| 1 | Earthwork in excavation of foundation trenches in hard soil with initial lead and lift except sheet rock and boulders (requiring blasting)including dressing and levelling the bed upto the required depth ad depositing the excavated materials away from the site with all leads and lifts. T and p shoring and shuttering if required etc. complete as directed by egineer-in-charege. |
| 2 | Supplying and filling in foundation and ditches with sand well watered and rammed in layers not exceeding 23 cm in depth with all lead and lift including cost, conveyance, loading and unloading , royalties and taxes of all materials and cost of all labour, sundries. T & P required for the work etc complete in all respect as per direction of Engineer incharge. |
| 3 | Providing & laying plain cement concrete 1:3:6 ( 1 cement 3 coarse and 6 graded stone aggregate fo 40 mm nominal size) in foundation and pinth including cost of hoisting, lowering laying concrete, ramming , |
| 4 | Providing & laying plain cement concrete 1:3:6 ( 1 cement 3 coarse and 6 graded stone aggregate fo 40 mm nominal size) in foundation and pinth including cost of hoisting, lowering laying concrete, ramming , |
| 5 | Plain Cement Concrete (1:4:8) using 40 mm size H.G. metal ( crusser brocken ) well rammed including cost, conveyance, royalty taxes of all metarials, etc completed as per the direction of the Engineer-in-charge. |
| 6 | Providing , lifting hoisting laying Reinforced cement concrete of M20 grade in column footings , as per approved designs and drawings having a munimumcompressive strength ( in work test) 200 Kg./ Square cm in 15cm. Cubes at 28 days after mixing and tests conducted in accordance with I.S. 416 using 12mm to 20 mm size black hard crusher broken granite stone ships of approved quality from approved quarry washed and cleaned (20mm size not to exceeds 25%) to be mixed in concrete mixture with ordinary protland cement (OPC) including noisting, lowering lying an dcompacting concreteby susing vibrators, watering and curing for 28 days centering and shuttering and finishing the exposed surface smooth proving grooves or beads wherever necessary including cost conveyance, loading and unloading royalitiesand taxes of all materials and cost of all labours sunones , T & P required fo rthe work ect complete in all respect excluding cost and conveyance of HYSD/MS steel and binding wires , and labour charges for straightaining, cutting , bending etc of M.S. rods of for steel and binding. |
| 7 | Ground FloorColumn base |
| 8 | Plinth Beam |
| 9 | Column up to Roof level |
| 10 | Window Sill |
| 11 | Chajja |
| 12 | Roof Beam |
| 13 | Roof Slab |
| 14 | Stair case |
| 15 | 1st floor Column up to Roof level |
| 16 | Window Sill |
| 17 | Chajja |
| 18 | Roof Beam |
| 19 | Roof Slab |
| 20 | Stair case |
| 21 | 2nd floor Column up to Roof level |
| 22 | Chajja |
| 23 | Roof Beam |
| 24 | Roof Slab |
| 25 | Fly Ash brick masonayin cemnet mortar of (1.6) with portland slag cement, watering and curing etc. including cost, conveyance, loading and unloading, royalities and taxes of all materials and cost of all lbaour sundriesT& P required for the works etc complete in all respect asdirectedby the Enginner -in-charge.in F and P |
| 26 | Ground floor SUPERSTRUCTUR |
| 27 | 1st floor |
| 28 | 2nd floor |
| 29 | Providing HYSD reinforcement for RCC works including bending,binding & placing in positionas perDrawingincludingcost, conveyance of all materials, alllabourand T&P etc complete. |
| 30 | Foundation & Plinth |
| 31 | Ground floor |
| 32 | 1st floor |
| 33 | 2nd floor |
| 34 | Providing and laying12 mm cement plaster 1.6 to out sideon surface after cleaning the surface taking out point including cost of all materials labour cuting taxes etc complete as per instruction fo architect/ Engineer incharge |
| 35 | Ground floor |
| 36 | 1st Floor |
| 37 | 2nd Floor |
| 38 | Providing and laying16 mm cement plaster 1.6 to out sideon surface after cleaning the surface taking out point including cost of all materials labour cuting taxes etc complete as per instruction fo architect/ Engineer incharge |
| 39 | Ground floor |
| 40 | 1st Floor |
