| 1 | Laying of 11KV Line |
| 2 | ST Pole 9 mtrST 410 SP33 |
| 3 | GI V cross arm with top bracket including clamp |
| 4 | GI channel X-arm including clamps and braces |
| 5 | ACSR Dog conductor |
| 6 | 11KV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 7 | 11KV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 8 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 9 | 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type |
| 10 | Galvanised Nuts & Bolts |
| 11 | Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/Pole |
| 12 | Anti-Climbing Device with Clamps |
| 13 | Danger Plates with Clamps |
| 14 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip (25x3)mm |
| 15 | Red Oxide |
| 16 | Aluminium Paint |
| 17 | Supply, Fabrication,Erection, Testing and commissioning of 25KVA Distribution substation |
| 18 | 11/0.433KV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) and with LV cable box having detachable Aluminium Gland plate |
| 19 | 9 mtr long Pole ST-410, SP33 |
| 20 | Gapless Surge Arrestor, 9kV, 10kA, LA with polymer housing, Station type |
| 21 | 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type |
| 22 | 11kV Horn Gap Fuse set 3-phase, 200 Amp |
| 23 | 95sqmmcable 1.1kv grade, PVC insulated stranded conductor FRLS type |
| 24 | Al. Thimble 95mm2 |
| 25 | 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 26 | 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 27 | GI Channel/Angle/Flat ofdifferent sizes including clamps |
| 28 | Galvanised Nuts & Bolts |
| 29 | Earthing of substation - Excavation of earthing pit of dia 650mm & depth 3000mm, installation ofEarthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm x 3mm for connection of transformer body, GO set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover |
| 30 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 31 | LT distribution box for 25KVA DTR with MCCB for incomer & SFU\"s for outgoing circuits |
| 32 | Prodigy Meter |
| 33 | Danger Plates with clamps |
| 34 | G.I Barbed Wire for anti climbing |
| 35 | Cement bottoming 1:2:4 mix as per REC standards .5cum/Pole |
| 36 | Painting of Poles Red oxide |
| 37 | Painting of Poles Aluminium Paint |
| 38 | Supply, Fabrication,Erection, Testing and commissioning of LT cable |
| 39 | Al. conductor PVC Armoured 3 1/2 core cable 50 sqmm 1.1kv grade, Armoured XLPE insulated stranded conductor FRLS type |
| 40 | Al. Thimble 50sqmm |
| 41 | Al. bus bar 50x10 mm |
| 42 | Galvanised Nuts & Bolts |