Repair / Maintenance Of Ht Vcbs, Station Transformer, Lt Distribution System, High Mast Light System, Solar Street Light Poles And Fittings, Maintenance Of Package Air- Conditioning System, rambilli-Andhra Pradesh

Military Engineer Services-MES has published Repair / Maintenance Of Ht Vcbs, Station Transformer, Lt Distribution System, High Mast Light System, Solar Street Light Poles And Fittings, Maintenance Of Package Air- Conditioning System. Submission Date for this Tender is 01-09-2022. Transformer Supply Tenders in rambilli Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33380457
Corrigendum : Repair / Maintenance Of Ht Vcbs, Station Transformer, Lt Distribution System, High Mast Light System, Solar Street Light Poles And Fittings, Maintenance Of Package Air- Conditioning System
Open Tender
Indian
Andhra Pradesh
rambilli
01-09-2022

Tender Details

Repair / Maintenance Of Ht Vcbs, Station Transformer, Lt Distribution System, High Mast Light System, Solar Street Light Poles And Fittings, Maintenance Of Package Air- Conditioning System

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Aug-2022 BOQ BOQ 25-08-2022
2 25-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

Name of Work: Repair/maintenance of HT VCBs,StationTransformer, LT distribution system , High mast light system, Solar street light poles and fittings, maintenance ofpackage Air- conditioning system, coolingappliances, internal electrification including comprehensivemaint ofEOT 5.0 TONcrane and other allied E/Mservices of MRS at AOB Rambilli near Visakhapatnam
Sl. No. Item Description
1Overhauling and servicing of OLTC unit for LT transformer of capacity 11000V /433V500 kVA comprising the following.Parts complete all as specified and directed by Engineer in charge. (i)Servicing of all mechanical gear wheels and moving parts, latches and releasing parts, over driven stoppingand restarting mechanism complete. (ii) Cleaning of complete OLTC control chamber and fault finding. (iii) Repairing to control wiring,replacement of burnt wires,lugs etc . (iv ) Lubricating,greasing of all mechanical parts. (v) Servicing to electrical auxialary contactors and limit switches and HRC fuses complete.
2M&L for supply and filling silica Gel into the breather of transformers complete all as specified and directed by Engineer in charge.
3M&L for cleaning of out door sub-stations and removing of vegitations from existingaggregatesincluding cutting of bushes / plants arround the compound wall (Inside & outside) and disposal of waste materials complete all as specified and directed by Engineer in charge.
4M&L for fabricate cabinet of the battery Charger suitable for 110V/200AH battery charger including taking down old rusted battery cabinetcomplete all as specified and directed .
5S&F in replacementSensing board,Micro Board,firing board,Smart switch with its fixing arrangementsuitable for 110V battery Charger complete all as specified and directed by Engineer in charge.
6S&F in replacement AC/DC converter transformersuitable for Battery charger 110V/200 AH 50 Amps complete all as specified and directed by Engineer in charge.
7M&L for Decarbonising / cleaningof HT 11KV VCB ,bus bar chamber, all electrical connectionsafter removing the bus bar spout, cleaning with petrol and CRC 226 spray solution and ensure proper de-carbonisation, refixing the same after cleaning complete all as specified and directed by Engineer in charge.
8S&F in replacement LC Filter (Chokes & capacitors)suitable for Battery charger 110V/200 AH 50 Amps with connecting acessories complete all as specified and directed by Engineer in charge.
9S&F in replacement semi conductor Fuses 7 filter fusessuitable fot Battery charger 110V/200 AH 50 Amps including connecting acessories complete all as specified and directed by Engineer in charge.
10S&F in replacement dual block SCR suitable for 110V/200 AH 50 Amps Battery charger complete all as specified and directed by Engineer in charge.
11S&F in replacement AC & DC Input contactors and its acessories for 110V/200 AH 50 Amps Battery charger complete all as specified and directed by Engineer in charge..Make Amara raja power sysytem or Equivalent
12M&L fo replacement of air break switch triple pole, manually/mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current ratingupto 400 Amps11 KV grade complete all as specified and as directed by Engineer in charge.
