Demolition Of P-1 Building And Construction Of Deficient Office Spaces And Store Alongwith Mt Pool For Cgdhq-4 At Kochi, kochi-Goa

Military Engineer Services-MES has published Demolition Of P-1 Building And Construction Of Deficient Office Spaces And Store Alongwith Mt Pool For Cgdhq-4 At Kochi. Submission Date for this Tender is 09-08-2022. Demolition Work Tenders in kochi Goa. Bidders can get complete Tender details and download the document.




Tender Notice

32763226
Corrigendum : Demolition Of P-1 Building And Construction Of Deficient Office Spaces And Store Alongwith Mt Pool For Cgdhq-4 At Kochi
Open Tender
Indian
Goa
kochi
09-08-2022

Tender Details

Demolition Of P-1 Building And Construction Of Deficient Office Spaces And Store Alongwith Mt Pool For Cgdhq-4 At Kochi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Jul-2022 82078AMDTODATES1 Date 02-08-2022
2 19-Jul-2022 82078REVISEDDRAWINGS Other 02-08-2022
3 19-Jul-2022 82078AMEDTTOTENDERPAGES Other 02-08-2022
4 20-Jul-2022 82078REVBOQ BOQ 02-08-2022
5 21-Jul-2022 82078REVBOQ2 BOQ 02-08-2022
6 21-Jul-2022 82078REVBOQ2 BOQ 02-08-2022
7 29-Jul-2022 82078AMEDTTOTENDER4 Other 02-08-2022
8 02-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-08-2022

Key Value

Document Fees
INR 3000 /-
EMD
INR 1025000.0 /-
Tender Value
INR 14 Crore /-

BOQ Items

Name of Work: DEMOLITION OF P-1 BUILDING AND CONSTRUCTION OF DEFICIENT OFFICE SPACES AND STORE ALONGWITH MT POOL FOR CGDHQ-4 AT KOCHI
Sl. No. Item Description
1GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XVI are prepriced by MES under Ser No. 1.00to 10.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
2Lumpsum price worked out by the contractor for "BUILDING & STRUCTURE WORKS” as listed in Schedule ‘A’ Part - I, inserted by MES
3Lumpsum price worked out by the tenderer for"SITE CLEARANCE & EARTH WORK EXCAVATION" as listed in Schedule "A" Part-II
4Lumpsum price worked out by the tenderer for "Internal Water Supply" as listed in Schedule ‘A’ Part-III
5Lumpsum price worked out by the tenderer for "Internal Electrification" as listed in Schedule ‘A’ Part-IV
6Lumpsum price worked out by the tenderer for "ROAD/PATH/HARDSTANDING" as listed in Schedule ‘A’ Part-V
7Lumpsum price worked out by the tenderer for"SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI
8Lumpsum price worked out by the tenderer for "AREA DRAINAGE"as listed in Schedule ‘A’ Part-VII
9Lumpsum price worked out by the tenderer for "HIGH SECURITY WALL"as listed in Schedule ‘A’ Part-VIII
10Lumpsum price worked out by the tenderer for "External Water Supply" as listed in Schedule ‘A’ Part-IX
11Lumpsum price worked out by the tenderer for "External Electrification" as listed in Schedule ‘A’ Part-X
12Lumpsum price worked out by the tenderer for "DIESEL GENERATOR SET"as listed in Schedule ‘A’ Part-XI
13Lumpsum price worked out by the tenderer for "LIFT"as listed in Schedule ‘A’ Part-XII
14Lumpsum price worked out by the tenderer for "LIGHTNING PROTECTION"as listed in Schedule ‘A’ Part-XIII
15Lumpsum price worked out by the tenderer for "AVIATION OBSTRUCTION LIGHT"as listed in Schedule ‘A’ Part-XIV
16Lumpsum price worked out by the tenderer for "LAN/TELEPHONE CONNECTION"as listed in Schedule ‘A’ Part-XV
17Lumpsum price worked out by the tenderer for "FIRE FIGHTING"as listed in Schedule ‘A’ Part-XVI
18NOTE:Schedule ‘A’ Part - XVII is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
19SCHEDULE `A" PART - XVII (MISCELLANEOUS ITEMS)
20INTERNAL WATER SUPPLY
21Supply and fixing, 15mm Dia Angle Stop valves, cast copperalloy,fancytype,chromium plated with long shank and cup screwed down, highpressure, with crutch orbutterfly handle, screwed bothendsforironpipeorforunions and fixed complete all as specified and directed.
22Supply and fix self closing tap,castcopper alloy chromium plated screwed for iron pipe 15mm bore complete all as specified and as directed.
23Supply and fix Bib tap cast copper alloy CP, two way with capstan handle, screwed down, screwedfor 15 mm bore iron pipe or for brass ferrule and fixed, complete, all as specified.
24INTERNAL ELECTRIFICATION
25Supply and fixing, connecting and testing MCB triple Pole and neutral (MCB TPN) 415 volts, 50 Hzof capacity 63 Amps, D curve complete all as specified and directed. Make: Legrand/Indo Asian/Havells/L&T/ABB
26Supply and fixing, connecting and testing MCB Single Pole (MCB SP) 220volts of capacity 6 to 40 Amps, 10Ka C curve complete all as specified and directed. Make: Legrand/Indo Asian/Havells/L&T/ABB
27Material and Labour for Sub main wiring with 4 runs of 16 sqmm single core, multistranded PVC insulated unsheathed cable FRLS 1100 volts grade with copper conductor, drawn in and including concealed rigid PVC conduit not less than 32 mm dia, conduit fittings and accessories concealed in wall/ roof/floor with two runs of 16 sqmm (2X16 Sqmm) PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified and directed. Note : 4 runs of cable, 2 runs of earth wire and one run of conduit shall be measured as one length.
