Special Repairs To Bldg No.04, ( Officer Mess ) , P-05 ( Ashoka ) , P-12 ( Officers Institute ) Airmen Billets Bldg No.01 ( Mukherjee Block ) , At Air Force Station Kalaikunda Under Ge ( Af ) Kalaikunda, kalaikunda-West Bengal

Military Engineer Services-MES has published Special Repairs To Bldg No.04, ( Officer Mess ) , P-05 ( Ashoka ) , P-12 ( Officers Institute ) Airmen Billets Bldg No.01 ( Mukherjee Block ) , At Air Force Station Kalaikunda Under Ge ( Af ) Kalaikunda. Submission Date for this Tender is 06-09-2022. Building Work Tenders in kalaikunda West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

33383601
Corrigendum : Special Repairs To Bldg No.04, ( Officer Mess ) , P-05 ( Ashoka ) , P-12 ( Officers Institute ) Airmen Billets Bldg No.01 ( Mukherjee Block ) , At Air Force Station Kalaikunda Under Ge ( Af ) Kalaikunda
Open Tender
Indian
West Bengal
kalaikunda
06-09-2022

Tender Details

Special Repairs To Bldg No.04, ( Officer Mess ) , P-05 ( Ashoka ) , P-12 ( Officers Institute ) Airmen Billets Bldg No.01 ( Mukherjee Block ) , At Air Force Station Kalaikunda Under Ge ( Af ) Kalaikunda

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Aug-2022 REVISED BOQ AND AMENDMENT IN TENDER DOCUMENTS BOQ 25-08-2022
2 20-Aug-2022 Date Corrigendum Date 27-08-2022
3 26-Aug-2022 Date Corrigendum .. Date 30-08-2022
4 30-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 86000.0 /-
Tender Value
INR 43 Lakhs /-

BOQ Items

Name of Work:SPECIAL REPAIRS TO BLDG NO.04, (OFFICER MESS), P-05 (ASHOKA), P-12 (OFFICERS INSTITUTE) AIRMEN BILLETS BLDG NO.01 (MUKHERJEE BLOCK), AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA.
Sl. No. Item Description
1Demolition ofCement Concrete of any description and in any positioncomplete all as directed.
2Demolition of cement concrete of any description and in any position not otherwise specifically provided for including taking out of old damaged unserviceable tarfelt or membrane of any description and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete to receive roof treatment all as specified and as directed.
3M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling with cement mortar (1:4) with using WPC as per manufacturers instruction over two coast of primer mixed of Latex and cement @ 1:4 (by weight) in the grooved portion and extended upto 100 mm both sides of groove complete all as specified and as directed.
4Cutting grooves n exc 75mm depth girth, and fill grooves surface with PCC 1:2:4 type type B0 using 12.5 mm graded stone aggregate with using WPC as per manufacturers instruction over two coast of primer mixed of Latex and cement @ 1:4 (by weight) in the grooved portion and extended upto 100 mm both sides of groove complete all as specified and as directed.
5M&L Cutting openings through walls for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the prem complete all as specified
6Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
7Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
8Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
9Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
10Taking down SWR pipes (any size or pattern), including all fittings, "T", bends,etc., including removal to store for taking credit (measured overall as fixed along the centre line over fittings and accessories), complete all as directed.
11Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered anglesthroating,and roof padding as directed including necessary from work complete all as specified and directed.
