of SBD |
356 | LT Distribution box polyester sheet moulding compound (SMC) for 63 kVA Distribution transformer with arrangement of suitable bus-bars & MCCB"s as per scope of works of SBD |
357 | LT Distribution box polyester sheet moulding compound (SMC) for 100 kVA Distribution transformer with arrangement of suitable bus-bars & MCCB"s as per scope of works of SBD |
358 | LT Distribution box polyester sheet moulding compound (SMC) for 250 kVA Distribution transformer with arrangement of suitable bus-bars & MCCB"s as per scope of works of SBD |
359 | Back clamp support for LTDB ( 65x8 mm) |
360 | Whole Current A.C. Single Phase Smart Energy Meter |
361 | Whole Current A.C. Three Phase Smart Energy Meter |
362 | 1Cx16 sqmm 1.1KV XLPE cable with suitable lugs and glands and cable ties |
363 | 1Cx35 sqmm 1.1KV XLPE cable with suitable lugs and glands and cable ties |
364 | 1Cx70 sqmm 1.1KV XLPE cable with suitable lugs and glands and cable ties |
365 | 1Cx150 sqmm 1.1KV XLPE cable with suitable lugs and glands and cable ties |
366 | Clamps for LT service cable support |
367 | 9 kV, 5 kA distribution class LA |
368 | 11 kV, 3-ph, 200 A, 3 Pin type Vertical Mounting typeAB Switch along with Support Insulators, Base Channel, down Pipe, operating handle and support, etc. complete asper technical specifications, scope of works and approved drawings |
369 | 11 kV, 3-ph, Drop Out fuse Set (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete asper technical specifications, scope of works and approved drawings |
370 | GI Earthing pipe of 40 mm dia & 3000 mm long as per IS 1161 |
371 | GI Flat (50x6 mm) |
372 | GI wire 8SWG |
373 | GI flat (25x3 mm) |
374 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
375 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
376 | Numbering of pole of each support as per Technical specification and scope of work |
377 | LT line for segregated feeders |
378 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
379 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
380 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
381 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) |
382 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with calmps (40x3 mm) and nut & bolts |
383 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with calmps (40x3 mm) and nut & bolts |
384 | 2Cx25 sqmm XLPE aluminium conductor cable for single phase DB incomer |
385 | 4Cx35 sqmm XLPE aluminium conductor cable for Three phase DB incomer |
386 | Earthing of pole by earthing coil (with Salt & Charcoal) |
387 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
388 | Aerial Bunched XLPE Cable 1X25 (Ph) + 1X25 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
389 | Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
390 | Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
391 | LT pole clamp (50x8mm) (2.56 kg) with Nut and bolts |
392 | LT Eye hook |
393 | suspension clamp |
394 | Dead end clamp |
395 | Insulation Piercing connectors/Connector type-I (AB cable to AB cable) |
396 | Insulation Piercing connectors type-II (AB cable to Service cable) |
397 | End cap for AB cable 25 sqmm |
398 | End cap for AB cable 50 sqmm |
399 | End cap for AB cable 95 sqmm |
400 | Feeder Bifurcation (33KV Line) |
401 | Overhead 33 kV new feeder |
402 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
403 | 9 meter long /400 KG PCC Poles (PCC Pole as per state practice) |
404 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
405 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
406 | 13 M long steel Tubular poles with welded steel base plate of Designation 410 SP 72 |
407 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
408 | Stone pad for supports as per scope of works & drawing (450x450x75 mm ) |
409 | Red oxide paint as per TS |
410 | Aluminium paint as per TS |
411 | V type cross arm (MS Channel-100x50x6 mm 1980 mm long) welded with MS angel (65x65x6 mm 935 mm long) with bolts and nuts |
412 | Cross arm holding clamps (MS Flat-65x8 mm) with bolts and nuts |
413 | F- Bracket (MS Channel-100x50x6 mm (475 mm long) welded with MS Angle-75x75x6 mm (75 mm long) with bolts and nuts |
414 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
415 | Horizontal belting Angle (Angle-65x65x6 mm) 2240 mm long with bolts and nuts |
416 | Cross bracing Angle (Angle-65x65x6 mm) 2500 mm long with bolts and nuts |
417 | Bracing clamp-Top clamp (Flat-65x8 mm) with bolts and nuts |
418 | Bracing clamp-Bottom clamp (Flat-65x8 mm) with bolts and nuts |
419 | Fish plate for jumpering |
420 | 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog conductor |
421 | 30/3.00 + 7/3.00 mm (200 sqmm Al.Area)- ACSR Panther conductor |
422 | PG clamp for dog conductor |
423 | PG clamp for Panther conductor |
424 | Armoured Rod with Ferrule |
425 | Jointing sleeves Aluminium |
426 | Aluminium binding wire and tape |
427 | 33 KV polymer Disc insulator 70 KN (B&S type) along with suitable hardware fittings |
428 | 33 KV Polymer Pin Insulators 10 KN with nuts |
429 | Earthing of pole by earthing coil (with Salt & Charcoal) |
430 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
431 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
432 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
433 | Numbering of pole of each support as per Technical specification and scope of work |
434 | Underground 33 kV new feeder |
435 | Radar route survey for route profile of any utility cables,pipes etc. along the route as per TS and scope of work |
436 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
437 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
438 | Red oxide paint as per TS |
439 | Aluminium paint as per TS |
