Supply Of Cables - 1 1. General Item: 12 Triad Rtd Cable ( 1.0 Sqmm ) With Individual And Overall Screen And Armour Testing And Dimension Standards: Bs-5308, Is-8130, Is-1554 Voltage Class: 300 / 500V 2. Conductor Material: Annealed Tinned Copper Number Of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Triads Number Of Triads: 12 Nos Triad Arrangement : Twisted ( Uniformly ) Number Of Twists Per Meter: 10 Nos. Triad Number: Required ( At Interval Of Not More Than 250Mm ) 5. Individual And Overall Shield / Screen Material: Aluminium Backed Mylar / Polyester Tape Overlap / Coverage: 25% / 100% 6. Drain Wire ( Individual Pairs < ( >&< ) > Overall Shield ) Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder ( If Reqd. As Per Manufacturers Standard ) Wrapping Style : Helical 8. Filler ( If Reqd. As Per Manufacturers Standard ) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type St 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic Type, Below Inner Sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type St 2, Fire Retardant Low Smoke Communication Wire: Required 12. Colour Code Core 1 / Core 2 / Core 3 : Red / Yellow / Blue Sheath Outer / Inner: Green / Black Communication Pair : Red And Green 13. Drum Drum Length : 1000 Mtr Drum Length Tolerance : + / - 5% ( Negative Tolerance Is Not Acceptable On Total Ordered Quantity ) Marking On Cable: Length Of Cable To Be Marked At Interval Of Not More Than Five Meters On External Surface Of The Cable. 2 1. General Item: 1 Triad Rtd Cable ( 1.0 Sqmm ) With Screen And Armour Testing And Dimension Standards: Bs-5308, Is-8130, Is-1554 Voltage Class: 300V / 500V 2. Conductor Material: Annealed Tinned Copper Number Of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Triads Number Of Triads: 1 No Triad Arrangement : Twisted ( Uniformly ) Number Of Twists Per Meter: 10 Nos. 5. Shield / Screen Material: Aluminium Backed Mylar / Polyester Tape Overlap / Coverage: 25% / 100% 6. Drain Wire Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder ( If Reqd. As Per Manufacturers Standard ) Wrapping Style : Helical 8. Filler ( If Reqd. As Per Manufacturers Standard ) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type St 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic Type, Below Inner Sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type St 2, Fire Retardant Low Smoke 12. Colour Code Core 1 / Core 2 / Core 3 : Red / Yellow / Blue Sheath Outer / Inner: Green / Black 13. Drum Drum Length : 1000 Mtr Drum Length Tolerance : + / - 5% ( Negative Tolerance Is Not Acceptable On Total Ordered Quantity ) Marking On Cable: Length Of Cable To Be Marked At Interval Of Not More Than Five Meters On External Surface Of The Cable. 3 Cable, Instrument Power Pvc Sheathed, Pvc Insulated, Armoured Standard : Is 1554 / Is 694 Voltage : 650 V Conductor : Copper Type : Stranded No. Of Strands : 7 Armour Material : Galvanised Steel 1. General Item: 1 Pair Power Cable ( 1.5 Sqmm ) With Armour Testing And Dimension Standards: Is-8130, Is-1554 Voltage Class: 1.1Kv 2. Conductor Material: Annealed Tinned Copper Number Of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number Of Pairs: 1 Nos Pair Arrangement : Twisted Number Of Twists Per Meter: 10 Nos. 5. Shield / Screen: N / A 6. Drain Wire: N / A 7. Non Hygroscopic Binder ( If Reqd. As Per Manufacturers Standard ) Wrapping Style : Helical 8. Filler ( If Reqd. As Per Manufacturers Standard ) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type St 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic Type, Below Inner Sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type St 2, Fire Retardant Low Smoke 12. Colour Code Core 1 / Core 2: Red / Black Sheath Outer / Inner: Black / Black 13. Drum Drum Length : 1000 Mtr Drum Length Tolerance : + / - 5% ( Negative Tolerance Is Not Acceptable On Total Ordered Quantity ) Marking On Cable: Length Of Cable To Be Marked At Interval Of Not More Than Five Meters On External Surface Of The Cable. 4 1. General Item: 20 Pair Signal Cable ( 1.0 Sqmm ) With Individual And Overall Screen And Armour Testing And Dimension Standards: Is-8130, Is-1554, Bs-5308 Voltage Class: 300V / 500V 2. Conductor Material: Annealed Tinned Copper Number Of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number Of Pairs: 20 Nos Pair Arrangement : Twisted Number Of Twists Per Meter: 10 Nos. Pair Number: Required ( At Interval Of Not More Than 250Mm ) 5. Individual And Overall Shield / Screen Material: Aluminium Backed Mylar / Polyester Tape Overlap / Coverage: 25% / 100% 6. Drain Wire ( Individual Pairs And Overall Shield ) Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder ( If Reqd. As Per Manufacturers Standard ) Wrapping Style : Helical 8. Filler ( If Reqd. As Per Manufacturers Standard ) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type St 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic Type, Below Inner Sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type St 2, Fire Retardant Low Smoke Communication Wire: Required 12. Colour Code Core 1 / Core 2: White / Black Sheath Outer / Inner: Blue / Black Communication Pair : Red And Green 13. Drum Drum Length : 1000 Mtr Drum Length Tolerance : + / - 5% ( Negative Tolerance Is Not Acceptable On Total Ordered Quantity ) Marking On Cable: Length Of Cable To Be Marked At Interval Of Not More Than Five Meters On External Surface Of The Cable. 5 1. General Item: 12 Pair Power Cable ( 1.5 Sqmm ) With Armour Testing And Dimension Standards: Is-8130, Is-1554 Voltage Class: 1.1Kv 2. Conductor Material: Annealed Tinned Copper Number Of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number Of Pairs: 12 Nos Pair Arrangement : Twisted Number Of Twists Per Meter: 10 Nos. Pair Number: Required ( At Interval Of Not More Than 250Mm ) 5. Shield / Screen : N / A 6. Drain Wire: N / A 7. Non Hygroscopic Binder ( If Reqd. As Per Manufacturers Standard ) Wrapping Style : Helical 8. Filler ( If Reqd. As Per Manufacturers Standard ) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type St 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic Type, Below Inner Sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type St 2, Fire Retardant Low Smoke Communication Wire: Required 12. Colour Code Core 1 / Core 2: Red / Black Sheath Outer / Inner: Black / Black Communication Pair : Red And Green 13. Drum Drum Length : 1000 Mtr Drum Length Tolerance : + / - 5% ( Negative Tolerance Is Not Acceptable On Total Ordered Quantity ) Marking On Cable: Length Of Cable To Be Marked At Interval Of Not More Than Five Meters On External Surface Of The Cable. 6 1. General Item: 1 Pair Signal Cable ( 1.0 Sqmm ) With Screen And Armour Testing And Dimension Standards: Is-8130, Is-1554, Bs-5308 Voltage Class: 300V / 500V 2. Conductor Material: Annealed Tinned Copper Number Of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number Of Pairs: 1 Nos Pair Arrangement : Twisted Number Of Twists Per Meter: 10 Nos. 5. Shield / Screen Material: Aluminium Backed Mylar / Polyester Tape Overlap / Coverage: 25% / 100% 6. Drain Wire Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder ( If Reqd. As Per Manufacturers Standard ) Wrapping Style : Helical 8. Filler ( If Reqd. As Per Manufacturers Standard ) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type St 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic Type, Below Inner Sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type St 2, Fire Retardant Low Smoke Communication Wire: Required 12. Colour Code Core 1 / Core 2: White / Black Sheath Outer / Inner: Blue / Black 13. Drum Drum Length : 1000 Mtr Drum Length Tolerance : + / - 5% ( Negative Tolerance Is Not Acceptable On Total Ordered Quantity ) Marking On Cable: Length Of Cable To Be Marked At Interval Of Not More Than Five Meters On External Surface Of The Cable. 7 1. General Item: 2 Pair Signal Cable ( 1.0 Sqmm ) With Screen And Armour Testing And Dimension Standards: Is-8130, Is-1554, Bs-5308 Voltage Class: 300V / 500V 2. Conductor Material: Annealed Tinned Copper Number Of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Pair Number Of Pairs: 2 Nos Pair Arrangement : Twisted Number Of Twists Per Meter: 10 Nos. 5. Shield / Screen Material: Aluminium Backed Mylar / Polyester Tape Overlap / Coverage: 25% / 100% 6. Drain Wire Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder ( If Reqd. As Per Manufacturers Standard ) Wrapping Style : Helical 8. Filler ( If Reqd. As Per Manufacturers Standard ) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type St 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic Type, Below Inner Sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type St 2, Fire Retardant Low Smoke Communication Wire: Required 12. Colour Code Core 1 / Core 2: White / Black Sheath Outer / Inner: Blue / Black 13. Drum Drum Length : 1000 Mtr Drum Length Tolerance : + / - 5% ( Negative Tolerance Is Not Acceptable On Total Ordered Quantity ) Marking On Cable: Length Of Cable To Be Marked At Interval Of Not More Than Five Meters On External Surface Of The Cable. 8 1. General Item: 3 Core Signal Cable ( 1.0 Sqmm ) With Screen And Armour Testing And Dimension Standards: Is-8130, Is-1554, Bs-5308 Voltage Class: 300V / 500V 2. Conductor Material: Annealed Tinned Copper Number Of Strands: 7 Nos 3. Insulation Type: Poly Vinyl Chloride, Extruded, Type C 4. Core Number Of Cores: 3 Nos Arrangement : Twisted Number Of Twists Per Meter: 10 Nos. 5. Shield / Screen Material: Aluminium Backed Mylar / Polyester Tape Overlap / Coverage: 25% / 100% 6. Drain Wire Material: Annealed Tinned Copper Type: Stranded Size: 0.5 Sqmm 7. Non Hygroscopic Binder ( If Reqd. As Per Manufacturers Standard ) Wrapping Style : Helical 8. Filler ( If Reqd. As Per Manufacturers Standard ) 9. Inner Sheath Type: Poly Vinyl Chloride Extruded, Type St 2, Fire Retardant Low Smoke Rip Chord: Required, Non Metallic Type, Below Inner Sheath 10. Armour, Galvanised Steel Round Wire: Required 11. Outer Sheath Type : Poly Vinyl Chloride, Extruded, Type St 2, Fire Retardant Low Smoke Communication Wire: Required 12. Colour Code Core 1 / Core 2 / Core 3: White / Black / Red Sheath Outer / Inner: Blue / Black 13. Drum Drum Length : 1000 Mtr Drum Length Tolerance : + / - 5% ( Negative Tolerance Is Not Acceptable On Total Ordered Quantity ) Marking On Cable: Length Of Cable To Be Marked At Interval Of Not More Than Five Meters On External Surface Of The Cable.