28Material and Labour for Sub main wiring with 4 runs of 10 sqmm single core, multistranded PVC insulated unsheathed cable FRLS 1100 volts grade with copper conductor, drawn in and including concealed rigid PVC conduit not less than 32 mm dia, conduit fittings and accessories concealed in wall/ roof/floor with two runs of 10 sqmm (2X10 Sqmm) PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified and directed. Note : 4 runs of cable, 2 runs of earth wire and one run of conduit shall be measured as one length.
29Material and Labour for sub main wiring (concealed type) complete with two runs of 1100 volts grade heavy duty cable FRLS PVC insulated & unsheathed copper conductor, multi- stranded single core of 10 Sqmm including with one run of 10 Sqmm single core PVC insulated & unsheathed multistranded copper conductor cable as earth continuity conductor, drawn in rigid non-metallic PVC conduit of suitable dia, conduct fitting & accessories all as specified and directed. Note : 2 run of cable, 1 run of earth wire and one run of conduit shall be measured as one length.
30Material and Labour for sub main wiring (concealed type) complete with two runs of 1100 volts grade heavy duty cable FRLS PVC insulated & unsheathed copper conductor, multi- stranded single core of 6 Sqmm including with one run of 6 Sqmm single core PVC insulated & unsheathed multistranded copper conductor cable as earth continuity conductor, drawn in rigid non-metallic PVC conduit of suitable dia, conduct fitting & accessories all as specified and directed. Note : 2 runs of cable, 1 run of earth wire and one run of conduit shall be measured as one length.
31Material and Labour for sub main wiring (concealed type) complete with two runs of 1100 volts grade heavy duty cable FRLS PVC insulated & unsheathed copper conductor, multi- stranded single core of 4 Sqmm including with one run of 4 Sqmm single core PVC insulated & unsheathed multistranded copper conductor cable as earth continuity conductor, drawn in rigid non-metallic PVC conduit of suitable dia, conduct fitting & accessories all as specified and directed. Note : 2 runs of cable, 1 run of earth wire and one run of conduit shall be measured as one length.
32Supply and fix Ceiling fan 1200mm sweep, 5 star rating BLDC motor including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from ceiling rose/ connector to fan all as specified and as directed.
33Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and as directed.
34Supply and fix LED tube light fittings 1X20 Watts, extruded aluminium housing and diffuser, free illumination for continuous operationall as specified and as directed. Make: Cat No. BCLAB 20W WH LED P (cool white) ofBajaj or its equivalent in Philips/Havells/Crompton Greaves.
35Supply and fix LED tube light fittings 1X10 Watts,extruded aluminium housing and diffuser, free illumination for continuous operationall as specified and as directed. Make: Cat No. BCLSB 10WH LED P (cool white) ofBajaj or its equivalent in Philips/Havells/Crompton Greaves.
36Supply and fix Surface mounted square LED down lighter 15W with Aluminium die-cast body,finished with drop down PC diffuser to deliver low glare illumination with optimised heat sink for efficient heat dessipation all as specified and as directed. Make: Cat No. BGSLO SLEEK SURFACE 15W WH SQ ( white) ofBajaj or its equivalent in Philips/Havells/Crompton Greaves.
37Supply and fix Surface mounted square 1 X 1 LED luminaire 18W with white powder coated CRCA housing, seamless front frame with flat white high transmission acrylic cover all as specified and as directed. Make: Cat No. BZSSQL18W LED WH i ( white) ofBajaj or its equivalent in Philips/Havells/Crompton Greaves.
38Supply and fix Bulk head luminaire with opal diffuser with energy saving new generation 10 Watt LED bulb, IP 65 protection all as specified and as directed. Make: Cat No. BIBWP 10W LED (white) of Bajaj or its equivalent in Philips/Havells/Crompton Greaves.
39Supply and fix Multi purpose low high bay application type LED fitting, 80 watts, with IP-65 protection all as specified and as directed. Make: Cat No. BGPPR 80W LED VX ofBajaj or its in Philips/Havells/Crompton Greaves.
