Public Health Engineering Department-PHED has published Annual Rate Contract For Repair Of Lt Control Panel Installed At Various Tube Wells / Dug Wells / Pumping Stations In Jal Shakti Phe Division Akhnoor- 1 Disconnection Of Main Incoming Power Supply And Checking For Fault. 2 Making Of Tempora. Submission Date for this Tender is 13-07-2022. Bolts Tenders in akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 07-Jul-2022 | Date | Date | 13-07-2022 |
Sl. No. | Item Description |
1 | Disconnection of main incoming power supply and checking for fault. |
2 | Making of temporary arrangement for running of pumping machinery. |
3 | To and fro Manual carriage of the control panel from the site to the nearest roadside for loading into mechanical transport and vice versa |
4 | for total distance 0-1 km |
5 | for total distance 1-3kms |
6 | for total distance >3 kms |
7 | Providing & fitting of power contactor 25 Amp. |
8 | Providing & fitting of power contactor 40 Amp. |
9 | Providing & fitting of power contactor 50 Amp. |
10 | Providing & fitting of power contactor 70 Amp. |
11 | Providing & fitting of power contactor 80 Amp. |
12 | Providing & fitting of power contactor 95 Amp. |
13 | Providing & fitting of power contactor 110 Amp. |
14 | Providing & fitting of power contactor 140 Amp. |
15 | Providing & fitting of power contactor 185 Amp. |
16 | Providing & fitting of power contactor 225 Amp. |
17 | Providing & fitting of power contactor 250 Amp. |
18 | Providing & fitting of MCB 2 Amp. |
19 | Providing & fitting of MCB 6 Amp. |
20 | Providing & fitting of MCB 63 Amp. |
21 | Providing & fitting of MCB 100 Amp. |
22 | Providing & fitting of MCB 125 Amp. |
23 | Providing & fitting of MCB 160 Amp. |
24 | Providing & fitting of MCB 200 Amp. |
25 | Providing & fitting of MCB 250 Amp. |
26 | Providing & fitting of MCB 315 Amp. |
27 | Providing & fitting of MCB 400 Amp. |
28 | Providing & fitting of MCB 630 Amp. |
29 | Providing & fitting of MCB 800 Amp. |
30 | Providing and fitting of voltmeter of appropriate voltage range. |
31 | Providing and fitting of ammeter of appropriate current range. |
32 | Providing and fitting of ampere selector switch. |
33 | Providing and fitting of volt selector switch. |
34 | Providing and fitting of push button |
35 | Providing and fitting of indicator lamps |
36 | Providing and fitting of star delta timer. |
37 | Providing and fitting of fault analyzer. |
38 | Providing and fitting of delay timer. |
39 | Providing and fitting of star delta timer. |
40 | Making of incoming power connections to the repaired panel and checking on full load. |
41 | LT control Panel of capacity Upto 100 Amp. |
42 | Replacement of the circuit wiring |
43 | Providing & fitting of the terminal plate. |
44 | Providing & fitting of the power wiring. |
45 | Providing & fitting of the thermal overload relay. |
46 | Providing & fitting of the bus bar. |
47 | Providing & fitting of the bolted fuse link |
48 | Providing & fitting of the fuse holder suitable for the bolted fuse link. |
49 | LT control Panel of capacity Upto 125- 200 Amp. |
50 | Replacement of the circuit wiring |
51 | Providing & fitting of the terminal plate. |
52 | Providing & fitting of the power wiring. |
53 | Providing & fitting of the thermal overload relay. |
54 | Providing & fitting of the bus bar. |
55 | Providing & fitting of the bolted fuse link |
56 | Providing & fitting of the fuse holder suitable for the bolted fuse link. |
57 | LT control Panel of capacity Upto 225-300 Amp. |
58 | Replacement of the circuit wiring |
59 | Providing & fitting of the terminal plate. |
60 | Providing & fitting of the power wiring. |
61 | Providing & fitting of the thermal overload relay. |
62 | Providing & fitting of the bus bar. |
63 | Providing & fitting of the bolted fuse link |
64 | Providing & fitting of the fuse holder suitable for the bolted fuse link. |
65 | LT control Panel of capacity Upto 315-400 Amp. |
66 | Replacement of the circuit wiring |
67 | Providing & fitting of the terminal plate. |
68 | Providing & fitting of the power wiring. |
69 | Providing & fitting of the thermal overload relay. |
70 | Providing & fitting of the bus bar. |
71 | Providing & fitting of the bolted fuse link |
72 | Providing & fitting of the fuse holder suitable for the bolted fuse link. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy