01- Supply Of Capacitor Panel 100 Kvar Each With Harmonic Filter And Reactor- Season 2022-23 01- Supply Of Capacitor Panel 100 Kvar Each With Harmonic Filter And Reactor- Season 2022-23 , 4 X 25 Kvar= 100 Kvar Self Heeling Type ( May Be Connected To Apf, meerut-Uttar Pradesh

Uttar Pradesh State Sugar Corporation Limited has published 01- Supply Of Capacitor Panel 100 Kvar Each With Harmonic Filter And Reactor- Season 2022-23 01- Supply Of Capacitor Panel 100 Kvar Each With Harmonic Filter And Reactor- Season 2022-23 , 4 X 25 Kvar= 100 Kvar Self Heeling Type ( May Be Connected To Apf. Submission Date for this Tender is 01-09-2022. Copper Wire Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33369376
Corrigendum : 01- Supply Of Capacitor Panel 100 Kvar Each With Harmonic Filter And Reactor- Season 2022-23 01- Supply Of Capacitor Panel 100 Kvar Each With Harmonic Filter And Reactor- Season 2022-23 , 4 X 25 Kvar= 100 Kvar Self Heeling Type ( May Be Connected To Apf
Open Tender
Indian
Uttar Pradesh
meerut
01-09-2022

Tender Details

01- Supply Of Capacitor Panel 100 Kvar Each With Harmonic Filter And Reactor- Season 2022-23 01- Supply Of Capacitor Panel 100 Kvar Each With Harmonic Filter And Reactor- Season 2022-23 , 4 X 25 Kvar= 100 Kvar Self Heeling Type ( May Be Connected To Apfc Panel ) Capacitor Bank In Crca Sheet Steel2.00 Thickness Enclosure / Housing Panelalongwith 3 Phase, 415 / 440 V, 7%Detuned Copper Bounedharmonic Filter / Reactanceconfirming To Iec 61558-2-20&Iec 60076-6, H Class Insulation ( 180 Deg.C ) , High Temp. Disconnection Above 155 Deg. C, Ambient Temp. +60 Deg. C With Thermal Cut Off Switch With 525 V Alluminium Bus Bar Should Be 4 Pole, Exhaustfans.Wiring Should Be In Copper Wire , Separateinternal & Externalterminal For Connection Should Be Provided Reactance% As Required For Each Paneltoovercome Harmonics, Linearity % Of Harmonic Filter-Upto 200% With Guranteecertificate.All Measuring Meters Like Amperemeter, Voltmeter, Pf Meter & Kwh Meter Etc& Indicating Lamps. Shunt Capacitor Bank Specifications:- App Heavy Duty& Ip20 Mpp Type Super Heavy Duty Confirming To To Is:13340-41 / Iec60831-1&2 , The Capacitor Shall Be Fitted With Discharge Resistor, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50Hz Operating Loss Should Be Less Than 0.25Watt Per Kvar , Min. Over Current Capacity 1.8 Times Rated Current & Peak Inrush Current Min 300Times Of Rated Current , 525 V Should Life Expentency Min 165000 Hrs. ( Rates May Be Quoted Sepratly ) Rating- 2X25 Kvar At- 440 V, 525V As Req. With Reactance Freq.- 50Hz Connection – Delta, Ins. Class-H Ins. Level – 315 Kv, Siemens, Snieder, / Neptune.Price Should Be Quoted Make Wise Of Capacitors , Note: , Please Enclose A Copy Of Company Prevailing Price List With Tender Form Duly Signed And Stamped If Applicable. , Quantity May Be Increased Or Decreased At The Time Of Placement Of Order.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Aug-2022 Date Extend Corrigendum Date 17-08-2022
2 17-Aug-2022 Date Corrigendum Date 22-08-2022
3 22-Aug-2022 Date Extended Date 29-08-2022
4 29-Aug-2022 Date Extend Date 01-09-2022

Key Value

Document Fees
INR 590 /-
EMD
INR 25000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SUPPLY OF CAPACITOR PANEL 100 KVAR EACH WITH HARMONIC FILTER & REACTOR- SEASON 2022-23
Sl. No. Item Description
14 X 25 KVAR= 100 KVAR Self heeling type (may be connected to APFC panel)Capacitor Bank In CRCA Sheet Steel2.00 thickness Enclosure/Housing Panelalongwith 3 phase, 415/440 V, 7%Detuned Copper BounedHarmonic Filter/Reactanceconfirming to IEC 61558-2-20&IEC 60076-6,H Class insulation(180 deg.C),High temp. Disconnection above 155 deg. C, Ambient temp. +60 deg. C with thermal cut off switch with 525 v Alluminium Bus bar should be 4 pole, ExhaustFans.wiring should be in copper wire , separateinternal & externalterminal for connection should be provided Reactance% As required for Each Paneltoovercome Harmonics, Linearity % OF Harmonic Filter-upto 200% with guranteecertificate.All measuring meters like amperemeter, voltmeter,pf meter & kwh meter etc& indicating lamps. Shunt Capacitor bank Specifications:- App Heavy Duty& IP20 mpp type super heavy duty confirming to to IS:13340-41/ IEC60831-1&2 , The Capacitor shall be fitted with discharge resistor, pressure sensitive disconnector ( psd) and shall have dissipation factor less than 0.0025 at 50HZ OPERATING LOSS Should be less than 0.25watt per kvar , min. over current capacity 1.8 times rated current & peak inrush current min 300times of rated current , 525 v should life expentency min 165000 hrs. ( rates may be quoted sepratly) Rating- 2x25 KVAR at- 440 V,525V As req. with reactance Freq.- 50Hz Connection – DELTA,ins. Class-H INS. LEVEL – 315 KV, Siemens, Snieder,/NEPTUNE.Price should be Quoted make wise of capacitors
2Note:
3Please enclose a copy of company prevailing price list with tender form duly signed and stamped if applicable.
4Quantity may be increased or decreased at the time of placement of order.