Repairs To Roof Treatment False Ceiling Ac Galvalume Sheet Sunken Floors Wooden Aluminium Joinery And Connected Items For Otm And Offrs Accn Area Under Age Br I Chandipur, chandipur-Odisha

Military Engineer Services-MES has published Repairs To Roof Treatment False Ceiling Ac Galvalume Sheet Sunken Floors Wooden Aluminium Joinery And Connected Items For Otm And Offrs Accn Area Under Age Br I Chandipur. Submission Date for this Tender is 19-07-2022. False Celing Tenders in chandipur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

32620466
Corrigendum : Repairs To Roof Treatment False Ceiling Ac Galvalume Sheet Sunken Floors Wooden Aluminium Joinery And Connected Items For Otm And Offrs Accn Area Under Age Br I Chandipur
Open Tender
Indian
Odisha
chandipur
19-07-2022

Tender Details

Repairs To Roof Treatment False Ceiling Ac Galvalume Sheet Sunken Floors Wooden Aluminium Joinery And Connected Items For Otm And Offrs Accn Area Under Age Br I Chandipur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-07-2022
2 06-Jul-2022 Corrigendum No. 01 Date 19-07-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIRS TO ROOF TREATMENT, FALSE CEILING, AC/ GALVALUME SHEET, SUNKEN FLOORS, WOODEN/ ALUMINIUM JOINERY AND CONNECTED ITEMS FOR OTM & OFFRS ACCN AREA UNDERAGE B/R I CHANDIPUR
Sl. No. Item Description
1NOTE (Applicable for all items) :- The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
2Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
3S & F 0.50 mm thick Pre- painted galvalume aluminium zinc coating GI based corrugated steel colour sheet having tensile strength of 550 Mpa as in roof covering with self tapping screws complete all as specified and directed.
4S & F 0.50 mm thick Pre- painted galvalume aluminium zinc coating GI based plain colour sheet having tensile strength of 550 Mpa as in roof covering with self tapping screws complete all as specified and directed.
5S & F 6 mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc complete all as specified and directed.
6M & L for asbestos cement two piece adjustable plain wing ridge 6 mm thick fixed with L or J type or cranked hook bolts complete all as specified and directed.
7Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
8S & F power coated anodised aluminium snap grid frame work for false ceiling of grid size 605 mm x 605 mm fixed to walls with rawl plugs and screws and hungto roof members with 6 mm dia GI wire (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long with and including 4 mm thick non asbestos fibre cement building designerboard fixed or laid / inserted to timber / GI / aluminium frame work and applying two coats of distemper oil emulsion complete all as specified and directed.
9Taking down Chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
10Taking down Chowkats or frames exc. 1.50 Sqm but n.exc 4.00 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
11Taking down shutter of any description n. exc 1 sqm each. complete all as specified and directed.
12Taking down shutter of any description but exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed.
13M & L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
14M & L for Factory made of 35 mm thick glazed and skeleton shutters made of 2nd class hard wood, open rebated and prepared to receive glass gauge edges of framing plain chamfered or rounded, fitted with cut and mitredbeads for securing glass etcshutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed .
15M & L for Factory made of 30 mm thick glazed and skeleton shutters made of 2nd class hard wood, open rebated and prepared to receive glass gauge edges of framing plain chamfered or rounded, fitted with cut and mitredbeads for securing glass etcfor window, ventilator shutters, etc. as specified in SSR Part I, Section 8 clause 8.24(b) and fitted to chowkhat complete all as specified and directed .
16M & L for Factory made of 30 mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
17M & L for preparation of new or previously untreated surface of wood of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamelled paint over one coat of pink primer complete all as specified and directed.
18Taking down and refixing shutter after repair of any description n. exc 1 Sqm eachin same opening complete all as specified and as directed.
19Taking down and refixing shutter after repair of any description exc 1 Sqm but n. exc 2 Sqm eachin same opening complete all as specified and as directed.
20S & F solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain coloured PVC sheet reinforced with MS Square tube complete all as specified and directed.
21S&FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as per manufacturer"s instruction.
22S & F for butt hinges medium weight cold rolled mild steel of 100 mm size. complete all as specified and directed .
23S & F for butt hinges medium weight cold rolled mild steel of 75 mm size. complete all as specified and directed .
24S & F for Stainless steel butt hinges of 75 mm size. complete all as specified and directed .
25S & F for 150 mm extruded Aluminium aloy handles, febricated type anodised complete all as specified and directed .
26S & F for 100 mm extruded Aluminium aloy handles, febricated type anodised complete all as specified and directed.
27S & F for 150 mm sizealuminium anodised barrel tower boltof extruded sectioncomplete all as specified and directed.
28S & F for 100 mm sizealuminium anodised barrel tower boltof extruded sectioncomplete all as specified and directed.
29S & F for 250 mm Sliding door bolt aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
30S & F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
31S & F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed.
