Providing Iei And Eei In Incinerator Room At Gb Pant Hospital, Port Blair., blair-Andaman And Nicobar Islands

Andaman And Nicobar Islands Medical Education and Research Society-ANIMERS has published Providing Iei And Eei In Incinerator Room At Gb Pant Hospital, Port Blair.. Submission Date for this Tender is 04-07-2022. Building Work Tenders in blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

32855650
Providing Iei And Eei In Incinerator Room At Gb Pant Hospital, Port Blair.
Open Tender
Indian
Andaman And Nicobar Islands
blair
04-07-2022

Tender Details

Providing Iei And Eei In Incinerator Room At Gb Pant Hospital, Port Blair.

Key Value

Document Fees
Refer document
EMD
INR 6712.0 /-
Tender Value
INR 3.35 Lakhs /-

BOQ Items

Name of Work: Providing IEI & EEI in Incinerator room at GB Pant Hospital, Port Blair.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecorecableinsurface /recessedmediumclassPVC conduit, with modular switch, modular plate, suitable GI box and earthingthepointwith 1.5sq.mm FRLSPVC insulated copper conductor single core cable etc. as required.
2Group C
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
42 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
52 X 6 sq. mm + 1 X 6 sq. mm earth wire
64 X 6 sq. mm + 2 X 6 sq. mm earth wire
7Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
85/6 A switch
93 pin 5/6 A socket outlet
10Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
12Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
13Supplying and fixing 3pin, 5A ceiling rose on the existing junctionbox/woodenblockincludingconnectionsetc.as required.
14Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
15Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
16Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
17Upto 450 mm sweep
18Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
19Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator).
206 way , Double door
21Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
226 way (4 + 18), Double door
23Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required.
24Single pole
25Supplyingandfixingfollowingrating,doublepole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2640 A
27Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2840 A
29Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
30EarthingwithG.I.earthpipe 4.5metrelong,40mmdia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
31Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
32Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
33Upto 35 sq. mm
34Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3531/2 X 35 sq. mm (32mm)
36Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.
37Upto 120 sq. mm
38Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, boltsandwasher, paintingtheflatiron withprimerand paint etc. as required.
39Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
4090 mm dia (OD-90 mm & ID-76 mm nominal)
41Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
4290 mm dia (OD-90 mm & ID-76 mm nominal)
43Supplying of ISI mark single phase, Heavy duty Metal Exhaust fan with 450mm sweep and 900rpm. Make USHA, Turbo HDEF or equivalent.
44Supplying of Metal Air Circulator, Heavy duty wall fan of600mm sweep. Make : Usha, Dominaire or equivalent.
45Suppying of Industrial Batten suitable for 1x4 feet LED tube, Make: Philips,Type:TMC 501 P 1xT-LED 22W P3241 or equivalent.
46Supplying of 20W, 2100 lumen, T8 LED tube with Polycarbonate housing , Make: Philips, Model:Essential LEDtube 1200mm 20W865 T8 IND I – 2100lm
47Supplying of ISI mark 1 star AC ceiling of 1200mm sweep of Make : USHA, Energia or equivalent.
48Supplying and fixing of 35W LED street Light with minimum 3500 lumen. Make : Philips,Smart Bright Essential, Type: BRP030 LED35
49Supplying of G.I Pipe 80 mm (Medium Class).
50Supplying of one number XLPE insulated PVC outer sheathed with galvanised round steel wire or steel srtip armoured aluminium conductor power cable of 1.1 Kv grade of following size conforming to IS 1554 (Part-I) 1988 amended upto date.
5135 Sq.mm x 31/2 Core.
52Supplying andFixing DWC HDPE pipe of following size ISI marked along with all accessories like socket, bend, couplers etc.Conforming to IS 16205 (Part -24-2018 ) complete with fitting and cutting, jointing etc. on surface/wall including suitable clamping arraengements etc as required.
53110 mm dia (OD-110mm&ID-95 mm normal)
54LayingandfixingofonenumberPVCinsulatedandPVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
55Upto 35 sq. mm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail