| 1 | S&F Colour coated anodised aluminium frame for dors,windows, ventilators,partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directedNote:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 2 | S&F Colour coated anodised aluminium doors shutters including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts, etc as required. complete all as specified and directedNote:-(i) Labour charges for fixing of glass/wire guage is inclusive in the unit rate quoted. Glass/Wire Guage/locks shall be measured and paidseperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 3 | S&F Colour coated anodised aluminium windows/ventilators/partitionsany type including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directedNote:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paidseperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 4 | Supply only 5.5mm thick tiintedglass, ordinary quality fixed with Aluminum frame workexc 0.5 sqm in each pane complete all as specified and as directed. |
| 5 | Supply only 4mm thick tiinted glass, ordinary quality fixed with Aluminum frame work n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 6 | Supply only 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed toAluminum frame work complete all as specified and as directed. |
| 7 | Supply only Mild steel4 lever, Mortice lock, vertical type, size 100 mm complete all as specified and as directed. |
| 8 | Supply only Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum window/ventilator shutters complete all as specified and as directed. |
| 9 | Supply only aluminium door closer hydraulically regulated designation No 3 universal type suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80Kg and fixed complete all as specified and as directed |
| 10 | Supply only Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed |
| 11 | Supply only 100mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11, complete all as specified and as directed |
| 12 | Supply only 18/19mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work complete all as specified and as directed. |
| 13 | S&F 12mm thick frosted tuffen glass, ordinary quality , including acid pitching work, desigining work etc, exc 0.5 sqm in each pane and fixed with suitable spigot/bracket to wall/ceiling/floor surfaces complete all as specified and as directed. |
| 14 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 15 | S&F mild steel MS tubes conforming to IS.1161-1979 grade St.-240 Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and as directed. |
| 16 | S&F Wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples, mesh size 20mm, complete all as specified and as directed. |
| 17 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 18 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, in soft/loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 19 | Excavating over areas, in sofl/loose soil,n exc 1.5 m deep and getting out complete all as specified and directed |
| 20 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable and getting out in soft/loose soil complete all as specified and directed. |
| 21 | Returning, filling in, including spreading,levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed. |
| 22 | Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed. |
| 23 | M&L PCC (1:4:8)type D-2 (using 40 mm graded stone aggregate) as in mass concrete complete all as specified and as directed. |
| 24 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in cement mortar 1:6 complete all as specified and as directed |
| 25 | M&L for rendering 15mm thick plastering in cement mortar (1:6) on on fair faces of brick work and finished the plastered surface fair and evenwithout using extra cement.complete all as specified and as directed. |
| 26 | M&L Hardcore of gauge n exc. 63 mm, using broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 27 | M&L 75mm thick PCC (1:4:8)type D-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed. |
| 28 | M&L 100mm thick PCC (1:2:4)type B-2 (using 40mm graded stone aggregate) as in floor finished even and fair complete all as specified and as directed. |
| 29 | M&L mild steel Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc..conforming to Fe.290.Gde-E-165 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 30 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 31 | S&F Prepainted galvalume aluminium zink coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed |
| 32 | M&L for preparation of new surface of any description and apply two coats of cement base paint over a coat of primer complete all as specified and directed |
| 33 | M&L for 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 34 | M&L colouredglazed ceramic tiles coloured in vertical surfaces 450x300x7mm thick, set and jointed in neat cement slurry and pointed in white and colour cement to match shade of tiles including 10mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed. |
| 35 | M&L for PCC (1:3:6)type C-2 (using 40 mm graded stone aggregate) as in surface channels and drain complete all as specified and as directed. |
| 36 | M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour codingdrawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etcincluding provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LSH (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modularswitch/ fittingsconcealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases andsinking for boxes and making good to the disturbed surfaceof wall/floor and matching with existing specifications, complete all as specified and as directed.Note:- Connections of cable with MCB\"s or bus bar shall be done through proper size copper/brassthimbles. |
| 37 | All as per item No 35here-in-above but for one 6 amps socket out let point on the same board with other switches |
| 38 | All as per item No 35here-in-above but for one 6 amps socket out let point on independent board. |
| 39 | M&L surface point wiring complete for one socket outlet 15/16 Amps point modular on independent board with4.00 Sqmm single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) multistranded PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI markd)with proper colour codingdrawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 4.00 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LSH (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modularswitch/ fittingsfixed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed includingsinking for boxes and making good to the disturbed surfaceof wall/floor and matching with existing specifications. Connections of cable with MCB\"s or bus bar shall be done through proper size copper/brassthimbles. all as specified and as directed. |
| 40 | M&L sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and PVC casing cappingmedium grade with accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including taking out old unserviceable submain wiring and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length.(ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 41 | S&F LED lights fitting 1x 120Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete all as specified and as directed. |
| 42 | S&F Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 43 | S&F Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed. |
| 44 | S&F Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 45 | S&F Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed. |
| 46 | S&F ceiling rose, PVC/ polycarbonate, isolated body, three terminals, complete all as specified and directed. |
| 47 | S&F stepped type modular electronic fan regulator 120 watt 2 module suitablefor 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed. |
| 48 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 doubledoor, Triple pole & neutral with 200 amps rated bus bar, including blanking plates as required andflush to wall surface including making good the distrubed surfaces of walls as per existing surfaces and finishes, complete all as specified and as directed. |
| 49 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 amps rated bus bar, including blanking plates as required andflush to wall surface including making good the distrubed surfaces of walls as per existing surfaces and finishes, complete all as specified and as directed. |
| 50 | S&F MCB Triple pole and Neutral, 63 amps, 240 volts, ‘C’ curve, 10 KAall complete as specified and as directed. |
| 51 | S&F MCB Single pole and Neutral, 6 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete as specified and as directed. |
| 52 | S&F MCB Single pole, 6 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete as specified and as directed. |
| 53 | S&F sheet metal encloser Plug and socket for suitable for 20 Amps SPN with and including 20 AmpsMCB andflush to wall surface complete all as specified and as directed. |