13Dismantling and taking old existing earthing pit including necessary disconnections of earth strip and Material and labour for provisioning of new earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper earth strip of 20x 3mm dia means of nut, bolts and washers made out of galvanized iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to HT Structures,VCBs or Transformer etc or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C1 pre-cast cover RCC cover lab of size 380 x 380 x 50 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plate No.3 and testing complete including bringing the earth resistance value within the limit and shown to the Engineer -in- Charge at site.
14All as per Serial Item No. 13 here-in-before but forGI strip of 32X6 mm
15S&F in replacement insulated synthetic mat nominal 3.0mm thick colour blue confirming to IS 15652:2006 suitable up to 11 KVcomplete all as specified and as directed by Engineer in charge.
16S&F in replacement 2V DC VRLA cell arrange properly with connecting leads inside battery rack complete all as specified and as directed by Engineer in charge.Make Amara raja power sysytem or Equivalent .
17M&L for fabricatedbattery Rack suitable for 110V/200AH -55 Nos including taking down old rusted battery rack complete all as specified and as directed by Engineer in charge.
18Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying cables/ pipe line etc. and getting out in soft/ loose soil.complete all as specified and as directed by Engineer in charge.
19Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed by Engineer in charge.
20Removing excavated materials to a distance n. exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point complete all as specified and as directed by Engineer in charge.
21Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed by Engineer in charge. (Note: Punned thickness only shall be measured)
22Supply and laying un-reinforced precast concrete cable cover, class HV,Type 1 flat,size 300X180X40mm complete all as specified and as directed by Engineer in charge.
23Supply, laying, testing and commissioning of HT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip or wire armoured electricpower cable [heavy duty] of size 3 core x 400.00Sqmm, with stranded aluminium conductor, 11000 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc including taking down old unserviceable cable complete all as specified and as directed by Engineer in charge.
24All as per Serial Item No. 23 here-in-before but for cable of size 3 core x 300.00Sqmm.
25All as per Serial Item No. 23 here-in-before but for cable of size 3 core x 240.00Sqmm.
26All as per Serial Item No. 23 here-in-before but for cable of size 3 core x 185.00Sqmm.
27All as per Serial Item No. 23 here-in-before but for cable of size 3 core x 120.00Sqmm.
28M&L for Cold shrinkable HT 11 KV (earthed) straight through joint suitable for aluminium conductor cable of size 3 core 120 to 185sq.mm including taking down old unserviceable complete all as specified and as directed by Engineer in charge.
29M&L for Cold shrinkable HT 11 KV (earthed) indoor/outdoor type cable end jointsuitable for aluminium conductor cable of size 3 core 185sq.mm to 400 Sqmm including taking down old unserviceable complete all as directed.
30M&L for Cold shrinkable HT 11 KV (earthed) straight through joint suitable for aluminium conductor cable of size 3 core 240 to 400sq.mm including taking down old unserviceable complete all as specified and as directed by Engineer in charge.
31M&L for preparation of old painted surface, cleaning of surface portion complete for 16/11/9 /8.5 mtrs long pole above PCC coping with applying one coats of aluminium paint including brackets,clamps and terminal boxes and writing MES Nos of poles (number size shall be 25mm and lettering shall be 40mm) complete all as specified and as directed by Engineer in charge.
32All as per Serial Item No. 31 here-in-before but for four pole structure of HT/LT includind bracings, cross arms etccomplete all as specified and as directed by Engineer in charge.
33Disconnecting transformer of capacity 500 KVA indoor/ out door from HT/ LT side at site, dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing 5mm thick rubberized cork sheet gasket for tank top cover and re assembling the completere connecting the HT/ LT supply cable ends at the site complete all as specified and as directed by Engineer in charge.
34Taking out unserviceable defective HT bushings from transformers and S&F porcelain bushing with brass studs, nuts and washers connected to winding, testing and commissioning the transformer of capacity 500 KVA complete all as specified and as directed by Engineer in charge.
35All as per Serial Item No. 34 here-in-before but forLT bush for transformer of capacity 500 KVA.
36M&L for rewinding of HT/ LT transformers of capacity 500 KVA by winding the defective coils with new copper wire as per IS of same gauge and existing size together with new insulated materials and aluminium bracings before placing in to the transformer and assembling the HT/ LT coil with new insulation between core and LT coil and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as specified and as directed by Engineer in charge.
37M & L for servicing LT distribution panels completecleaning of panel with CTC and bus bar Chamberwelding of hingesincl checking ofincoming and out going connections and renewal of unserviceable switch fuse unit switch disconnector fuses/MCCB"s, Frame works, including of two coats of synthetic enamel paint complete all as specified and as directed by Engineer in charge.
38M&L for control wring of LT panel boards of capacity up to 630 Amps including replacement of 2.5 Sqmm stranded copper conductor such as volt/ ammeter, selector switches, indication lamps, ACBs, Relays, contacts, CTs including all necessary connections complete all as specified and as directed by Engineer in charge.
39M & L for preparation ofold painted surfaces of HT/LT transformers of capacity 500 KVA including removing oilly and greasy spots and applying one coats of synthetic enamel paint including white wash to transformer foundation plinth and lettering with white paint as MES NO/SM No, capacity, year of installation, serial No over coat on black paint complete all as specified and as directed by Engineer in charge.
40M & L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed by Engineer in charge.
41All as per Serial Item No. 40 here-in-before but for HT, 25x20cm size
42Decorbonising/cleaningcapacitor bank panel, Rewiring electrical connections complete installed in various sub-stations after removing the complete chambar cleaning with CTC and ensure proper decorbonising, refixing the same after applying bectol RED solutions and checking all the connections and tightining the nut, bolts, system complete including replacement of defective rusted bolts ,nuts, washers,auto / manual selector switchs, ON / OFF switch buttons with elements etc acomplete all as specified and as directed by Engineer in charge.
43Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip or wire armoured electricpower cable [heavy duty] of size 3.5core x 300.00Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc.,including taking down old unserviceable cable complete all as specified and as directed by Engineer in charge.
44All as per Serial Item No. 43 here-in-before but for cable of size 3.5 core x 95.00 Sqmm.
45All as per Serial Item No. 43 here-in-before but for cable of size 3.5 core x 50.00 Sqmm.
46All as per Serial Item No. 43 here-in-before but for cable of size 4.0 core x 25.00 Sqmm.
47All as per Serial Item No. 43 here-in-before but for cable of size 4.0 core x 10.00 Sqmm.
48Taking down old unserviceable Multi-fuctioning meters and S&F newMulti- function meter ( Voltage, current, PF) display of size 96x96 sqmmor suitable to existing at site complete all as specified and as directed by Engineer in charge.
49M & L for Current Transformer siutable for HT11KV Ring Main Unitas per existing make or equivalent in approved makes including taking down old unserviceable one completeall as specified and directed.
50S&Findication lamps 110/ 230V AC/DC with threaded type holderwith integral LED indication lamps 230v of 22.5mm dia holder suitable for R-Y-B phases complete all as specified and as directed by Engineer in charge.
51M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of primer and one finishing coat of paint including taking down old complete all as specified and as directed by Engineer in charge.
52S&F in repair Isolating contact Finger type suitable for 800 Amps VCB of existing make complete all as specified and as directed by Engineer in charge.
53S&F in repairIsolating contact Finger typesuitable for 1600 Amps VCB of existing make complete all as specified and as directed by Engineer in charge.
54S&F in repairIsolating contact Flat type suitable type 630/800/1250Amps VCB of existing make complete all as specified and as directed by Engineer in charge.
55S&F in repair Isolating contact Flat type suitable for1600 Amps VCB of existing make complete all as specified and as directed by Engineer in charge.
56S&F in repair Isolating contact flat type suitable for VCB 2000 Amps of existing make complete all as specified and as directed by Engineer in charge.
57Supply, install, testing and commisioning in replacement of Vacuum interrupterVG 2R variantof of existing make complete all as specified and as directed by Engineer in charge.
58Supply, install, testing and commisioning in replacement of Vacuum interrupterVG4 variantof of existing make complete all as specified and as directed by Engineer in charge.
59Supply, install, testing and commisioning in replacement of daspot assemblycomplelte of of existing make complete all as specified and as directed by Engineer in charge.
60Supply, install, testing and commisioning in replacement of shutter for racking shaft of existing make complete all as specified and as directed by Engineer in charge.
61Supply, install, testing and commisioning in replacement of manual inter lock handle of dia 6mm of existing make complete all as specified and as directed by Engineer in charge.
62S & F in replacement closing coil of varients 24V DC CN 1346 of existing make complete all as specified and as directed by Engineer in charge.
63S & F in replacementrelease coil of varients30V DC,CN 1347of existing make complete all as specified and as directed by Engineer in charge.
64S &F in replacementclosing coil of varients50V DC, CN 1348 ofof existing make complete all as specified and as directed by Engineer in charge.
65S & F in replacement of releasecoil of varients 110V DC,CN 1349 of existing make complete all as specified and as directed by Engineer in charge.
66S &F in replacement of releasecoil of varients 220V DC,CN 1351 of existing make complete all as specified and as directed by Engineer in charge.
67S &F in replacement of breakerswitch 12 way( 6NO+6NC) of existing make complete all as specified and as directed by Engineer in charge.
68S &F in replacement of breaker auxillary switch16way(8NO+8NC) of existing make complete all as specified and as directed by Engineer in charge.
69S &F in replacement of breaker auxillary switch 20way(10 NO+10 NC) of existing make complete all as specified and as directed by Engineer in charge.
70S &F in replacement of Phase Bus Bar Spout Assembly for 800A capacity HT VCB 660MM panel with necessary fixing arrangements of existing make complete all as specified and as directed by Engineer in charge.
71S &F in replacement of R/B Phase Bus Bar Spout Assembly for 2000A capacity HT VCB 860MM panel with necessary fixing arrangements of existing make complete all as specified and as directed by Engineer in charge.
72S &F in replacement ofY Phase Bus Bar Spout Assembly for 2500A/3150A capacity HT VCB 860MM panel with necessary fixing arrangements of existing make complete all as specified and as directed by Engineer in charge.
73S &F in replacement of 3 Phase Circuit Spout for 800A Panel, CT Chamber Arrangement for 800A HT VCB Panel with necessary fixing arrangements of existing make complete all as specified and as directed by Engineer in charge.
74S &F in replacement of 1 Phase Circuit Spout for 800A Panel, CT Chamber Arrangement for 1600A/2000A HT VCB Panel with necessary fixing arrangements of existing make complete all as specified and as directed by Engineer in charge.
75S &F in replacement of Racking Screw-660MM Panel of existing make complete all as specified and as directed by Engineer in charge.
76S &F in replacement of Racking nut 20mm Panel of of existing make complete all as specified and as directed by Engineer in charge.
77S &F in replacement of Rack-in-Rack out Socket upto 3150A HT VCB Panel of of existing make complete all as specified and as directed by Engineer in charge.
78S &F in replacement of mannual spring Charging handle unit upto 3150A HT VCB Panel of existing make complete all as specified and as directed by Engineer in charge.
79S &F in replacement of earthing truck/earthing switch operating handle upto 3150A HT VCB Panel of existing make complete all as specified and as directed by Engineer in charge.
80S &F in replacement ofearthing socket upto 3150A HT VCB Panel of existing make complete all as specified and as directed by Engineer in charge.
81S &F in replacement of earthing nut upto 3150A HT VCB Panel of existing make complete all as specified and as directed by Engineer in charge.
82S &F in replacement of Shutter Assembly for Bus Bar /circuit spout -660 (AluZn sheet) of existing make complete all as specified and as directed by Engineer in charge.
83M & L for Potential Transformer siutable for HT11KV Ring Main Unit as per existing make or equivalent in approved makes including taking down old unserviceable one completeall as specified and directed.
84S &F in replacement of limit Switch-1NO+1NC service/ test position of existing make complete all as specified and as directed by Engineer in charge.
85S &F in replacement of thermostat for Space Heater of existing make complete all as specified and as directed by Engineer in charge.
86M&L forunder ground Fibre optic cable RJ-45 confirming to G-652 .including taking downold unserviceablecable complete all as specified and as directed by Engineer in charge old unserviceable cable.
87M&L for rewinding of outdoor duty isolator motorby winding the defective coils with new copper wire as per IS of same gauge and existing size together with new insulated materialsand assembling complete all as specified and as directed by Engineer in charge.