40Supply and fix TV socket including GI Box and modular inner and outer plate complete all as specified and as directed. Make Crabtree Cat No. ACVKTOW001 or equivalent of Legrand/ Anchor/Standard/ HPL
41Supply and fix Telephone socket RJ-11 including GI Box and modular inner and outer plate complete all as specified and as directed. Make Crabtree Cat No. ACVKRTW111 or equivalent of Legrand/ Anchor/Standard/ HPL
42Supply and fix Cable tray for telephone wire using PVC rigid cable tray from grond floor junction box to all individual qtr of size A- 60x60 all as specified and as directed. Make: Cat No. WWA6060SG of L&T or its equivalent in Havells/Anchor/Standard
43Supply and fix Cable tray for TV co axial wire using PVC rigid cable tray from grond floor junction box to all individual qtr of size B- 100x80 complete all as specified and as directed. Make: Cat No. WWB10080SG of L&T or its equivalent in Havells/Anchor/Standard
44Supply and fix VTPN 12 way distribution board, with 200 Amps rated bus bar, double door flush type as per IS 8623with IP-54 protection, isolated neutral bars, door earthing, suitable for 4P MCCB of rating 250 A as incomer (frame F2)complete with all accessories all as specified and directed. Make: Indo Asian Cat No 812048 or equivalent in Havells/Anchor/Standard/L&T
45Supply and fix VTPN 8 way distribution board, with 200 Amps bus bar,double door flush type,with IP-54 protection, isolated neutral bars, door earthing, suitable for 4P MCCB of rating 125 A as incomer (frame F1)complete with all accessories all as specified and directed. Make: Indo Asian Cat No 812042 or equivalent in Havells/Anchor/Standard/L&T
46Supply and fix VTPN 4 way distribution board, with 200 Amps rated bus bar, double door flush type,with IP-54 protection, isolated neutral bars, door earthing, suitable for 4P MCCB of rating 125 A as incomer (frame F1)complete with all accessories all as specified and directed. Make: Indo Asian Cat No 812045 or equivalent in Havells/Anchor/Standard/L&T
47Supply and fix distribution board, 4 waywith 200 Amps rated bus bar, double door flush type,with IP-54 protection, isolated neutral bars, door earthing, suitable for SPN/DP MCB/RCBO as incomer and SP MCB as outgoing complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No.811824or equivalent in Havells/Anchor/Standard/L&T
48Supply and fix distribution board, 8 way with 200 Amps rated bus bar, double door flush type,with IP-54 protection, isolated neutral bars, door earthing, suitable for SPN/DP MCB/RCBO as incomer and SP MCB as outgoing complete with all accessories all as specified and directed by Engineer-in Charge. Make: Indo Asian Cat No 811826 or equivalent in Havells/Anchor/Standard/L&T
49Supply and fix 12 way MCB distribution board, with 200 Amps rated bus bar, double door flush type,with IP-54 protection, isolated neutral bars, door earthing, suitable for SPN/DP MCB/RCBO as incomer and SP MCB as outgoing complete with all accessories all as specified and directed. Make: Indo Asian Cat No 811828 or equivalent in Havells/Anchor/Standard/L&T
50Supply and fix MCCB, 4 pole, adjustable thermal setting type, confirm to IEC 60947-II, F2 frame of rating 250 A, breaking capacity 36 kA complete with all accessories all as specified and directed. Make: Indo Asian/Havells/Anchor/Standard/L&T
51Supply and fix MCCB, 4 pole, adjustable thermal setting type, confirm to IEC 60947-II, F1 frame of rating 125 A, breaking capacity 25 kA complete with all accessories all as specified and directed. Make: Indo Asian Cat No 830273 or equivalent in Havells/Anchor/Standard/L&T
52Supply and fix MCCB, 4 pole, adjustable thermal setting type, confirm to IEC 60947-II, F1 frame of rating 100 A, breaking capacity 25 kA complete with all accessories all as specified and directed. Make: Indo Asian Cat No 830272 or equivalent in Havells/Anchor/Standard/L&T
53Supply and fix MCCB enclosure sheet metal, powder coated suitable for frame 1 and suitable for 4 pole MCCB with all accessories all as specified and directed. Make: Indo Asian Cat No 811985 or equivalent in Havells/Anchor/Standard/L&T
54Supply and fix MCCB enclosure sheet metal, powder coated suitable for frame 2 and suitable for 4 pole MCCB with all accessories all as specified and directed. Make: Indo Asian Cat No 811987 or equivalent in Havells/Anchor/Standard/L&T
55SEWAGE DISPOSAL
56Supplying and Laying 160mm outer dia UPVC SWR pipe Class A conforming to IS 13592, single socketed in any length with rubber ring joint connected to manholes complete as apecified and directed.
57Supply and fix LLDPE moulded septic tank for 100 Users capacity 3 chamber design with two manholes high wall thickness, salt resistance, made out of degradable plasticincluding excavation in ordinary soil, laid over 150mm thick plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate and properly haunched and fixed as per manufacturers instructions including all necessary accessories etc for 75 to 100 flushings complete as apecified and directed. Make: United or its equivalent makes as listed in list of makes here in after.
58Supply and fix Sokage wells excavation in any type of soil, foundation in PCC 1:3:6 wall of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of PCC block masonry with CM, RCC cover slab in M25 interconnecting pipes complete filled with brick batss of size 1.8 m dia 3.0m depth details as per Drawing No.TD/A/162 Sheet 1/1 complete all as specified and directed.
59HIGH SECURITY WALL
60Supply and fix Galvanized MS concertina coilof 610 mm outer dia made out of 2.60mm diaspring steel wire 230gm (2min) dipped with corrosion preventive fluid(rusilo 901)of Castrol make incl white colour , each coil having min 50 turns (circles) and an average weight not less than 8.57kg (plus or minus 5%) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with MS rod for securing incl necessary welding to MS sections etc complete all as specified and directed.
61PILE FOUNDATION (FOR BUILDING & HIGH SECURITY WALL)
62Material and Labour for Boring of cast in situ pile of 800 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed. Note:- (i) The rate shall include mobilisation,erection,dismantlingand demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii)This item shall be executed as per location marked in drg.
63Material and Labour for Boring of cast in situ pile of 700 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed. Note:- (i) The rate shall include mobilisation,erection,dismantlingand demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii)This item shall be executed as per location marked in drg.
64Material and Labour for Boring of cast in situ pile of 600 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed. Note:- (i) The rate shall include mobilisation,erection,dismantlingand demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii)This item shall be executed as per location marked in drg.
65Material and Labour for Boring of cast in situ pile of 500 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed. Note:- (i) The rate shall include mobilisation,erection,dismantlingand demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii)This item shall be executed as per location marked in drg. (iii) The quantity of boring is including 9.0M deep piles for High security wall.
