Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing Vitrified tile & Enterance flooring after Dismentling of Existing Flooring |
| 2 | Dismantling glazed tiles (to be carefully removed). |
| 3 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in a |
| 4 | Grouting the joints of flooring tiles having joints of 3 mm width, using2mm to 3 mm gap using spacersand later this gap to be filled with cement basedgrout ) with Cement base grout and matching pigments etc., complete, including filling / grouting a |
| 5 | Providing and Laying Tactile Flooringfull body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed fini |
| 6 | Providing and Installation of Safety signage as per guideline for person with disability made ofretro reflectivesheeting as per colour specified and writing matter will be ofsame material in whitefixed / pasted over 4mm thick aluminum composite sh |
| 7 | Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and |
| 8 | Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an a |
| 9 | Extra labour for projected nosing of stair case of any shape and design |
| 10 | Providing and laying 50 mm wide antiskid tape made of slip resistant material colour contrast, edge strip, self adhesive to be fixed onfront edge of Stair treads to help people with visual disabliity and elderly even in dim light conditions &reduce th |
| 11 | Providing and laying 25 mm to 50mm wide high intensitiy reflective conspicuity tape colour contrast, edge strip, self adhesive to be fixed onfront edge of Stair riser to help people with visual disabliity and elderly even in dim light conditions &redu |
| 12 | Partition, Ceiling & Painting Work |
| 13 | Dismantling brick work tile, masonry or tile liningIn cement |
| 14 | 20mm thick cement plaster 1:4 in two coat work. |
| 15 | Providing and fixing partition 74 mm overall thickness partitionupto ceiling height consisting of G.I. frame and with 12 mm thick double BISON Board including providing and fixing of frame work made of special section power pressed/ role form G.I. sheet |
| 16 | Providing & fixing wooden Partition having internal frame work of sal wood section 50mm x 50mm, 6mm thick waterproof ply on both sides finished with 1mm thick mica complete as per architect drawing & as desired by Engineer-in-Charge |
| 17 | Providing & fixing wooden frame/Chowkhat for fixed glazing & Door Chowkhat having sal wood section 50mm x 50mm, 6mm thick waterproof ply on both sides finished with 1mm thick mica complete as per architect drawing & as desired by Engineer-in-Charge |
| 18 | Factory manufactured solid flush door fixed in positioniron hinges, etc . (excluding the cost of any fittings other than specified above but including the labour for fxing the same in position a) comercial with elm or gujan facing on both/sides with lam |
| 19 | Providing and fixing high pressure laminated sheet 1 mm thick. |
| 20 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 21 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respectGlazing area above 0.09 sqm |
| 22 | 5.0mm thick Plate glass (INDIAN) |
| 23 | Providing, fixing Glass frosted film on glass existing fixed at site complete as per specification & as desired by Engineer-in-Charge. |
| 24 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. III (size of door 851mm to 1000mm) |
| 25 | Supply & Fixing ofpressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet ofthe specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for |
| 26 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg/rmt |
| 27 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mmhaving thickness of1.25mm (18 gauge), shash bar MS Tee 25mm x 3mmwhere required joints mitered and elect |
| 28 | Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventila |
| 29 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in positi |
| 30 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.Glass panes 4mm thick above 0.40 sqm area. |
| 31 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminum doors including necessary cutting and making good etc. complete. |
| 32 | Providing and fixing beading to door and windows chowkats of commercial hard wood, such as Hollock, Champ, Chirassy Chaplash etc (Non coniferous timber other than teak conforming to ISI specification no 100., kiln seasoned) with iron screws, fixed in posi |
| 33 | Finishing ofbeading section 50mm x 12mm with Enamel paint two coat work with one coat of primer including preparation of surface complete as per specifications and as desired by Engineer-in-Charge. |
| 34 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all res |
| 35 | Providing and fixing SS Braile indicators of size 170mm x 35mm to be fixed on handrails of the the approved design and make having Braile dots raised 0.5mm above base plate, to the installed at the specified locations as per the directions of the Engineer |
| 36 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, F |
| 37 | With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 38 | Providing and Fixing ceiling consisting of 12.5mm thickGypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge. |
| 39 | Scraping White wash and colour wash |
| 40 | Providing and fixing of Back Panel of Reception comprising of framing of 50mm x 50mm Partal/ Sal wood or equivalent with 3mm thick backing of Bakelite sheet on wall side,6mm thick waterproof ply on both sides and front portion fixed with 1mm thick laminat |
| 41 | Providing & fixing 6mm thick BISON board waterproof paneling on wall with the help of PVC gatti & SS Screws upto 3\"-6\" high on periphery wall of inside hall complete as per drawing & desired by Engineer-in-Charge |
| 42 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. Including priming coat & preparation of surface |
| 43 | Providing & applying heritage granual homogeneous wall finishing system from Bakelite Coating & Paints Pvt. Consisting of two component system of dry Granual (25 kg/pack) made of 92% silice particle, coated with fade resistant pigmants and 100% acrylic co |
| 44 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 45 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 46 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 47 | Finishing walls with Premium Acrylic smooth exterior paintwith silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 48 | Removal of Existing damaged furniture & its carriage upto site provided by Administration including dosposal of malba from dismentling (Note :- But to be paid on actual basis after the certification of field officer) |
| 49 | Providing Signage & Providing New Colour ACP Sheet after Removing of existing ACP Sheets |
| 50 | Providing & fixing ACP Sheets of various thickness High Class ISI markedcomplete in all respect as per the directions of Engineer-in-charge.3mm thickACP Sheet |
| 51 | Dismentling of Existing ACP Sheet to be removed carefully so that based frame should not be damaged |
| 52 | Writing matter on front signage Using highintensityMicroprismaticgrade retroreflective SheetingType IV as per ASTM D 4956 09 and as per IRC 67 2012 |
| 53 | Providing and Fixing Name Plates of various sizes made of PVC sheet printed with self adhesive tape pasted on sunboard complete as desired by Engineer-in-Charge |
| 54 | Providing and Fixing Letters of “MOHALLA CLINIC” in SS 304 grade. Height and font as per approved drawing |
| 55 | Repair of Existing damages i.e regrading of tile terracing,replacement of glazing, replacement of chequred tile on ramp, replacement of parking pavers. |
| 56 | Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable mat |
| 57 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shap |
| 58 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
| 59 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement |
| 60 | Cost of new tile to be replaced instead of broken tiles in regrading of tile terracing including loading / unloading & all leads as desired by Engineer in charge . |
| 61 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 62 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 63 | Providing and fixing in position gratings 150mm x 150mmon top Khura PVC grating |
| 64 | Dismantling brick or flagged stone flooring without concrete base. |
| 65 | Providing and Laying Out DoorPrecast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints groute |
| 66 | Renewing glass panes with putty and nails wherever necessaryGlass panes weighing 10.75 Kg/sqm |
| 67 | Reception Counter including panneling on back complete |
| 68 | Providing and fixing at site the Reception Table plan dimensions as 5’-6” x 4’6” and height 2’-3” with storage, drawers, space for legs, etc complete as per drawing. The table should be sturdy and stable and will comprise of knot-free teak wood, wherever |
| 69 | Construction of Passage from Parking to Towards Toilet |
| 70 | Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per techn |
| 71 | Cement concrete 1:5:10 with 40 mm gauge stone ballast.using concrete mixing volumetric type |
| 72 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufacturedby block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete a |
| 73 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
| 74 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of ex |
| 75 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 76 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 77 | 20mm thick cement plaster 1:4 in two coat work. |
| 78 | Dismantling brick or flagged stone flooring without concrete base. |
| 79 | Providing and Laying Out DoorPrecast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints groute |
| 80 | Furniture Items |
| 81 | Chair for Reception- Providing and supplying medium back chair with ergonomic design, comfortable & aesthetically appealing. The seat and back shall be made of 15mm thick hot pressed commercial plywood padded with high resilience moulded polyurethane foam |
| 82 | Waiting Area chair 3 seater- Supplying & Placing three seater bench. The seat and back shall be made up of high quality cold rolled MS perforated sheet of 1.2mm thick, pressed and welded to form the shape. The seat and back electrostatically coated with e |
| 83 | Waiting Area chair 2 seater - Supplying & Placing two seater bench. The seat and back shall be made up of high quality cold rolled MS perforated sheet of 1.2mm thick, pressed and welded to form the shape. The seat and back electrostatically coated with ep |
| 84 | Doctor Table- Supplying & Placing executive table with credenza unit in completely knock down conditions with an overall size 1600mm X 1600mm X 750mm that is to be assembled at site. The worktop shall have the size 1950mm X 900mm made up of 25mm thick Pre |
| 85 | Main chair for Doctor- Providing and supplying a high back chair with ergonomic design, comfortable & aesthetically appealing. The seat and back shall be made of 15mm and 12mm thick hot pressed commercial plywood padded with high resilience moulded polyur |
| 86 | Visitor Chair for Doctor- Providing and supplying a visitor chair with ergonomic design, user comfort & aesthetically appealing. The seat and back shall be made of 15mm thick hot pressed commercial plywood padded with high resilience moulded polyurethane |
| 87 | Examination Table for Doctor Room -Two Section Top with Fix Mattress, Powder Coated, Overall Dimension - 1830mm X 560mm x 810mm |