88S &F in replacementcharger of solar lighting system based on 100/110Watt panel all as specified and directed
89S&F inreplacement of 24 Watt LED luminaries with HF drive suitable completeall as specified and directed
90M&L for replacement of battery capacity of 12v 40AH suitable for solar lighting system based on 100/110Watt panel all as specified and directed
91M&L for servicing/repairing of 11 TR air cooled ductable split air conditioner unit of capacity 5.5 TR with scroll compressor from its existing position and refixing of the same after repairing including/cleaning filter removing internal dust by using air blower and vacuum cleaner, oiling, greasing wherever required including checking / testing after completion all as specified and as directed. Note : Unserviceable/defective items like drain pipes,filters,canvas coupling etc which are required to be replaced shall be inclusive of quoted rates.
92M&L for Charging of refrigeration gas R-410Aany description, any makemakeup required pressure to 11 TRductable split ACall as directed.
93M&L for servicing/repairing of water cooler of capacity 40/40ltrs from its existing position and refixing of the same after repairing including/cleaning filter removing internal dust by using air blower and vacuum cleaner, oiling, greasing wherever required including checking / testing after completion all as specified and as directed. Note : Unserviceable/defective items like drain pipes,nut and bolts,base supporting parts etc. which are required to be replaced shall be inclusive of quoted rates
94M&L for finding the leakage in refrigerant system by nitrogen pressure test etc and rectifying the leakage by brazing including installation andtesting of the water cooler capacity 40/40 ltrs complete all as specified and as directed by Engineer in charge.
95M&L for Charging of refrigeration gas (R-22/134a/ HCFC ete ) to existingWindow AC/ Split AC /Deep Freezer/Deepe/Refrigerator of any description, any make & in any position to makeup required pressure all as directed.
96S&F Starting capacitor of 80/100 mfd capacity.complete all as specified and as directed by Engineer in charge.
97S&F Starting capacitor of 100/120 mfd capacity complete all as specified and as directed by Engineer in charge.
98S & F Running capacitor of 4.5 MFD complete all as specified and as directed by Engineer in charge.
99S&F Running capacitor of 30 MFD/36 MFD capacity complete all as specified and as directed by Engineer in charge.
100S&F Starting capacitor of capacity 10 MFD/20MFDcomplete all as specified and as directed by Engineer in charge.
101S&F Running capacitorof 4 MFD complete all as specified and as directed by Engineer in charge.
102S&F Thermostat switch for water cooler Make : Renutral/Shriram/Indfoss complete all as specified and as directed by Engineer in charge.
103S&F PCB for ductable spilt AC Split Ac.as per existing make complete all as specified and as directed by Engineer in charge.
104S&F Brass service valve for split typeA/C of size5/8” or 3/8"" dia service valve complete all as specified and as directed by Engineer in charge.
105M&L for replacement of 3 core flexible copper cable of size 40/0.0076 with thimble etc complete all as specified and as directed.
106M&L for burnt compressor including dismantling the unserviceable burnt afterdisconnecting suction/discharge side copper tube bolts rubber pads and washers connecting copper tubing by welding blazing nut flaring and repairing of gas leakage if any and complete suitable for 5.5 TR ductable split AC all as specified and as directed.
107M&L for replacement of blower fan motor of existing size and capacity in cooling unit of split type AC capacity 5.5 TRcomplete all as specified and as directed by Engineer in charge.
108M&L for replacement of Condensor fan motor of existing size and capacity in outdoor unit of split type AC capacity 5.5 TR complete all as specified and as directed by Engineer in charge.
109M&L for replacement of copper tube of size 1/4" or 3/5"" dia for cooling unit to condensing unit for split Acs complete all as specified and as directed by Engineer in charge.
110All as per Serial Item No. 108 here-in-before but of size 1/2"" or 5/8" dia.
111M&L for replacement ofinsulation for copper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia for cooling unit to condensing unit for split Acs all as completeall as specified and directed.
112M&L for writing/making SL, SM, MES Nos with black/white paint with stencil on indoor and outdoor unit of split Acswater cooler , stabilizers of any make and any capacity completeall as specified and directed.
113M&L for replacement of metal clad socket outlet 3 pin of capacity 20 Amps240V complete all as specified and as directed.
114M&L for replacement of metal clad plug top of capacity 20 Amps, 240Vcomplete all as specified and as directed.
115M&L for replacement of float valve 15mm bore of brass with L type nipple & polythene float valve complete all as specified and as directed.