32Hacking out old broken glass (any thickness, size, quality ordescription) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
33S & F for 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
34S & F for 3 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
35S & F in repairs for butt hinges medium weight cold rolled mild steel of 100 mm size. complete all as specified and directed .
36S & F in repairs for butt hinges medium weight cold rolled mild steel of 75 mm size. complete all as specified and directed .
37M & L for 2nd class hardwood Plain fillets sectional area n. exc 3 Sq CM each square or rectangular in section, clean sawn, secured with nails orbrads complete all as specified and directed .
38M & L for 2nd class hardwood beads, straight (any Size) for glazed or gauged joinery, recewed including mitred etc after removing beads from old shutters exc 3 but n exc 6 sq CM each square or rectangular in section, clean sawn, secured with nails orbrads complete all as specified and directed .
39S & F in repairs for 150 mm extruded Aluminium aloy handles, febricated type anodised complete all as specified and directed .
40S & F in repairs for 100 mm extruded Aluminium aloy handles, febricated type anodised complete all as specified and directed .
41S & F in repairs for 150 mm sizealuminium anodised barrel tower boltof extruded sectioncomplete all as specified and directed .
42S & F in repairs for 100 mm sizealuminium anodised barrel tower boltof extruded sectioncomplete all as specified and directed .
43S & F in repairs for 250 mm Sliding door bolt aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
44M & L for flat iron for hold fast of doors / windows confirming to FE - 290 GdeE-165complete all as specified and directed. (Flat Iron 250 x 30 x 3 mm thick @ 0.707 Kg / RM).
45M & L for preparing surfaces of wood and wood based materials of any description and girth, backs of chowkats, etc, area tarred exc 0.1 sq. m but n exc 0.5 sq. m each and tarred with coat tar / black paint complete all specified and directed.
46Cutting holes for inserting hold fasts in Brick wallsbuilt in cement mortar and making good disturbed portion in PCC (1: 2 :4)type B1 or in cement mortar (1:3) as required, depth of embeddedportion exceeding half brick but not exceeding one brick for full brick walls, complete all as specified and as directed .
47S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length 150 mm fixed in floor complete all as specified and as directed .
48S & F in repairs Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length 150 mm fixed in floor complete all as specified and as directed .
49S & F for 300 mm, ordinary rat tail rod pattern Helical door springs including roller and roller plate complete all as specified and directed.
50S & F in repairs for 300 mm, ordinary rat tail rod pattern Helical door springs including roller and roller plate complete all as specified and directed.
51S & F Mortice lock, vertical type, size 100 mm, long 4 levers with handles as in repairs complete all as specified and directed.
52S & F in repair door closer hydraulically regulated of cast iron body, designation No.3 universal typesuitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete allas specified and as directed.
53S & F for 150 mm long aluminiumplate type II hook & eye for window shutter complete allas specified and as directed.
54S & F in repairs 150 mm long aluminiumplate type II hook & eye for window shutter complete allas specified and as directed.
55Demolition of cement concreteof any description in any position not otherwise specifically provided for complete all as specified and directed.
56Roughening surfaces of old concrete floors/slabs by pickling, sweepingcleaning and washing down with water to remove dust, brushing neat cement slurry with 3.0Kg of cement per sqm complete all as specified and directed.
57M & L for providing average 25 mm thick PCC 1 : 2 : 4 type B-0 (using 12.5 mm graded stone aggregate) as in padding concrete for getting proper slope of roof / covering etc as complete all as specified and directed.
58M & L for rendering 10 mm thick average in cement mortar (1:4) over roof surfaces mixed with WPC as per manufacturer’sinstructions, finished fair without using extra cement complete all as specified and directed. (NOTE: WPC shall be measured and paid separately)
59Preparation of surface and applying two coats of hot bitumen blown VG-30 to concrete surfaces at the rate of 1.5 kg. per sq. m per coat complete all as specified & directed.
60M & L for roof treatment using APP based polymeric membrane, minimum weighing 3 kg / sqm and minimum 3 mm thick, reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application with side over lap75 mm and end lap minimum 100 mm and sealing over lap and joints as per manufacturer"sinstructions complete all as specified and directed.
61M & L for one coat of aluminium paint 0.30 liters / sqm above the APPmembrane complete all as specified and directed.
62Taking down cement plaster any description and the like on brick or stone walls, etc including raking out joints,hacking for key, scrubbing down with water etc. complete all as specified and directed.
63M & L for15 mm thick rendering in CM 1:4 on brick or concrete surfacesfinished even and smooth with integral water proofing compound (IWPC Measured and paid seperately) on wall complete all as specified and directed.
64Preparation of new plaster surface of wall and applying two coats ofPremium Acrylic Smooth exterior paint with Silicone additives of required shade@ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqmcomplete all as specified and directed.
65Supply only integral liquid water proofing compound
66Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to tore (measured overall as fixed along the centre line over fittings and accessories).
67S & F for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
68S & F for 110 mm PVC (SWR) bends any radius complete all as specified and directed.
69S & F for 110 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
70Dismantling water tanks of any type of capacityexc 250 but n.exc 500 liters and removing to store complete all as specified and directed.