| 41 | 2nd floor |
| 42 | Providing and laying6 mm cement plaster 1.4 to out sideon surface after cleaning the surface taking out point including cost of all materials labour cuting taxes etc complete as per instruction fo architect/ Engineer incharge |
| 43 | Ground floor |
| 44 | 1st floor |
| 45 | 2nd floor |
| 46 | Finishign walls with water proofing weather coat of approved shade on new work 2 coats to give an even shade inclduing cost of brushes and putty inclduing cost of paint for out side. |
| 47 | Ground floor |
| 48 | 1st Floor |
| 49 | 2nd floor |
| 50 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade excluding cost of distemper.inclduing cost of brushes and putty inclduing cost of paint( per one Sq. Mtr)(for inside) |
| 51 | Ground Floor |
| 52 | 1st Floor |
| 53 | 2nd floor |
| 54 | Providing and painting two coats of synthetic enamel paints over a coat of primer to steel work including sand papering, scaffolding , cost of conveyance, taxes of all materials. T & P labour required to complete the work as per design/ drawing & instruction of Architect/ Engineer-in- charge. |
| 55 | Ground Floor |
| 56 | 1st floor |
| 57 | 2nd floor |
| 58 | Providng and fixing of FRP (PVC)door including frame and all necessary accessories such as tower blot, handles, hingesetc complete in all respects. |
| 59 | Doors /Window frame made out of M.S. angle I.S.A 40mm x 40 mm x 6 mm with integrated frill of M.S. Flat 6mm x 18 mm @ 100 mm c/c spacing horizontally. The frame with be embedded to the wall with M.S. clamps including shutter made out of 18 gauge sheet propertywelded/ embedded with ISA 25mm x 25 mm x 6 mm & provided with 25 mm x 6 mm flatplacing diagonally completed in all respect as per the diraction of EIC.The item is inclusive of all fitting fixures such as handle tower bolt stay, hinges , knob , screws, etc with all materials labour T & P etc. |
| 60 | Ground Floor |
| 61 | 1st floor |
| 62 | 2nd floor |
| 63 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railling using 50mm dia of 32mm x 32mm x 2mm @ 0.90mtr C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm 3 rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T & P etc required for the work complete in all respect. Data for 3.26 sqm. |
| 64 | Fixing Vitrified tiles (600 x 600) in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete including cost of precast tiles. |
| 65 | Ground Floor |
| 66 | 1st Floor |
| 67 | Fixing Vitrified tiles (600 x 600) in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete including cost of precast tiles. |
| 68 | Ground Floor |
| 69 | 1st Floor |
| 70 | Fixing Ceramic tiles (300 mmx 300mm)in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete including cost of precast tiles. |
| 71 | Ground Floor |
| 72 | 1st Floor |
| 73 | Kadapa tiles in Kitchen |
| 74 | Ground Floor STAIR CASE Chequered Tile |
| 75 | 1st Floor STAIR CASE Chequered Tile |
| 76 | Fixing Ceramic tiles (300 mmx 300mm)in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete including cost of precast tiles. |
| 77 | Gound Floor |
| 78 | Ist Floor |
| 79 | Fixing of Granite tilesfor kitchen platformon 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment of match the shades of the tiles including rubbing and polishing complete excluding cost of pre-cast Granite . |
| 80 | Supplying fitting and fixing of windows (sliding type) made up of aluminium section 9778 as window frame section no 4095,4096 and 9777,3994 as shutter frame with 5 mm thick black glass as pannel fitted with rubber beadinhg including locking arrangemen including all fiting including cost of all materials,labour T and P etc.required for the wok all complete. |
| 81 | Plinth Protection |
| 82 | Earth work in excavation of foundation trenches in hardsoil with initial lead and lift except sheet rock and boulders (requiring blasting) including dressing and leveling the bed upto the required depth and depositing the excavated materials away form the site with all leads and lifts. T & P shoring and shuttering if required etc. complete as directed by engineer- in charge. |
