| 1 | EARTH WORK INEXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | EARTHFILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 3 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) |
| 4 | Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge. |
| 5 | Providing P.C.C. M-150 with nominal mix of (1:2:4) in steps and plinth..do..do..E/I. |
| 6 | Providing and laying R.C.C. M-20 with nominal mix of (1:1.5:3) in FOUNDATIONand plinthwithapproved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of centring ,shuttering and reinforcement) taxes and royalty all complete as per building specification and direction of E/I. |
| 7 | Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in columns, Tie beam with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3screening, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of centring ,shuttering and reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.UP TO PLINTH |
| 8 | Providing designation 75B brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I. |
| 9 | Providing designation 75B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I. |
| 10 | Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in Beam,suspended floors having slope up to 15,landing,balconies,shelves, chhajjas,lintel, bands,plain window sills, staircase with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3screening , mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of centring.shuttering, reinforcement ) taxes and royalty all complete as per building specification and direction of Engineer Incharge. |
| 11 | Providing 12 mm Thk. cement plaster(1:6) with clean course sand of FM-1.5including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all completeas per building specification and direction of E/I. |
| 12 | Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all completeas per building specification and direction of E/I. |
| 13 | Providing Two coats ofsnowcem of approved shade & make over a coat of cement primer on new surface including preparing the plaster surface smooth with sand paper scaffolding, curing and taxes all completeas per building specification & direction of E/I. Outer area |
| 14 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. Inner portion area |
| 15 | Providing & fixing FAN HOOK of 16 mm dia M.S. bar, 1 M long bent to required size and shape, placed in position and fluid in the R.C.C. slab-beam at the time of casting all complete as per building specification and direction of E/I. (where material is not supplied by deptt.) |
| 16 | Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I. |
| 17 | Supplying, fitting & fixing 20 guage G.C.I sheet gate as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I. |
| 18 | Providing two coats of SYNTHETIC ENAMEL PAINT over a coat of primer of approved shade and make over STEEL SURFACE including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 19 | Providing two coats of SYNTHETIC ENAMEL PAINT of approved shade and make over new WOODEN surface including cleaning the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification dirction of E/I. |
| 20 | Supplying, fitting & fixing 30 mm th. Solid core type non-decorative single leaf FLUSH DOOR SHUTTERS in doors and windows with block board core blended with high quality phenol formal dehydes synthetic resinboth side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts , handle,cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I |
| 21 | P/S pressed door framrs of 1.25 mm thick commercial mild steel do..do..with steel but hinges and a coat of steel primer all complete job. |
| 22 | Supplying, fitting & fixing 30 mm thick solid core type decorative single leaf flush door shutter with one side teak decorative and another side commercial veneered with Aluminium fittings such as hinges, tower bolts , handle,cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I |
| 23 | Providing tor steel reinforcement of 8mm,10 mm,12mm.16mm dia bars as per approved design and drawing excluding carriage of M.S bars to work .. do...do.. E/I.(i) 8mm&10mm dia 40% |
| 24 | (ii) 12mm & 16mm 60% |
| 25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 26 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 27 | Centring and shuttering including strutting ,proping etc and removal of form … (i) foundation, footing etc |
| 28 | suspended floors, roofs , landings,balconies and access platform |
| 29 | Lintels,beams,plinth beam,girder and cantilever |
| 30 | columns,pillars,piers,abutment,posts,and struts |
| 31 | Providing and laying Double Charge VITRIFIED FLOOR TILES in different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.08% and confirming to IS : 15622/ISO 13006 of approved make in all colors and shades laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand) including grouting the joints withcement and matching pigments etc. complete. SIZE - 300X300 mm |
| 32 | Providing 12mmcement plaster(1:3) with clean course sand of F.M 1.5 with floatingcoat of neat cement in skirting including rounding of junctions with floor, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 33 | Providing and laying wall tiles 15x15 cm all complete as per drawing specification and direction of E/I. |
| 34 | CARRAIGE OF MATERIALSA)SAND , LEAD - 5 km |
| 35 | B) STONE CHIPS LEAD-68 km |
| 36 | C) Bricks lead 8 km |
| 37 | Const. septic tank and soak pit :- EARTH WORK INEXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. |
| 38 | Extra for earthwork in hard soil as per specification and direction of E/I. QTY. same vide item no 1 |
| 39 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) |
| 40 | Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge. |
| 41 | Providing P.C.C. M-150 with nominal mix of (1:2:4) in retaining walls ,return wall..do..do..E/I. |
| 42 | Providing designation 75B brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I. |
| 43 | Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in Beam,suspended floors having slope up to 15,landing,balconies,shelves,chhajjas,lintel,bands,plain window sills,staircase with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3screening , mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of centring.shuttering, reinforcement ) taxes and royalty all complete as per building specification and direction of Engineer Incharge. |
| 44 | Providing tor steel reinforcement of 8mm, dia bars as per approved design and drawing excluding carriage of M.S bars to work .. do...do.. E/I. |
| 45 | Providing 12 mm Thk. cement plaster(1:4) with punning including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all completeas per building specification and direction of E/I. |
| 46 | Construction of soak pit 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100mm dia and 1.20 m long complete as per standard design. |
| 47 | CARRAIGE OF MATERIALSA)SAND , LEAD - 5 km |
| 48 | B) STONE CHIPS LEAD-68 km |
| 49 | C) Bricks lead 8 km |
| 50 | ELECTRICALANNEXURE-(A )WIRING.Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FRPVC insulated copper conductor single corecable in surface/recessed PVC conduit, with piano type switch , phenolic laminated sheet, suitable MS box and earthing the point with 1.5sq mm FR PVC insulated copper conductor single core cable etc as required. |
| 51 | Wiring for light/power plugwith 2x 4 sq.mm FR PVC insulated, copper conductor ,single core cable in and surface/recessed PVC conduitalong with 1 No. 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as requried . |
| 52 | Wiring for circuit / sub main wiring alongwith earth wire with the following sizes ofPVC insulated, copper conductor , single core cable in surface/ recessed PVC coduit as required.2X1.5 sq mm +1 x 1.5sq mm earth wire. |
| 53 | S/F Brass/Angle Holder including connection etc as required. |
| 54 | S/F 3 pin 5 Amp ceiling rose on the existing junction box wooden block including connection etc as req. |
| 55 | S/F TPN RCCB :-Supplying and fixing of following rating.double pole,single pole and neutral,240 volts,residual current circuit breaker having a sensitivity current 30 millli amperes in the existing MCB DB complete with connection .. do..do…. 40 Amp |
| 56 | 18/20 watt CFL Lamp |
| 57 | Ceiling fan 48\" (1200 mm ) |
| 58 | I.T.C of Ceiling fan including wiring the down rods of stsndard length up to 30 cmwith 1.5sq mm FR PVC insulated copper conductor single core cable etc as required. |
| 59 | S/F Sheet metal on/off load changeover :-Providing and fixing following capacity 2 pole/ 4 pole changeover switches with side handle operation in sheet enclosure in existing metal board including drilling holes in metal board making connection ,earthing the body etc as required.63 amps,4 pole |
| 60 | S/F Moduler type electronic fan regulator |
| 61 | 12\" (300 mm ) metal exhaust fan |
| 62 | WATER SUPPLY AND SANITARY WORK :- Polythine waterstorage tank of ISI mark sintex/sinter/Himgiri/Gangotri etc with cover and locking sistern. |
| 63 | Providing and fixing on wall face unplasticised rigid PVCrain water pipe confirming IS:13592 type A including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion…do…doall complete job.(i) single socketed pipes 110 mm |
| 64 | P/S/F special type of C.P bath room fitting for V.I.P building (JAL,JAQUAR,MARK OR Equivalent)Bib cock |
| 65 | Bib cock long thread |
| 66 | Angular stop cock |
| 67 | Towel rail 24\" |
| 68 | Towel rail |
| 69 | soap dish |
| 70 | Providing and fixing Mirror of 6mm thick plain glass 600mm x 450mm with all complete job. |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL)Concealed work including cutting chases and making good the wall etc. 15mm nominal outer dia pipes |
| 72 | 25mm dia |
| 73 | 32 mm dia. |
| 74 | Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required:kitchen sink without drain board 610x510mm bowel depth 200mm |
| 75 | Providing and fixing Wash basin with C.I/M.S brackets, 15mm C.P. pillar cock 32mm C.P brass waste of cutting and making good the wtherever require. |
| 76 | Providing and fixing white vitreous , parry Hindustan or any other with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.(c) 580 mm long with 12.50 ltr.L/L PVC cistern |
| 77 | Add 12% for G.S.T. |
| 78 | Labour Cess |