71S & F Rotational moulded polyethylene water storage tanks of 500 liters capacity (cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I .
72Dismantling water tanks of any type of capacityexc 500 liters but n. exc 1000 ltrs and removing to store complete all as specified and directed.
73S & F Rotational moulded polyethylene water storage tanks of 1000 liters capacity (cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I .
74Disconnecting existing 500 Liter tanks, setting aside (or lowering if required)from mouths of circulating pipes, etc. and hoisting if required reconnecting andre-fixing in position complete all as specified and directed.
75Disconnecting existing 1000 Liter tanks, setting aside (or lowering if required)from mouths of circulating pipes, etc. and hoisting if required reconnecting andre-fixing in position complete all as specified and directed.
76S & F of Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to20 mm bore pipe complete all as specified and directed.
77S & F of Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to15 mm bore pipe complete all as specified and directed.
78Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
79Taking up or down steel tubing 20mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
80S & F GI pipe medium grade 15 mm dia bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
81S & F GI pipe medium grade 20 mm dia bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
82Fixing only, ‘Medium grade’ galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors of 15 mm bore complete all as specified and directed.
83Fixing only, ‘Medium grade’ galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors of 20 mm bore complete all as specified and directed.
84Taking down aluminium anodised shutters for doors, windows, ventilator partition wall and refixing after necessary repairs etc complete all as directed. Note : Aluminium section, glass, prelaminated particle board panels and floor hinges etc will be measured and paid separately.
85Fixing only aluminium chowkats / frame for door, windows and ventilator complete all as specified and directed.
86S & F Aluminium beads with rubber gasket 20 mm width complete all as specified and directed.
87S & F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specifiedand directed.
88S & F for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, handles2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed.
89S & F for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, hingesetc. complete all as specified and directed.
90S& F 12 mm Prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations fixed with screws to timber frame work complete all as specified and directed.
91Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
92S& F 19 mm Prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations fixed with screw to timber frame work including second class hardwood beading all around complete all as specified and directed.
93S& F Sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
94S& F Sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane including hacking out old broken glass complete all as specified and directed.
95S& F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
96S& F Anodised Aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC-15 of approved design / pattern, with approved standard section and fixed to the existing window frame with CP Brass / Stainless Steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and as directed.
97Taking down care fully steel rolling shutters of any size complete gear operated / mannual operated complete all as specified and directed.
98S & F for Steel rolling shutters, with out ball bearing thickness of lath 1.25 mm as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
99Refixing of steel rolling shutters including necessary repairs /replacement of spare parts if required and cleaning dust, greasing etc including making good the disturb surface of brick / RCC wall in existing complete all as specified and directed.
100M & L for preparation of new steel surfaces over 10 cm in width or girth and applying two coats of aluminium paint over a coat of aluminium red oxide primer complete all as specified and directed.
101M & L for preparation of old steel surfaces over 10 cm in width or girth and applying one coat of aluminium paintcomplete all as specified and directed.
102Supply only 75 mm wide, 1.25 mm thick MS profile for rolling shutter, riveted / welded were necessary including taking out old unserviceable profile one coat of red oxide primer and painting one coat complete all as specified and directed.
103S & F in repairs ball bearing for rolling shutter complete all as specified and directed.
104S & F in repairs Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
105Supply only MS spring 40 CM long for rolling shutter for counter balancing the weight of rolling shutter complete all as specified and directed.
106S & F in repairs gear box with handle complete all as specified and directed.
107S & F in repairs 0.80 mm Mild steel, plain, black sheet in wall cladding, steel gates and similar work (like rolling shutter cover hood), cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
108Treatment of sunken floor slab comprises the following specificatons and all as specified :- (i) M & L for cleaning the sunken/ lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush,chisel out any mortar sticking to the surface and brooming completely. 40 mm thick avg PCC 1:2:4 type B0 using 12.5 mm graded aggregate as in padding concrete to achieve proper slope including 50 mm PVC pipe and cutting holes in bricks or RCCwall for spour. (ii) Rendering of uneven surface with 6mm thick CM 1:4 mixed with integral water proofing compound @3 % by wt of cement consumed. Fill it with water and check dampness and seepage, where dampness /seepage is noticed, nozzles shall be fixed and grouting carried out ( WPC shall be measued and paid separately). (iii) All junction points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M & L for applying two coats of polymer modified cementious water proof coating as per manufacturer"s instructionto bottomand vertical sides up to finished floor level +100 mm ht. The thickness of two layer shall be 1 mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface portion all as specified and directed. (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer"s speciication incl rounding of corners and junctions sloping towards spout (WPC shall be measured and paid separately). Note: Test the water proofed area (ponding test) by filling water for at least 72 hrs and tested for leakage, seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals.Cost of testing is included in the rates quoted) (vii)All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anti-corrosive paint( Black Japan) (viii) Two Nos of 50mm bore GI medium grade 600mm long spout shall be provided through external wall to drain out accumulated water.