| 83 | Supplying and filling in foundation and ditches with sand well watered and rammed in layers not exceeding 23 cm in depth with all lead and lift including cost, conveyance, loading and unloading , royalties and taxes of all materials and cost of all labour, sundries. T & P required for the work etc complete in all respect as per direction of Engineer incharge. |
| 84 | Providing & laying plain cement concrete 1:3:6 ( 1 cement 3 coarse and 6 graded stone aggregate fo 40 mm nominal size) in foundation and pinth including cost of hoisting, lowering laying concrete, ramming , watering and curing etc. complete to required levels laid in layers not exceeding 15cm thick including cost. Conveyance, loading and unloading, royalties and taxes all materials and cost of all labours, sundnes, T & P required for the work complete including dewatering if required as epr instruciton of Engineer-in- charge. |
| 85 | Providing & laying plain cement concrete 1:2:4)( 1 cement 2 coarse and 4 graded stone aggregate fo 10TO20 mm nominal size) in foundation and pinth including cost of hoisting, lowering laying concrete, ramming , watering and curing etc. complete to required levels laid in layers not exceeding 15cm thick including cost. Conveyance, loading and unloading, royalties and taxes all materials and cost of all labours, sundnes, T & P required for the work complete including dewatering if required as epr instruciton of Engineer-in- charge. |
| 86 | SEPTIC TANK |
| 87 | Earth work in excavation of foundation trenches in hardsoil with initial lead and lift except sheet rock and boulders (requiring blasting) including dressing and leveling the bed upto the required depth and depositing the excavated materials away form the site with all leads and lifts. T & P shoring and shuttering if required etc. complete as directed by engineer- in charge. |
| 88 | Supplying and filling in foundation and ditches with sand well watered and rammed in layers not exceeding 23 cm in depth with all lead and lift including cost, conveyance, loading and unloading , royalties and taxes of all materials and cost of all labour, sundries. T & P required for the work etc complete in all respect as per direction of Engineer incharge. |
| 89 | Plain Cement Concrete (1:4:8) using 40 mm size H.G. metal ( crusser brocken ) well rammed including cost, conveyance, royalty taxes of all metarials, etc completed as per the direction of the Engineer-in-charge. |
| 90 | Providing , lifting hoisting laying Reinforced cement concrete of M20 grade in column footings , as per approved designs and drawings having a munimumcompressive strength ( in work test) 200 Kg./ Square cm in 15cm. Cubes at 28 days after mixing and tests conducted in accordance with I.S. 416 using 12mm to 20 mm size black hard crusher broken granite stone ships of approved quality from approved quarry washed and cleaned (20mm size not to exceeds 25%) to be mixed in concrete mixture with ordinary protland cement (OPC) including noisting, lowering lying an dcompacting concreteby susing vibrators, watering and curing for 28 days centering and shuttering and finishing the exposed surface smooth proving grooves or beads wherever necessary including cost conveyance, loading and unloading royalitiesand taxes of all materials and cost of all labours sunones , T & P required fo rthe work ect complete in all respect excluding cost and conveyance of HYSD/MS steel and binding wires , and labour charges for straightaining, cutting , bending etc of M.S. rods of for steel and binding. |
| 91 | Buffle wall |
| 92 | Roof slab |
| 93 | Providing HYSD reinforcement for RCC works including bending,binding & placing in positionas perDrawingincludingcost, conveyance of all materials, alllabourand T&P etc complete. |
| 94 | Fly Ash brick masonayin cemnet mortar of (1.6) with portland slag cement, watering and curing etc. including cost, conveyance, loading and unloading, royalities and taxes of all materials and cost of all lbaour sundriesT& P required for the works etc complete in all respect asdirectedby the Enginner -in-charge. |
| 95 | Providing and laying12 mm cement plaster 1.6 to out sideon surface after cleaning the surface taking out point including cost of all materials labour cuting taxes etc complete as per instruction fo architect/ Engineer incharge |
