}

Construction Divisional Workshop For Pwd Division At Naharlagun In Papumpare District., naharlagun-Arunachal Pradesh

Public Works Department-PWD has published Construction Divisional Workshop For Pwd Division At Naharlagun In Papumpare District.. Submission Date for this Tender is 25-07-2022. Building Work Tenders in naharlagun Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33160946
Construction Divisional Workshop For Pwd Division At Naharlagun In Papumpare District.
Open Tender
Indian
Arunachal Pradesh
naharlagun
25-07-2022

Tender Details

Construction Divisional Workshop For Pwd Division At Naharlagun In Papumpare District.

Key Value

Document Fees
Refer document
EMD
INR 594074.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: C/o Divisional Workshop for PWD Division at Naharlagun in papumpare district.
Sl. No. Item Description
1SH : I : MAIN BUILDING
2Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
3Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
4Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
5Providing and laying in foundations and plinth cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
6Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
7Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
8Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
9Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1:3(1cement:3finesand) of thickness not exceeding 6mmto give a smooth and even surface but excluding cost of centring and shuttering andreinforcement with M20 (1cement:1.5coarsesand:3stoneaggregate20mm nominal size).
10Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cementortar1:3 (1cement:3finesand) of thickness notexceeding 6mmtogivea smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcementwithM20(1cement:1.5coarsesand:3stoneaggregate20mm nominal size).
11Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers bands and facias up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding the 6m to give a smooth and even surface but excluding the cost of centering, shuttering and reinforcement with M20 (1 cement : 1.5 fine sand : 3 stone aggregate 12.5 mm nominal size).
12Centring and shuttering including strutting, propping etc and removal of form work for :
13a)Foundation, footings, bases of columns etc. and mass concrete.
14c)Columns, pillars, posts and struts etc.
15d)Lintels, beams, girders, bressumers and cantilevers etc.
16e) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
17f) Stairs (excluding landings) except spiral stair cases.
18g) Horizontal fins individually or forming box louvers bands and facias
19Reinforcement of RCC work including bending, binding and placing in position complete.a)Cold twisted bars.
20Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
21Half brick masonry in cement mortar 1:4 (1 cement :4 coarse sand) in foundation and plinth.
22Providing hoop iron 25 mm x 1.60 mm or equivalent reinforcement in brick masonry at every fourth course, embedded in cement mortar.
23Providing and fixing T-iron frames for doors, windows and ventilators of MS Tee sections joints mitred and welded with 15 x 3 mm legs, 10 cm long embedded in cement concrete block 15 cm x 10 cm x 10 cm size of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or bolt and nuts as required, including fixing of necessary butt hinges and screws and applying a priming coat of approved primer.
24Providing and fixing in position collapsible steel shutters with vertical channels 20 mm x 10 mm x 2 mm and braced with flat iron diagonals 20 mm x 5 mm size with top and bottom rails of T iron 40 mm x 40 mm x 6 mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
25Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
26Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete
27c) Size of Tile 1000x1000 mm
28Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12mm thick bed of cement mortar1:3 (1cement:3coarsesand), including grouting the joint with white cement & matching pigments etc. complete
29c) Size of Tile 1000x1000 mm
30Providing and laying Ceramic Glazed tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12mm thick bed of cement mortar1:3 (1cement:3coarsesand), including grouting the joint with white cement & matching pigments etc. complete -for bath rooms
31Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
32Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
33Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. A) Granite work
34Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : Light shade pigment using white cement
3512 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
3615 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.
376 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall.
38Applying one coat of cement primer of approved brand and manufacture on wall surface.
39Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
40Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
41Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
42Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood complete.
43Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
44Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
45Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
46Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand). c)150 mm diameter pipe
47Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. c)150 mm diameter pipe
48Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
49Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.
50Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodized aluminum butt hinges with necessary screws.
51Providing and fixing flush door shutters, non-decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.a) 40 mm thick including anodised aluminium butt hinges with necessary screws
52Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.
53a)Ornamental Grill.
54Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.
