Supply, Replacement Of Medium Intensity Aviation Obstruction Lights (Aol) And Restoration Of Aviation Light System Of Ndcts For 2X600mw, Sstpp, Mppgcl, Khandwa Supply, Replacement Of Medium Intensity Aviation Obstruction Lights (Aol) And Restoration Of Av, dongalia-Madhya Pradesh

Madhya Pradesh Power Generating Company Limited-MPPGCL has published Supply, Replacement Of Medium Intensity Aviation Obstruction Lights (Aol) And Restoration Of Aviation Light System Of Ndcts For 2X600mw, Sstpp, Mppgcl, Khandwa Supply, Replacement Of Medium Intensity Aviation Obstruction Lights (Aol) And Restoration Of Av. Submission Date for this Tender is 12-07-2022. Bolts Tenders in dongalia Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32900407
Supply, Replacement Of Medium Intensity Aviation Obstruction Lights (Aol) And Restoration Of Aviation Light System Of Ndcts For 2X600mw, Sstpp, Mppgcl, Khandwa Supply, Replacement Of Medium Intensity Aviation Obstruction Lights (Aol) And Restoration Of Av
Single
Indian
Madhya Pradesh
dongalia
12-07-2022

Tender Details

Supply, Replacement Of Medium Intensity Aviation Obstruction Lights (Aol) And Restoration Of Aviation Light System Of Ndcts For 2X600mw, Sstpp, Mppgcl, Khandwa Supply, Replacement Of Medium Intensity Aviation Obstruction Lights (Aol) And Restoration Of Aviation Light System Of Ndcts For 2X600mw, Sstpp, Mppgcl, Khandwa , Supply Portion , Ledmedium Intensity Aol • Model No.: Mi-Dx-1200 As Per Icao Type B • Input Voltage : 240 V Ac • Beam Angle : 360 Degree Horizontal • Burning Life: 100000 Hrs. • Designed Initial Flashing Effective Intensity : 4000 Cd • Colour : Red, Led Type : Allngap • Typical Power Consumption : 75 W • Piv Protection : 1 Kv Reverse Diode Protection • Insulation Resistance: More Than 10 Mohms At 500 Vdc , Dielectric Strength : 2.5 Kv , Led Low Intensity Aol • Model : A/Li 600 • Input Voltage : 240 V Ac • Colour : Red • Designed Radial (Directional) Intensity : = 65 Cd • Typical Power Consumption: 15 W Max. At 240 V Ac • Piv Protection : Leds Internally Protected Against Reverse Voltages Of Upto 1 Kv • Insulation Resistance : More Than 5 Megaohms At 500 Vdc • Dielectric Strength : 1.5 Kv For One Minute , Flasher Controller For 08 Nos. Mi Aol And 02 Nos. Of Low Intensity Aol , Work Portion , Execution (Installation, Testing, Commissioning) • Inspection And Fault Finding And Attending Of Aol System At El: 0 Meter And El: 165 Meter Simultaneously. • Removal Of Existing Faulty/ Damaged Fitting (Mi Aol And Li Aol) From Ndct. • Inspection And Fault Attending Of Power Cables. • Shifting Of New Fixtures To Its Amounting Locations. • Installation Of Medium Intensity Aol And Low Intensity Aol Fixtures With All Required Accessories And Hardware (Like : Ss Bracket, Fasteners, Nut Bolts. Etc.) • Termination Of Power Cables With Glands And Lugs. • Fabrication And Mounting Of 150 X75 Mm ‘C’ Channel Bracket For Flasher Synchronization Control And Mounting Controller. • Removal Of Damaged Controller And Installation, Termination Of Flasher Synchronization Control And Monitoring Controller Unit With All Accessories. • Testing And Commissioning Of Complete Aol System Of Ndct. • Fabrication, Installation Of Canopy For Flasher Synchronization Control And Monitoring Controller, Lighting Panel Etc. , Relocation Of New Controller 50 Meter Apart From Ndt For Prevention From Corrosion. Scope Of Work As Below: • Excavation Of Trench Size 500X1000 Mm (Width X Depth) For Cables Approx 50 Meter For Each Ndct. • Laying And Termination Of Power And Control Cables From Old To New Location For Extended Length Approximately 150 Meter For Each Ndct. • Back Filling Of Trench And Fixing Of Root Marker On Cable Root. • Jointing Of Cable With Jointing Kit. Quantity 04 Nos. Joints. • Clean And Furnish Area Of 5.5 Meter For New Location Of Flasher Synchronization Control And Monitoring Controller, Lighting Panel. Etc.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 23.05 Lakhs /-

BOQ Items

Name of Work: Supply, replacement of Medium Intensity Aviation Obstruction lights (AOL) andrestoration of aviation light system of NDCTs for 2x600MW, SSTPP, MPPGCL, Khandwa.
Sl. No. Item Description
1Supply portion
2LEDMedium intensity AOL • Model No.: MI-Dx-1200 as per ICAO type B • Input Voltage : 240 V AC • Beam angle : 360 Degree Horizontal • Burning life: 100000 Hrs. • Designed initial flashing effective Intensity : 4000 Cd • Colour : Red, LED type : AllnGaP • Typical power consumption : 75 W • PIV protection : 1 KV Reverse Diode Protection • Insulation resistance: More than 10 Mohms at 500 VDC , Dielectric strength : 2.5 KV
3LED Low intensity AOL • Model : A/LI 600 • Input Voltage : 240 V AC • Colour : Red • Designed radial (directional) intensity : = 65 Cd • Typical power consumption: 15 w max. at 240 V AC • PIV protection : LEDs internally protected against reverse voltages of upto 1 kV • Insulation resistance : More than 5 Megaohms at 500 VDC • Dielectric strength : 1.5 KV for one minute
4Flasher controller for 08 nos. MI AOL and 02 nos. of Low intensity AOL
5Work Portion
6Execution (Installation, testing, commissioning) • Inspection and fault finding and attending of AOL system at EL: 0 meter and EL: 165 meter simultaneously. • Removal of existing faulty/ damaged fitting (MI AOL and LI AOL) from NDCT. • Inspection and fault attending of power cables. • Shifting of new fixtures to its amounting locations. • Installation of Medium intensity AOL and Low intensity AOL fixtures with all required accessories and hardware (Like : SS bracket, Fasteners, nut bolts. Etc.) • Termination of power cables with glands and lugs. • Fabrication and mounting of 150 x75 mm ‘C’ channel bracket for flasher synchronization control and mounting controller. • Removal of damaged controller and installation, termination of flasher synchronization control and monitoring controller unit with all accessories. • Testing and commissioning of complete AOL system of NDCT. • Fabrication, installation of canopy for flasher synchronization control and monitoring controller, lighting panel etc.
7Relocation of new controller 50 meter apart from NDT for prevention from corrosion. Scope of work as below: • Excavation of trench size 500x1000 mm (Width x Depth) for cables approx 50 meter for each NDCT. • Laying and termination of power and control cables from old to new location for extended length approximately 150 meter for each NDCT. • Back filling of trench and fixing of root marker on cable root. • Jointing of cable with jointing kit. Quantity 04 nos. joints. • Clean and furnish area of 5.5 meter for new location of flasher synchronization control and monitoring controller, lighting panel. Etc.