116M&L for 16m high mast light wiring kit alongwith connector complete all as specified
117S&F inreplacement of 150 Watt LED luminaries for highmast lighting system with HF drive suitable completeall as specified and directed
118S&F inreplacement UV/IR detector of make Ravel/Agni or equivalent complete all as specified
119S&F inreplacement Control module for monitoring field device, operation voltage 17 to 28V complete all as specified and directed.
120M&L for Comprehensive maintenance and repairs of EOT 5.0 Ton crane capacity, M/s Tojyam make of theGIS building,AOB Rambilli for periodic maintaining with collective/selective control schedule in by carrying out periodic checks,repair and testing as recommended bymanufacturer/OEM and as directed by the Engineer in charge to ensure smooth/safe and efficient operation,including supplying and fixing of spares complete all as specified and directed. The quoted rates shall be inclusive of following. (i) One crane mechanics along with helper should be available during working hours of crane (0900 hr to 1700hr) including required spares for maintenance. (ii) The necessary major/minor spares required such as breaking oil, brake bands, brake shoes liner, gear shaft, limit switches, VFD drive, power contactors,shrouded busbar, pendant push buttons,steel wire ropes,repair/rewinding of existing motoretc. (iii)Carrying out load test once in 11 month on EOT crane 5 Ton capacity under 110 % of full load capacity of crane hoisting,long travel and cross travel for checking the performance including deflection test with necessary man power,instruments,the loads required with necessary transportation up to required crane complete all as directed. Deflection test for EOT crane shall be carried by the contractor through licencec crane inspector in presence dept rep as directed by GE and recording of test results and certificate will be issued by the same. (iii)Prepairing of Surfaces EOT crane complete including end carriages,double and single gantry,motors,gear box,blocks,platform structure,gantry girders etc by scrapping,cleaning using wire brush,sand paper etc. and painting one coat of synthetic enamel paint over one coat of primer of approved color.
121S&F in replacementMCCB of capacity 4 pole 400 amps MCCB, 36 KA complete all as directed
122S&F in replacementMCCB of capacity 4 pole25 to 100 amps MCCB, 25 KA complete all as directed
123S&F in replacementMCCB, 200 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 36 KA with adjustable load setting from 70 % to 100 % complete all as directed.
124S&F in replacementMCCB of capacity 4 pole125 amps MCCB, 25 KA complete all as directed
125Repairs/ servicing to incoming 4 pole 65 KAACB 1000Amps capacity by replacing contactor coil including all necessary spares as required and directed
126S&F in replacement Galvanised steel water tubing 50mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc)laid in trenches,including testingcomplete all as specified and as directed.
127S&F in replacement of 25mm bore High Density polythene pipes (HDPE)pressure rating 6kgf/sqcmcomplete all as specified and as directed.
128S&F in replacement Galvanised steel water tubing 25mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc)laid in trenches,including testingcomplete all as specified and as directed.
129S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends, suitable for iron pipe of 25mm bore dia of pipe,including taking down old unserviceable one complete all as specified and as directed.
130S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends, suitable for iron pipe of 50mm bore dia of pipe,including taking down old unserviceable one complete all as specified and as directed.
131M & L for Rewiding of Ceiling fan of size 1200mm sweep of any make with super enameled copper wire of suitable existing size gauge, insulating, varnishing, heating and reassembling and refixing in buildings locations where ordered all as specified and directed by Eng-In-Charge incl testing.
132M & L for Rewiding of Exhaust/Wall/Cabin fan of size300mm to 450mm sweep of any make with super enameled copper wire of suitable existing size gauge, insulating, varnishing, heating and reassembling and refixing in buildings locations where ordered all as specified and directed by Eng-In-Charge incl testing .
133S&F in replacement of20watt LED batten surface light fitting 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose
134S&Fin replacement Energy saving, environmentally friendly & robust High bay light LED 50 Watt energy efficient, P.F>0.95, >100 lum/watt, with and including LED light driver holder connecting of with three core flexible copper conductor cable of suitable size, complete all as directed by Engr-in-charge.
135M&L for replacement of T-5mirror optics 2x28 watt. Including tube rodnecessary required complete all as specified and directed by Eng-In-Charge.
136M&L for replacement to T-5surface light fitting 2x28 watt. Including tube rod/bulbnecessary required complete all as specified and directed by Eng-In-Charge.
137M&L for repairs to surface light fitting 1x28 watt.Including tube rod/bulbnecessary required complete all as specified and directed by Eng-In-Charge.
138Material and labour for point wiring with PVC insulated 1.5 sqmm FR multistrand copper conductor cable (Phase - Red, Neutral - Black) 1100 volts grade drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm diaISI marked ivory colour with all conduit fittings and fixing accessories including sunken galvanized pressed steel terminal boxes of thickness 1.12 mm covered with 3 mm thick phenoliclaminated white sheet cover for mounting electrical fittings, fixtures, accessories etc and 1.0 sqmm FR multistrand copper conductor cable (Green) as continuous earth wire including taking down of old u/s surface / concealed points/fittings complete for the following :- (i) One light/fan point controlled by one switch.
139All as per Serial Item No. 138 here-in-before but for One socket outlet 6 amp controlled by one switch on the same board.
140All as per Serial Item No. 138 here-in-before but for One socket outlet 6 amp controlled by one switch on the independent board.
141S&F in replacement switch socket combination modular2 in 1, 6 pin 5 & 15 amp flush type complete.
142S&F in replacement of Ceiling rose, 3 terminals PVC/Polycarbonate, Single phase, isolated body, complete all as specified and as directed.
143S&F in replacement of modular switch with indicator lamp single pole one way 16 amp complete all as specified and as directed.
144S&F in replacement of modular switch with indicator lamp single pole one way 6 amp complete all as specified and as directed.
145S&F in replacement of socket outlet modular 6 amp, flush type complete all as specified and as directed.
146Supply & fixing post top lantern light fitting moulded plastic capsul with housed ballast, lamp holder baffler for glare control suitable for 1X18 LED Watt lamp including taking down unserviceable existing complete all as specified.
147M&L for extension of GI Strip of size 32 x 6 mm for transformer neutral and body earthing with suitable size nuts, bolts and washers complete all as specified and as directed.
148M&L for extension of GI Strip of size 50 x 50 mm for transformer neutral and body earthing with suitable size nuts, bolts and washers complete all as specified and as directed.
149M&L for extension of GI Strip of size 75 x 75mm for transformer neutral and body earthing with suitable size nuts, bolts and washers complete all as specified and as directed.
150To find out the electric fault in HT under ground cable by fault locating kit and technician to be hired by the contractor for find out the exact fault location as per safety manner and earth work upto 3m depth is also inclusive in quoted rate wherever required all as specified and directed by Engr-in-Charge. Note:- Technician should be well knowledge and experience in fault locating kit for using all command and controls.
151All as per Serial Item No.149 here-in-before but for LT under ground cable .
152Supplying and replace MCCB, 250 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 35/36 KA with adjustable load setting from 70 % to 100 % complete all as specified and as directed by Engineer in charge.
153Supplying andreplace MCCB, 160 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 36 kA with adjustable load setting from 70 % to 100 % complete all as specified and as directed by Engineer in charge.
154S&F in replacementMCB ofcapacity 32 Amps DP 240 Volt AC complete all as specified and as directed by Engineer in charge.
155S&F in replacement MCB ofcapacity 6 to 32 Amps SP 240 Volt AC complete all as specified and as directed by Engineer in charge.
156M&L for Cable route indicator for cable route marker, made out of cast iron round shape of 100mm dia, with supporting length of MS angle 40x40x6mm and 750mm long fixed with nuts & bolts, duly marked with word such as HT /LT Cable as directed, duly painted with two coats of super enamel silver colour over a coat of primer, including grouting in ground 300mm x 300mm x 300mm deep with and including PCC 1:2:4 (Type B1), complete all as specified and directed.
157S&F in replacement of perforated GI cable tray 2mm thick of size 300X100mm including nut and bolts, joining complete all as directed
158M&L for multicore Copper conductor cables, PVC insulated,LT1100 Volts and GI strip/wire armoured laid in ducts/on structures.cable trays incl clamps, terminations on both ends with glands and connecting upto the equipment of size 5 Core 2.5 Sqmm including taking down old unserviceable one complete all as directed
159All as per Serial Item No. 158 here-in-before but for of size 4 Core 2.5 Sqmm complete all as directed
160Total Amount in Figures
161Quoted Amount in Words