55a)250 x 10 mm
56Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
57a)100 mm
58Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. a) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).
59Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)
60Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
61Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
62Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
63Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
64SH:- Sanitary and Water Supply
65Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.
66Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.
67a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality.
68Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.
69a) 100 mm dia
70Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.
71Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete.
72Providing and fixing 600 x 120x5mm glass shelf with edges roundedoff supported on anodised aluminium angle frame with C.P. brassbrackets and guard rail complete fixed with 40mm long screws, awlplugs etc . complete brass screws and washers.
73Providing and fixing CP brasstowel rail 600x20 mm size complete with two CP brass brackets fixed to woodencleats with CP brass screws .
74Providing and fixing toilet paper holder:
75C.P. brass
76Providing and fixing MS holder-bat clamps of approved design to Sand cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) including cost of cutting holes and making good the walls etc.
77For 100 mm dia pipe
78Providing and fixing sand cast iron heel rest sanitary bend.
79100 mm
80Providing and fixing ball valve (brass) of approved quality complete
81A) High pressure with copper floats
82a) 20 mm nominal bore
83G I Pipes and Fittings
84Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
85Concealed work, including cutting chases and making good the walls etc.
8615 mm dia.nominal bore
8720 mm dia.nominal bore
88Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
8925 mm dia.nominal bore
9032 mm dia.nominal bore
9150 mm dia.nominal bore
92100 mm dia.nominal bore
93Providing and fixing brass full way valve with wheel of approved quality.
9432 mmnominal bore
95Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
96Providing and fixing brass bib cock of approved quality.
9715 mm Nominal bore
98Providing and fixing brass stop cock of approved quality.
9915 mm Nominal bore
100Providing and fixing C.P brass long body bib cock of approvedquality conforming to IS standards and weighing not less than690 gmsa) 15 mm nominal bore
101Providing and fixingHealth faucet
102Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size), including finishing completeso as to make it leak proof.
103Sewerage
104Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
105Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
106Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : 19.7.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
107Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
108100 mm dia.nominal bore
109150 mm dia.nominal bore
110SH:- Septic Tank
111Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
112a) OrdinarySoil
113Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:
114Reinforced work in foundation footing, bases of columns, etc. and Mass concrete excluding cost of centering andshuttering, finishing and reinforcementin M20 1:1.5:3 (1 cement :1.5 coarse Sand :3 Stone Aggregate 20 mm nominal size)
115Reinforced cement concrete inwall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in :
116b)M201 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
117Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).in M20 1:1.5:3 (1 cement :1.5 coarse Sand :3 Stone Aggregate 20 mm nominal size)
118Centring and shuttering including strutting, propping etc and removal of form work for :
119a) Foundation, footings, bases of columns etc. and mass concrete.
120b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
121c) Suspended Floors
122Reinforcement of RCC work including bending, binding and placing in position complete.
123a. Cold twisted Bars
124Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
12512 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
126Neat cement punning.
127Providing laying and jointing glazed stone ware pipe grade "A" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
128a) 100 mm dia SW pipes
129b) 150 mm dia SW pipes
130Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.
131a) 100 mm dia SW pipes
132b) 150 mm dia SW pipes
133Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
134Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.
135Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
136CHAPTER-1 - W I R I N G
137Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
138Group A
139Group B
140Group C
141Wiringfortwincontrollightpointwith1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessedmediumclassPVCconduit,2waymodularswitch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mmFRLSPVCinsulatedcopperconductorsinglecorecable etc. as required.
142Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium classPVC conduit alongwith1No.4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
143Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas required.
1442 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1452 X 4 sq. mm + 1 X 4 sq. mm earth wire
1461.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
147Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
1482 Pair
149Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
150Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
15125 mm
152Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
153Telephone socket outlet
154TV antenna socket outlet
155Bell push
156Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
157Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
158Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1591 or 2 Module (75mmX75mm)
160Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
161Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
162Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
163Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connectionsetc. as required.
164Supplyingandfixingcallbell/buzzersuitableforsinglephase,230 V, complete as required.
165Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
166Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
167Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
168Upto 450 mm sweep
169Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
170Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1711 run of cable
172Supplying and fixing suitable size GI box with modular plate coverinfrontonsurfaceorinrecess,includingprovidngand fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
173Supplying&fixingsuitablesizeGIboxwihmodularplateand coverinfrontonsurfaceorinrecessincludingprovidingand fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
174Supplying and fixing PVC batten/ angle holder including connections etc. as required.
175Supplyingandfixingfollowingway,horizontaltypethreepole andneutral,sheetsteel,MCBdistributionboard,415V,on surface/recess,completewithtinnedcopperbusbar,neutralsurface/recess,completewithtinnedcopperbusbar,neutral includingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator)
1768 way (4 + 24), Double door
177Supplyingandfixing5Ato32A rating, 240/415V, 10kA,"C" curve,miniaturecircuitbreakersuitableforinductiveloadof followingpolesintheexistingMCB DBcompletewith connections, testing and commissioning etc. as required.
178Single pole
179Supplyingandfixingsinglepoleblankingplateintheexisting MCB DB complete etc. as required.
180Supplying and fixing following rating, double pole, (single phase andneutral),240V,residualcurrentcircuitbreaker(RCCB),havingasensitivitycurrent30mAintheexistingMCBDBcompletewithconnections,testingandcommissioningetc.as required.
18140 A
182Providing and fixing M.V. danger notice plate of 200 mm X 150 mm,madeofmildsteel,atleast2mmthick,andvitreous enameled white on both sides, and with inscription in single red colour on front side as required.
183Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc.as required.
184For 8 way, Double door TPN MCB DB
185Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
186Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipefromearthelectrodeincludingconnectionwithG.I.nut, bolt, spring, washer excavation and re-filling etc. as required.
187Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
188Laying ofone numberPVC insulated and PVC sheathed/ XLPE powercableof1.1KVgradeoffollowingsizeintheexisting RCC/ HUME/ METAL pipe as required.
189Upto 35 sq. mm
190Supplying and making end termination with brass compression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1913½ X 25 sq. mm (28mm)
192Supply of below mentioned Items-
1938 Watt Round LED Natural Light
1945 Watt Mirror Light
1951200 MM Ceiling Fan
196225mm Exaust fan
197Data Socket(RJ-45 CAT6) (Legrand Myrius)
198Make:
199Light- Philips
200Fan -Havells
201Supply of LTCABLES ( Non DSR Items)
202Supply offollowing 1100 voltgradeXLPE insulated PVC inner sheathed and FR PVC outer sheathed Aluminium conductor armoured LT cables .(Make: Cable- Polycab, RR Kabel, Havells )
2033.1/2 core 25 sq. mm
204Supply, erection, testing and commissioning of external swaged steel tubular pole with following specifications & items :
2059.0 Mtrs. high swaged steel tubular pole (Single arm of suitable length each around 1.5 Metre), the construction of the pole shall be as per IS 410 SP-33 with base plate 450mmX450mmX6mmcomplete as per requirement with two coats of spray paints (shade as approved)
206i)1X150 watts street light fixture with 150wattshigh pressure sodiumvapour (HPSV) lamp complete with control gear, acrylic cover cover etc. and its wiring with 2X4 sq.mm. PVC insulated, FRLS copper conductor and 1,5 sqmm PVC insulated, FRLS copper earth wire from control box complete as required - 1 No. (PhilipsSRP051/SON150W or approved equivalent)
207ii)Suitable size 32 A DP MS Control box with 2 no. incoming and outgoing terminals and 2 nos. tap-out terminal with 6A DP MCB complete as required - 1 Set
208iii) Suitable number(s) 40mm dia Class-B GI Pipe(s) from above control box to upto 0.5 metre below ground level for power cable entry
209iv)Providing foundation including excavation, shuttering, alingment of poles, casting etc. including lean concrete at the bottom as per CPWD/ BIS specifications.
210v) The above installations shall be completed as CPWD specifications and as required
211vi)Steet Tubular Poles(9M) as mention above
212Supply, installation, testing and commissioning of external post top lantern with following accessories and complete as required :
213i) 4m high (3.3m above ground) 50mm dia GI pole as approved, adopting socket at top for fixture mentioned below, base plate 300 x 300 x 6mm and provision for mounting junction box etc. - 1 set.
214ii) Supply, installation, testing and commissioning of Post top lantern with 70W HPSV lamp (Philips SPC 106/70(I) HPF or equivalent) and its wiring with 2 x 2.5 sq.mm PVC insulated copper wire and 1.5 sqmm PVC insulated copper earth wire from control box - 1 set.
215iii) Suitable size 20A DP MS Control box with 2 no. incoming and outgoings terminals and 2 nos. tap-out terminal with 1 nos. 5A HRC fuses complete 1 set.
216iv) Suitable number(s) 40mm dia Class-B GI Pipe(s) from above control box to upto 0.5 metre below ground level for power cable entry
217v) Providing 400x400x1000mm deep 1:3:6 ratio cement concrete including excavation shuttering alignment of poles casting etc. including 100mm thick lean concrete shall be provided at the bottom
218vi) Supply, installation, testing and commissioning of external post top lantern as mentioned above
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail