Inter-University Centre For Astronomy And Astrophysics-ICFAA has published Supply, Installation, Testing And Commissioning Of Hiwall Split Ac Units With All Inverter Compressor Consisting Of - ( 1 ) Condensing Unit With Reputed Make Hermetically Sealed Dc Twin / Swing Rotary Inverter Compressor, Air Cooled Condenser With Co. Submission Date for this Tender is 03-08-2022. Miscellaneous Fasteners Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply, Installation, Testing and commissioning of Hiwall Split AC Units with all inverter compressor consisting of - (1) Condensing unit with reputed make hermetically sealed DC Twin/Swing Rotary inverter compressor, air cooled condenser with copper Tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. (2) Indoor unit consisting of 3/4 row-cooling coilblower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. (3) The minimum acceptable value of Coefficient of Performance (COP) of the offered Split AC model shall be not less than 3.85 for 1.5 TR on 100% (5.0 Kw) and and 3.90 for 1.8/2 TR (6 Kw) Hiwall Split AC at rated Capacity with 35 deg. C outdoor and 19 deg. C wet bulb conditions. The COP confirmation should be done by the OEM on their authentic letter head. (4) The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. (5) Necessary charge of oil and refrigerant gas as required up to handling over & defects liability period of the system. (6) Interconnecting piping between evaporator and condensing units as per site requirement insulated suction line & liquid line for all the circuits of one machine. The suction lines shall be insulated with closed cell Nitrile rubber tube insulation. (7) The units shall be with individual cordless remote. (8)The units shall be suitable for operation on 220/240 Volts, 1 ph., 50 Hz, 3 wire A.C. supply. 1.8/2 TR capacity (6 Kw & above cooling capacity)- 5 Star, Inverter Hiwall Split AC Unit |
2 | Supply, Installation, Testing and commissioning of Hiwall Split AC Units with all inverter compressor consisting of - (1) Condensing unit with reputed make hermetically sealed DC Twin/Swing Rotary inverter compressor, air cooled condenser with copper Tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. (2) Indoor unit consisting of 3/4 row-cooling coilblower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. (3) The minimum acceptable value of Coefficient of Performance (COP) of the offered Split AC model shall be not less than 3.85 for 1.5 TR on 100% (5.0 Kw) and and 3.90 for 1.8/2 TR (6 Kw) Hiwall Split AC at rated Capacity with 35 deg. C outdoor and 19 deg. C wet bulb conditions. The COP confirmation should be done by the OEM on their authentic letter head. (4) The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. (5) Necessary charge of oil and refrigerant gas as required up to handling over & defects liability period of the system. (6) Interconnecting piping between evaporator and condensing units as per site requirement insulated suction line & liquid line for all the circuits of one machine. The suction lines shall be insulated with closed cell Nitrile rubber tube insulation. (7) The units shall be with individual cordless remote. (8)The units shall be suitable for operation on 220/240 Volts, 1 ph., 50 Hz, 3 wire A.C. supply.1.5 TR capacity (5 Kw cooling capacity)- 5 Star, Inverter Hiwall Split AC Unit |
3 | Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation 5/8" & 3/8" or 1/2" & 1/4" /Suitable for above machines |
4 | Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation Drain piping in hard CPVC with all fittings, supports and clamps upto 50 mm dia. including drilling hole in wall chipping wall etc to conceal and to route drain pipe. |
5 | Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation Set of Power & Control Cabling complete for all circuits of machine with insulation and conduiting complete with supporting arrangement etc. forHiwall Split AC. |
6 | Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation MS structural work and special supporting structure for condensing units, Powder Coated |
7 | Refrigerant Copper piping 18/ 20 Gauge With 19 mm Thick O-class insulation Core cutting in wall/slab for AC piping (pleaser refer tender document for details). |