| 1 | EARTH WORK |
| 2 | Earth work in excavation of foundation trenches in ordinary soil except sheetrockandboulders(requiringblasting)includingdressingand leveling the bed upto the required depth and depositing the excavated materials away form the site with all leads and lifts. T & P shoring and shuttering if required etc. complete as directed by engineer- in charge. |
| 3 | SAND FILLING |
| 4 | Supplying and filling in foundation and ditches with sand well watered and rammed in layers not exceeding 23 cm in depth with all lead and lift including cost, conveyance, loading and unloading , royalties and taxes of all materials and cost of all labour, sundries. T & P required for the work etc complete in all respect as per direction of Engineer incharge. |
| 5 | Supplying and filling in foundation and ditches with sand well watered and rammed in layers not exceeding 23 cm in depth with all lead and lift including cost, conveyance, loading and unloading , royalties and taxes of all materials and cost of all labour, sundries. T & P required for the work etc complete in all respect as per direction of Engineer incharge. |
| 6 | CONCRETE WORK P.C.C (1:3:6) |
| 7 | Providing & laying plain cement concrete 1:3:6 ( 1 cement 3 coarse and 6 gradedstoneaggregatefo40 mm nominalsize) infoundationand pinthincludingcostofhoisting,loweringlayingconcrete,ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15cm thick including cost. Conveyance, loading and unloading,royaltiesandtaxesallmaterialsandcostofalllabours, sundnes, T & P required for the work complete including dewatering if required as epr instruciton of Engineer-in- charge. |
| 8 | CONCRETE WORK P.C.C (1:4:8) |
| 9 | Providing & laying plain cement concrete 1:4:8 ( 1 cement 4 coarse and 8 gradedstoneaggregatefo40 mm nominalsize) infoundationand pinthincludingcostofhoisting,loweringlayingconcrete,ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15cm thick including cost. Conveyance, loading and unloading,royaltiesandtaxesallmaterialsandcostofalllabours, sundnes, T & P required for the work complete including dewatering if required as epr instruciton of Engineer-in- charge. |
| 10 | R.C.C. WORK |
| 11 | i. Providing , lifting hoisting laying Reinforced cement concrete of M20 grade in column footings , as per approved designs and drawings having a munimumcompressive strength ( in work test) 200 Kg./ Square cm in 15cm. Cubes at 28 days after mixing and tests conducted in accordance withI.S.416using12mmto20mmsizeblackhardcrusherbroken granite stone ships of approved quality from approved quarry washed and cleaned (20mm size notto exceeds 25%) to be mixed in concrete mixture with ordinary protland cement (OPC) including noisting, lowering lying an dcompacting concreteby susing vibrators, watering andcuringfor28dayscenteringandshutteringandfinishingthe exposed surface smooth proving grooves or beads wherever necessary including costconveyance, loading and unloading royalitiesand taxes of all materials and cost of all labours sunones , T & P required fo rthe workectcompleteinallrespectexcludingcostandconveyanceof HYSD/MS steel and binding wires , and labour charges for straightaining, cutting , bending etc of M.S. rods of for steel and binding |
| 12 | Column Footing |
| 13 | column upto pinth |
| 14 | Plinth beam |
| 15 | REINFORCEMENT |
| 16 | Cold twistedsteelreinforcemtnforRCCworkincluding cutting bendingstragntening and binding with 18swg black annealed wire and placing in posting complete. |
| 17 | Fly Ash brick masonry (1:6) cement mortar |
| 18 | Flyashbrickmasonay incemnetmortarof(1.6)with portland slag cement, watering and curing etc. including cost,conveyance,loadingandunloading,royalitiesand taxes of all materials and cost of all lbaour sundriesT& P requiredfortheworksetccompleteinallrespectas directedby the Enginner -in-charge. |
| 19 | 12MM CP(1:6) in plinth wall |
| 20 | (B)GROUND FLOOR |
| 21 | RCC. WORK |
| 22 | i.Providing,lifting, hoistinglayingReinforcedcement concrete of M20grade in column footings s per approved designsanddrawingshavingaminimumcompressive strength ( in work test) 200 kg/Square cm. in 15 cm cubes at 28 days afterr mixing and tests conducted in accordance with I.S. 416 using 12 mm to 20 mm size black hard crusher brokengrantie stonechipsofapprovedqualityfrom approved quarry washed and cleaned (20 mm size not to exceeds25%)tobemixedinconcrete mixurewith ordinaryportlandcement(OPC) includin ghosting, lowering, lying and compacting concrete by using vibrators,wateringandcuringfor28 dayscenteringand shuttering and finishing the xposed surface mooth providing grooves of beads wherever necessary including cost.conveyance,loadingandunloading,royaliiesand teaxes of all materials and cost of all labours , sundries , T &P,requiredfortheworketc.completeinallrespect excludingcostandconveyanceofHYSD/Mssteel and binding wires and labour charges for straihtaining, cutting, bending etc. of M.S rods of for steel and binding wires and lying the grils and placing in poper postion. |
| 23 | Column |
| 24 | Lintel Band |
| 25 | Roof beam |
| 26 | Chhajja |
| 27 | Roof Slab |
| 28 | Staircase |
| 29 | REINFORCEMENT |
| 30 | Cold twistedsteelreinforcementforRCCwork including cutting bending straihtening and binding with 18swg black annealed wire and placing in position complete |
| 31 | BRICK WORK IN SUPER STRUCTURE |
| 32 | Brick work with Fly ash Brick in CM(1:6) in Foundaiton & Plinth ( Per one Cum) |
| 33 | 250 mm th brick v. all |
| 34 | 115 mm thick brick wall with 1:4 cement mortar |
| 35 | Providingandlayingcementplasteronsurfaceafter cleaning the surface taking out pointincluding costof all materials labour cuting taxes etc complete as per instruction fo architect/ Engineer incharge |
| 36 | 12 mm cement plaster 1.6 to out side surface |
| 37 | 16mm cement plaster 1.6 over brick work to inside walls. |
| 38 | 6mm cp 1:4 over concrete surface |
| 39 | Wall painting with plastic emulsion paint for one coat with any approved paint. |
| 40 | Priming one coat with any approved primer including cost of material & labour. |
| 41 | Weather CoatWall painting 2 coats with Weather Coat of approved shade on new work to give an even shade exculding cost of paint (For 10 Sqm.) |
| 42 | Priming one coat with any approved primer including cost of material & labour. |
| 43 | 2.5 cm A.S. flooring with C.C.(1:2:4) including cement punning using 12mm size cbhg chips per sqm. |
| 44 | Fixing tiles in dados skrting on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tile. |
| 45 | 2.5 cm A.S. flooring with C.C.(1:2:4) including cement punning using 12mm size cbhg chips per sqm. |
| 46 | (MS Doors/ Widndows) |
| 47 | ProvidngfittingandfixingofM.S.Door/windowframe withintegrated grillshutterasper thefollowingdesign and specificaiton. |
| 48 | Fitting&fixingofdoor&windowinclusiveofallfitting fixuressuchashandletowerboltstay,hinges,knob, screws, etc with all materials labour T & P etc. |
| 49 | Providingandpaintingtwocoatsofsyntheticenamel paints over a coat of primer to steel work including sand papering,scaffolding,costofconveyance,taxesofall materials. T & P labour required to complete the work as per design/ drawing & instruction of Architect/ Engineer-in- charge. |
| 50 | Providingandfixing6mmthk.Glasstoventilatorand staricasewindow with Allumium angleframe and grill of size 18mm x 6 mm flat including all materials labourT & Petc. |
| 51 | f. Providing and fixing staircase railing of M.S. square bar (32 mmx32 mm Size)as balustrade& 50mmdia M.S. pipes as handrail including cost of all materials labour etc as per insturction fo engineer incharge. |
| 52 | Fixingchequred tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete excluding cost of precast TILES. |
| 53 | Fixing of Granite floorfor kitchen platform |
| 54 | (C) FIRST FLOOR |
| 55 | i.Providing,lifting, hoisting laying Reinforcedcement concrete of M20grade in column footingss per approved designsanddrawingshavingaminimumcompressive strength ( in work test) 200 kg/Square cm. in 15 cm cubes at 28 days afterr mixing and tests conducted in accordance with I.S. 416 using 12 mm to 20 mm size black hard crusher brokengrantie stonechipsofapprovedqualityfrom approved quarry washed and cleaned (20 mm size not to exceeds 25%) to be mixed in concrete mixure with ordinary portlandcement(OPC)includinghosting,lowering,lying andcompactingconcretebyusingvibrators,watering andcuring for 28days centering and shuttering and finishing thexposed surfacemoothprovidinggroovesof beadswherevernecessaryincludingcost.conveyance, loading and unloading , royaliies and teaxes of all materials and costof all labours , sundries , T &P, required for the worketc.completeinallrespectexcludingcostand conveyanceofHYSD/Mssteel andbindingwiresand labourchargesforstraihtaining,cutting,bendingetc.ofM.S rods of for steel and binding wires and lying the grils and placing in poper postion. |
| 56 | Column |
| 57 | Lintel Band |
| 58 | Roof beam |
| 59 | Chhajja |
| 60 | Roof Slab |
| 61 | Staicase |
| 62 | REINFORCEMENT |
| 63 | ColdtwistedsteelreinforcementforRCCworkincluding cutting bending straihtening and binding with 18swg black annealed wire and placing in position complete |
| 64 | Brick work with Fly ash Brick in CM(1:6) in Foundaiton & Plinth ( Per one Cum) |
| 65 | 250 mm th brick v. all with CM(1:6) |
| 66 | 115 mm thick brick wall with 1:4 cement mortar |
| 67 | 12 mm cement plaster 1.6 to out side surface |
| 68 | 16mm cement plaster 1.6 over brick work to inside walls. |
| 69 | 6mm cp 1:4 over concrete surface |
| 70 | FLOORING |
| 71 | AS FLOORING |
| 72 | (MSDoors/ Widndows) |
| 73 | Providng fittingand fixing of M.S.Door & window frame withintegrated grillshutterasperthefollowingdesign and specificaiton. |
| 74 | Fittingfixing of doors windows inclusive of all fitting fixures such as handle tower bolt stay, hinges , knob , screws, etc with all materials labour T & P etc. |
| 75 | Providingandfixing6mmthk.Glasstoventilatorand staricasewindow with M.S angleframeand grillof size 18mm x 6 mm flat including all materials labourT & P etc. |
| 76 | PAINTING |
| 77 | Weather CoatWall painting 2 coats with Weather Coat of approved shade on new work to give an even shade exculding cost of paint (For 10 Sqm.) |
| 78 | Priming one coat with any approved primer including cost of material & labour. |
| 79 | Wall painting with plastic emulsion paint for one coat with any approved paint. |
| 80 | Priming one coat with any approved primer including cost of material & labour. |
| 81 | b.Providing and paintingtwo coats of synthetic enamel paints over a coat of primer to steel work including sand papering,scaffolding,costofconveyance,taxesofall materials. T & P labour required to complete the work as per design/ drawing & instruction of Architect/ Engineer-in- charge. |
| 82 | Fixing tiles in floor dados skrting on 25mm thick bed of cement mortar1:1(1cement:1sand)jointedwithneatcement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tile. |
| 83 | (C) MUMTY FLOOR |
| 84 | RCC. WORK |
| 85 | i.Providing,lifting, hoistinglayingReinforcedcement concrete of M20grade in column footings s per approved designsanddrawingshavingaminimumcompressive strength ( in work test) 200 kg/Square cm. in 15 cm cubes at 28 days afterr mixing and tests conducted in accordance with I.S. 416 using 12 mm to 20 mm size black hard crusher brokengrantie stonechipsofapprovedqualityfrom approved quarry washed and cleaned (20 mm size not to exceeds 25%) to be mixed in concrete mixure with ordinary portlandcement(OPC)includinghosting,lowering,lying andcompactingconcretebyusingvibrators,watering andcuringfor28days centering andshuttering and finishing the xposed surface moothproviding grooves of beadswherevernecessaryincludingcost.conveyance, loading and unloading , royaliies and teaxes of all materials and costof all labours , sundries , T &P, required for the worketc.completeinallrespectexcludingcostand conveyanceofHYSD/Mssteel andbindingwiresand labourchargesforstraihtaining,cutting,bendingetc.ofM.S rods of for steel and binding wires and lying the grils and placing in poper postion. |
| 86 | Roof Slab |
| 87 | REINFORCEMENT |