12Materials and Labour for, DigitalNon - skid Ceramic tiles, coloured, 9 to 10mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,conforming to IS 15622, Grade B II, in riser of steps, skirting, dado and pillar laid over cement screed baseincluding 15 thick rendering Cement mortar (1:3) complete all as specified and directed
13Materials and Labour for, DigitalNon - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
14Materials and Labour for, Digital glazed ceramic coloured tiles, 450 X 300 X 8mmthick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
15Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surfacefair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
16Material and labour for rendering 15 mm thick in cement mortar (1:4) on other than fair faces of brick or concrete surfaces (5mm thick CM 1:4 with WPC setting coat and 10mm thick CM 1:4 backing coat), including brushing in two layers of damp proof ultra as per manufacturars instruction of Make Asian or equivalent over plastered surface in sandwitched layer finished even & smooth without using extra cement all as specified and directed by Engineer-in-Charge.Note :- WPC inclusivein quoated rates
17Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - Note :- WPC inclusivein quoated rates
18Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces (on ceiling surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
19Preparation of concrete surface of chajja/beam/slabthoroughly abraded to remove all laitance, any trace of loose plaster,cement concrete , oil, grease, paints and any other materials are to be removed by wire brushing the surface. The entire surface shall then be washed thoroughly with plenty of water and then allowed to dry. Defective concrete surfaces cut back to a sound base by chipping and removed loose concrete. Smooth surfaces to achieve by chemically roughenedup to 10Mtr height including appling bond coat of epoxy bonding agent (Nito Bond) & cement in 1 : 1 ratio bonding old and new concrete on damaged surface and all necessary scaffolding and safety measuresall as specified and directed. .(The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
20M&L for cleaning to expose corruded reinforcement of chajja/beam/slab by wire brushing, emery paper or by mechanical means and to remove all loose scale and corrosion deposit and washing complete and providing additional reinforcementTMT bars of approved make, cut to length by electro welding method and applying one coat ofrust removing chemical and anti rust coating (zinc) along its full circumferenceup to 10Mtr height including all necessary scaffolding and safety measuresall as specified and directed.(Manufacturer name of chemical shall be: Fosroc/Sika/Pidilite/BASAF) The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
21M&L for providiing and placing high built repair ready mix concrete (Micro concrete) grade of M-50 specification and strengthconforming to ASTM- C109-99,ASTM- C 307 ,BS1881 Part 207 to expose corroded reinforcement ofchajja/beam/slab with bonding agent as per manufactures instruction (Manufacturer : Fosroc/Sika/Pidilite/BASAF) proper compaction and finished to proper level upto a depth of 25mmwith and including provision of formwork to the affected portionup to 10 Mtr height including all necessary scaffoldingall as specified and directed.(entire operation shall be done by the approved manufacturer or their authorized applicator and deemed to be included in the unit rate)
22Preparation of newly plastered surfaces on ceiling and applying three coats of white wash complete all as specified and as directed.
23M&L Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high complete all as specifed and as directed.
24Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
25Material and Labour for complete removal of existing treatment and applying two coats of cement-based paint, white or tinted over and including priming with alkali resistant priming paint to old plastered or unplastered surfaces on walls including preparation of surfaces, complete all as specified and directed.
26M&L forpreparation of newly plastered surfaces of walls, and applying two coats acrylic distemper on wall,over and including witha coat of 2 mm thick white wall care putty premiumquality over and including a coat of primernew plastered or unplastered surfaces on wall, complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
27M&L for complete removal of existing treatment from walls, and applying two coats acrylic distemper on walls,over and including2 mm thick white wall care putty premiumquality over and including a coat of primer to old plastered or unplastered surfaces on walls plastered or unplastered surfaces on walls complete all as specified and as directed.Make;Berger (Bison)/ J&N(Jensolin) /Asain Piants(Tractor)/ Nerolac(Beauty)
28M&L for preparing old decorated plastered or unplastered surfaces of wall, chajja , faciaincluding cornices, pilasters and other wall features etcby brooming down or steel wire brushing, scrapping down smokesoot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying one coat of100 % Acrylic Exterior Emulsionpaint (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shieldMaxBrand/J&N:Safeguard Optima Brand painting over and including a coat of primerto old plastered or unplastered surfaces
29M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etcby brooming down or steel wire brushing/sand paper, scrapping down smokesoot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and makinggood with putty as per existing thicknessand applying one coat acrylic distemper on old surfaces complete all as specifiedMake;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
30All as per item No : 29 here in beforebut on ceiling surfaces omplete all as specifiedMake;Berger (Bison)/J&N(Jensolin)/ Asain Piants(Tractor)/ Nerolac(Beauty)
31M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etcby brooming down or steel wire brushing/sand paper, scrapping down smokesoot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and makinggood with putty as per existing thicknessand applying two coat acrylic distemper on old surfaces complete all as specifiedMake;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
32Taking down Aluminium door window/ shutters n.exc 2 sqmand refixing in the same opening including making petty repairs as required like cleaning and repair/replacement of beadings, glazing clips, rubber gasket, stoppers, adjusting tower bolts, locks, hydraulic door closer, hinges etc and make smooth functioning with entire satisfaction of Engr-in-Charge complete all as specified and as directed .Note spare parts required to be replaced measured and paid respective item of BOQ
33Taking down Aluminium door shutters /window exc 2 sqmand refixing in the same opening including making petty repairs as required like cleaning and repair/replacement of beadings, glazing clips, rubber gasket, stoppers, adjusting tower bolts, locks, hydraulic door closer, hinges etc and make smooth functioning with entire satisfaction of Engr-in-Charge complete all as specified and as directed .Note spare parts required to be replaced measured and paid respective item of BOQ
34S&F forpivot suitable for Aluminiumshutter as per existing specfication including necessary fixing arrangments complete all as specified and as directed.
35S&F for EPDM gasket complete all as specified and as directed.
36S&F for rubber neoprene packing complete all as specified and as directed.
37S&F foranodised aluminium snap on beading/tapper clip for fixing the glass or particle board complete all as spcified and as directed.
38S&F for roller for sliding window complete all as spcified and as directed.
39S&F for sliding star lockfor sliding window complete all as spcified and as directed.
40S & F in repair double action concealed type floor springs (hydraulically regulated) made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel top cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
41S&F in repair exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 3, suitable for 61 kg to 80 kg mass of doors & 851 mm to 1000 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed.
42S & F in repair brass 4-levers Mortice lock, vertical type, size 100mm coplete all as specified and directed.
43Supply and Fix,4.8mm thick tinted glass of superior quality fixed to alluminium frame works with rubber beadingsn.exc 0.5 sqm of each pane with and including hacking out old broken glass (any thickness, size, quality or description) frommetal framecomplete all as specified and directed.
44S&F 25mm bore PVC coated MS conduit drapery rods, suitable for door/widows curtain with incl necessary fancy type dooms as approved by GE, and fitted to each end, brackets and fixed to wall complete all as specified and directed.
45S & F in repairstainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
46S & F mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed.
47Supply and Fix, in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring andwith overall length of cover plate 150 mm, fixed in floor, complete all as specified and directed.
48S&F in repairs Door seal (Snake guard) with Aluminium frame powder coated complete all specified
49S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches, wall and floor including all fitting complete all as specified and directed by Engineer- in- charge .
50All as per above item No.49 herein before but fixing only including all new fitting complete all as specified and directed by Engineer- in- charge .
51S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches, wall and floor including all fitting complete all as specified and directed by Engineer- in- charge .
52All as per above item No.51 herein before but fixing only including all new fitting complete all as specified and directed by Engineer- in- charge .
53S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
54S & F UPVC bends with inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
55S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
56Supply and fix PVC SWR Nahani/ Floor trap, multi inlet connection, plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
57S & FPVC-U, type B vent cowl for 110 mm bore pipe complete all as specified and as directed.
58S & FPVC-U, type Bvent cowl for 75 mm bore pipe complete all as specified and as directed.
59S & F UPVCbranch piece, single (single T) equal or unequal 110mm diawith inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
60M & L for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
61Supply and fixing of Grating round 125 mm size of PTMT. (Minimum weight 50gms) complete including jointing with solvent cement, all as specified & as directed.
62Supply and fixing of Grating round 125 mm size of PTMT. (Minimum weight 50gms)with waste ho;e complete including jointing with solvent cement, all as specified & as directed.
63S&F in repairs health faucet ((ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall 1.25 m long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified & as directed.
64S&F in repairstoilet paper holderwith flat recessed type stainless steel complete all as specified and directed
65Supply and Fix in repairs, brasschromium plated soap dish, ., fixed with brass chromium plated screws, complete all as specified and directed. (Make Jaquar Cat part No. AQN-7731/Marc/Kohler)
66Supply and Fix, brass CPfancy centre hole basinmixer for mixing hot & coldwater screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube inlcuding taking out unserviceable existing one complete all as specified and directed. (Makemixer cat part no. QQT-7169B of Jaquar or equivalent make Kohler/Marc)
67S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 32 mm dia with length not less than 900 mm connected to PVC waste fittings complete all as specified and as directed.
68M & L for PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
69S&F 500 ltrsIS markedmultilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) as per IS 12701: 1996hoisted and fixed in position withand including 20mm PTMT ballvalves high pressure with polythene float and nut with andincluding provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling exsiting one complete all as specified and directed .
70S&F 1000 ltrsIS markedmultilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) as per IS 12701: 1996 hoisted and fixed in position withand including 25mm PTMT ballvalves high pressure with polythene float and nut withincluding provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling exsiting one complete all as specified and directed .
71M&L for disconnecting existing tank setting aside for repairs,cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity andmouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.300 and not exc. 500 ltrs complete all as specified & as directed.
72M&L for disconnecting existing tank setting aside for repairs,cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity andmouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.500 and not exc. 1000 ltrs complete all as specified & as directed.
73S & F in repair20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
74Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed.(i) Complete removal of the existing water proofing treatment including padding (buid in cm/concrete) and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete(ii)Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) (iiii) Supply and Laying, chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction including all laps, cutting and waste in fabric reinforcement to PCC roof padding including providing 40 mm thick plain cement concrete (1:2:4) type B0using 12.5 mm graded aggregates as in roof padding.(iv) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement.(v) Waterproofing treatment over smooth finished surfaces after application of cold applied bituminous primer @ 0.30 Kg /Sq M,, providing and laying APP polymer, modified, non-woven polyester fabric of 150 grams/square metre, reinforced membrane, 3.00 mm thick, weighing 3.50 Kg / Sq M,by torch on application method, with minimum 75 mm overlap on longitudinal direction and 100 mm overlap on the transverse direction and finally applying with one coat of bituminous based solar reflective aluminium paint @ 100 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd. 3.APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionandLeak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted.Requisite guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion oftesting. The submission of both certificate is mandatory before issue of completion certificate.
75Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed.(i) Complete removal of the existing water proofing treatmentand removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete(ii)Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etcand Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iii) Applying bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384.(iv) One layer of APP based polymeric membranes of approved manufacturers,3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gms/sqm). Polymeric membrane shall be taken to cover the thickness of slab and shall be finished by a membrane flushing. Note: (i)Laying of APP based membranes shall be done by torch application or as per manufacturer"s instructions. (ii) Side overlaps shall be minimum 75 mm and the end taps shall be minimum 100 mm and sealing of all overlaps & joints as per manufacturer instruction. (iii)For parapets, membranes shall be taken to a height of minimum 60 Cm and then inserted to the parapet in a groove. The same shall be finished by a membrane flashing. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd. 3.APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionandLeak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted.Requisite guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion oftesting. The submission of both certificate is mandatory before issue of completion certificate.
76Supplying & fixing towalls , ceiling and laid in trenches20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
77Supplying & fixing towalls , ceiling and laid in trenches15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
78Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed.
79Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 20 mm bore complete all as specified and as directed.
80S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
81S & F in repairs in repairs thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating complete all as specified and as directed.
82S&F in repairs 15 mm nominal size, Swan Neck Pillar Cock , cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish all as per catalogue No.T4668A1 of Make Parryware or equivalent of Make mentioned under PS complete all as specified and as directed.
83Supply and Fix, brass chromium plated,towel rail, 20mm dia, , 60cm long between flanges,complete all as specified and directed.Make Cat no.ACN-1111NM of Jaquar or equivalent of Marc/Kohler
84Supply and Fix, bib tap, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, complete all as specified and directed.
85S & F in repairs 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed
86S & F in repair 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
87S & F in repair 15 mm nominal size, nonrising spindle type fancy angle cockas per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
88S & F vitreous china squatting pan, "Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
89S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
90S & F in repairs Counter Top(self-rimming) white basin vitreous china, white, , size 550x450x200 mm all as per catalogue No.C0431 Cascade NXT of Parryware or equivalent of Make mentioned under PSwith and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
91S & F 1800 mm X 1200 mm bevelled edge mirror of selected quality glass, mounted on 8 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
92S & F brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
93Supply and Fix, brass CPfancywall mixer with L bends (including provision of O/H shower & hand shower) for mixing hot & coldwater screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube inlcuding taking out unserviceable existing one complete all as specified and directed. (Make Hand shower cat part no. HSH-CHR-1717 and wall mixer cat part no. QQT-7281 of Jaquar or equivalent make Kohler/Marc)
94Removing of plants including roots by dismantling of brick work/PCC/RCC including necessary scaffolding, any type, any location/height (i.e roof, parapet walls near pipe etc) and applying acid after removing roots for preventing regrowth and making good the disturbed portion using PCC 1:2:4 Type B-0 and plaster in CM 1:3 (size of disturbed portion 150 x 150 x 150mm) complete all as specified and as directed by Engineer-in-Charge
95Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators sub main wiring, light fittingsetc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
96Taking down carefully copper/ aluminium submain wirings of any size (2/4/6 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
97Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit will be measured and paid as one unit length. (Note: Cost of cutting chase and making good shall be deemed to inclusive quoated rates .)
98Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit will be measured and paid as one unit length. (Note: Cost of cutting chase and making good shall be deemed to inclusive quoated rates .)
99M & L for concealed point wiringwith and including single core PVC insulated, unsheathed flexible conductor (FRLSH)cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor (FRLSH)cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter andrates of the samewill deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (a) Onelight point controlled by one switch 5 Amps
100(b) Onefan point/Exhaust fanpoint controlled by one switch 5 Amps
101Materials and Labour for concealed type point wiring with 4.00 Sq. mm (nominal area) (FRLSH)as per IS 694: 2010, ISI marked PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, drawn in andincluding medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 4.00 Sq. mm (nominal area) (FRLSH)PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(Note: (i) The chases in the wall shall be cut with elect cutter andrates of the samewill deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
102Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheetcover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for :- (i) Wiring to be done as per approved colour code in IE rule. (a) Onelight/Fan/Bellpoint controlled by one switch 5 Amps
103All as per item No :102 here in beforebut one One 3 Pin 5 Amps socket outlet independent
104All as per item No :102 here in beforebut one One 3 Pin 5 Amps socket outlet same board with other swicthes.
105Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.
106Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn into PVC casing and capping (PVC casing and capping with accessories will be measured and paid separately) and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for sub main, complete all as specified and directed.
107S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
108Supply and Fix, switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed.
109Supply and Fixswitch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed.
110S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
111Supply and Fixing in repairModular metal flush boxof 4 module including taking out unserviceable including make good to match with existingsurface complete all as specified and directed by EIC.
112Supply and Fixing in repairModular metal flush boxof 3 module including taking out unserviceable including make good to match with existingsurface complete all as specified and directed by EIC.
113Supply & fixing Modular white cover plate with frame 4 module including taking down unservieablecomplete all as specified and directed by EIC.
114Supply & fixing Modular white cover plate with frame 3 module ncluding taking down unservieablecomplete all as specified and directed by EIC.
115Supply & fixing Modular switch 1 way 6A, 1 module complete all as specified and directed.
116Supply & fixing modular switch socket combination3 pin 5 Amp , flush type complete all as specified and directed.
117Supply & fixing modular switch socket combination 16 Amp, 6 pin, 3 module complete all as specified and as directed.
118Supply and fixing in repairof stepped type Modular electronic fan regulator 2 module , 120 watt flush type , (deluxe) on the existing hylam laminated sheet etc as required. Make: Anchor (Deluxe /Code:-14502) / L&T/ Havells
119Supply & fixing in repair electronic dimmer, 450 watt, 250 volt flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
120S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
121S & F in repair double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.[Cat No. 5076 70 of Make Legrand or equivalent Model of Make L&T/ Seimens]
122S & Fin repair sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 8 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43,IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge. : Make-Legrand Cat Part No. 507611 or equivalent inSeimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
123S & F circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
124S & F circuit breakers (MCB), three pole(TP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
125S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
126S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
127S & F single pole and neutral enclosure with two pin and earth,plugand socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
128S&F LED 20 Watt tube light fitting(T8 type) ,single/double side connection type includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No Make :- Crompton (Batten Cat No :-IGP161LT8-16 box type batten suitable for 20 watt retofit LED tube single/double side connection type). LED lamp : Make : Crompton Cat No. LT8-20-865-(2) LED (retrofit LED tube lamp 20 Watt, Single /double end connection)or equivelent of make; Wipro/Philipscomplete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingincluding taking down old unserviceable complete all as specified & directed.. Note : Make of batten and LED tube lamp should be of same make.
129Taking down existing u/s CFL light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , white powder coated CRCA housing with LEDs, seam less front frame with flat white high transmission acrlyic cover, classic design with glare free soft illumination, cool white, having lumen efficacy not less than 100 Lumen/ watt including making electric connection from source with PVC sheathed copper conductor wireof 3 core x 1.5 Sqmm and fixing light in celing by all providing all arrangements complete all as specified and directed by Ein C. Make : Crompton Part No. LCTLRNE36FOCDL orequivalent in Philips/ Wipro
130S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-132-060-57-XX of Wipro or equivalent of Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
131Supply and fixing LED 3 watt Reading light, round cylindrical, 230 volt ACincluding taking down old unserviceablecomplete all as specified and as directed. Make- Glitz or equivalent.
132Supplying, installing, testing & commissioning, storage water heater (geyser), 25 litres capacity, standing loss less than 0.562 Kwh per day for 45°C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 4 years on heating element and 2 years on other spares parts comprising following fittings (a) glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16A capacity (i) drain plug (j) fusible plug fitted on the crown of water heater with operating temperature between 100°C to 110°C including fixing by grouting and fastener complete all as specified and as directed. (Note : Old unserviceable Geyserto be deposited in MES store yard)
133Supply and Fix, Heavy Duty Exhaust Fan, 300 mm sweep, 1400 RPM, Single Phase, 230 V, 50 Hz, all as per Model “Turbo Force” of Make ‘Havells’ or equivalent Model of Make ‘Bajaj’ /’Cromptron Greaves’/’USHA’ and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fanwith andincluding taking down existing old unserviceable exhaust fan any type and model,shall be deposited MES store by the contractor and received voucher to be obtainedand submitted alongwith RAR/Final Bill complete all as specified and directed by Eng in Charge.
134Supply and Fix, in repair Cable Junction Box, IP66 ‘halogen free and weather proof’, size 250 mm (L) x 200 mm (B) x 100 mm (H), suitable for cable size 16/25 sq mm, all as per Cat No GSJB-2520 of Make “SINTEX” or equivalent Model of Make ‘HENSEL’ ,fixed to wall/ pole with suitable FI clamp 20 X 3 mm, nuts, bolts and washers, including provision of 01 (One) No. miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA, 6 Amps and including provision of suitable cable lugs for two nos. incoming and one no. outgoing cable connections, complete all as specified and directed.
135S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 12 way, double door with 250 Amp, 25 KA,FP MCCB as incomer (Vertical type double door, 250 Amps, FP, 25 kAMCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make-Legrand Cat Part No. 507757 Model: (Ekinox-3) , MCCB 250 Amp Cat No., Model : DPX -3or equivalent inSeimens/ Schinder/ L&T Note : (i) MCCB and DB box shall be of same make.
136S & F stainless steel braided flexible connection pipe for hot and cold water supply for geyser, 15 mm bore, 450 mm length, 12 bar working pressure complete all as specified and as directed.