66Material and Labour forReinforced cement concrete of grade RMC M-30 design mix as per IS – 456 with using 20mm graded stone aggregate in cast in situ bored pile using tremie method of any length/any sections complete all as specified and as shown on drg as in bored pile including destructive integrity test on all pile as per IS-14893,2001 part-IV. Note: (i) The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity test. (ii) The quantity is including 9.0M deep piles for High security wall.
67Material and Labour for Reinforced cement concrete of grade RMC M-30 design mix as per IS–456 using 20mm graded stone aggregate in pile caps, plinth beam/grade beams etc complete all as specified and shown on drg.complete all as specified and directed. Note: (i) Reinforcement shall be measured and paid for separately under relevantitems of this Schedule. (ii) The quantity is including for pile caps of High security wall.
68Use and waste of form work to sides of pile caps, grade beams, tie beams for fair finished flat concrete surface complete all as specified and directed.
69Material and Labour for PCC1:4:8 type D2 using 40mm graded stone aggregate for concrete layer below pile cap/grade beam andfoundation complete all as specfified and as shown in drg complete all as specified and directed.
70Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
71Providing TMT bars(CRS/HCRM/CRM) in reinforcement 5 mm dia end over up to and including 10mm dia conforming to IS-1786 as in Helical/spiral for piles cut to length, bent to shape required, and binding with 0.9mm dia MS annealed wire orwelding complete all as specified and shown on drgs complete all as specified and shown on drgs.
72Providing TMT bars (CRS/HCR/CRM) in reinforcement 5 mm dia and over up to and including 10mm dia conforming to IS-1786 as stirrups for pile caps/ grade beamscut to length, bent to shape required, and binding with mild steel wire (annealed) not less than 0.9mm dia or welding
73Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M deep or area not exceeding 10 sqm on plan and getting out in soft/loose soil for pile caps complete all as specified and as directed.
74Excavation in trenchesnot exceeding 1.5M wide and exceeding 1.5M deep and not exceeding 3.0M deep or area not exceeding 10 sqm on plan and getting out in soft/loose soil for pile caps complete all as specified and as directed.
75Excavation over area not exceeding 1.5M deep or area exceeding 10 sqm on plan and getting out in soft/loose soil for pile caps complete all as specified and as directed.
76Excavation over areaexceeding 1.5M deep and not exceeding 3.0M deep or area exceeding 10 sqm on plan and getting out in soft/loose soil for pile caps complete all as specified and as directed.
77Excavation over areaexceeding 3.0M deep and not exceeding 4.5M deep or area exceeding 10 sqm on plan and getting out in soft/loose soil for pile caps complete all as specified and as directed.
78Returning filling in and ramming in layers around pile cap , plinth beams, tie beams etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and as directed.
79Removal excavated soil to distance not exceeding 50M and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and as directed.
80Testing of piles of depth 46.00 M for building portion (Initial Load test of 500mmdia cast in situ pile for compression load, lateral load and uplift load) all as per IS 2911including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. Note: The intitial load test shall becomprising ofcompression load, lateral load and uplift load and the rate quoted shall be accordingly for these tests. Boring, concrete and steel for pile shall be measured and paid under respective item.
81Testing of piles (Routine Load test) all as per IS of 800mm diaCast in situ piles for building portion includingmobilising and removing the testing equipments from site after testing is completed all as specified and directed.
82Testing of piles (Routine Load test) all as per IS of 700mm diaCast in situ piles for building portion includingmobilising and removing the testing equipments from site after testing is completed all as specified and directed.
83Testing of piles (Routine Load test) all as per IS of 600mm diaCast in situ piles for building portion includingmobilising and removing the testing equipments from site after testing is completed all as specified and directed.
84Testing of piles (Routine Load test) all as per IS of 500mm diaCast in situ piles for building portion includingmobilising and removing the testing equipments from site after testing is completed all as specified and directed. Note for Item Nos.72 to 77: Only compression load Test shall be carried out for Routine load test.
85Testing of piles (Routine Load test) all as per IS of 500mm diaCast in situ piles for High security wall portion (9.00M deep pile) includingmobilising and removing the testing equipments from site after testing is completed all as specified and directed. Note: Only compression load Test shall be carried out for Routine load test.
86EXTERNAL WATER SUPPLY
87Supply and fix Supply and fix Cast iron air release valve with 50 mm bore and two outlets as per IS:14845. complete all as specified and directed.
88Supply, installing, testing and commissioning of electrically driven Centrifugal Pump set as per specification, motor TEFC type, 2900 rpm, 420 V, 50 Hz, 3 ph, class "F" insulation, IP 55 protection, not less than 7.5 HP, starting on suitable DOL/Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller(as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 400 LPM at 60 mtr head inclusive of suitable rated 3 ph starter as recommented by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge. Make:- Kirloskar Brothers/ equaivalent. NOTES: (i) Materal and labour for required length of suction pipe, GI heavy duty, flanged type, suitable for the suction side of pump including valve on suction sideand recommended size of foot valve with accessories complete. (ii) Materal and labour for required length of delivery pipe, GI heavy duty, flanged type, suitable for the delivery side of pump including delivery valve as per manufactures design. (iii ) Pressure gauge diaphram type up to 50 kg/sq.cm- 1 No. (d ) DOL Starter suitable for the pumpset as p[er manufacturers design- 1 No.
89Material and Labour for Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted includes all earthwork and connected items.
90Supply ,install, test and commissioning LT Panel board indoor type, factory made CPRI approved, powder coated, dust and vermin and weather proof, cubicle type, outer shell made of 2 mm thick CRCA sheet and MS angle iron erection of 50x50x6 mm frame, front operated with locking arrangements. The bottom of outer shell contains having provision for entry for armoured cable of adequate size with glands and provision of louvers and air vent gasket for natuaral flow of air. The panel board shall have suitable busbar chamber having sufficient space to pass throughUG cablesand compartments for each control gearand metering devices. Providing busbar for phase and neutraland shall be insulated with colour-coded heat shrinkable sleeves and shall be mounted on suitable size "F" class insulators made on hygroscopic , non-combustible , track resistant, high-strength FRP/SMC/DMC material at an interval ofnot more than 300 mm through out the length of TPN busbar all as specified and directedcomprising of following:- (a) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 300 Amps for phases and 150 Amps for Neutral.
91Incoming:- (a) MCCB 4 pole, 200 Amps, breaking capacity 36 KA- 01 No. Metering Unit:- (a) R Y B Indications (LED Type)- 1 sets (b) Digital Multi function meter - 01 No. (c)CT"s - 200/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 4 pole, 415 Volts, 100 Amps, breaking capacity 25 KA- 04 Nos.(2 Spare) (b) MCB SPN, 230 Volts, 32 Amps, 10 KA- 02 Nos. (c) DOL Starter suitable for 5 HP Pump set- 02 Nos. (d) Single phase preventer- 02 Nos.
92EXTERNAL ELECTRIC SUPPLY
93Supply and fixing 4 Pole MCCB 500 Amp, 50 Hz, 415 V with rupturing capacity 35 KA with suitable enclousre and angle iron support of size 50 x 6 mm complete all as specified and directed. (In Existing Power house for tapping from existing Substation).
94Supply ,install, test and commission LT Panel board indoor type, factory made CPRI approved, powder coated, dust and vermin and weather proof, cubicle type, outer shell made of 2 mm thick CRCA sheet and MS angle iron erection of 50x50x6 mm frame, front operated with locking arrangements. The bottom of outer shell contains having provision for entry for armoured cable of adequate size with glands and provision of louvers and air vent gasket for natuaral flow of air. The panel board shall have suitable busbar chamber having sufficient space to pass throughUG cablesand compartments for each control gearand metering devices. Providing busbar for phase and neutraland shall be insulated with colour-coded heat shrinkable sleeves and shall be mounted on suitable size "F" class insulators made on hygroscopic , non-combustible , track resistant, high-strength FRP/SMC/DMC material at an interval ofnot more than 300 mm through out the length of TPN busbar all as specified and directed comprising of following:- (a) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 1000 Amps for phases and 500 Amps for Neutral. Incoming:- (a) MCCB 500 Amp FP 50 KA- 01 (Incoming) Metering Unit:- (a) R Y B Indications (LED Type)- 1 sets (b) Digital Multi function meter - 01 No. (c)CT"s - 500/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 315 Amp FP 36 KA- 01 (Outgoing- power circuit DB) (b) MCCB 200 Amp FP 36 KA- 01 (Outgoing- Lighting DB) (c) MCCB 125 Amp FP 36 KA- 01 (Outgoing-MT Section ) (d) MCCB 100 Amp FP 36 KA- 01 (Outgoing-spare)
95All as per Item No. 84above but with the following fixtures:-( Standby Panel) (a) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating500 Amps for phases and 250 Amps for Neutral. Incoming:- (a)Change over switch, 415 V, four pole 200 Amp. - 01 (Incoming) (b)MCCB 200 Amp FP 36 KA- 01 (Incoming) Metering Unit:- (a) R Y B Indications (LED Type)- 1 sets (b) Digital Multi function meter - 01 No. (c)CT"s - 200/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 63 Amp FP 25 KA- 05 (Outgoing, 1 for lift, 1 for terrace pump,1 for Eseential light DB, 1 for street light pole light, 1 spare)
96Supply and fix energy saving and environmental friendly long life LED Street light fitting 1 x 72 watts made out of pressure die cast housing with high efficiency LEDs as lighting sourceand lens embedded PC cover having top opening separate driver compartmentwith IP 66 protection including control gear/control drive and box complete all as specified and directed. Make: Havells/Bajaj/Wipro/Shakti
97Supply and fix energy saving and environmental friendly long life LED Street light fitting 1 x 36 watts made out of pressure die cast housing with high efficiency LEDs as lighting sourceand lens embedded PC cover having top opening separate driver compartmentwith IP 65 protection including control gear/control drive and box complete all as specified and directed. Make: Havells/Bajaj/Wipro/Shakti
98Supply and fix Supply and spread LT Rubber mat of 1 mtr x 2 mtr x 19 mmcomplete all as specified and directed.
99Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No MCB SP 6 Amps for operating the streetlight fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. Make: Cat Part No KF 5000 B of Make Hensel or quivalant as approved by GE.
100DIESEL GENERATOR SET
101Supply and install Static silent Disel Engine with accoustic enclosure, capable of delivering 50 Kw (62.5 KVA), water cooled, 415 volts (AC three phase, 4 wire system of supply) , frequency 50 Hz, at power factor 0.80 minimum. The DG set shall consists of a diesel engine coupled to a matching the alternator through flexible coupling and mounted on a common based frameand complete with control panel standardized by the manufacturer, fuel tank with mounting arrangements and with standard fuel pipes for inlet, outlet and return inlet oil arrangements, exhaust pipe, silencer and asbestrose rope protection completye and shall be suitable for conditions prevailed at Kochi. (Designed capacity of Diesel engine and alternator shall be worked out by considering all derating factors prevailed at Fort Kochi) The foundation of Gen Set shall be as specified by the manufacturer and shall be mounted on a suitable Channel frame structure with anti-vibration pads and including all technical features to comply with latest CPCB guidelines and comprising of followings:-
102(i) DIESEL ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, four stroke, confirming to ISO3046/BS5514, water cooled, natuarally turbo charged, capable of giving adequate BHP to drive alternator capable of delivering 50 Kw(62.5 KVA) at outdoor atmospheric conditions at Kochi (Considering all derating factors prevailed in the area). Batteries 12/24 Volts and desired ampere hours (as per manufacturers recommendations), electric battery start, complete with fly wheel and all standard fittings and fixtures as per manufacturer and including suitable panel with techo meter, lub oil temperature, pressure gauge and frequenvy meters. The engine shall have self starter, dynamo, FIP, oil pump, fuel electric control panel with mechanical governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc. , recommented capacity of fuel tank and first filling of fuel and lub oil and other consumables etc. (ii) ALTERNATOR: Brushless AC alternator, 3 phase, 415 Volts, 4 wire rated for output of 50 Kw (62.5 KVA) minimum power factort 0.80, 1500 RPM, IP 23 ptotection class enclosure, insulation class "H", salient pole, revolving field, single bearing, automatic voltage regulator coupled through flexible coupling with and match the above engine. (iii) BASE PLATE:- Made of structural steel as per manufacturers recommended design/specifications.
103(iv) ACOUSTIC ENCLOSURE:- Sheet metal fabricated canopy type, silent enclosure, manufactured on CNC machines as per CPCB norms and shall be powder coated. The enclosure shall be designed for reducing the sound level to 75 DB at a distance of 1 mtr at 75% load under field condition and 70 db at 3 M from Gen Set when DG set is working at full load along with testing conformance, labeling certification etc. as laid down in GSR No. 371(E) dt 17 May 2002. (i) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.50 M space should be available all around the set and height of plinth shall not be less than 0.50 M. (ii) Standard Diesel Engine tank of adequate capacity for running the Gen Set continuously for 12 hours including standard pvc pipes from tank to FIP, overflow pipe from FIP to tank.
104(v) MISCELLANEOUS:- Tool kit, Operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee cards, test certificate of Engine and alternator etc. shall be provided as per manufacturer standard practice. (vi) AMF CONTROL PANEL:- Three phase 62.5 KVA DG AMF with 100 Amps auto change over panel as per standard made cubicle type and 2 mm thick MS CRCA Sheet, front opening type, protection class IP-55, duly powder coated, copper bus bar with coloured PVC sleeves and of suitable rating for four poles mounted on suitable porcelain insulators at recommended intervals, with all standard switch gear and protection, internal wiring with adequate size and rating PVC insulated multistranded copper conductor cables etc all as specified and directed as per manufacturer.
105LIFT
106Supply, installing, testing and commissioning of passenger lift having capacity 544Kgs/ 8 passengers as per IS 14665, electrically operated with simplex full collective/selective control suitable for operation with or without attendent to serve G+4 floors, ie ground floor and 4 upper floors with rated speed of 1.50 mtr/second with and including electric power operating doors, automatic electric levelling device, automatic rescue devices, a screen of infrared beam acting on a curtain across the door entrance, stqainless steel enclosures as specified including all stell works in machine room such as machine beam, bearing plate with beam and necessary buffer support, channeland ladder in pit. (a) Stops and openings:-5 stops/ 5 openings on the same side. (b) The internal dimension of the lift car should be suitable size for the specified load and in accordance with the statutory requirements. (c) The inside car measurement shall be based on lift well dimensions as per IS 14665, shown on drawings forming part of the Contract.
107Supply, installing, testing and commissioning of passenger lift having capacity 884Kgs/13 passengers as per IS 14665, electrically operated with simplex full collective/selective control suitable for operation with or without attendent to serve G+4 floors, ie ground floor and 4 upper floors with rated speed of 1.50 mtr/second with and including electric power operating doors, automatic electric levelling device, automatic rescue devices, a screen of infrared beam acting on a curtain across the door entrance, stqainless steel enclosures as specified including all stell works in machine room such as machine beam, bearing plate with beam and necessary buffer support, channeland ladder in pit. (a) Stops and openings:-5 stops/ 5 openings on the same side. (b) Thje integral dimension of the lift car should be suitable size for the specified load and in accordance with the statutory requirements. (c) The inside car measurement shall be based on lift well dimensions as per IS 14665, shown on drawings forming part of the Contract.
108Note for item 91 to 92 Each lift shall be complete with following accessories & fittings. (a) Double button with 7 segmental dispaly at all floors (b) Car opening panel with micro stroke push button with 7 segment digital car position indicator, car direction indicator (c) Fireman"s swich provided at main lobby. (d) Battery-operated alarm bell and emergency lift with battery. (e) Voiced synthesizer (f) Car chime (g) Provision of cross flow rectangular (low-noise/mild air flow) fan 01 No approve make (h) S&F decorative spotlight (i) provn of emergency intercom system (car machine room control system ) (j) overload function,constant indication/buzzer (k) 5/15 A power socket and light point at every floor level in the hoistway (l) MS ladder (m) 3 phase power supply & earthing from machine room to all equipments (n) Multi-beam full-length infrared door sensor minimum of 32 (o) emergency landing device ELD (ARD) (p) Extra cores in traveling cable for customer smoke detectors (q) Background music speakers. (r) Lift shall be conforming to IS 14665.
109AVIATION OBSTRUCTION LIGHT
110Supply and fix aviation obstruction light LED type including necessary cabling all as specified and directed. Make Bajaj Cat No. BGAV 302 LED or equivalent in Philips/Wipro/Crompton /Havells
111Supply and fix6 Amps SPN MCB 230 volt complete all as specified and directed.
112COOLING APPLIANCES
113Supply and install water cooler electrically driven, stainless steel body, IEE raiting 3.5 minimum single phase withstorage capacity of 120 litre and nominal cooling capacity 60 Litre per hour complete all as specified and as directed. Make: Samsung/Haeir/Godrej/Voltas/Blue star or Equivalent as approved.
114Supply and install 2 TR Capacity split type AC with inverter compressor technology, 5 Star or equivalent with latest ISEER rating, inverter type R-32 refrigerent, anti dust filter, active carbon filter, anti microbial filter, anti viral filter and heavy duty cooling Hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality (Inverter type) including provision of suitable bracket fixing arrangement, required copper pipe and insulation as per site requirement, all as specified and directed by the Engineer-in-Charge. Make:- Blue star/LG/Voltas/Daikin/Hitachi.
115Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 5 Star rated direct cool inverter, single doorall as specified and directed by the Engineer-in-Charge. Make:- Samsung/Haeir/Godrej/Voltas/Equivalent.
116Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed. Make: V guard/Shakti or Equivalent as approved.
117Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. Make: V guard/Shakti or Equivalent as approved.
118FIRE FIGHTING
119Supply and fix Cast iron air release valve with 50 mm bore and two outlets as per IS:14845 complete all as specified and directed.
120Supply, installation, testing & commissioningof networkable 2 Loop Micro processor based 2 wire fault tolerant loop with optional redunadant network module ,each loop shall have the cpability of connecting 126 devices.The fire alarm control panel shall have built in degarde mode function.The panel should have inbuilt TCP/IP communication for Panel Program and Remote Monitoring option through LAN or WAN communication.The panel shall be able to givelocation ofall fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 2000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 8x40 characters LCD display with resolution of 256 X 112 pixels, and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Should have protection caregory of IP30. Also the panel should have the option to operate in manned and unmanned mode.The Panel shall have 99 Zones with Individual LED Indicators or with in the Loop mimic driver for 96 LED indicators.The panel shall have a built in power supply and battery charger along withmaintenance free 24 AH, 2x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required.and as per specifications and Duly Approved byEN54/LPCB/VDS/FM complete all as specified and directed.
121Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM all as specified and directed by Engr-in-Charge. Make: SIEMENS/NOTIFIER/BOSCH
122Supply ,install, test and commission LT Panel board indoor type, factory made CPRI approved, powder coated, dust and vermin and weather proof, cubicle type, outer shell made of 2 mm thick CRCA sheet and MS angle iron erection of 50x50x6 mm frame, front operated with locking arrangements. The bottom of outer shell contains having provision for entry for armoured cable of adequate size with glands and provision of louvers and air vent gasket for natuaral flow of air. The panel board shall have suitable busbar chamber having sufficient space to pass throughUG cablesand compartments for each control gearand metering devices. Providing busbar for phase and neutraland shall be insulated with colour-coded heat shrinkable sleeves and shall be mounted on suitable size "F" class insulators made on hygroscopic , non-combustible , track resistant, high-strength FRP/SMC/DMC material at an interval ofnot more than 300 mm through out the length of TPN busbar. all as specified and directed comprising of following:- (a) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 300 Amps for phases and 150 Amps for Neutral.
123Incoming:- MCCB 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No. Metering Unit:- (a) R Y B Indications (LED Type)- 1 sets (b) Digital Multi function meter - 01 No. (c)CT"s - 200/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 4 pole, 415 Volts, 160 Amps, breaking capacity 36 KA- 02 No. (b) MCB TPN 32 Amps "D" curve 10 KA- 4 Nos (c) Provision for Star delta starter - 01 No (d) Provision for DOL starter - 02 Nos (e)Provision for Contactors suitable for pumping set - 03 Nos ( Main Fire fighting pump, Jockey pump and terrace pump)
124Supply, installation testing and commissioning of XLPE insulated electric cable with copper coductor of size 1.5 sq.mm, 2 core suitable for working voltage 1100 Volts to IS:7098 and drawn into PVC coduit pipe 20 mm. all as specified and directed.
125Supply, installation testing and commissioning of XLPE insulated electric cable with copper coductor of size 2.5 sq.mm, 2 core suitable for working voltage 1100 Volts to IS:7098 and drawn into PVC coduit pipe 20 mm. all as specified and directed.
126Supply and fix wall mounted LED emergency down signage luminaire Light up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours complete all as specified and directed. Make: Cat No LSSR5W of Crompton Greaves or equivalent to Bajaj/Havells.
127Supply and fix wall mounted LED emergency exit signage luminaire Light up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours complete all as specified and directed. Make: Cat No LSSR5W of Crompton Greaves or equivalent to Bajaj/Havells.
128Material and Labour for Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items.
129Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized ironsteel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1(using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completionall as specified and as directed. ( LT panels-2 nos x 2=4 nos, Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 , RCC cover slab, GI funnel with 15 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
130Supply and fix Supply and fixing fire extinguisher Mechnical foam extinguisher (stored pressure type)of capacity 9 litre complete all as specified and directed.
131Supply and fix fire extinguisher CO2 (light weight squeeze grip type) (IS:15683) of capacity 3 Kg complete with installation brackets complete all as specified and directed.
132Supply and fix fire bucket (dry sand) as per IS:2546 complete all as specified and directed.
133COMPREHENSIVE MAINTENANCE OF LIFT
134Comprehensive maintenance and servicing of Electrically Operated Passenger Lift of Capacity 544 KGs, 08 Passangers with a speed of 1.5 M/Sec control AC VVVF to travel ground to Four upper floors with G+4 with simplex collective, selective control with AC variable voltage with or without attendant, battery operated emergency light, Car lights and alarm bell, fireman switch, switch to panel centre opening horizontally sliding automatic doors for car and landing entrance, etc complete including ARD including repairs/replacement of defectiveand unserviceable parts during contract period, attending to breakdown as and when intimated includingnecessary periodical safty checking and testing of lifts as mentioned in relevant code of practice / IE for the safe and efficient performance for First year after expiry of defects liability period complete all asdirected.
135All as per item No.113 here in before but for Second year after expiry of defects liability period.
136All as per item No.113 here in before but for Third year after expiry of defects liability period.
137Comprehensive maintenance and servicing of Electrically Operated Passenger Lift of Capacity 884 KGs, 13 Passangers with a speed of 1.5 M/Sec control AC VVVF to travel ground to Four upper floors with G+4 with simplex collective, selective control with AC variable voltage with or without attendant, battery operated emergency light, Car lights and alarm bell, fireman switch, switch to panel centre opening horizontally sliding automatic doors for car and landing entrance, etc complete including ARD including repairs/replacement of defectiveand unserviceable parts during contract period, attending to breakdown as and when intimated includingnecessary periodical safty checking and testing of lifts as mentioned in relevant code of practice / IE for the safe and efficient performance for First year after expiry of defects liability period complete all asdirected.
138All as per item No.116 here in before but for Second year after expiry of defects liability period.
139All as per item No. 116 here in before but for Third year after expiry of defects liability period.
140SOLAR PLANT
141Design, supply, installation, testing and commissioningof Solar PV Modules capable of generating 30 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules shall be as per approved design parameters, with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 320/325 Wp with minimum 72 cells & efficiency not less than 17-19 %, conforming to IEC 61215, IEC 61730, IEC 61701 complete comprising with the following:- (a) Material and labour for Module Mounting structure (MMS) fabricted from pre-coated aluminium section of suitable size with specifiedtilt angle according to site requirement & Optimum angle to achieveMax benefit of solar energy and suitable to withstand 175 Kmph wind speed all as per approved design parameters and to match with the existing site conditions. Necessary roof treatment to avoid any sepage in future shall be carried out. (b) Supply, laying & TestingofDC cable minimum size 1x 4/1x6 sqmm multi stranded copper conductor. (c) Supply, installation test andcommissioningof junction boxes / SMBs for 30 KWp AC outputall as per approved design & layout plan. (d) Supply, laying & Testingof DC cable 2 runs minimum size 1x 4/1x6 sqmm(DC side) 4x25 sqmm copper unarmoured (for ac side)including suitablesizeof cable lugs, male & female MC4 connectors & joints etc. (e) Supply,installation, test andcommissioningofGrid tie Solar Power conditioning unit / inverter of minimum capacity 30 KW(DC to AC 415 V in Three phase system) (f) Material and labour for Earthing forLightning protection for SPV modules etcas per IE rule, MNRE guide line& BIS all as per approved plan.
142(g) Supply and fixingaluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV moduleslightning protection upto interconnection between Roof top LA to Ground Earthing system. Note (i) :- (a) Before quoting the bid, Contractor or his authorised Engineer / consultant must visit the proposed site to study the site condition. (b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including requiredqty to Accepting Officer for approval. Note (ii):- (a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years. (b) All Mechanical, Electrical works shall be carried out as per relevant BIS/IS/equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time. (c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 30 KW (AC) all as mentioned above and which is not mentioned or included in this Schedule A , but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to includedfor the same. (d) Contractor shall provide adequate Spares requiredfor minimumperiod of 1 year maintenance including DC & AC items under scope of work. (e) Remote monitoring system for solar system shall be provided with mobile network SIM and data pack recharge for minimum one year.
143SURVEY AND SOIL INVESTIGATION
144Soil Investigation including making necessary arrangement mobilisation and demobilisationfor equipment tools and plant personnel etc required for soil investigation and their removal after satifaction completion of work in land including slushy areas etc complete comprising of following:- (a) Boring 150mm dia through all types of soil to a depth of 75 metre (06 Nos bore holes)below the ground level collecting samples and conducting necessary field tests for pile foundation of dia 800mm, 700mm, 600mm and 500mm. (b) Conducting all necessary laboratory tests on samples and submission ofreports with suggestion on type of suitable foundation system. Note : (i) Soil Investigation can be carried out only after demolition of existing P-1 building as catered in the relevant schedule. (ii) For details refer Particular specification clause Nos.40 to 40.5.
145DEMOLITION OF BUILDING & CREDIT OF DEMOLISHED BUILDING MATERIALS
146Demolition of building shall comprise of following:- (a) Demolition of P-1 building including foundation, connected celectrical, water supply systems, fittings and fixtures and removing debris out side MD land and clearing site and complete complete all as specified and as directed. (b) Credit for the materials retrieved from demolition. NOTE: (i) The Credit amount for the material obtained from demolished building will be of minimum (Minus) (-) Rs. 19,55,000.00. The amount entered shall not be less than(-) Rs. 19,55,000.00. (ii) Bidder shall insert their amount for demolition and credit amount as composite ratein Green field under Col-6. (iii) The bidder is advised to visit the site of work to ascertain the condition and quantity of items before quoting the tender.