| 88 | Cold twistedsteel reinforcementfor RCC work including cutting bending straihtening and binding with 18swg black annealed wire and placing in position complete |
| 89 | BRICK WORK IN SUPER STRUCTURE |
| 90 | Brick work with Fly ash Brick in CM(1:6) in Foundaiton & Plinth ( Per one Cum) |
| 91 | 250 mm th brick v. all |
| 92 | FINISHING |
| 93 | Providingandlayingcement plasteronsurfaceafter cleaning the surface taking outpointincluding costof all materials labour cuting taxes etc complete as perinstruction fo architect/ Engineer incharge |
| 94 | 12 mm cement plaster 1.6 to out side surface |
| 95 | 16mm cement plaster 1.6 over brick work to inside walls. |
| 96 | 16mm cement plaster 1.6 over brick work to inside walls. |
| 97 | FLOORING |
| 98 | Providing MS Doors/ Widndows) |
| 99 | Providng fitting and fixing of M.S.Door & window frame withintegrated grillshutterasper thefollowingdesign and specificaiton. |
| 100 | Fittingfixingofdoorsgrillsinclusiveofallfittingfixures such as handle tower bolt stay, hinges , knob , screws, etc with all materials labour T & P etc. |
| 101 | PAINTING |
| 102 | Weather CoatWall painting 2 coats with Weather Coat of approved shade on new work to give an even shade exculding cost of paint (For 10 Sqm.) |
| 103 | Priming one coat with any approved primer including cost of material & labour. |
| 104 | Wall painting with plastic emulsion paint for one coat with any approved paint. |
| 105 | Priming one coat with any approved primer including cost of material & labour. |
| 106 | b. Providing and paintingtwo coats of synthetic enamel paints over a coat of primer to steel work including sand papering,scaffolding,costofconveyance,taxesofall materials. T & P labour required to complete the work as per design/ drawing & instruction of Architect/ Engineer-in-charge. |
| 107 | SEPTICTANK:-Excavation |
| 108 | Sand filling |
| 109 | P.C.C.(1:3:6) |
| 110 | R.C.C.(1:1.5:3) up to plinth |
| 111 | Brick work (1:6) in GF. |
| 112 | Cutting ,bending ,binding,of MS rod |
| 113 | 12mm thick C.P with C M ( 1:4 ) |
| 114 | Provision of Manhole Cover |
| 115 | Providing CI Stepswith anticorrosive paint |
| 116 | TOILET FIXTURES:-Supplying , fitting , fixing of water closet of CERA/parryware/hindware/jaquarcerramake 2073 Orissa Pan(Cello) of size 510 x 400 mm or equivalent of Parryware/ Hindware , duly embedded in cement concrete(1:3:6) using 12mm size b.h.g chips all complete with materials , albour and T& P etc. |
| 117 | Providing ,fixing & fitting of EWC with PVC cover |
| 118 | PVC flushing cistern |
| 119 | 110 mm PVCCOWEL |
| 120 | 110 mm PVC TEE |
| 121 | Supplying , fitting , fixing of porcelein wash hand basin of size 450mm x 350 mm of CERA make,catalogue no Canon 1012 Wash Basin of Equivalent of Parryware/ Hindware with rog bolts, CI brackets, hole for pillar cock with cast iron/ M.S. brackets painted while including cutting holes in wall and making good to the damages etc. all complete with materials , labour andT& P etc. |
| 122 | Supply , fitting , fixing of ( 500 x 450 mm) bevelled edge mirror of superior glass mounted on 6 mmthk A.C. sheet or ply-wood sheet and fixed to wooden plugs with cromium plated brass screws and washers etc. all complete with materials , labour and T & P etc. |
| 123 | Providing and fixing PVC soil waste and vent pipes (i) 110 mm dia . |
| 124 | (ii) RWD pipe 100 mm |
| 125 | Supplying fitting , fixing of cost ( Spun) iron floor traps of the following norminal diameter of outlet of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm including cutting holes in walls and making good to the damages etc. all complete with materials, labour and T& P etc. |
| 126 | Providing and fixing PVC plain bend of required degree:- I)100MM |
| 127 | Providingand fixing PVC single equal plain junction of required degeewith access door, insertion rubber washer 3mm thick, bolts and nuts complete .(I)1000X100X100MM |
| 128 | Providingand fixingdoor, insertion rubber washer 3mm thick, bolts and nuts complete .100MM |
| 129 | Supplying, fitting, fixing to walls, ceiling and floor upplasticized PVC pipes conforming to I.S. 4985 of class IV ( 10 kg/ cm 2) th efollowing nominal diameter with fittings and clamps includings testing all complete with materials labour and T & P etc.(a)15mm nominal dia bore |
| 130 | a) 15mm dia nominal bore |
| 131 | b) 20mm dia nominal bore |
| 132 | c) 25 mm dia nominal bore |
| 133 | d) 32 mm dia nominal bore |
| 134 | e) 40 mm dia nominal bore. |
| 135 | Providing and fioxing brass bib cock of approved quality .(i) 15 mm nominalbore short body |
| 136 | (ii) 15mm nominal short body long body |
| 137 | (ii) 15mm nominal bore long body |
| 138 | Providing and fixing brass stop cock with wall flush of approvedquality .(i) 25 mm nominal bore. |
| 139 | 25 mm Nominal Bore |
| 140 | CP TOWEL BAR |
| 141 | Over head shower |
| 142 | Soap holder |
| 143 | Hand shower |
| 144 | Kitchen sink SS |
| 145 | Tube well |
| 146 | Providing and fixing gun metal gate valve with C.I. wheel of approved qualioty ( screwed end)(i) 25 mm dia Nominal bore |
| 147 | (ii) 32 mm dia Nominal bore |
| 148 | Supplying fiting , fixing of S.W.Gully trap Grade-A completewith cast iron grating, brick masonry chamber( 250 mm x 250 mm) with R.C.C cover slab as per P.H. specificaiton and design all complete with materials labour and T & P etc. (Excluding cost of gully trap and grating) |
| 149 | Supplying all materials, labour and T & P forconstruction of inspection chamber as per P.H. specification and design all ocmplete ( per each) |
| 150 | providing and placing on terrance (at all floor levels) per liter polyethylene water storage tank ISI:12701 marked 2000 ltr capacite indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for intel, outlet and overflow pipes but without fittings and the base support for tank ( sintex, Electroplast, star Lots of equivalent having valid ISI license) |
| 151 | ELECTRICALRecessed witing to Light point Each with 1.5 sqmm FR PVC insulated signle core multistand copper conducter of ISI marked with 20mm dia non-metalic PVC flexible conduct with 5 Amp, 250V piano type switch ISI marked & ceiling rose ISI marked mounted on MS box having from bakelite cove r of suitable sizr, MS box with 1.0 sqmm FR PBC insulated single core multistrand copper conductor as earth wire including all accesorrie & connection as per direction of engineer is charge ( Make of wire = Finolex / L&T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100mm x 100mm x 60mm M.S. Box with bakelite cover - 1 no) --Group A (1.2.1-1.24.2) |
| 152 | do- Group A (1.2.1 - 1.24.2) |
| 153 | do- Group B (1.2.2 - 1.24.2) |
| 154 | do- Group C (1.2.2 - 1.24.2) |
| 155 | Recessed wiring to Fan Each in ….. Group B (1.2.2-1.24.2) |
| 156 | Group C (1.2.3-1.24.2) |
| 157 | Recessed wiring to C.B. Each in ……. Group C (1.2.3 -1.24.2) |
| 158 | Recessed wiring to Exh. Fan Each in …… Group C (1.2.3-1.24.2) |
| 159 | S/F of Metal box of 150mm x 75mm x 60mm deep (Normal size) in recess with suitable size of Phenolic laminated sheet cover in front including providing and and fixing 3 pin 5/6amp socket out let 5/6 amp piano type switch, connection, painting etc as required (1.26) |
| 160 | S/F of 5amp switch & 5A socket out let of ISI marked on existing board ( 1.25.1 & 1.25.4) |
| 161 | S/F of metal box of 180mm x 100mm x 60mm deep (Normal Size) in recess with suitable size of phenotic laminated sheet cover in front including providing & fixing 5 pin 15/16 amp. Piano type switch, connection, painting etc as required (1.27) |
| 162 | Wiring for cicruit / sub-main witing along with earth with following sized of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS - 694 / 1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PBC conduit as required (Make of wire - Finolex / L&T/ Anchor / Havels / V-Guard )2x1.5 sqmm + 1x1.0sqmm (1.8) |
| 163 | do - 2x2.5 sqmm + 1x1.5 sqmm (1.8.2 |
| 164 | do - 2x4 sqmm + 1x1.5 sqmm (1.8.) |
| 165 | P/Mtr 14 do - 2x6 sqmm + 1x1.5 sqmm (1.8.) |
| 166 | P/Mtr 15 do - 4x6 sqmm + 1x2.5sqmm (1.8.4) |
| 167 | S/F of Batten holder / BK angle holder of ISI Marked including connection etc instead of ceiling rose. (1.29 - 1.28) |
| 168 | Supply, Installation testing & Commissioning of Main switches (IS13940 part 3/1993) of following coopactity on existing surface, wall mounting & complete with H.R.C. Fuse links, inter connections earthing etc. as required as per direction of Engineer Incharge ( Make-Seimens / HPL /Anchor / L&T / Havels / C&S / R.K.) 63 Amp ICTPN Mainswithc (1.8.3) |
| 169 | S/G of B series SP MCB of 6 amp rating 240 Volt \"B\" series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissionning etc. as required single pole (SP) (2.6.1) |
| 170 | Each S/F of following way single pole and neutral sheet steel MCB Distribution Board 250v on surgace / Recess complete with tinned copped bus bar, neutral bar, earth bar, din bar, detachable gland plate,Distribution Board 250v on surgace / Recess complete with tinned copped bus bar, neutral bar, earth bar, din bar, detachable gland plate,interconnections, phosphatized and MCB / RCCB / Isolater) 4 way |
| 171 | Supply & fixing of following 2 way double pole neutral sheet MCB Distribution Borad 250 V on surface / recess complte with tineed copper bus bar, neutral bar, earth bar, din bar, detachable gland, plate, interconnections, phosphatized and powder painted including earthing etc. as required along with 32/40 AMP DP MCB (Legrand / Havells |
| 172 | Supply & Fixing of TPN M.C.B (Make - HPL, model - TTPNC40) |
| 173 | S/F of 16/18 SWG metal box of following sizes ( Nominal Size) in recess with suitable size of phenolic laminated shet cover in front including cutting the and making good the same in case of recessed conduit as required 100mmx100mmx60mm deep (1.24.2) |
| 174 | do- deep (1.24.5) |
| 175 | do 200mmx150mmx60mm deep (1.24.6) |
| 176 | Providing & fixing plain 16/0.2mm twin twisted flexible, FR PVC insulated copper cable in polythene sleeve or conduit of suitable size on the floor/ wall or side of the table/ door etc as required ( 1.31) |
| 177 | Supply, installation, testing & Commissioning of exhaust fan upto 450mm sweep in the exising opening, including making the hole to suit the size of the above fan making good the damged complete,connection, etc as reqired. (1.43) |
| 178 | S/F of call bell/ Buzzer ISI marked suitable for DC/AC single phase 230 volts complete as required. |
| 179 | S/F of computer board consisting of 4nos of 5amp plug and switch and 6amp MCB, indicator complete with wiring on (200mmx250mmx75mm) deep M.S. box with B.K. cover. ( 1.24.9 +1.25.2 + 1.25.4 + 2.5.1) |
| 180 | S/F of 15-20 watt LED single strip type tube light fitting ( make PAN/Phillips/ crompton/ polycab ) with all accessries and connections. |
| 181 | supply of 1200mm A.C. Ceiling fan with all accessories and connections with out fan regulator ( Make: Crompton highspeed ultra/ khaitan-Super Hibreeze/ Polycab - Amaze Hs/ Anchor- Flora ) |
| 182 | Supply & fixing of superior type C.I bulk head fitting with out Bulb for general domestic use ISI marked square/ oval type with premetallic glass cover provided with galvanized steel wire guard including necessary connections. ( M-S) |
| 183 | Supply and fixing of 60 watt Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections (Make -Crompton / Phillips / HPL / Polycab / PAC) |
| 184 | S/F of ceiling fan step type electronic regulator in existing switch board including connection and required earthing. |
| 185 | S/F of fan hook \"S\" type made of 16 mm MS rod for fixing in the Existing RCC Roof. |
| 186 | S/F of 9 Watt LED bulb |
| 187 | S/F of 4X10 Sqmm Al.Armoured Cable |
| 188 | S/F of 63 A TPN Pannel board size 30x24x10 sqinch with provn. Of 63A Roatary Main Switch with HRC Fuse (Make-siemens / HPL / Anchor / L&T / Havels), 1 nos 100A busbar, 63A DP MCB - 4 nos (HPL Model -TDPC50-63), 63 a TPN MCB (TTPNC 50-63), Indicating Lamp, 100 A |
| 189 | Special Earthing with G.I. Earth pipe 3 mtr long 40mm dia IsI marked including accessories & providing masonary enclisure with cover plate having locking aarangement & watering pipe with charcoal & salt as required (3.2) |