Indian Oil Corporation Limited-IOCL has published Oso Engg Design Supply Installation Testing And Commissioning ( Excluding Software Integration ) Of Tank Farm Management System For Newly Installed 5 Ug Ethanol Tanks Along With 5 No. Pressure Transmitters Etc At Jharsuguda Top, Odisha => Limited. Submission Date for this Tender is 16-08-2022. Natural Fuels Tenders in jharsuguda Odisha. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-Aug-2022 | Date Corrigendum-I | Date | 13-08-2022 |
2 | 12-Aug-2022 | Date Corrigendum-II | Date | 16-08-2022 |
Sl. No. | Item Description |
1 | TAS WORKS FOR U/G ETHANOL TANKS & PUMPS |
2 | AUTOMATION SUPPLY |
3 | Tank Farm Management System |
4 | Supply of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better, in built digital display, along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) |
5 | For U/G horizontal product tanks (Ethanol - 5 nos.) |
6 | Supply of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document |
7 | For U/G horizontal product tanks (minimum Two No.) |
8 | Supply of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) |
9 | For U/G horizontal product tanks (minimum One No.) |
10 | Supply of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) |
11 | For U/G horizontal product tanks (minimum One No.) |
12 | Supply of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete as per specification and tender document |
13 | For U/G horizontal product tanks (minimum One No.) |
14 | Supply of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system as per specification and tender document |
15 | For Primary Radar Gauges installed on under ground Ethanol Tank (5 Nos.) |
16 | Supply of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, isolation valve, Aluminium canopy/ sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated else where in tender). Note:1. Pressure transmitter at suction shall have range from -1 Kg/cm2. 2. Underground tank shall have PT in Pump discharge end only. |
17 | Underground tank Discharge Line |
18 | ESD Push Button Station |
19 | Supply of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document |
20 | Cabling,JB, Earthing: Note: Supply of cables shall be along with certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners |
21 | Supply of Armoured Copper Power cable as per tender specifications. |
22 | 3C x 2.5 sqmm (FS) |
23 | 24C x 2.5 sqmm (FRLS) |
24 | Supply ofArmoured Copper Control cable as per tender specifications. |
25 | 2C x 1.5 sqmm (FS) |
26 | 16 C x 1.5 sqmm (FRLS) |
27 | 32 C x 1.5 sqmm (FRLS) |
28 | Supply of Armoured Copper Signal cable as per tender specifications. |
29 | 1P x 1.5 sqmm (FS) |
30 | 2P x 1.5 sqmm (FRLS) |
31 | 2P x 1.5 sqmm (FS) |
32 | 8P x 1.5 sqmm (FRLS) |
33 | 12P x 1.5 sqmm (FRLS) |
34 | Supply of 1C x 6 Sq. mm Flexible copper insulated green wirefor earthinginstruments and junction boxes etc complete as per specification and tender document |
35 | Supply of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excessentries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners.Complete as perspecification / tender documents. |
36 | 24 way JB |
37 | 18 way JB |
38 | 12 way JB |
39 | 8 Way JB |
40 | 6 way JB |
41 | 4 way JB |
42 | Supply of Digital Input Module-16 Channels |
43 | Supply of Digital Output Module-32 Channels |
44 | Analog Output Module-16 Channel |
45 | AUTOMATION SERVICE |
46 | Tank Farm Management System |
47 | Installation, integration, testing and commissioning of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better, in built digital display, along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) |
48 | For U/G horizontal product tanks |
49 | Installation, integration, testing and commissioning of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document |
50 | For U/G horizontal product tanks (minimum Two No.) |
51 | Installation, integration, testing and commissioning of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) |
52 | For U/G horizontal product tanks (minimum One No.) |
53 | Installation, integration, testing and commissioning of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) |
54 | For U/G horizontal product tanks |
55 | Installation, integration, testing and commissioning of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete as per specification and tender document |
56 | For U/G horizontal product tanks (minimum One No.) |
57 | Installation, integration, testing and commissioning of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system as per specification and tender document |
58 | For Primary Radar Gauges installed on under ground Ethanol Tank (5 Nos.) |
59 | Installation, integration, testing and commissioning of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, isolation valve, Aluminium canopy/ sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated else where in tender). |
60 | Underground tank Discharge Line |
61 | ESD Push Button Station |
62 | Installation, Testing and Commissioningof Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document |