440 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
441 | Horizontal belting Angle (Angle-65x65x6 mm) 2240 mm long with bolts and nuts |
442 | Cross bracing Angle (Angle-65x65x6 mm) 2500 mm long with bolts and nuts |
443 | Bracing clamp-Top clamp (Flat-65x8 mm) with bolts and nuts |
444 | Bracing clamp-Bottom clamp (Flat-65x8 mm) with bolts and nuts |
445 | Fish plate for jumpering |
446 | 33 KV Polymer Pin Insulators 10 KN with nuts |
447 | Heat Shrinkable Jointing kit indoor for 33 KV 3×300 sq.mm. XLPE Cable |
448 | Heat Shrinkable Jointing kit outdoor for 33 KV 3×300 sq.mm. XLPE Cable |
449 | Heat Shrinkable Cable Jointing kit straight through for 33 kv 3×300 sq.mm. XLPE Cable |
450 | Road Restoration Chages for Pucca Road Crossing |
451 | Road Restoration chages for Kucchha Road Crossing |
452 | Supply and Placing of Pre-cast Concrete Manhole Chambers of size 900mm x 900mm Internal Dimension x 800mm Height & 100mm wall thickness (Heavy Duty) with Concrete Cover of 100mm thickness in the specified locations in the trench. |
453 | Supply & Erection of 33 kV Single core 120 sqmm XLPE Aluminium cable for jumpering |
454 | Supply & Erection of Aluminum lugs -300 Sq.mm. |
455 | Supply & Erection of Cable warning tape |
456 | Fixing of Cable marker on cable route and inscription of feeder name and voltage on cable marker |
457 | supply of 33 KV 3×300 sqmm XLPE Cable |
458 | Earth digging, laying, termination/jointing, Erection, Testing & commissioning of 33 KV grade 3-core 300 Sqmm XLPE power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per TS/approved drawing. |
459 | Laying of 3x300 sq mm XLPE Singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (all the material |
460 | Laying of 3x300 sq mm XLPE twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick,sand,stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. The ferruling of cable also include in this work (all the material |
461 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection, Testing & commissioning of 33 KV grade 3-core 300 Sqmm XLPE power cable undergroundusing HDPE pipecomplete in all respect along with all accessories, earthing etc. and as per TS/approved drawing . |
462 | Cable laying charges |
463 | Pipe (HDPE 160 mm dia) for Cable Laying |
464 | Earth digging by horizontal Directional Drilling(HDD)method,Laying, termination/jointing, Erection, Testing & commissioning of 33 KV grade 3-core 300 Sqmm XLPE power cable undergroundwithout HDPE Pipes in all respect along with all accessories, earthing etc. and as per TS/approved drawing . |
465 | Cable laying charges |
466 | Hoisting of following sizes of33 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6"" dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.(all the material shall be arranged by contractor) |
467 | Testing & commissioning of 33 kV 3-core 300 Sqmm XLPE power underground cable |
468 | Earthing of pole by earthing coil (with Salt & Charcoal) |
469 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
470 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
471 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
472 | Numbering of pole of each support as per Technical specification and scope of work |
473 | Feeder Bifurcation(11KV Line) |
474 | Overhead 11 kV New feeder |
475 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
476 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
477 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
478 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
479 | 13 M long steel Tubular poles with welded steel base plate of Designation 410 SP 72 |
480 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
481 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) |
482 | Red oxide paint as per TS |
483 | Aluminium paint as per TS |
484 | 11KV V-Type Cross-arm (M.S Channel 75X40x6mm) welded with MS angel (50x50x6) (weight-10.37 kg) with bolts and nuts |
485 | Cross arm holding clamps (MS Flat-50x8 mm) (weight-1.33 kg) with bolts and nuts |
486 | F- Bracket MS flat (50x8 mm) (weight- 1.56 kg) with nut and bolts |
487 | Cut point top channel (100x50x6 mm) of length 230 mm along with nut & bolts |
488 | Cut point bottom channel (100x50x6 mm) of length 1150 mm along with nut & bolts |
489 | Tapping horizontal cross arm (100x50x6 mm) of length 1020 mm along with calmps (50x8) and nut and bolts |
490 | Tapping top channel (100x50x6 mm) of length 256 mm along with calmps(50x8) and nut and bolts |
491 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
492 | Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts |
493 | Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts |
494 | Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts |
495 | Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts |
496 | Fish plate for jumpering |
497 | 6/2.59 + 1/2.59 mm (30 sqmm Al. Area) ACSR weasel conductors |
498 | 6/3.35 + 1/3.35 mm (50 sqmm Al. Area) ACSR Rabbit conductors |
499 | 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog conductor |
500 | PG clamp for weasel conductor |
501 | PG clamp for Rabbit conductor |
502 | PG clamp for dog conductor |
503 | Distribution tie for pin insulator |
504 | Armoured Rod with Ferrule |
505 | Jointing sleeves Aluminium |
506 | Aluminium binding wire and tape |
507 | 11 KV polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings |
508 | 11 KV Polymer Pin Insulators 5 KN with nuts |
509 | 11 KV 3C×185 sqmm XLPE Cable |
510 | Heat Shrinkable Jointing kit outdoor for 11 KV 3C×185 sq.mm. XLPE Cable |
511 | Heat Shrinkable Cable Jointing kit straight through for 11 kv 3C×185 sq.mm. XLPE Cable |
512 | Hoisting of following sizes of11 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6"" dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.(all the material shall be arranged by contractor) |
513 | Earthing of pole by earthing coil (with Salt & Charcoal) |
514 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
515 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
516 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
517 | Numbering of pole of each support as per Technical specification and scope of work |
518 | Underground 11 kV New feeder |
519 | Radar route survey for route profile of any utility cables,pipes etc. along the route as per TS and scope of work |
520 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
521 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
522 | Red oxide paint as per TS |
523 | Aluminium paint as per TS |
524 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
525 | Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts |
526 | Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts |
527 | Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts |
528 | Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts |
529 | Fish plate for jumpering |
530 | 11 KV Polymer Pin Insulators 5 KN with nuts |
531 | Heat Shrinkable Jointing kit indoor for 11 KV 3C×185 sq.mm. XLPE Cable |
532 | Heat Shrinkable Jointing kit indoor for 11 KV 3×300 sq.mm. XLPE Cable |
533 | Heat Shrinkable Jointing kit outdoor for 11 KV 3C×185 sq.mm. XLPE Cable |
534 | Heat Shrinkable Jointing kit outdoor for 11 KV 3×300 sq.mm. XLPE Cable |
535 | Heat Shrinkable Cable Jointing kit straight through for 11 kv 3C×185 sq.mm. XLPE Cable |
536 | Heat Shrinkable Cable Jointing kit straight through for 11 kv 3×300 sq.mm. XLPE Cable |
537 | Road Restoration Chages for Pucca Road Crossing |
538 | Road Restoration chages for Kucchha Road Crossing |
539 | Supply and Placing of Pre-cast Concrete Manhole Chambers of size 900mm x 900mm Internal Dimension x 800mm Height & 100mm wall thickness (Heavy Duty) with Concrete Cover of 100mm thickness in the specified locations in the trench. |
540 | Supply & Erection of 11 kV Single core 95 sqmm XLPE Aluminium cable for jumpering |
541 | Supply & Erection of Aluminum lugs -185 Sq.mm. |
542 | Supply & Erection of Aluminum lugs -300 Sq.mm. |
543 | Supply & Erection of Cable warning tape |
544 | Fixing of Cable marker on cable route and inscription of feeder name and voltage on cable marker |
545 | Supply of 11 KV 3C×185 sqmm XLPE Cable |
546 | Supply of 11 KV 3×300 sqmm XLPE Cable |
547 | Earth digging, laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 185/300 Sqmm XLPE power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per TS/approved drawing. |
548 | Laying of 11 KV 3Cx185 sq mm XLPE Singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (all the material |
549 | Laying of 11 KV 3x185 sq mm XLPE twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick,sand,stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. The ferruling of cable also include in this work (all the material) |
550 | Laying of 3x300 sq mm XLPE Singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (all the material |
551 | Laying of 3x300 sq mm XLPE twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick,sand,stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. The ferruling of cable also include in this work (all the material |
552 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 185/300 Sqmm XLPE power cable undergroundusing HDPE pipecomplete in all respect along with all accessories, earthing etc. and as per TS/approved drawing . |
553 | Laying of 11 KV 3C×185 sqmm XLPE Cable |
554 | Laying of 11 KV 3×300 sqmm XLPE Cable |
555 | Pipe (HDPE 160 mm dia) for Cable Laying |
556 | Earth digging by horizontal Directional Drilling(HDD)method,Laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 185/300 Sqmm XLPE power cable undergroundwithout HDPE Pipes in all respect along with all accessories, earthing etc. and as per TS/approved drawing. |
557 | Laying of 11 KV 3C×185 sqmm XLPE Cable |
558 | Laying of 11 KV 3×300 sqmm XLPE Cable |
559 | Hoisting of following sizes of11 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6"" dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.(all the material shall be arranged by contractor) |
560 | Testing & commissioning of 11 KV grade 3-core 185 Sqmm XLPE power underground cable |
561 | Testing & commissioning of 11 kV 3-core 300 Sqmm XLPE power underground cable |
562 | Earthing of pole by earthing coil (with Salt & Charcoal) |
563 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
564 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
565 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
566 | Numbering of pole of each support as per Technical specification and scope of work |
567 | Augumentation/Reconductoring of 33KV line |
568 | Overhead 33 kV Augumentation/Reconductoring |
569 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
570 | 9 meter long /400 KG PCC Poles (PCC Pole as per state practice) |
571 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
572 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
573 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
574 | Stone pad for supports as per scope of works & drawing (450x450x75 mm ) |
575 | Red oxide paint as per TS |
576 | Aluminium paint as per TS |
577 | V type cross arm (MS Channel-100x50x6 mm 1980 mm long) welded with MS angel (65x65x6 mm 935 mm long) with bolts and nuts |
578 | Cross arm holding clamps (MS Flat-65x8 mm) with bolts and nuts |
579 | F- Bracket (MS Channel-100x50x6 mm (475 mm long) welded with MS Angle-75x75x6 mm (75 mm long) with bolts and nuts |
580 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
581 | Horizontal belting Angle (Angle-65x65x6 mm) 2240 mm long with bolts and nuts |
582 | Cross bracing Angle (Angle-65x65x6 mm) 2500 mm long with bolts and nuts |
583 | Bracing clamp-Top clamp (Flat-65x8 mm) with bolts and nuts |
584 | Bracing clamp-Bottom clamp (Flat-65x8 mm) with bolts and nuts |
585 | Fish plate for jumpering |
586 | 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog conductor |
587 | 30/3.00 + 7/3.00 mm (200 sqmm Al.Area)- ACSR Panther conductor |
588 | PG clamp for dog conductor |
589 | PG clamp for Panther conductor |
590 | Armoured Rod with Ferrule |
591 | Jointing sleeves Aluminium |
592 | Aluminium binding wire and tape |
593 | 33 KV polymer Disc insulator 70 KN (B&S type) along with suitable hardware fittings |
594 | 33 KV Polymer Pin Insulators 10 KN with nuts |
595 | Earthing of pole by earthing coil (with Salt & Charcoal) |
596 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
597 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
598 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
599 | Numbering of pole of each support as per Technical specification and scope of work |
600 | Removal of existing material and shifting to MVVNL store |
601 | Underground 33 kV Augumentation/Reconductoring |
602 | Radar route survey for route profile of any utility cables,pipes etc. along the route as per TS and scope of work |
603 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
604 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
605 | Red oxide paint as per TS |
606 | Aluminium paint as per TS |
607 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
608 | Horizontal belting Angle (Angle-65x65x6 mm) 2240 mm long with bolts and nuts |
609 | Cross bracing Angle (Angle-65x65x6 mm) 2500 mm long with bolts and nuts |
610 | Bracing clamp-Top clamp (Flat-65x8 mm) with bolts and nuts |
611 | Bracing clamp-Bottom clamp (Flat-65x8 mm) with bolts and nuts |
612 | Fish plate for jumpering |
613 | 33 KV Polymer Pin Insulators 10 KN with nuts |
614 | Heat Shrinkable Jointing kit indoor for 33 KV 3×300 sq.mm. XLPE Cable |
615 | Heat Shrinkable Jointing kit outdoor for 33 KV 3×300 sq.mm. XLPE Cable |
616 | Heat Shrinkable Cable Jointing kit straight through for 33 kv 3×300 sq.mm. XLPE Cable |
617 | Road Restoration Chages for Pucca Road Crossing |
618 | Road Restoration chages for Kucchha Road Crossing |
619 | Supply and Placing of Pre-cast Concrete Manhole Chambers of size 900mm x 900mm Internal Dimension x 800mm Height & 100mm wall thickness (Heavy Duty) with Concrete Cover of 100mm thickness in the specified locations in the trench. |
620 | Supply & Erection of 33 kV Single core 120 sqmm XLPE Aluminium cable for jumpering |
621 | Supply & Erection of Aluminum lugs -300 Sq.mm. |
622 | Supply & Erection of Cable warning tape |
623 | Fixing of Cable marker on cable route and inscription of feeder name and voltage on cable marker |
624 | supply 33 KV 3×300 sqmm XLPE Cable |
625 | Earth digging, laying, termination/jointing, Erection, Testing & commissioning of 33 KV grade 3-core 300 Sqmm XLPE power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per TS/approved drawing. |
626 | Laying of 3x300 sq mm XLPE Singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (all the material |
627 | Laying of 3x300 sq mm XLPE twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick,sand,stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. The ferruling of cable also include in this work (all the material |
628 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection, Testing & commissioning of 33 KV grade 3-core 300 Sqmm XLPE power cable undergroundusing HDPE pipecomplete in all respect along with all accessories, earthing etc. and as per TS/approved drawing . |
629 | Laying of 33 KV 3×300 sqmm XLPE Cable |
630 | Pipe (HDPE 160 mm dia) for Cable Laying |
631 | Earth digging by horizontal Directional Drilling(HDD)method,Laying, termination/jointing, Erection, Testing & commissioning of 33 KV grade 3-core 300 Sqmm XLPE power cable undergroundwithout HDPE Pipes in all respect along with all accessories, earthing etc. and as per TS/approved drawing. |
632 | Laying of 33 KV 3×300 sqmm XLPE Cable |
633 | Hoisting of following sizes of33 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6"" dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.(all the material shall be arranged by contractor) |
634 | Testing & commissioning of 33 kV 3-core 300 Sqmm XLPE power underground cable |
635 | Earthing of pole by earthing coil (with Salt & Charcoal) |
636 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
637 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
638 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
639 | Numbering of pole of each support as per Technical specification and scope of work |
640 | Removal of existing material and shifting to MVVNL store |
641 | Augumentation/Reconductoring of 11KV line |
642 | Overhead 11 kV Augumentation/Reconductoring |
643 | Route survey and pole spotting and mapping (as per Employer requirement of SBD) |
644 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
645 | Foundation of PCC Supports as per scope of works, cement concreting (1:2:4) (0.268 Cmt for each support) |
646 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) |
647 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
648 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
649 | Red oxide paint as per TS |
650 | Aluminium paint as per TS |
651 | 11KV V-Type Cross-arm (M.S Channel 75X40x6mm) welded with MS angel (50x50x6) (weight-10.37 kg) with bolts and nuts |
652 | Cross arm holding clamps (MS Flat-50x8 mm) (weight-1.33 kg) with bolts and nuts |
653 | F- Bracket MS flat (50x8 mm) (weight- 1.56 kg) with nut and bolts |
