Airports Authority Of India has published Provision Of Surge Suppression And Fire Suppression Systems Etc. For Electrical And Cns Installation At Srinagar Airport.. Submission Date for this Tender is 10-08-2022. Fire Suppression System Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 05-Aug-2022 | CORRIGENDUM1 | Technical Bid | 10-08-2022 |
Sl. No. | Item Description |
1 | Supply, Installation, Testing & Commissioning of Aerosol based Fire Suppression System Aerosol generator having aerosol mass of 2500gm shall be electrically actuated by means of Fire Alarm cum Release Panel. The housing shall be constructed of stainless steel shell.Housing shall be sealed with a non-permeable membrane. Units shall have passed salt spray corrosion testing per UL Standard 2127 as part of their listing. Aerosol generated shall be potassium based. Agent shall have no ozone depletion potential and no global warming potential. Agent shall be listed by the US EPA under the SNAP program. Aerosol generators shall be listed by Underwriter’s Laboratories (UL) to UL Subject 2775 covering Fixed Condensed Aerosol Systems per NFPA 2010. UL approved design density of the aerosol should be less than 100g/cu.mtr for Class A, B & C fires as per NFPA. The Aerosol generator should have self life of15 years. Aerosol generator shall be supplied with Stainless steel Bracket & Gland. |
2 | Supply, Installation, Testing & Commissioning of Aerosol based Fire Suppression System Aerosol generator having aerosol mass of 1500gm shall be electrically actuated by means of Fire Alarm cum Release Panel. The housing shall be constructed of stainless steel shell.Housing shall be sealed with a non-permeable membrane. Units shall have passed salt spray corrosion testing per UL Standard 2127 as part of their listing. Aerosol generated shall be potassium based. Agent shall have no ozone depletion potential and no global warming potential. Agent shall be listed by the US EPA under the SNAP program. Aerosol generators shall be listed by Underwriter’s Laboratories (UL) to UL Subject 2775 covering Fixed Condensed Aerosol Systems per NFPA 2010. UL approved design density of the aerosol should be less than 100g/cu.mtr for Class A, B & C fires as per NFPA. The Aerosol generator should have self life of 15 years. Aerosol generator shall be supplied with Stainless steel Bracket & Gland |
3 | Supply, Installation, Testing & Commissioning of Aerosol based Fire Suppression System Aerosol generator having aerosol mass of 1000gm shall be electrically actuated by means of Fire Alarm cum Release Panel. The housing shall be constructed of stainless steel shell.Housing shall be sealed with a non-permeable membrane. Units shall have passed salt spray corrosion testing per UL Standard 2127 as part of their listing. Aerosol generated shall be potassium based. Agent shall have no ozone depletion potential and no global warming potential. Agent shall be listed by the US EPA under the SNAP program. Aerosol generators shall be listed by Underwriter’s Laboratories (UL) to UL Subject 2775 covering Fixed Condensed Aerosol Systems per NFPA 2010. UL approved design density of the aerosol should be less than 100g/cu.mtr for Class A, B & C fires as per NFPA. The Aerosol generator should have self life of 15 years. Aerosol generator shall be supplied with Stainless steel Bracket & Gland. |
4 | Supply, Installation, Testing & Commissioning of UL/EN Listed Fire Detection Cum Release System with cross zoning of UL listed heat & smoke detectors, UL listed hooter cum strobe, UL listed abort & release button with SMPS & Battery complete as required |
5 | Supply, Installation, Testing & Commissioning of 2 Core 1.5 sq. mm. FRLS type Armored cable complete as required. |
6 | Supply, Installation, testing and commissioning of Digital Grounding Device 240 kA 3 phase 4 wire Portable type with built in Low Impedance equipment Grounding & bonding system. Provides 100% protection against Lightning Surges, static charge, Noises, ESD, EPR and eliminates abnormal electrical distribances which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V having a digital 6 digit lightening surge counter, self health visual status indicator and in a Pre-wired pulverulent body painted metal enclosure to be connected in parallel to the power supply circuit, Conforming to IEC , CE Marked, NABL/ ULlistedcomplete as required. |
7 | Supply, Installation, Testing & Commissioning Cylinderless Clean Agent based (Zero global warming potential) Fire Suppression systems, suitable for extinguishing, electrical enclosed panel, fire by automatically triggering the thermo-activated micro capsules of aerosol forming solid compound (minimum 100gm aerosol for 1 cum panel space) or equivalent compound with cord minimum 3.5 Mtr for 1 cum panel space activated at 120-175 Degree C temperature ( as per requirement of compartment of the panel).in each compartment of the panel confoming to relevant NFPA 2010,UL approved .Agent shall be listed by the US EPA under the SNAP program. The system has to be maintenance free and without any pressurized cylinder,tube, pressure gauge as required. |