63 | Cabling,JB, Earthing: Laying, glanding, ferruling, termination of cables shall be along withcertified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners |
64 | Laying, glanding, ferruling, termination of Armoured Copper Power cable as per tender specifications. |
65 | 3C x 2.5 sqmm (FS) |
66 | 24C x 2.5 sqmm (FRLS) |
67 | Laying, glanding, ferruling, termination ofArmoured Copper Control cable as per tender specifications. |
68 | 2C x 1.5 sqmm(FS) |
69 | 16C x 1.5 sqmm (FRLS) |
70 | 32C x 1.5 sqmm (FRLS) |
71 | Laying, glanding, ferruling, termination of Armoured Copper Signal cable as per tender specifications. |
72 | 1P x 1.5 sqmm (FS) |
73 | 2P x 1.5 sqmm (FRLS) |
74 | 2P x 1.5 sqmm (FS) |
75 | 8P x 1.5 sqmm (FRLS) |
76 | 12P x 1.5 sqmm (FRLS) |
77 | Laying, glanding, ferruling, termination of 1C x 6 Sq. mm FRLS Flexible copper insulated green wirefor earthinginstruments and junction boxes etc complete as per specification and tender document |
78 | Installation of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excessentries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners.Complete as perspecification / tender documents. |
79 | 24 way JB |
80 | 18 way JB |
81 | 12 way JB |
82 | 8 way JB |
83 | 6 way JB |
84 | 4 way JB |
85 | Design, Supply, Installation, Testing & commissioning of MOV DB as approved by EIC. The job includes bus-bar modifications if any at site. Installation of panel shall be with supply of all ancillary materials all complete as directed by EIC. The MOV DB shall have minimum 12 nos. feeders for providing power supply to 10 nos. 6" MOVs. & 2 nos. spare and ancillary items as directed by EIC. |
86 | MISCELLANEOUS WORKS FOR CABLE LAYING |
87 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately. |
88 | i) All kinds of Soil |
89 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. |
90 | i) Local Fine Sand within grading zone IV |
91 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
92 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
93 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
94 | viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 20mm) |
95 | Centering and shuttering including strutting, propping etc. and removal of form for : |
96 | i) Foundations,footings,bases of columns, etc. for mass concrete |
97 | Clearing grass and removal of the rubbish outside site premises and at an unobjectionable place. |
98 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
99 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
100 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
101 | ii) RCC 1 Cement :2 Coarse Sand: 4 Graded Stone Aggregate 20mm |
102 | Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position & applying a priming coat of approved steel primer etc. as required. |
103 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength |
104 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH |
105 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
106 | ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) |
107 | DemolishingPCC/RCC manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge. |
108 | i) 1:3:6 or richer mix (i/c equivalent design mix) |
109 | Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside premises at an unobjectionable place as / direction of Engg-in-charge |
110 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
111 | Finishing walls with water proofing cement paint of required shade with Two or more coats applied @ 3.84 kg/10 sqm: |
112 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
113 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty |
114 | iv) 300 mm dia. R.C.C. pipe |
115 | CABLE BRICK DUCT Providing & constructing underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils |
116 | i) 450 mm (24 Bricks & 0.0494 cum per Mtr) |
117 | ii) 225 mm (16 Bricks & 0.0195 cum per Mtr) |
118 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4coarse sand : 8 gradedstone aggregate 40mmnominalsize) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
119 | iii) Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With common burnt clay bricks of class designation 7.5 |
120 | Supplying of following sizes of perforated GI cable trays (2.0 mm Thick and 25mm edge height) with Cable Tray Cover (1.6 mm Thick and 10 mm edge height) including horizontal and vertical bends, reducers, tees, cross members and other accessories as required. MS Structures angles, suspenders will paid separately |
121 | 300mm x 25mm x 2mm |
122 | 150mm x 25mm x 2mm |
123 | 100mm x 25mm x 2mm |
124 | 50mm x 25mm x 2mm |
125 | Installation of following sizes of perforated GI cable trays (2.0 mm Thick and 25mm edge height) with Cable Tray Cover (1.6 mm Thick and 10 mm edge height) including horizontal and vertical bends, reducers, tees, cross members and other accessories as required. MS Structures angles, suspenders will paid separately |
126 | 300mm x 25mm x 2mm |
127 | 150mm x 25mm x 2mm |
128 | 100mm x 25mm x 2mm |
129 | 50mm x 25mm x 2mm |
130 | Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long |
131 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
132 | ii) 32 x 6 mm G.I.strip |