| Sl. No. | Item Description |
| 1 | Earthwork in excavation in alltypes of soil for site leveling, foundation, pits, trenchesand other civil works upto and including 1.5 metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. (All type of Soil) |
| 2 | Hard Rock |
| 3 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-In-charge. |
| 4 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction ofEngineer-In-charge. |
| 5 | Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand : 8 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. |
| 6 | Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portlandslag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
| 7 | Providing and lying plain cement concrete of proportion (1:2:4) in foundation and floors using Portlandslag cement (PSC) with 12 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
| 8 | First class Fly Ash Brick masonry usingF.A. bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
| 9 | First class Fly AshBrick masonry using F.A. bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement (PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
| 10 | First class Fly Ash Brick masonry using F.A. bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge |
| 11 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 200 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
| 12 | Column up to plinth lvl. |
| 13 | Pedestal |
| 14 | Cloumn up to NGL |
| 15 | Plinth beam - At Plinth Level |
| 16 | Column in Super - Structure |
| 17 | Lintel |
| 18 | Roof Beam |
| 19 | Roof Slab |
| 20 | Chajja |
| 21 | Providing & fixing TMT Fe-500 reinforcement bars for RCC work of required diameter of approved quality with straightening, cutting, bending, binding welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing fan hooks, hoisting, lowering and laying including cost, conveyance and taxes of M.S. Rods or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the specification & direction ofEngineer-in-charge. |
| 22 | Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with OPC 53 grade cement finished smooth to outside surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. |
| 23 | Providing 16mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with OPC 53 grade cement finished smooth to inside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. |
| 24 | 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. |
| 25 | Supplying, fitting & fixing of Kota Tiles of minimum 16 mm thickAbove 0.10 Sqm on 20mm thick bed of cement mortar (1:4) (1 cement : 4 course sand) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge. |
| 26 | Providing and layingVitrifiedfloor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. |
| 27 | Providing and layingVitrifiedskirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. |
| 28 | Providing and fixing 20mm thick Granite stone flooring(sample of Granitestone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 29 | Providing and fixing seasoned sal wood work in frames at any locations including doors, windows,cupboard, clerestory and other framesfixing in position including cost of hinges, M.S. flat (30mm x 6mm) hold fasts lugs ordash fasteners of required dia and length as per drawing / specification, at all floors and all heights. |
| 30 | Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railing ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damagedwalls/ structures with cement concrete (1:2:4)with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircaseand parapet railingssquare bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.) |
| 31 | Providing & Applying priming one coat with water based Cementprimer of approved brand and manufacture onplastered surface including cost, conveyance, loading and unloading and taxes of all materials, cost of all labour, sundries, T & P, scaffolding etc. required for the work and complete in all respect as per specification and direction of Engineer-in-charge. |
| 32 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer - In- Charge at all elevations including all material & labour complete. |
| 33 | Painting to external surface of building with two coats of weather coat of approved shade and quality of approved design, after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance and taxes of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. |
| 34 | Providing & painting Two coats of Plastic Emusion paint with 1st quality oil bound washable distemper of approved brand and manufacturer to give an even shade as per the instruction of Engineer - In- Charge at all elevations including all material & labour complete. |
| 35 | Providing and painting two coats with synthetic enamel paint of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height over a coat of primer of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading, and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. |
| 36 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. |
| 37 | Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer\"s specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. |
| 38 | INTERNAL P.H. & SANITARY WORKS |
| 39 | GPH Works: Supplying allmaterials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal borewith clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer-in-charge. |