| 96 | Providing and laying12 mm cement plaster 1.6 to out sideon surface after cleaning the surface taking out point including cost of all materials labour cuting taxes etc complete as per instruction fo architect/ Engineer incharge |
| 97 | 25mm thicks as fiooring c.c (1:2:4) using 12mm sizE C.B.H.G |
| 98 | supplying all materials,labour &T&P for construction of inspection chamber attached to septic tank at inlet as per P.H specification and design all complite one NOS |
| 99 | supplying,fitting and fixing swarage pipe at inlet&outlet junction |
| 100 | P.H Supplying , fitting , fixing of water closet of CERA make 2073 Orissa Pan(Cello) of size 510 x 400 mm or equivalent of Parryware/ Hindware , duly embedded in cement concrete(1:3:6) using 12mm size b.h.g chips all complete with materials , albour and T& P etc. |
| 101 | Supplying , fitting , fixing of porcelein wash hand basin of size 450mm x 350 mm of CERA make,catalogue no Canon 1012 Wash Basin of Equivalent of Parryware/ Hindware with rog bolts, CI brackets, hole for pillar cock with cast iron/ M.S. brackets painted while including cutting holes in wall and making good to the damages etc. all complete with materials , labour andT& P etc. |
| 102 | Supply , fitting , fixing of ( 500 x 450 mm) bevelled edge mirror of superior glass mounted on 6 mmthk A.C. sheet or ply-wood sheet and fixed to wooden plugs with cromium plated brass screws and washers etc. all complete with materials , labour and T & P etc. |
| 103 | Supply, fitting , fixing of Stain Less Steel Kitchen sink with cast iron/ M.S brackets painted while including cutting holes in walls and making good to the damages etc. all complete wit materials labour and T& P etc. |
| 104 | Providing and fixing PVC soil waste and vent pipes |
| 105 | (i) 110 mm dia . |
| 106 | Supplying fitting , fixing of PVC floor traps of the following norminal diameter of outlet of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm including cutting holes in walls and making good to the damages etc. all complete with materials, labour and T& P etc. |
| 107 | (i) Providing and fixing PVC plain bend of required degree 100 mm |
| 108 | Providingand fixing PVC single equal plain junction of required degeewith access door, insertion rubber washer 3mm thick, bolts and nuts complete . |
| 109 | (i) 1000x100x100mm |
| 110 | roviding and fixing door piece, insertion rubber washer 3mm thick , bolts & nuts complete .(i) 110mm |
| 111 | 110 mm |
| 112 | Providing & fixing PVC terminal guard (i) 110 mm |
| 113 | Supplying, fitting, fixing to walls, ceiling and floor upplasticized PVC pipes conforming to I.S. 4985 of class IV ( 10 kg/ cm 2) th efollowing nominal diameter with fittings and clamps includings testing all complete with materials labour and T & P etc. |
| 114 | a) 15mm dia nominal bore |
| 115 | b) 20mm dia nominal bore |
| 116 | c) 25 mm dia nominal bore |
| 117 | d) 32 mm dia nominal bore |
| 118 | e) 40 mm dia nominal bore. |
| 119 | Providing and fioxing brass bib cock of approved quality . |
| 120 | 15 mm nominalbore short body |
| 121 | 15mm nominal bore long body |
| 122 | Providing and fixing brass stop cock with wall flush of approvedquality . |
| 123 | 15 mm nominal bore. |
| 124 | Providing and fixing gun metal gate valve with C.I. wheel of approved qualioty ( screwed end) |
| 125 | (i) 25 mm dia Nominal bore |
| 126 | (ii) 32 mm dia Nominal bore |
| 127 | Supplying fiting , fixing of S.W.Gully trap Grade-A completewith cast iron grating, brick masonry chamber( 250 mm x 250 mm) with R.C.C cover slab as per P.H. specificaiton and design all complete with materials labour and T & P etc. (Excluding cost of gully trap and grating) |
| 128 | Supply all labour , materials andT & P and laying to level and slope and jointing with cement mortar(1:1) for PVC pipes . (Grade-A) of the following diametersas per specification al complete (excluding earth work in trenches)(data for 30 mtr.) (per mtr) S.W. Pipe 150mm dia. |
| 129 | Providing and placing on terrance (at all floor levels) per liter polyethylene water storage tank ISI:12701 marked capacite indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for intel, outlet and overflow pipes but without fittings and the base support for tank (sintex, Electroplast, star Lots of equivalent having valid ISI license) |
| 130 | Provision for Hand Wash |
| 131 | Earthwork in excavation of foundation trenches in hard soil with initial lead and lift except sheet rock and boulders (requiring blasting)including dressing and levelling the bed upto the required depth ad depositing the excavated materials away from the site with all leads and lifts. T and p shoring and shuttering if required etc. complete as directed by egineer-in-charege. |
| 132 | Supplying and filling in foundation and ditches with sand well watered and rammed in layers not exceeding 23 cm in depth with all lead and lift including cost, conveyance, loading and unloading , royalties and taxes of all materials and cost of all labour, sundries. T & P required for the work etc complete in all respect as per direction of Engineer incharge. |
| 133 | Plain Cement Concrete (1:4:8) using 40 mm size H.G. metal ( crusser brocken ) well rammed including cost, conveyance, royalty taxes of all metarials, etc completed as per the direction of the Engineer-in-charge. |
| 134 | Fly Ash brick masonayin cemnet mortar of (1.6) with portland slag cement, watering and curing etc. including cost, conveyance, loading and unloading, royalities and taxes of all materials and cost of all lbaour sundriesT& P required for the works etc complete in all respect asdirectedby the Enginner -in-charge.in F and P |
| 135 | Providing , lifting hoisting laying Reinforced cement concrete of M20 grade in column footings , as per approved designs and drawings having a munimumcompressive strength ( in work test) 200 Kg./ Square cm in 15cm. Cubes at 28 days after mixing and tests conducted in accordance with I.S. 416 using 12mm to 20 mm size black hard crusher broken granite stone ships of approved quality from approved quarry washed and cleaned (20mm size not to exceeds 25%) to be mixed in concrete mixture with ordinary protland cement (OPC) including noisting, lowering lying an dcompacting concreteby susing vibrators, watering and curing for 28 days centering and shuttering and finishing the exposed surface smooth proving grooves or beads wherever necessary including cost conveyance, loading and unloading royalitiesand taxes of all materials and cost of all labours sunones , T & P required fo rthe work ect complete in all respect excluding cost and conveyance of HYSD/MS steel and binding wires , and labour charges for straightaining, cutting , bending etc of M.S. rods of for steel and binding. |
| 136 | Roof Slab |
| 137 | Providing HYSD reinforcement for RCC works including bending,binding & placing in positionas perDrawingincludingcost, conveyance of all materials, alllabourand T&P etc complete. |
| 138 | Providing and laying12 mm cement plaster 1.6 to out sideon surface after cleaning the surface taking out point including cost of all materials labour cuting taxes etc complete as per instruction fo architect/ Engineer incharge |
| 139 | Gound Floor |
| 140 | Fixing Ceramic tiles (300 mmx 300mm)in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete including cost of precast tiles. |
| 141 | Gound Floor |
| 142 | Provision of Taps |
| 143 | Provision of brass stop cock |
| 144 | Provision of ph fittings (Labour charges for pipe line connecting from water source tap incluing fittings) |
| 145 | Supplying all materials, labour and T & P forconstruction of inspection chamber as per P.H. specification and design all ocmplete ( ( The details specification will be obtained from engineer in charge during execution of work)) |
| 146 | Supplying, fitting fixing or constructing of 1.20 mtr dia x 2.55 mtr.Deepsoak-way pit with dry brick walling up to2.10mtr. Height and brick work with cment mortar(1:6) for 0.45mtr height of wall at top, cement plaste(1:3)inside and ouside, inside filled with dry brick khoa of 50mm to 100 mm size to a height of 2.00 mtr form bottom. covered by means of 40mm thick R.C.C perforated slat 50 mm thick RCC. Well cover inpieces fitted with iron rings including earth work in excavation and refiling of cavity around the pit etc all complete as per approved design and drawing ( ( The details specification will be obtained from engineer in charge during execution of work)) |
| 147 | Recessed wiring to Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 Amp, 250 Volt piano type swich ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.0 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked as earth wire including all accesories and connection as per direction of engineer in charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 148 | a) Light point |
| 149 | Long |
| 150 | Midium |
| 151 | b) Celling fan point |
| 152 | Long |
| 153 | Medium |
| 154 | c) Exhaust fan point |
| 155 | c) 5 A plug point |
| 156 | Recessed wiring for 15 / 16 Amp socket outlet with 2 X 4.00 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 Amp, 250 Volt piano type swich ISI marked, Phenolic laminated sheet of suitable size ISI marked MS box and earthing point with 1 X 2.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor for loop earthing etc. as required, as per direction of engineer in charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 157 | Recessed wiring to Sub-Main in 2 X 2.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC heavy duty flexible conduit with 1.60 mm thick, along with 1 X 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor as earth wire as required as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 158 | Recessed wiring to Sub-Main in 2 X 4.00 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 25 mm dia non-metallic PVC heavy duty flexible conduit with 1.60 mm thick, along with 1 X 2.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor as earth wire as required as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 159 | Recessed wiring to Sub-Main in 2 X 10 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 25 mm dia non-metallic PVC heavy duty flexible conduit with 1.60 mm thick, along with 1 X 4 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor as earth wire as required as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 160 | Earthing with G.I earth pipe 3 mtr long 40 mm dia ISI mark including accessories and providing machinary enclosure with cover plate having locking arrengement and watering pipe etc. with charcol and salt etc. |
| 161 | Providing and fixing G.I tape 20 mm X 3 mm thick on parapet of surface of wall for lightning conductor complete as per direction of Engineer-in-charge. |
| 162 | Providing and fixing Copper tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 163 | Supply , fixing and fitting of 11 watt LED light ( make Philips / Bajaj/ Cromption or Equivalent) |
| 164 | Supply & fixing of single spot light of 18 watts complete with 1 no. 18 watt of approved make complete with all necessary fixing materials including termination & labour ( make:- Philips/ Bajaj/ Crompton of Equivalent) |
| 165 | Supply, installation, Testting and commissioni of celling fan 1200 mm sweep 230/250 volts , 50 Hz, complete with suitable, clamp, downrod, blades, connections with 1.5 sq. mm PVC insulated copper conductor cable et as required and fan hook made of 16mm M.S. rod in R.C.C roof complete with all accessories. |
| 166 | Providing and fixing Single Pole MCB with sheet steel enclosure, distribution board on surface / recess complete with tinned copper bus bar , neutral bus bar, earth bar, din bar, detachable gland plate inter connection phospate and powder painted including earthing etc. as per direction of Engineer-in-charge. |
| 167 | Supply, installation, Testting and commissioni of Exhaust Fan 300 mm sweep 230/250 volts , 50 Hz, complete with suitable, clamp, downrod, blades, connections with 1.5 sq. mm PVC insulated copper conductor cable et as requiredcomplete with all accessories. |
| 168 | Supply, installation, testing and commissoning of 63amp TPN main switch of following capacity (IS 13940 part-3/19930 on existing surface / wall mounting and complete with HRC fuse links inter connections, earthing etc as per direction of Engineer-in-charge.9SEIMENS/HPL/ANCHOR/L&T/HAVELS/C&S/RK) |