| 1 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Upto a depth of 2mbelow the existing ground level. In ordinary Soil. |
| 2 | Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.Brick on flat soling. |
| 3 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. byvolume). |
| 4 | 15 mm thick Cement plaster in single coat onsingle or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On rough side.In cement mortar 1:5 |
| 5 | Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). In sub - structure up to plinth level.Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. M20 grade concrete or prop. Without using admixture, plasticiser |
| 6 | Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). Super-structure from plinth level upto 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.M15 or Prop. 1:2:4. Without using admixture, plasticiser . |
| 7 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed in structure.In Sub-structure upto plinth level including dewatering if necessary.In proportion 1:3. |
| 8 | Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed in structure.In superstructure above plinth level up to 1st floor level. |
| 9 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc.complete. |
| 10 | Providing corrugated galvanised Iron sheet roofing of TATA Shaktee/SAIL including fitting and fixingnecessary galvanised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limset washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately).0.50 mm thickProviding corrugated galvanised Iron sheet roofing of TATA Shaktee/SAIL including fitting and fixing necessary galvanised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limset washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately).0.50 mm thick |
| 11 | Providing galvanised iron ridging of TATA SHAKTEE/SAIL including supplying and fixing necessary galvanised screws/washers etc. complete as directed. 0.50 mm thick and 150 mm lapping. Providing galvanised iron ridging of TATA SHAKTEE/SAIL including supplying and fixing necessary galvanised screws/washers etc. complete as directed. 0.50 mm thick and 150 mm lapping. |
| 12 | ROOF TRUSS. Providing fitting, hoisting and fixing of roof trusses using iron hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide, zinc chromate primer and two coats of approved enamel paints complete including fitting and necessary cleats etc. for fixing celling joists as per design and drawing as directed. Using other ISI marked approved circular hollow section. ROOF TRUSS. Providing fitting, hoisting and fixing of roof trusses using iron hollow sectionconforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide, zinc chromate primer and two coats of approved enamel paints complete including fitting and necessary cleats etc. for fixing celling joists as per design and drawing as directed. Using other ISI marked approved circular hollow section. |
| 13 | Providing wood work in frame (chow Kath) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40 mmx3mmx250mm) as per design embedded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. With 1st class timber(Bonsum/ Sundi). Providing wood work in frame (chow Kath) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40 mmx3mmx250mm) as per design embedded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. With 1st class timber (Bonsum/ Sundi). |
| 14 | Providing, fitting and fixing M.S. Grill of required pattern for windows/ clerestory windows/ opening with M.S flats at required spacing in frame all round, square or round M.S. bars with round headed bolts and nuts or screws. Plain Grill. Fixed to wooden frame. |
| 15 | Providing fitting and fixing 1st class local wood for panelled/ glazed doors and windows including supplying fitting and fixing iron fittings as detailed in A.P.W.D general specification except bim lock as directed. Full glazed windows and clearstory windows ( 30 mm thick). |
| 16 | Providing fitting and fixing A.C building board in ceiling with necessary nails, wood screws including 1st class local wood 50mm x 12mm (hollock/bonsum/sundi) beading including painting two coats to timber beads complete as directed. 4 mm thick. |
| 17 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank. |
| 18 | Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after thoroughly brushing the surface free from mortar droppings and other foreign matter and including preparing surface even and sand papered smooth.Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after thoroughly brushing the surface free from mortar droppings and other foreign matter and including preparing surface even and sand paperedsmooth. |
| 19 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed .With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m. |
| 20 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 21 | Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood) |
| 22 | Painting with oil type wood preservative of approved brand and manufacture New work (two or more coats) |
| 23 | Coal tarring two coats on new work using 0.16 litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. |
| 24 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 25 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., completeCeramic Glazed Tiles Ist quality 300 x 300 mm in all shades and designs of White,Ivory, grey, Fume Red brown etc. |
| 26 | Electrification @ 0.5 % of Civil Work Rs. 25380/- Approx |
| 27 | Display Sign Board |
| 28 | TIOLET : Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Upto a depth of 2m below the existing ground level. In ordinary Soil. |
| 29 | Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.Brick on edge soling |
| 30 | 15 mm thick Cement plaster in single coat onsingle or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On Fair side.In cement mortar 1:5. |
| 31 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).In prop. 1:4:8 (1 cement:4 coarse sand : 8 coarse agg. by volume |
| 32 | Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). In sub - structure up to plinth level.Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. M15 or Prop. 1:2:4.Without using admixture, plasticiser. |
| 33 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed in structure.In Sub-structure upto plinth level including dewatering if necessary.In proportion 1:3. |
| 34 | Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed in structure.In superstructure above plinth level up to 1st floor level |
| 35 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete |
| 36 | Providing wood work in frame (chow Kath) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40 mmx3mmx250mm) as per design embedded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. With 1st class timber (Bonsum/ Sundi). Providing wood work in frame (chow Kath) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40 mmx3mmx250mm) as per design embedded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. With 1st class timber (Bonsum/ Sundi). |
| 37 | Providing fitting and fixing 1st class local wood for panelled/ glazed doors and windows including supplying fitting and fixing iron fittings as detailed in A.P.W.D general specification except bim lock as directed. Full glazed windows and clearstory windows ( 30 mm thick). |
| 38 | Providing corrugated galvanised Iron sheet roofing of TATA Shaktee/SAIL including fitting and fixing necessary galvanised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limset washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately).0.50 mm thickProviding corrugated galvanised Iron sheet roofing of TATA Shaktee/SAIL including fitting and fixing necessary galvanised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limset washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately).0.50 mm thick |
| 39 | ROOF TRUSS. Providing fitting, hoisting and fixing of roof trusses using iron hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide, zinc chromate primer and two coats of approved enamel paints complete including fitting and necessary cleats etc. for fixing celling joists as per design and drawing as directed. Using other ISI marked approved circular hollow section.ROOF TRUSS. Providing fitting, hoisting and fixing of roof trusses using iron hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide, zinc chromate primer and two coats of approved enamel paints complete including fitting and necessary cleats etc. for fixing celling joists as per design and drawing as directed. Using other ISI markedapproved circular hollow section. |
| 40 | Providing fitting and fixing A.C building board in ceiling with necessary nails, wood screws including 1st class local wood 50mm x 12mm (hollock/bonsum/sundi) beading including painting two coats to timber beads complete as directed. 4 mm thick. |
| 41 | Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after thoroughly brushing the surface free from mortar droppings and other foreign matter and including preparing surface even and sand papered smooth.Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after thoroughly brushing the surface free from mortar droppings and other foreign matter and including preparing surface even and sand papered smooth. |
| 42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes |
| 43 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 44 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board470x420 mm bowl depth 178 mm |
| 45 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 46 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed .With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m. |
| 47 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank. |
| 48 | Providing fitting and fixing 1st class local wood for panelled/ glazed doors and windows including supplying fitting and fixing iron fittings as detailed in A.P.W.D general specification except bim lock as directed. Full glazed windows and clearstory windows ( 30 mm thick). |
| 49 | Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 50 | Providing, fitting and fixing M.S. Grill of required pattern for windows/ clerestory windows/ opening with M.S flats at required spacing in frame all round, square or round M.S. bars with round headed bolts and nuts or screws. Plain Grill. Fixed to wooden frame. |
| 51 | Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S flat iron with another horizontal flat at the middle, 20 mm dia M.S bars at 200 mm apart from bottom flat to top flat and 20 mm dia M.S bars at 200 mm apart from bottom flat to middle flat including drilling, welding etc. Complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flatteneded and pointed as directed. Necessary lockingarrangement on both faces, arrangement for temporary closing the gate and 2 nos.(minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in CC brick pillars as necessary including a red oxide painting toall iron works as directed and specified. (Separate payment will be made for posts). |
| 52 | ROOF TRUSS. Providing fitting, hoisting and fixing of roof trusses using iron hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide, zinc chromate primer and two coats of approved enamel paints complete including fitting and necessary cleats etc. for fixing celling joists as per design and drawing as directed. Using other ISI marked approved circular hollow section.ROOF TRUSS. Providing fitting, hoisting and fixing of roof trusses using iron hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide, zinc chromate primer and two coats of approved enamel paints complete including fitting and necessary cleats etc. for fixing celling joists as per design and drawing as directed. Using other ISI marked approved circular hollow section |
| 53 | Electrification |
| 54 | Display Sign Board |