| 40 | Ground Floor- 20 mm CPVC SDR-11 pipes (Oriplast/Supreme) |
| 41 | 25 mm CPVC SDR-11 pipes (Oriplast/Supreme) |
| 42 | 32 mm PVC sch-80 pipes (Oriplast/Supreme) |
| 43 | 40 mm PVC sch-80 pipes (Oriplast/Supreme) |
| 44 | 50 mm PVC sch-80 pipes (Oriplast/Supreme) |
| 45 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. |
| 46 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer-in-charge. |
| 47 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the Engineer-in-charge. |
| 48 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer-in-charge. (a)Supplying all materials, labour, T&P and fixing standard sized two wayBib cock ofapproved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with Flange . |
| 49 | Supplying all materials, labour, T&P and fixing standard sizedBib cock ofapproved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.15mm dia. nominal bore Short body Bib Cock. |
| 50 | Supplying all materials, labour, T&P and fixing standard sized15mm dia angular Stop cock ofapproved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP angle stop cock with wall flange . |
| 51 | Supplying all materials, labour, T&P and fixing standard sized pillar cock ofapproved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock |
| 52 | Fixing of 25mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge.32mm dia brass or gun metal full way valve (shakti make) |
| 53 | Fixing of 32mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge.32mm dia brass or gun metal full way valve (shakti make) |
| 54 | Fixing of 40mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 ofof approved makeas per specification complete as per direction of Er-in-charge.40mm dia brass or gun metal full way valve(shakti make) |
| 55 | 15mm dia PVC connection pipe 450 mm long |
| 56 | 15mm dia CP Extention Nipple |
| 57 | Providing and fixingcircular type stainless steeljalli (grating) with hole for floor /nahani trap etc complete as per specification and direction of the Engineer in charge. |
| 58 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of theEngineer-In-Charge . 15mm dia CP Health Faucet of Jaquar 1.5mtr long, 8MM dia. |
| 59 | Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701--1996 including cutting holes through the tank and fixing mild steel ltubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting up to a height of 5 meters above ground level and placing the tank to the required position and providing 1st class K.B.Brick work in cement mortar (1:6) of 0.46mt. height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C.slab of size 1.60mt.x1.60mt. and 0.10mt. thick, R.C.C.beam of 0.25mt.x0.30mt. and 2.60mt. average length in cement concrete (1:2:4) using 12mm size h.g.chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of theEngineer-In-Charge. 2000 litre capacity water storage tanksin the roof of 1st floor. |
| 60 | Supplying all materials, labour, T&P and fitting and fixing PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer\"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer-In-Charge |
| 61 | 110mm diameter PVC SWR pipes(Oriplast type-B/Supreme) |
| 62 | 110mm PVCdoor Tee |
| 63 | 110mm PVC offset |
| 64 | 110mm PVCdoor bend |
| 65 | 110mm PVCplain shoe bend |
| 66 | 110mm PVCvent cowl |
| 67 | 110mm P-trap |
| 68 | 110mm PVCplain bend |
| 69 | Supplying all materials,labour T&P and cutting holels through existing brick or laterite masonry wall for taking H.C.I set pipes and fittings including making good the damages etc. all complete as per P.H.Specification and direction of theEngineer-In-Charge. |
| 70 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern ofapproved make with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main etc all complete as per the specification and direction of the Engineer-in-charge. (10 Liters capacity PVC cistern with 32mm dia flush bend.Hindware sleek fresh single flushStarwhite, Size 47.6 X 15.5 X 32.5 cm) |
| 71 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) of approved make duly embedded in cement concrete (1:4:8) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI \"p\" or \"s\" trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages etc all complete as per specification and direction of theEngineer-In-Charge. (Procelain 23\"\" IWC (Orissa Pan) |
| 72 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of approved make with integral \"p\" or \"s\" trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of theEngineer-In-Charge. EWC with \"Porcelain\" / S trap plain |
| 73 | Supplying all materials, labour T&P and fixing wash basins ofapproved makewith hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered \"Hot\" and \"Cold\" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of theEngineer-In-Charge. (Hindware ARIEL Wash Basin Size - 550mmx400x790mm) |
| 74 | Supplying all materials, labour T&P and fixing counter top Wash Basin Size - 550mmx430mm,with all fittings as per direction of the engineer-in -charge. |
| 75 | Supplying all materials, labour, T&P and fixing Flat back large pattern urinal of approved make the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls land making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.size- 380x580x350. |
| 76 | Supply and fixing all materials, labour, T & P and providing urinal partition with italian collection(pastel)-cm etc all complete as per direction of the Engineer-In-Charge. Make-Hindware. |
| 77 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge. (750mmx600mm size B.E.mirror) |
| 78 | Supplying all materials, labour, T&P and fixing standard size glass-shelf of approved make with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification anddirection of the Engineer-in-charge. Jaquar glass shelf 600mm long |
| 79 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail24\"of Hindware/Jaquar/Parryware complete withCP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer-In-Charge. 25mmx600mm long CP towel rail |
| 80 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap case ofHindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. CP soap holder |
| 81 | Providing and laying Matte Finish Vitrifiedfloor tiles 300x300 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction ofEngineer-In-Charge at all floors and all heights. |
| 82 | Providing and fixing 1st quality Ceramic glazed wall tilesconforming to IS : 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of NITCO, SOMANY, ASIAN, KAJARIAor equivalent approved make in all colours, shades except burgundy, bottle green, black of size 300x200 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction ofEngineer-In-Charge. In all floors and all heights. |
| 83 | Supplying fitting, fixing Fatory made single leaf rigid FRP sandwich composite Door/Window shutter (allternatly GRP) of 32 mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised isopathalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) mpregnate with orthopthalic polysterskin. The thickness of the skins shall not be less than 1.5 mm Expanded polystyone(EPS) structural foam panel of 29 mm thickness and a density of 20 kg/cu.mtr shall be used as core material. Wooded reinforcement made of seaoned sal wood block of cross section not less than 28mm x 32mm and also necessary sal wood reinfocements for fitting the metal fittings such as tower bolt, aldrop. hanles, etc. shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material. The material and process for manufacturing the door shutters shall be conform to RV- TIFAC composite design Center\"s standards and specifications and the door shutters tested in conforming to IS: 4020-1998. The finish door shutter will be plain colour as per specification and diection of Engineer-In-Charge. |
| 84 | Providing and fixing FRP Door frames Size (65mmx90mm)at any locations including doors, windows, cupboard, clerestory and other framesfixing in position including cost of hinges, M.S. flat (30mmx6mm) hold fasts lugs or dash fasteners of required dia and length as per drawing/specification, at all floors and all heights. |
| 85 | EXTERNAL P.H. & SANITARY WORK |
| 86 | Supplying all materials, labour, T & P and constructing Gully trap chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. 250mmx250mm with RCC cover |
| 87 | Supplying all materials, labour, T & P and constructing Inspection chamber of the following inside size with CC (1:3:6) mix using 40mm size h.g. metal on bed, Ist class Fly Ash brickwork in CM (1:6) , moulding and shaping the channel inside and benching with CC (1:2:4) using 12mm size h.g. chips, 12mm thick cement plastering (1:3) finished with punning to inside , cement flush pointing (1:3) to outside , R.C.C. cover slab in (1:2:4) using 12mm size h.g. chips with RCC man hole cover , earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering ,curing, conveyance of all materials to worksite , payment of royality , taxesetc. all complete as per aproved drawing , specification and direction of Engineer-in-charge. Inside size 760mm x760mm x450mm |
| 88 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class-3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer-in-charge. 110 mm dia U-PVC pipes Class-3 (0.60 mpa) |
| 89 | 160 mm dia U-PVC pipesClass-3 (0.60 mpa) |
| 90 | Supplying all materials, labour, T&P and constructing Man hole chamber of the following size withcement concrete (1:3:6) using 40 mm size HG metal on bed , !st class Fly Ash Brick work in CM (1:6) moulding and shaping the channel inside and benching with CC (1:2:4) mix using 12 mm size H.G chips,12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside ,RCC cover slab in (1:2:4) mix using 12 mm size H.G chips with RCC man hole cover , earth work in all kinds of soil and refilling the cavity around the camber including watering, curing, conveyance of all materials to worksitepaymentof royalty, taxes etc. all completed as per approved drawing, specification and direction of Engineer-in-charge. Inside size 900mmx800mmx450mm |
| 91 | Addl depth of 0.10m or part there of |
| 92 | Construction of 100 users septic tank. Size:- (8x2.6x2) mtr |
| 93 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of theEngineer-in-Charge. |
| 94 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15 cm in depth : consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 95 | Supplying offilling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of E.I.C. |
| 96 | Providing and laying plain cement concrete 1:3:6 (1 cement: 3 sand : 6 stoneaggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. |
| 97 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge (230X110X80) |
| 98 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:6) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 99 | Providing 16mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with OPC 53 grade cement finished smooth to inside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. |
| 100 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 101 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 102 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-250 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, includingcentering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
| 103 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 104 | Supplying all materials, labour, T&P and constructing soakway pit of the following size withbrick masonnary wallRCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer-In-Charge . RCC soakway pit 1.2m dia x 2.0m deep |
| 105 | BOREWELL : Construction of 1 No production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories |
| 106 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only. Drilling of 200mm dia bore |
| 107 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200mm dia P.V.C casing pipes |
| 108 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber \"O\" ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. 200mm dia PVC (sch-80) pipe |
| 109 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing. |
| 110 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge. By DTH Rig |
| 111 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make). |
| 112 | 1 H.P. Single phase/ three phase 3 stagehead renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm |
| 113 | DOL Control panel |
| 114 | 40mm dia steel short piece |
| 115 | Well cap |
| 116 | 50mm size CI bracket |
| 117 | 2.50sqmm flat cable |
| 118 | Steel rope with cover |
| 119 | Labour charges for lowering including transportation |
| 120 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge. 32mm HDPE pipes |
| 121 | INTERNAL ELECTRICAL WORK |
| 122 | INTERNAL WIRING |
| 123 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havels/ V-Guard / ABB-Trisha) (Make of modular box,cover,switch & socket-Legrand(/Panasonic-Vision/Myrios). Group C |
| 124 | Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/V-Guard)Average Length: 3mtr |
| 125 | Recessed wiring to ceiling fan point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havells/V-Guard)Group B |
| 126 | Recessed wiring to Twin control light pointwith 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havells/V-Guard)Group C |
| 127 | Supply & Fixing of 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on existingswitch board as per direction of Engineer-in-charge. It includes eletrical connecting wires. |
| 128 | Recessed wiringon looping for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.(Make of wire Finolex /Polycab/ Anchor / Havells/V-Guard)Group C |
| 129 | supply & Fixing of 2 nos 6 A socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge. |
| 130 | Supply & Fixing of 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 25 nos for Stage Light, 3Nos For Aquaguard. |
| 131 | Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/V-Guard)Group B |
| 132 | Call bell point with call bell. |
| 133 | Supply & Fixing 3 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge. |
| 134 | SUBMAIN. |
| 135 | Recessed wiring to submain in 4 x 16 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/V-Guard) |
| 136 | Recessed wiring to submain in 4 x 10 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex /Polycab/ Anchor / Havels/V-Guard) |
| 137 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/V-Guard) From UPS OP DB to CDB. |
| 138 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/V-Guard) |
| 139 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/V-Guard) |
| 140 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/V-Guard) (For Switch Board Looping) |
| 141 | DB : Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid tripposition for toggles for electrical fault conditions. |
| 142 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards For ACDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-63AFPMCB (10KA)Outgoings-16/20A SP MCB 10KA-12Nos.(Make- Schneider/Legrand/Hager) |
| 143 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards For LDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-40A4PMCB (10KA)Outgoings-6 A SP MCB 10KA- 12 Nos,(Make- Schneider/Legrand/Hager). |
| 144 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted12 way SPN Distribution Boards For COMM. DB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-32ADPMCB (10KA)Outgoings-10 A SP MCB 10KA- 10 Nos,(Make-L&T/ Schneider/Legrand/Hager). |
| 145 | EARTHING |
| 146 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required. |
| 147 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required. |
| 148 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required. |
| 149 | Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required. |
| 150 | Lightning Arrester. |
| 151 | Supply & fixing of lightning arrester of size 2.6\" length made of 0.5\"diameter copper rod, over which 5nos 5\" length pointed copper rods of 0.3\" diameter with suitable size of nuts and bolts. |
| 152 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required. |
| 153 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required. |
| 154 | FIXTURE : Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required . ( Make-JAQUAR/philips/wipro/Panasonic/Equivalant.) |
| 155 | Ceiling mounted indoortypebatten typeLED Luminaire with LED Lamp Similar to JAQUAR Cat No. LGLZPCX022XWor equivalent. |
| 156 | Ceiling mounted6W LED Round Recessed light Similar to JAQUAR Cat No. LNRP01R006XWor equivalent. |
| 157 | Ceiling/ Wall mounted typeBULK HEADLuminaire withSimilar to JAQUAR Cat No.LBLK02X010XW or equivalent. |
| 158 | Supply, Installation, testing and commissioning of 10W Mirror Light Similar to JAQUAR Cat no-LTBL01X010XC/Equivalent. |
| 159 | Supply &fixing of 15W LED SQUARE RECESSED Light Similar to JAQUAR Cat no-LNEP01S015XC with all or equvivalent with all accessories . |
| 160 | Supply, Installation, testing and commissioning of ENTRY EXIT LIGHT Double side LED SIMILAR TO BAJAJ CAT. NO-BESL 03 LED DSD WBB GREEN /Equivalent. |
| 161 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required. (Make-Usha/Bajaj/Cromption/Orient Summer) |
| 162 | Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required. |
| 163 | Ceiling mountedLED 12W Round SURFACE light Similar to JAQUAR Cat No. LNRO02R012SWor equivalent. |
| 164 | Ceiling mountedLED 18W SQUARE SURFACE light Similar to JAQUAR Cat No. LNRO02S018SWor equivalent. |
| 165 | Supply, Installation, testing and commissioning of WALL Light similar to Jaquar cat no-150.01.BGG / Equivalent. etcas required. |
| 166 | Supply &fixing of LED Indoor type Strip light 5mtr long roll similar to jaquar cat no-LSTP03X005XW and all accessories. |
| 167 | Supply &fixing of LED STEP LIGHT SIMILAR TO JAQUAR MODEL NO- 4100M.NGG/ Equivalent as required. |
| 168 | PANEL : Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp,C.T , Digital Voltmeter,Digital Ammeter and control fuse etc. complete. MAKE- Legrand / Schneider/ Hager /SIEMENS. |
| 169 | MAIN PANEL with 120A 4P MCCB 50KA -1 No as incomer,4Nos 63A 4P MCB 10KA &63 A 4P Change over switch-1Nos, 63 A 4P MCB 10KA -3Nos, 40A DP MCB 10KA-6Nos. (Make-Legrand / Schneider/ Hager /SIEMENS/ABB) |
| 170 | PUMP DB with 63A 4P MCB (10KA) -1 No as incomer ,32A 4P MCB 10KA-2Nos, 20A DP MCB 10KA-3 Nos as Outgoing with E.C Busbars . (Make-Legrand / Schneider/ Hager /SIEMENS/ABB) |
| 171 | CABLE & END TERMINATION |
| 172 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 50 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable) |
| 173 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of4 core 16 sq.mm Aluminium on surface as required.(Make-polycab/RR Kable/Rhino cable) |
| 174 | END TERMINATION : Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
| 175 | 3.5C x 50 sq.mm |
| 176 | 4C x 16 sq.mm |
| 177 | Perforated type cable tray :Supply and installation of Pregalvanised Perforated type cable trays without cover. The rate shall include bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc., including painting of cable trays. Thickness of sheet steel shall be 2 mm. Support sizes similar to ladder type trays |
| 178 | Size of Cable Tray :150 mm x 50 mm |
| 179 | SAFETY EQUIPMENTS |
| 180 | Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate. |
| 181 | Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate. |
| 182 | Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate . |
| 183 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 184 | Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room. |
| 185 | 63-KVA Silent D.G. SET |
| 186 | Supply & delivery of 63-KVA silent DG sets along with engine-alternator, Control panel containing 1 No 100A, 4P MCCB & required protections and metering arrangement (in tamper proof compartment with locking arrangement) with 5-A digital KWH meter & CTs for DG set, etc as required , acoustic enclosure, diesel tank, residential silencer and complete as required as per the technical specification and as per direction of Engineer-in-charge. |
| 187 | Installation, testing andcommissioning of 63-KVA silent DG sets along with engine-alternator, Control panel containing 1 No 100-A, 4P MCCB & required protections and metering arrangement (in tamper proof compartment with locking arrangement) with 5-A digital KWH meter & CTs for DG set, etc as required , acoustic enclosure, diesel tank, residential silencer and complete as required as per the technical specification and as per direction of Engineer-in-charge. |
| 188 | DG Set Foundation including barbared wire fencing / Roof shade as required. |
| 189 | Excavation |
| 190 | Cover slab |
| 191 | Reinforcement |
| 192 | Brick Footing |
| 193 | Sand filling |
| 194 | PCC (1:4:8) |
| 195 | TP Meter Box of63KVA DG set |
| 196 | 1 No 3 phase 4 wire 5amp CT operateddigital KWH meter in tamper proof enclosure with locking and sealing arrangement along with suitable bus bar arrangement,for mounting of C.T\"s & 100/5-A CTs, cable termination arrangement complete as required |