654 | Cut point top channel (100x50x6 mm) of length 230 mm along with nut & bolts |
655 | Cut point bottom channel (100x50x6 mm) of length 1150 mm along with nut & bolts |
656 | Tapping horizontal cross arm (100x50x6 mm) of length 1020 mm along with calmps (50x8) and nut and bolts |
657 | Tapping top channel (100x50x6 mm) of length 256 mm along with calmps(50x8) and nut and bolts |
658 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
659 | Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts |
660 | Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts |
661 | Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts |
662 | Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts |
663 | Fish plate for jumpering |
664 | 6/2.59 + 1/2.59 mm (30 sqmm Al. Area) ACSR weasel conductors |
665 | 6/3.35 + 1/3.35 mm (50 sqmm Al. Area) ACSR Rabbit conductors |
666 | 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog conductor |
667 | PG clamp for weasel conductor |
668 | PG clamp for Rabbit conductor |
669 | PG clamp for dog conductor |
670 | Distribution tie for pin insulator |
671 | Armoured Rod with Ferrule |
672 | Jointing sleeves Aluminium |
673 | Aluminium binding wire and tape |
674 | 11 KV polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings |
675 | 11 KV Polymer Pin Insulators 5 KN with nuts |
676 | Earthing of pole by earthing coil (with Salt & Charcoal) |
677 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
678 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
679 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
680 | Numbering of pole of each support as per Technical specification and scope of work |
681 | Removal of existing material and shifting to MVVNL store |
682 | Underground 11 kV Augumentation/Reconductoring |
683 | Radar route survey for route profile of any utility cables,pipes etc. along the route as per TS and scope of work |
684 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 |
685 | Foundation of STP Supports as per scope of works, cement concreting (1:2:4) (0.5 cmt for each support & .014 cmt. For muffing) |
686 | Red oxide paint as per TS |
687 | Aluminium paint as per TS |
688 | DP Top channel (Channel-100X50x6mm) 2240 mm longwith bolts and nuts |
689 | Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts |
690 | Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts |
691 | Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts |
692 | Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts |
693 | Fish plate for jumpering |
694 | 11 KV Polymer Pin Insulators 5 KN with nuts |
695 | Heat Shrinkable Jointing kit indoor for 11 KV 3C×185 sq.mm. XLPE Cable |
696 | Heat Shrinkable Jointing kit indoor for 11 KV 3×300 sq.mm. XLPE Cable |
697 | Heat Shrinkable Jointing kit outdoor for 11 KV 3C×185 sq.mm. XLPE Cable |
698 | Heat Shrinkable Jointing kit outdoor for 11 KV 3×300 sq.mm. XLPE Cable |
699 | Heat Shrinkable Cable Jointing kit straight through for 11 kv 3C×185 sq.mm. XLPE Cable |
700 | Heat Shrinkable Cable Jointing kit straight through for 11 kv 3×300 sq.mm. XLPE Cable |
701 | Road Restoration Chages for Pucca Road Crossing |
702 | Road Restoration chages for Kucchha Road Crossing |
703 | Supply and Placing of Pre-cast Concrete Manhole Chambers of size 900mm x 900mm Internal Dimension x 800mm Height & 100mm wall thickness (Heavy Duty) with Concrete Cover of 100mm thickness in the specified locations in the trench. |
704 | Supply & Erection of 11 kV Single core 95 sqmm XLPE Aluminium cable for jumpering |
705 | Supply & Erection of Aluminum lugs -185 Sq.mm. |
706 | Supply & Erection of Aluminum lugs -300 Sq.mm. |
707 | Supply & Erection of Cable warning tape |
708 | Fixing of Cable marker on cable route and inscription of feeder name and voltage on cable marker |
709 | supply of 11 KV 3C×185 sqmm XLPE Cable |
710 | supply of 11 KV 3×300 sqmm XLPE Cable |
711 | Earth digging, laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 185/300 Sqmm XLPE power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per TS/approved drawing. |
712 | Laying of 11 KV 3Cx185 sq mm XLPE Singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (all the material |
713 | Laying of 11 KV 3x185 sq mm XLPE twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick,sand,stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. The ferruling of cable also include in this work (all the material) |
714 | Laying of 3x300 sq mm XLPE Singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (all the material |
715 | Laying of 3x300 sq mm XLPE twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick,sand,stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. The ferruling of cable also include in this work (all the material |
716 | Earth digging by horizontal Directional Drilling(HDD)method, Laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 185/300 Sqmm XLPE power cable undergroundusing HDPE pipecomplete in all respect along with all accessories, earthing etc. and as per TS/approved drawing . |
717 | Laying of 11 KV 3C×185 sqmm XLPE Cable |
718 | Laying of 11 KV 3×300 sqmm XLPE Cable |
719 | Pipe (HDPE 160 mm dia) for Cable Laying |
720 | Earth digging by horizontal Directional Drilling(HDD)method,Laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 185/300 Sqmm XLPE power cable undergroundwithout HDPE Pipes in all respect along with all accessories, earthing etc. and as per TS/approved drawing . |
721 | Laying of 11 KV 3C×185 sqmm XLPE Cable |
722 | Laying of 11 KV 3×300 sqmm XLPE Cable |
723 | Hoisting of following sizes of11 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6"" dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.(all the material shall be arranged by contractor) |
724 | Testing & commissioning of 11 KV grade 3-core 185 Sqmm XLPE power underground cable |
725 | Testing & commissioning of 11 kV 3-core 300 Sqmm XLPE power underground cable |
726 | Earthing of pole by earthing coil (with Salt & Charcoal) |
727 | 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers |
728 | MS Danger board with Back calmps & nuts and boltsas per Technical specification |
729 | Anti-climbing device - 3.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works &TS |
730 | Numbering of pole of each support as per Technical specification and scope of work |
731 | Removal of existing material and shifting to MVVNL store |
732 | LT line with underground cabling |
733 | Radar route survey for route profile of any utility cables,pipes etc. along the route as per TS and scope of work |
734 | Supply & laying of LT Aluminium XLPE Cable 1Cx630 Sq.mm. |
735 | Supply & laying of LT Aluminium XLPE Cable 1Cx400 Sq.mm. |
736 | Supply of 1100 V Grade, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable of 3.5Cx70 sqmm |
737 | Supply of 1100 V Grade, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable of 3.5Cx150 sqmm |
738 | Supply of 1100 V Grade, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable of 3.5Cx240 sqmm |
739 | Laying of 1100 V Grade 3.5Cx70 sqmm, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable to be laid underground in trenches. |
740 | Laying of 1100 V Grade 3.5Cx150 sqmm, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable to be laid underground in trenches. |
741 | Laying of 1100 V Grade 3.5Cx240 sqmm, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable to be laid underground in trenches. |
742 | Laying of 1100 V Grade 3.5Cx70 sqmm by horizontal Directional Drilling(HDD)method, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable to be laid underground in HDPE pipe. |
743 | Laying of 1100 V Grade 3.5Cx150 sqmm by horizontal Directional Drilling(HDD)method, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable to be laid underground in HDPE pipe. |
744 | Laying of 1100 V Grade 3.5Cx240 sqmm by horizontal Directional Drilling(HDD)method, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable to be laid underground in HDPE pipe. |
745 | Cable end termination using total double compression brass glands and crimping type Aluminium Thimbles for 3.5Cx70 sqmm |
746 | Cable end termination using total double compression brass glands and crimping type Aluminium Thimbles for 3.5Cx150 sqmm |
747 | Cable end termination using total double compression brass glands and crimping type Aluminium Thimbles for 3.5Cx240 sqmm |
748 | Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying of 1100 V Grade, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cables. |
749 | Back fillng & restoring the road to make it as original including supply of all material. |
750 | Supply & laying of HDPE pipe of following size by Horizontal drilling for underground piping (trenchless) for above cable at road crossings. Min Depth of pipe shall be 1.2 M below surface. |
751 | 160 mm dia |
752 | 110 mm dia |
753 | 50 mm dia |
754 | Supply and marking of manhole 750x600 mm with manhole cover for pullingLT cable in lanes by lanes |
755 | Supply , installation and testing of 7x20 SWG GI Wire for earthing along cables. |
756 | Supply and laying of pipe for service cable to houses. |
757 | Gl Pipe of 50 mm dia (external area) |
758 | Gl Pipe of 40 mm dia (external area) |
759 | PVC pipe heavy gauge 50 mm dia (underground area) |
760 | PVC pipe heavy gauge 40 mm dia (underground area) |
761 | Supply and installation of RCC pipe of folloing size: |
762 | 150 mm |
763 | 200 mm |
764 | 300 mm |
765 | Supply and installation of 8 SWG Earthing GI wire |
766 | Supply and making steel structure work and painting the same with two coats of primer and two coats of enamel paint. |
767 | Supply and laying (in GI Pipe) of 1100 V Grade, PVC sheathed steel strip armoured, aluminum conductor LT XLPE insulated cable of size 2x10 sq.mm. XLPE (For Street light) |
768 | Supply & laying of Gl Pipe of 40 mm dia. Underground |
769 | Supply & installation of Junction Box on STP with 900 mm long GI Pipe 25 mm dia. With clamps for street light connection. |
770 | Supply and erection of earthing 40 mm dia 15 M. long G.I.Pipe vertically for earthing having 12mm dia holes spaced 75 mm apart drilled up to 2M from the bottom all complete as per specification |
771 | Fixing of GI Strip of following sizes with hardware, mounting clamps etc.: |
772 | 25 x 3 mm. GI Strip |
773 | 32 x 6 mm. GI Strip |
774 | 50 x 6 mm. GI Strip |
775 | Dismantling of LT overhead line and Transportation of dismantled material to MVVNL Stores. |
776 | Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, vermin proof and in closer protection shall be IP-54 (suitable for outdoor applications) as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 14-SWG CRCA Sheet Steel & Provided with 16SWG Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 1000 & 630 KVA (Type A-1) Incomer - 1 No. 1250 Amp. TP MDO ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 400 amp. TP MCCB with spreader & Extended handle) (2 sets of 250amp. TP MCCB with spreader & Extended handle)(2 sets of 100 0amp. TP MCCB with spreader & Extended handle) |
777 | Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubicle should be weather proof, Dust proof, vermin proof and in closer protection shall be IP-54 (suitable for outdoor applications) as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 14-SWG CRCA Sheet Steel & Provided with 16SWG Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 400 KVA (Type A-2) (Incomer - 1 set of 800 amp.TP MDO ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 6 sets of 250 amp. TP MCCB with spreader & Extended handle (5No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
778 | Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, vermin proof and in closer protection shall be IP-54 (suitable for outdoor applications) as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 14-SWG CRCA Sheet Steel & Provided with 16SWG Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 250 KVA (Type A-3) (Incomer - 1 set of 630 amp. TP MDO ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs)) (Outgoing - 5 sets of 250 amp. TP MCCB with spreader & Extended handle (4No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
779 | Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, vermin proof and in closer protection shall be IP-54 (suitable for outdoor applications) as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 14-SWG CRCA Sheet Steel & Provided with 16SWG Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 160 KVA (Type A-4) (Incomer - 1 set of 400 amp. TP MDO ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 250 amp. TP MCCB with spreader & Extended handle (3No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
780 | Supply of Outdoor type LT Disribution Boards with a rupturing capacity of 50KA at 415V or as called for individual items (CPRI Approved manufacturer), openable in front and back suitable for 3 plase, 4 wire, 50Hz AC supply and an ambient temperature of 45 deg. C. The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-54 (suitable for outdoor applications) as per IS 2147-1962 and IS: 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel and provided with 16 SWG hinged doors including suitable foundation. MAIN LT PANEL AT SUB STATION- 100KVA (Type A-5) Incomer- 1 Set of 250 Amp. TP MCCB with Spreader & Extended handle Metering on Incomer - 1 Set of Digital Ammeter with ASS - 1 Set of Digital Voltmeter with VSS - 1 Set of LED type Phase Indicating Light (22.5 mm.) with Control MCBs Outgoing- 3 Set of 63 Amp. TP MCCB with Spreader & Extended handle ( 2 Nos. + 1 No. for capacitor panel) - 3 Set of100 Amp. TP MCCB with Spreader & Extended handle |
781 | Supply of Outdoor type LT Disribution Boards with a rupturing capacity of 50KA at 415V or as called for individual items (CPRI Approved manufacturer), openable in front and back suitable for 3 plase, 4 wire, 50Hz AC supply and an ambient temperature of 45 deg. C. The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-54 (suitable for outdoor applications) as per IS 2147-1962 and IS: 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel and provided with 16 SWG hinged doors including suitable foundation. MAIN LT PANEL AT SUB STATION- 63 & 25KVA (Type A-6) Incomer- 1 Set of 160 Amp. TP MCCB with Spreader & Extended handle Metering on Incomer - 1 Set of Digital Ammeter with ASS - 1 Set of Digital Voltmeter with VSS - 1 Set of LED type Phase Indicating Light (22.5 mm.) with Control MCBs Outgoing- 4 Set of 63 Amp. TP MCCB with Spreader & Extended handle - 1 Set of32 Amp. TP MCCB with Spreader & Extended handle (for capacitor Panel) |
782 | Supply , installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2 mm CRCA sheet and covers will be 1.6mm CRCA sheet duly powder coated paint with 400 amps Al. busbar. (Type-B1) Incomer - 250 Amp. TP MCCB - 1 No. Outgoing - 63 Amp. TP MCCB- 6 Nos. The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-54 (suitable for outdoor applications) as per IS 2147-1962 and IS: 8623. |
783 | Supply , installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2 mm CRCA sheet and covers will be 1.6mm CRCA sheet duly powder coated paint with 300 amps Al. busbar. (Type-B2) Incomer - 250 Amp. TP MCCB - 1 No. Outgoing - 63 Amp. TP MCCB- 5 Nos. The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-54 (suitable for outdoor applications) as per IS 2147-1962 and IS: 8623. |
784 | Supply , installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2 mm CRCA sheet and covers will be 1.6mm CRCA sheet duly powder coated paint with 300 amps Al. busbar. (Type-B3) Incomer - 100 Amp. TP MCCB - 1 No. Outgoing - 63 Amp. TP MCCB- 4 Nos. The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-54 (suitable for outdoor applications) as per IS 2147-1962 and IS: 8623. |
785 | Supply , installation, testing & commissioning of Lockable distribution boxes of size 450X400mm with bus bar 100 Amp. TPN to feed upto 10 houses (Type C). The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-54 (suitable for outdoor applications) as per IS 2147-1962 and IS: 8623.The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel and provided with 16 SWG hinged doors including suitable foundation |
786 | Supply of Steel Structure of size 65x65x6 mm (M.S. Angle ) including supply of Nut bolt and washres. |
787 | Supply and laying of Single phase (2CX4 sqmm) XLPE Armoured Service Cable |
788 | Supply and laying of Single phase (2CX6 sqmm) XLPE Armoured Service Cable |
789 | Supply and laying of three phase (4CX16 sqmm) XLPE Armoured Service Cable |
790 | Supply & installation of single coil earthing at Type A, B and double coil earthing at Type-C panels |
791 | Supply & erection of Plinth for Outdoor type LT Disribution Boards (A-type) and Distribution feeder pillar Box ( B Type) |
792 | Supply & erection of Plinth for Outdoor type LT Disribution Sevice Pillar (C-type) |
793 | supply & Erection of Single phase poly carbonate meter box after removal of existing meter box and connections of meters with armoured cable laid along with resealing of meter with seals provided by MVVNL |
794 | Supply & Erection of Three phase poly carbonate meter box after removal of existing meter box and connections of meters with armoured cable laid along with resealing of meter with seals provided by MVVNL |
795 | Testing & commissioning of 3.5-core 240 Sqmm XLPE power underground cable |
796 | Testing & commissioning of 3.5-core 150 Sqmm XLPE power underground cable |
797 | Testing & commissioning of 3.5-core 70 Sqmm XLPE power underground cable |
798 | Installation of capacitor bank |
799 | Installation of capacitor bank at 33/11 kV Power Transformer |
800 | 12.65 kV, 1980 kVAr, 3-Phase, 50 C/s, Outdoor Type , Capacitor bank having two variable step of 792 Kvar & one Variable steps of 396 kVAr. Bank shall be complete with Capacitor units of 264/132 kVAr,Aluminium busbars, Pin & Post insulators, Expulsion fuses etc. |
801 | 12.65 KV,3960 KVAr, 3-Phase, 50 C/s, Outdoor type, Capacitor bank having two variable step of 792 KVAr & two variable steps of 1188 KVAr. Bank shall be complete with Capacitor units of264/396 KVAr, Aluminimum busbars, pin & post insulators, Expulsion fuses etc. |
802 | 0.79 KVAr for 1188 KVAr step |
803 | 0.52 kVAr for 792 kVAr step |
804 | 0.25 kVAr for 396 kVAr step |
805 | 11 kV, 3-Phase Oil-Cooled RVT |
806 | 12 kV 3 Phase Outdoor type metal enclosed Vacuum Capacitor switches. |
807 | 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure. |
808 | 9 kV, 10 kA,Station Class, Lightning Arrestors |
809 | Indoor Type Automatic Control Unit |
810 | Hot dip galvanised structures for complete system |
811 | Control cables, lugs/thimble, Junction Box etc. |
812 | 11 KV XLPE insulated 3x120 mm2Armoured |
813 | Indoor temination kit |
814 | Outdoor temination kit |
815 | 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar. |
816 | Casting of Civil foundation |
817 | Cable trench for laying of power/control cables. |
818 | Earthing for structure and LA"s by pipe in pipe earthing (GI Earthing pipe of 40 mm dia & 3000 mm long as per IS 1161) |
819 | GI strip of size 50x6 mm for connection of earthing with equipment |
820 | Installation of capacitor bank at 11/0.415 kV Distribution Transformer |
821 | LT Pole cap Gas/Resin filled MPP (Metalized polypropylene) Shunt Capacitors 440V, 10 KVAr, 3 Phase 50 Hz, IP65 with fault indication. |
822 | LT Pole cap Gas/Resin filled MPP (Metalized polypropylene) Shunt Capacitors 440V, 25 KVAr, 3 Phase 50 Hz, IP65 with fault indication. |
823 | LT Pole cap Gas/Resin filled MPP (Metalized polypropylene) Shunt Capacitors 440V, 40 KVAr, 3 Phase 50 Hz, IP65 with fault indication. |
824 | Suitable pole clamps with nuts and bolts |
825 | 1Cx25 sqmm XLPE cable along with connecting clamps for connection of DTR with Capacitor bank |
826 | Earthing of existing substation and Distribution Transformer |
827 | Pipe earthing for Substation(3000 mm long) |
828 | Spike earthing for existing DTR ( 2500mm long) |
829 | Installation of 11 KV Horizontal Isolator, AB switch and LT Distribution boxfor Distribution Transformer |
830 | supply and erection of 11 KV Horizontal isolator with complete allied materials |
831 | Supply and erection of 11KV AB switch with complete allied materials |
832 | Supply and erection of LTDB made out of CRCA MS for 63 KVA DTR with all allied materials |
833 | Supply and erection of LTDB made out of CRCA MS for 100 KVA DTR with all allied materials |
834 | Supply and erection of LTDB made out of CRCA MS for 250 KVA DTR with all allied materials |
835 | Supply and erection of LTDB made out of CRCA MS for 400 KVA DTR with all allied materials |
836 | Supply and erection of LTDB made out of CRCA MS for 630 KVA DTR with all allied materials |
837 | Supply and erection of LTDB made out of CRCA MS for 1000 KVA DTR with all allied materials |
838 | Miscellaneous items |
839 | 11 kV Weasel covered conductor with accessories |
840 | 11 kV Rabbit covered conductor with accessories |
841 | 33 kV Dog covered conductor with accessories |
842 | Shear bolted Tusker terminal connector on HT side |
843 | Shear bolted Tusker terminal connector on LT side |
844 | Shear head bolted lugs (630 sqmm) |
845 | Shear head bolted lugs (400 sqmm) |
846 | Aluminium lug long barrel off size |
847 | MS Nut & Bolts |
848 | Plinth of Distribution Transformer (215 KVA to 630 KVA) with FRP fencing |
849 | Sign board of size 6x4 sqfeet, mounting angels, excavation, cement concreting, foundation, painting etc. |
850 | Sign board of size 1x1 sqfeet with pole mounting clamp, painting etc. |
851 | Stay Set (Galvanised) with 50x8 mm stay clamps, guy insulator , anchor plate (200x200x6mm) , nut bolts, 1 Nos turn-buckle, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work including foundation of stay support in each stay set as per scope of works |
852 | Stay Rod 16x1800 mm complete as per Technical specification, scope of work and tender drawing |
853 | Stay Wire 7/10 SWG |
854 | Stay Clamp- (Flat-50x8 mm) (weight-1.5 kg)with bolts and nuts |
855 | Stay Guy insulator LT |
856 | Stay Guy insulator HT (11 KV) |
857 | stay thimble |
858 | Hellically formed end fitting |
859 | Concreting of Stay Road ( 0.2 cmt cement concreting in mixture (1:2:4) |
860 | Stay Set (Galvanised) with 50x8 mm stay clamps, guy insulator , anchor plate (300x300x8mm) , nut bolts, 1 Nos turn-buckle, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work including foundation of stay support in each stay set as per scope of works |
861 | Stay Rod 20x1800 mm complete as per Technical specification, scope of work and tender drawing |
862 | Stay Wire 7/8 SWG |
863 | Stay Clamp- (Flat-50x8 mm) (weight-1.8 kg) with bolts and nuts |
864 | Stay Guy insulator for 33KV line |
865 | stay thimble |
866 | Hellically formed end fitting |
867 | Concreting of Stay Road ( 0.3 cmt cement concreting in mixture (1:2:4) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail