Directorate Of Municipal Administration-DMA has published Supplying, Erecting Material And Maintance For 350 Hp Vtt ( Pump, Motor, Starter ) , 250 Hp Cf ( Pump, Motor, Starter ) And Other Mechanical / Electrical Maintance Of Water Supply Scheme For M C Hingoli. Repairs of 350 HP VSS Water l. Submission Date for this Tender is 04-07-2022. Bolts Tenders in hingoli Maharashtra. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Repairs of 350 HP VSS Water lubricated VT Pump (Head Work Sidheshwar) |
2 | Complete Removing 350 HP VT Motor |
3 | Complete Removing 350 HP VT Pump |
4 | Dismentlling of Bowl Assembly |
5 | Providing and fixing Bowl bush (Bronze) |
6 | Providing and fixing Bowl Necking (GM) |
7 | Providing and fixing Pump Shaft (S.S) |
8 | Providing and fixing Pump Shaft sleeve (S.S) |
9 | Providing and fixing Bowl Assembly Nut Bolt to Complet Assembly |
10 | Providing and fixing line shaft (S.S) |
11 | Providing and fixing line shaft sleeve (S.S) |
12 | Providing and fixing Spider(C.I.) |
13 | Providing and fixing Spider Ruber Bush |
14 | Providing and fixing gland bush (G.M.) |
15 | Providing and fixing chember bearing |
16 | Providing and filing chember oil |
17 | Providing and filing chember oil chember bush |
18 | Providing andfixing columpipe nut bolt |
19 | providign and fixing colum pipe ‘O’ ring |
20 | providing and fixing line shaft coupling |
21 | providing and fixing line shaft catchier |
22 | providing and fixing Coupling Bush |
23 | providing and fixing Pinion bush coupling |
24 | complete pump Errection |
25 | Pump test and trial charges |
26 | Transportation charges from site to workshop and back |
27 | Repairs 240 HP centrifegal pump (Digras W.T.P.) |
28 | Dismentlling of 240 HP C/F Pump |
29 | Providing and fixing 240 HP C/FPump Impeller (Bronze) |
30 | Providing and fixing Pump Shaft |
31 | Providing and fixingball bearing SKF 6311 |
32 | Providing and fixing bearing Housing |
33 | Providing and fixing Shaft sleeve (GM) |
34 | Providing and fixingNecking (GM) |
35 | Providing and fixing water ring (GM) |
36 | Providing and fixing Gland (GM) |
37 | Providing and fixing Nut bolt |
38 | providing and fixing Coupling Bush |
39 | providing and fixing Pinion bush coupling |
40 | Providing and fixing Gland rope |
41 | Re assmbling of Pump |
42 | Test and run charges |
43 | Repairs of 350 HP VSS Motor |
44 | Removing of 350 HP VSS Motor |
45 | Complete rewinding of 350 HP VSS Motor with supper enameled copper wire ‘f’ Class insulation material heating beaking varnishing complete job including scrap material |
46 | 350 HP VSS Motor heating beaking varnishing serving complete job |
47 | 350 HP VSS Motor complete servicing |
48 | Providing and fixing 350HP motor upper ball bearing SkF |
49 | Providing and fixing 350HP motor lower ball bearing SkF |
50 | providing and fixing motor connection plate fiber as per sample |
51 | providing, fixing and replacement of foundation Nut Bolts |
52 | Re assemble of 350 HP VHS motor |
53 | Test and run charges of 350 HP motor |
54 | Transportation charges from site to workshop and back |
55 | Repairs of 240 HP Foot mounted motor |
56 | Removing of 240 HP Foot mounted Motor |
57 | Complete rewinding of 240 HPFoot mounted Motor with supper enameled copper wire ‘f’ Class insulation material heating beaking varnishing complete job including scrap material |
58 | 240 HPFoot mounted Motor heating beaking varnishing servcing complete job |
59 | 240 HPFoot mounted Motor complete servicing |
60 | Providing and fixing 240 HP motor upper ball bearing SkF |
61 | Providing and fixing 240 HP motor lower ball bearing SkF |
62 | providing and fixing motor connection plate fiber as per sample |
63 | providing, fixing and replacement of foundation Nut Bolts |
64 | Re assemble of 240 HPFoot mounted Motor motor |
65 | Test and run charges of 240 HP Foot mounted Motor |
66 | Transportation charges from site to workshop and back |
67 | Re assembly of 240 HP motor |
68 | Transportation charges from site to workshop and back |
69 | Repairs of 350 HP ATS Assembled Automatic Starter |
70 | Complete Rewiring of 350 HP ATS Assembled starter with 2.5 sq.mm copper with luggs etc. |
71 | providing and fixing 1050 Amp contactor sparekit |
72 | providing and fixing 400 Amp contactor sparekit |
73 | providing and fixing 600 Amp contactor sparekit |
74 | providing and fixing 1050 Amp contactor coil |
75 | providing and fixing 400 Amp contactor coil |
76 | providing and fixing 600 Amp contactor coil |
77 | Providing and fixing CT oprated Relay Suitable for 350 HP starter |
78 | Providing and fixing ON delay Off Delay Timer |
79 | providing and fixing MPRD2 |
80 | providing and fixing 5 Amp Ct minilec |
81 | providing and fixing 6 Amp MCB single pole |
82 | providing and fixing auxillary contactor kitfor 1050 Amp contactor |
83 | providing and fixing auxillary contactor kit for 400 Amp contactor |
84 | providing and fixing auxillary contactor kitfor 600 Amp contactor |
85 | providing and Crimping 400 Sq mm Aluminium Luggs |
86 | providing and fixing Add On Block |
87 | providing and fixing LED Indicator |
88 | providing and fixing Amp Meter |
89 | providing and fixing volt meter |
90 | providing and fixing VSS |
91 | providing and fixing ASS |
92 | providing and fixing ON Push button |
93 | providing and fixing OF Push button |
94 | providing and fixing NO-NC |
95 | Transportation Charges site to workshop and back |
96 | Supplying and erecting120 sqm 3 core Aluminium conductor, XLPE /PVC-3.3kV ,armoured cable complete. |
97 | Supplying and erecting400 sqm 3 core Aluminium conductor, XLPE /PVC-3.3kV ,armoured cable complete. |
98 | Repaiers of 240 HP ATS Assembled Automatic Starter |
99 | Complete Rewiring of 240 HP ATS Assembled starter with 2.5 sq.mm copper with luggs etc. |
100 | providing and fixing 800 Amp contactor sparekit |
101 | providing and fixing 400 Amp contactor sparekit |
102 | providing and fixing 600 Amp contactor sparekit |
103 | providing and fixing 800 Amp contactor coil |
104 | providing and fixing 400 Amp contactor coil |
105 | providing and fixing 600 Amp contactor coil |
106 | Providing and fixing CT oprated Relay Suitable for 240 HP starter |
107 | Providing and fixing ON delay Off Delay Timer |
108 | providing and fixing MPRD2 |
109 | providing and fixing 5 Amp Ct minilec |
110 | providing and fixing 6 Amp MCB single pole |
111 | providing and fixing auxillary contactor kitfor 800Amp contactor |
112 | providing and fixing auxillary contactor kit for 400 Amp contactor |
113 | providing and fixing auxillary contactor kitfor 600 Amp contactor |
114 | providing and Crimping 300 Sq mm Aluminium Luggs |
115 | providing and fixing Add On Block |
116 | providing and fixing LED Indicator |
117 | providing and fixing Amp Meter |
118 | providing and fixing volt meter |
119 | providing and fixing VSS |
120 | providing and fixing ASS |
121 | providing and fixing ON Push button |
122 | providing and fixing OF Push button |
123 | providing and fixing NO-NC |
124 | Transportation Charges site to workshop and back |
125 | Supplying and erecting120 sqm 3 core Aluminium conductor, XLPE /PVC-3.3kV ,armoured cable complete. |
126 | Supplying and erecting 300 sqm 3 core Aluminium conductor, XLPE /PVC-3.3kV ,armoured cable complete. |
127 | Repairs and Rewinding of 350 HP Auto Transformer |
128 | Repairs and Rewinding of 350 HP Auto Transformer with Supper enameled and BCC copper wire varnishing Heating,becking with tapping 0%, 50%,65%,85% and 100% including scrap material |
129 | Transportation Charges site to workshop and back |
130 | Repairs and Rewinding of 240 HP Auto Transformer |
131 | Repairs and Rewinding of 240 HP Auto Transformer with Supper enameled and BCC copper wire varnishing Heating,becking with tapping 0%, 50%,65%,85% and 100% including scrap material |
132 | Transportation Charges site to workshop and back |
133 | Repair Air Blower |
134 | Complete Repair air blowe |
135 | Repair Vaccum Pump parts |
136 | 3 HP Vaccum pump complete repairs |
137 | 3 HP Vaccum pump starterrepairs |
138 | Repair Clarifloculator parts |
139 | Repairs of Gear box of floculator. |
140 | New Gear box floculator. |
141 | Repairs of Gear box motor floculator. |
142 | Repairs of Stater of clarrifloculator |
143 | Repairs of Bridge Gear box Clarifloculator. |
144 | New Bridge Gear box Clarifloculator. |
145 | Repairs of Bridge Gear box motor Clarifloculator. |
146 | Repairs of Gear box of flash mixer |
147 | New Gear box flash mixer |
148 | Repairs of Motor of flash mixer |
149 | New Motor of flash mixer |
150 | New of Bridge Gear box motor Clarifloculator. |
151 | Repairs of Gates |
152 | 500 kva 33 kv Substaion |
153 | 500 kva Transformer winding |
154 | Oil Filteration of Tranormer |
155 | Oil Top up per Liter |
156 | Providing and replacement of Breather |
157 | Providing and replacement DO Fuse for 33 kv |
158 | Providing and replacement 33 Kv LA set |
159 | Providing and replacement 33 kv AB switch |
160 | Providing and replacement 33 kv 120 sqm end termination kit Indoor |
161 | Providing and replacement 33 kv 120 sqm end termination kit Outdoor |
162 | 400 kva 33 kv Substaion |
163 | 400 kva Transformer winding |
164 | Oil Filteration of Tranormer |
165 | Oil Top up per Liter |
166 | Providing and replacement of Breather |
167 | Providing and replacement DO Fuse for 33 kv |
168 | Providing and replacement33 Kv LA set |
169 | Providing and replacement 33 kv AB switch |
170 | Providing and replacement33 kv 120 sqm end termination kit Indoor |
171 | Providing and replacement 33 kv 120 sqm end termination kit Outdoor |
172 | MCC cum APFC Panel |
173 | providing and fixing Multifuction meter |
174 | providing and fixing VCB 1000 Amp L&T make |
175 | providing and fixing VCB 800 Amp L&T make |
176 | providing and fixing VCB 1600 Amp L&T make |
177 | Complete Overhauling and servicing VCB 1000 Amp L&T make |
178 | Complete Overhauling and servicing VCB 800 Amp L&T make |
179 | Complete Overhauling and servicing VCB 1600 Amp L&T make |
180 | providing and fixing APFC relay 16 points |
181 | providing and fixing Gas filled capacitor 25 kvar |
182 | providing and fixing Gas filled capacitor 50 kvar |
183 | providing and fixing Gas filled capacitor 100 kvar |
184 | Repairs of 20 HP Foot mounted motor |
185 | Removing of 20HP Foot mounted Motor |
186 | Complete rewinding of 20 HPFoot mounted Motor |
187 | 20 HPFoot mounted Motor heating beaking varnishing servcing complete job |
188 | 20 HPFoot mounted Motor complete servicing |
189 | Providing and fixing 20 HP motor upper ball bearing |
190 | Providing and fixing 20 HP motor lower ball bearing |
191 | providing and fixing motor connection plate fiber as per sample |
192 | providing, fixing and replacement of foundation Nut Bolts |
193 | Test and run charges of 20 HP Foot mounted Motor |
194 | Transportation charges from site to workshop to site |
195 | Repairs of 20 HP ATS Assembled Automatic Starter |
196 | Completerewinding of 20 HP ATS Assembled starter with 2.5 sq.mm copper with luggs etc. |
197 | providing and fixing 1050 Amp contactor sparekit |
198 | providing and fixing 400 Amp contactor sparekit |
199 | providing and fixing 600 Amp contactor sparekit |
200 | providing and fixing 1050 Amp contactor coil |
201 | providing and fixing 400 Amp contactor coil |
202 | providing and fixing 600 Amp contactor coil |
203 | Providing and fixing CT oprated Relay Suitable for 20 HP starter |
204 | Providing and fixing ON delay Off Delay Timer |
205 | providing and fixing MPRD2 |
206 | providing and fixing 5 Amp Ct minilec |
207 | providing and fixing 6 Amp MCB single pole |
208 | providing and fixing auxillary contactor kitfor 1050 Amp contactor |
209 | providing and fixing auxillary contactor kit for 400 Amp contactor |
210 | providing and fixing auxillary contactor kitfor 600 Amp contactor |
211 | providing and Crimping 400 Sq mm AluminiumLuggs |
212 | providing and fixing Add On Block |
213 | providing and fixing LED Indicator |
214 | providing and fixing Amp Meter |
215 | providing and fixing volt meter |
216 | providing and fixing VSS |
217 | providing and fixing ASS |
218 | providing and fixing ON Push button |
219 | providing and fixing OF Push button |
220 | providing and fixing NO-NC |
221 | Supplying and erecting120 sqm 3 core Aluminium conductor, XLPE /PVC-3.3kV ,armoured cable complete. |
222 | Supplying and erecting400 sqm 3 core Aluminium conductor, XLPE /PVC-3.3kV ,armoured cable complete. |
223 | providing and fixing VCB 1000 Amp L&T make |
224 | providing and fixing VCB 800 Amp L&T make |
225 | providing and fixing VCB 1600 Amp L&T make |
226 | Complete Overhauling and servicing VCB 1000 Amp L&T make |
227 | Complete Overhauling and servicing VCB 800 Amp L&T make |
228 | Complete Overhauling and servicing VCB 1600 Amp L&T make |
229 | servicing of ATS assembled starter |
230 | servicing of APFC pannel |
231 | thrust bearing housing( CI) |
232 | cooling coil for 350hp pump(Copper) |
233 | spherical roller thrust bearing |
234 | oil retairner plate(MS) |
235 | o ring(Nitrile) |
236 | oil retainer bush(LTB-5) |
237 | thrust block(EN8) |
238 | thrust bearing lock nut(EN-8) |
239 | key (SS410) |
240 | thrust bearing cover(CI) |
241 | fastner for thrust bearing assembly set(HTS) |
242 | 240 hp motor rotar repairing with bearing |
243 | 240hp motor rotar throw |
244 | servicing of 240hp starter ATS |
245 | servicing of 350 hp starter ATS |
246 | test and run for starter |
247 | MNX32 contactor |
248 | MNX22contactor |
249 | 63 amp 3 pole mcb |
250 | MNX A1 |
251 | MNX A2 |
252 | TB 16 contactor |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy