| 1 | Chemical analysis ferrous by Wet Analysis – Nitrogen, Boron and Palladium |
| 2 | Chemical analysis ferrous by Spectrometer – Up to 8 elements |
| 3 | Chemical analysis ferrous by Spectrometer – Each additional element above 8 |
| 4 | Chemical analysis Non-ferrous metals by wet analysis – Up to 5 elements |
| 5 | Chemical analysis Non-ferrous metals by wet analysis – Each additional element above 5 |
| 6 | Cylindrical Tensile Test (All Weld) with 02% proof stress with stress and strain diagram with electronic extensometer |
| 7 | Transverse Tensile Test (Perpendicular)/ tensile test |
| 8 | Tensile test of pipe/profile at high temperature |
| 9 | Bend Test on Weld test Coupons |
| 10 | Weld/Pipe/raw materialMacro exmanition withoutphotograph |
| 11 | Weld/Pipe/raw materialMacro exmanition withphotograph |
| 12 | Shear Test (Pull out test) for brazed assembly |
| 13 | Impact Test with Charpy ‘v’ notch for weld zone and Heat affected zone. Temperature Upto - 800 C |
| 14 | Hardness Test Rockwell/Brinnel/Vickers |
| 15 | 20 Point Testing for galvanized pipe samples for determining Zinc % over 20 mm length and over a 10 micron thickness of eta layer( 3 locations) |
| 16 | Micro structural inspections on a 20 mm length area on each microscopic section (Nital 0.2% etching) for determining % of porosity for galvanized pipes/plates at 500X magnification |
| 17 | PMI for identification of material on daily basis( Half day) |
| 18 | PMI for identification of material on daily basis( Full day) |
| 19 | Proof load test on fasteners (bolts) |
| 20 | Proof load test on fasteners (nuts) |
| 21 | Diffusible Hydrogen Content Test |
| 22 | Moisture content test in the coated weld |
| 23 | In-Situ metallography |
| 24 | Portable optical emission spectrometer |
| 25 | Cyl. Tensile upto 40mm thk/dia (Ferrous) |
| 26 | Cyl. Tensile upto 40 mm (Non-ferrous) |
| 27 | Cyl. Tensile above 40mm (Ferrous) |
| 28 | Cyl. Tensile above 40mm (Non-Ferrous) |
| 29 | Trans Tensile upto 40mm (Ferrous) |
| 30 | Trans Tensile upto 40mm (Non-Ferrous) |
| 31 | Trans Tensile above 40mm (Ferrous) |
| 32 | Trans Tensile above 40mm (Non-Ferrous) |
| 33 | Bend test upto 40mm (Ferrous) |
| 34 | Bend test upto 40mm (Non-Ferrous) |
| 35 | Bend test above 40mm (Ferrous) |
| 36 | Bend test above 40mm (Non-Ferrous) |
| 37 | Impact Test upto 25mm thk/dia(Ferrous) |
| 38 | Impact Test upto 25mm th/dia(Nonferrous) |
| 39 | Impact Test above 25mm thk/dia(Ferrous) |
| 40 | Impact Test above25mm th/dia(Nonferrous) |
| 41 | Weld/Pipe/raw/material Macro upto 40mm (Ferrous) |
| 42 | Weld/Pipe/raw/material Macro upto 40mm (Non-Ferrous) |
| 43 | Weld/Pipe/raw/material Macro above 40 mm (Ferrous) |
| 44 | Weld/Pipe/raw/material Macro above 40 mm (Non-Ferrous) |
| 45 | Weld/Pipe/raw/material Micro upto 40mm thk (Ferrous) |
| 46 | Weld/Pipe/raw/material Micro upto 40mm thk (Non-Ferrous) |
| 47 | Weld/Pipe/raw/material Micro above 40mm thk(Ferrous) |
| 48 | Weld/Pipe/raw/material Micro above 40mm thk(Non-Ferrous) |
| 49 | Transportation Trips (To & Fro) |