| 88 | Stool for Doctor, Pharmacist Room & in SamplingRoom - Revolving Stool, SS Top, Powder Coated, Height Adjustable (510mm - 690mm). |
| 89 | Storage for Medicine - Providing, supplying and placing steel almirah. The overall size of the Almirah shall be 915mm (W) X 485mm (D) X 1980mm (H). The Almirah shall be supplied with 2 nos. of glass doors with4 nos. of adjustable shelves i.e. 5 loading |
| 90 | Customized Lab Table- Supplying & placing storage unit with an overall size 1800mm X 600mm X 900mm. It should be made up of Pre-laminated particle board of grade II of IS 12823 with approved laminate and finish as per approved shade. The top of the shutte |
| 91 | Providing and placing moveable 3-fold screen of MS fame with green coloured curtain, having arrangements that it can be removed for washing and refixed. The overall dimension of the 3-fold screen will be 1675mmx2450mm around examination table. The MS fram |
| 92 | Providing and fixing Roller Blinds at the designated locations with fabric/ texture approved by the Architect/ engineer-in-charge (170 sft *225/-) |
| 93 | Construction of Extra Parking |
| 94 | Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications. |
| 95 | Cement concrete 1:4:8 with 40 mm gauge stone ballast.using concrete mixing volumetric type |
| 96 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufacturedby block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. |
| 97 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
| 98 | PUBLIC HEALTH SERVICES |
| 99 | Sub Work-1 Internal Water Supply, Sewerage, Sanitation |
| 100 | Sub Head-1 Internal Sewerage System |
| 101 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type A |
| 102 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 103 | 75mm o/d single socket SWR UPVC pipe lines laid complete |
| 104 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 105 | For 110mm i/d pipes |
| 106 | Elbow 90 Degree (All side socketed) |
| 107 | Coupler |
| 108 | Single Tee With Door |
| 109 | For 75mm i/d pipes |
| 110 | Coupler |
| 111 | Floor Trap 110mm x 75mm |
| 112 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc.as per standard design minimumdepth of water should be 150 mm with a minimum seal 50mm. |
| 113 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 114 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 115 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 116 | Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. |
| 117 | uPVC Pipe 6 Kgf/cm250mm i/d |
| 118 | Sub Head-2 Internal Water Supply System |
| 119 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 120 | CPVC SDR 11 Pipe & fitting 16mm o/d |
| 121 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 122 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 123 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm |
| 124 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 125 | Through wall 22.86 cm thick |
| 126 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879in G.I. Pipe lines complete in all respect. |
| 127 | 15mm i/d G.I. Union |
| 128 | 20mm i/d G.I. Union |
| 129 | 25mm i/d G.I. Union |
| 130 | Painting G.I. Pipes and Specials with synthetic enamelPaint in all shades as per I.S.I. specification on existing or new work, two coats paints including cleaning rubbing surface, etc. |
| 131 | 15mm & 20mm i/d G.I. Pipe |
| 132 | 25mm & 32mm i/d G.I. Pipe |
| 133 | Sub Head - 3 Sanitary Installation |
| 134 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.Chinaware extended wall mounted E W.C.with matching chinaware cistern and seat cover complete in all respect. Detail attached as per Table-3 |
| 135 | Providing and fixing jet spray with 2\"-6\" long PVC pipe.With PTMT nut |
| 136 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 137 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tubeconnection 300 mm long complete. |
| 138 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
| 139 | Size 550 mm x 400 mm x 815mm |
| 140 | Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineer-in-charge) consisting of a pair of brackets, C.P. brasswaste 40mm complete in all respect. |
| 141 | Size 470mmx370mmx180mm |
| 142 | Providing & fixing 15 mm C.P brass laboratory cock swan neck of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 143 | Laboratory cock swan neck One Way |
| 144 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut |
| 145 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 146 | Providing and fixingin positiontowel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 147 | C.P brass towel ring |
| 148 | Providing and fixingin position C.P. brass soap dishof approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 149 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 150 | C.P. brass Bib cock long nose/ long body without flange |
| 151 | C.P Brass bib cock foam flow without flange |
| 152 | Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge)complete in all respect (instead of Pillar tap in Lavatory Suites). |
| 153 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 154 | C.P.brass 15mm Angle valve without flange |
| 155 | C.P.brass 15mm Concealed stop cock with flange |
| 156 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 157 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 158 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backingfixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on topcomplete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) |
| 159 | Providing and fixing in position premium range C.P. Brass Fittings and accessoriesof approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass Accessories: |
| 160 | C.P. brass toilet roll holder with flap |
| 161 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.Aluminium khunti with 3 pegs |
| 162 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks |
| 163 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod andPlastic Ball |
| 164 | Brass Ball Cock with rod andPlastic Ball 32mm i/d |
| 165 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 166 | G.I. tank nipple 25mmi/d |
| 167 | Construction of RCC BB Plateform on Roof for HDPE water storage tanks complete as per drawing & specifications & as desired by Engineer-in-Charge |
| 168 | For 1000 ltr Water Tank |
| 169 | Providing & Installation of SS table of Top size 6\"-6\"x2\"-0\"x 2\"-6\" high having provision of lab sink complete as per drawing & specifications as desired by Engineer-in-Charge |
| 170 | Sub Head-4 Flooring and Wall Tile |
| 171 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 172 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 173 | Providing and fixing 1st quality ceramic glazed wall tilesMatt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 174 | Sub Work-2 |
| 175 | Estate Sewerage |
| 176 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 177 | 110 mm o/d pipes |
| 178 | 160 mm o/d pipes |
| 179 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards,fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works,upto one chain (15m) complete in all respects. |
| 180 | For depthexceeding 3.0 m but not exceeding 3.0 m B.G.L.For all classes of soil except rocky |
| 181 | Sand Filling |
| 182 | Extra for making connections of all sizes newly laid sewers within benching of fully charged sewers including pluging of sewer, dewatering & desilting of manholes etc. complete in all respects. |
| 183 | Fire Fighting Equipment |
| 184 | Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.4.5kg capacity |
| 185 | Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity |
| 186 | ELECTRICAL SERVICES |
| 187 | Providing Internal Electrical Installations: |
| 188 | POINT WIRING: |
| 189 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 190 | Wiring fan point (withfan box ) |
| 191 | Wiring light point |
| 192 | Wiring call-bell point |
| 193 | Wiring6 Amp. wall socket point |
| 194 | Wiring6 Amp. Plug control comprising wall socket point |
| 195 | Wiring16/20 amp. power plug control point |
| 196 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPEWIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 197 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universalsocket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 198 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 199 | Wiring Telephone socket point RJ11 (one module) |
| 200 | Wiring Networking socket point RJ45 (one module) |
| 201 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 202 | Ceiling Rose (Flush Piano type) |
| 203 | Call Bell 220/230 volts AC Ding Dong |
| 204 | COPPER WIRES & CONDUIT PIPE: |
| 205 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 206 | Overall size 1sq.mm (Un-sheathed) |
| 207 | Overall size 1.5sq.mm (Un-sheathed) |
| 208 | Overall size 2.5sq.mm (Un-sheathed) |
| 209 | Overall size 4sq.mm (Un-sheathed) |
| 210 | Overall size 10sq.mm (Un-sheathed) |
| 211 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 212 | Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
| 213 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 214 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 215 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 216 | PVC flexible pipe 40mm dia. |
| 217 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 218 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 219 | G.I. EARTHING :- Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 220 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 221 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH):Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- |
| 222 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) |
| 223 | Copper Earthing |
| 224 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 225 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 226 | MCB\"S & MCB DISTRIBUTION BOARDS: |
| 227 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 228 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 229 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 230 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 231 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 232 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 233 | SP&NDouble Door Distribution Board 12 way each. |
| 234 | LT CABLES |
| 235 | XLPEINSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 236 | Overall size 16sq.mm (4 Core) Un-armoured (Loose) For PSPCL supply |
| 237 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 238 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 239 | MCCB\"s (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 240 | MCCB Four Pole 40/63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 241 | SHEET METAL IRON CLAD SWITCHES:Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure includingconnections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- |
| 242 | ICDP Switch 32amp., 415volts |
| 243 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES:Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:- |
| 244 | ICDP Changeover Switch 63amp., 415volts |
| 245 | AUTOMATIC VOLTAGE STABLIZER: |
| 246 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet boxof suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 247 | Automatic Voltage Stablizer 3 KVA |
| 248 | LED\"S FIXTURES & FANS: |
| 249 | Supply and erection of LED batten 20watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 250 | Supply and erection of LED batten 40watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 251 | Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser and efficacy of LED fixture minimum 100 lumens per watt complete in all respects as approved and desired by the Engineer in-charge at site. The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 252 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimum100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting\"s should beas approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 253 | Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear (IP 66 protection),THD< 10%, CRI minimum 70,High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon\"ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021 |
| 254 | Supply and erection of Ceiling Fan 1200mm (48\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. The fan should conform to Technical Specifications attached. |
| 255 | Supply and erection of Ventile Air Fan 225/230mm with aluminium louver shutter longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. The fan should conform to Technical Specifications attached. |
| 256 | SITC of Wall Fan Size 400MMcomplete in all respect as approved and desired by the Engineer in-charges at site. The fan should conform to Technical Specifications attached. |
| 257 | Providing -2Way Phone, Patient Token System,Local Area Networking : |
| 258 | Supply Installation Testing and Commissioningof10 port 10/100 PoE switch, 8*10/100 PoE port + 2 10/100 uplink, power budget 120W, IEEE 802.3af/atextended range 250 mtr completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 259 | Supply, installation, testing & commissioning of Category 6 UTP , 4 Pair This cable well exceeds the requirements of TIA/EIA-568-C.2 and IEC/ISO 11801. Construction: 4 twisted pairs separated by cross separator, 4 channel, polymer spine / full separator. Half shall not be accepted. Cable should be Armoured. Operates at bandwidth of 250 MHz, Conductor Solid Bare Electronic Grade Copper. Inner jacket should be PVC and outer should be PE, suitable for direct burial. Insulation: Polyethylene, Attenuation (< 36 db/100m), Pair – to – pair and PS NEXT, ELFEXT and PSELFEXT, Return Loss, ACR and PS ACR., Nominal Outer Diameter of Cable should be 9.70 mm and Conductor Diameter 0.56 mm (23 AWG), Cable should support operating Temperature from -20° to +60°C, Cable should come with printed sequential Length Counter on each meter, Cable support Conductor Resistance 93.5 OHMS/1000MTR@20 Degree, Mutual Capacitance of cable should be < 5.6nF/100m, Max Resistance Unbalance of cable should be 5% Max, Capacitance Unbalance of cable should max 330pF/100m, Cable support Delay Skew: < 45nS, Operating Voltage: 72V and NVP: 69%, Shall Supports Gigabit Ethernet (1000 base-T) standard and Operates at bandwidth of 250MHz complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 260 | Supply, installation, testing & commissioning of1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90%. .complete in all respects as approved and desired by the Engineer-in-charge at site |
| 261 | S/I/T/C of intercom facility 1+1 Basic Plan Phone Ringer volume control switch Tone/ Pulse Switchable Redial Mute Flash Pause Intercom facility Call T, Holding the line / Music on Hold during call transfer Line use LED Indication, Secrecy during conversation between both phones, including connecting cables complete in all respect as approved and desired by the Engineer in-charges at site |
| 262 | S/I/T/C of Token Calling Display System having screen size 4 inches, Voice calling/ Bell System, complete key pad Etc, calling display up to 60 meter cable (5 meter length included), serial communication design, Text Color Red Display Shape Rectangle,Power 5 W,Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital,Cash counter etc, Warranty 1 Year,220 VAC Operating Voltage Character Capacity 3 Character, Power Consumption,Rectangular Metal body,complete in all respect as approved and desired by the Engineer in-charges at site |
| 263 | Supply and erection of Wall Mounted 6U Rack with power point and fan. complete in all respect as approved and desired by the Engineer in-charges at site |
| 264 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 265 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 266 | Providing Double Door Refrigerator,Water Dispenser and Split air conditioner: |
| 267 | Supply,Installation and Comissioning of Frost Free Double Door Refrigerator capacity 250 Ltr - 265 Ltr complete in all respect. The Refrigerator shoud also conform to technical specifications attached herewith. Complete in all respect as approved and desired by the Engineer in-charges at site |
| 268 | Supply Instalation Testing and commisssioning of floor mounted Hot, cold and normal water3 Tap dispenser.The Water Dispenser should also conform tothe technical Specication Attached herewith.Complete in all respect as approved and desired by the Engineer in-charges at site |
| 269 | Supply, Installation and Comissioning of BEE 3 STAR/4STAR2.0 Ton split air conditioner with 100% coper coil material( evaporator and condensor). The Air Conditioner should also conform tothe technical Specication Attached herewith.Complete in all respect as approved and desired by the Engineer in-charges at site |
| 270 | Supply, Installation and Comissioning of BEE 3 STAR1.5 Ton split air conditioner with 100% coper coil material( evaporator and condensor) complete in all respect . The Air Conditioner should also conform tothe technical Specication Attached herewith. Complete in all respect as approved and desired by the Engineer in-charges at site |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy