| 1 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engineer-in-Charge. |
| 2 | Dismantling mild steel framed trusses, rafter incl purlins complete all as specified and directed by Engineer-in-Charge. |
| 3 | Demolition of brick work built in cement mortar in any description and position, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Taking down chowkats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from frames), complete all as specified and directed by Engineer-in-Charge |
| 5 | Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 Sqm eachwith shutters (without taking off shutters from frames ), complete all as specified and directed by Engineer-in-Charge |
| 6 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar,complete all as specified and directed by Engineer-in-Charge |
| 7 | M & L for600x600x08 to 09mm thick coloured rectified tiles(joint less) (make of tiles as approved by GE)as in floor over and including 15mm thick screed bed in CM 1:6 including pointing in coloured cement to match the shade of tiles including hacking out the existing floor surface,cleaning with water and applying cement slurry @ 3 kg/sqm on prepared surface of floor and including cutting/adjusting of existing door shutter at required height after taking down and refixing complete all asspecified directed by Engr-in-Charge, make of tiles as approved by GE. Make-kajaria/Somany/Orient |
| 8 | M&L for machine cut kota stone slab as in flooring of size 550mm x550 mm 20-22mm thick over 15 mm thick cement screed bed in cm (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 9 | M&L for 2nd class hardwood plain, solid straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, complete all as specified and directed by Engineer-in-Charge |
| 10 | M&L for Surface dressing n exc 15 cm deep and site clearance complete all as specified and directed. |
| 11 | M & L for 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base all as specified. |
| 12 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurrylaid over 15mm thick screed bed in cm 1:6 asin floors withno pigment complete all as specified and directed |
| 13 | M & L for painting new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth,not otherwise described with two coats of synthetic enamel paint over a coat of red oxide complete all as directed. |
| 14 | S & F pre- painted galvatume aluminum zinc coating GI basedcorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 15 | S&F 0.63 mm thickness of Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of Zinc coating 275 complete all as specified and directed by Engineer-in-Charge |
| 16 | S&F Roof trusses (framed), truss, framedbrackets of angles, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel flat or hollow sections) including distance pieces, cleats etc. Fe 410-W(Gde E-250) quality-A complete all as specified and directed by Engineer-in-Charge |
| 17 | M&L for 75 mm thick cement concrete 1:3:6type C2(using 20mm graded stone aggregate). Plinth protection laid to a slope of 1 in 24 in alternate basis system. Each bay shall not exceed 3m in length, 12mm wide & 75mm deep joint shall be formed between the bays which shall be filled with Mastic filling to full depth comprising a mixture of 1 part of heator hot blow bitumen 85/25 portion and two parts of heated badrapur sand (by volume) complete all as specified and directed. |
| 18 | M & L for brickwork with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 |
| 19 | M&L for ready mix plaster of 15mm thick on brick or conc surfaces incl necessary cement slurry with bulk density 1.40 to 1.70 kg, water ratio 17 to 19% by weight & compressive strength as per IS 4031 part 6 smooth without using extra cement and applying three coats of white lime wash on newly plastered ceiling surfacesincluding taking down old plaster on ceiling complete all as specified. |
| 20 | M&L removing existing old treatment from walls using mechanical grinder and applying a uniform thickness (average 2-3 mm thickness) of cement based wall care putty of approved make (Birla/ Jk) using spray machine to the entire surface of walls and applyingtwocoats of Oil Bound Distemper onwall surfaces using Distemper Spray machine to give an even and smooth surfaceall as specified and directed. Make :- Asian paints (Royale)/NerolacPaints/ Berger (Rangoli) |
| 21 | M&L for ready mix plaster of 15mm thick on brick or conc surfaces incl necessary cement slurry with bulk density 1.40 to 1.70 kg, water ratio 17 to 19% by weight & compressive strength as per IS 4031 part 6 smooth without using extra cement and applying three coats of white lime wash on newly plastered ceiling surfacesincluding taking down old plaster on ceiling complete all as specified. |
| 22 | M & L for preparation of old surface of wall and applying two coat of cement based paint over one coat of primer from the same manufacturer including scaffolding if required complete all as specified and directed. |
| 23 | S & F Steel windows and ventilators with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded |
| 24 | S & F 3 mm sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 25 | S&F 35mm thick 2nd class Hard woodrail & style (factory made) plain, framed, paneled shutter with lock rail & panel of 12mm veneered particle board with commercial veneering on both sides (incl two nos 150 mm long extruded aluminium tower bolts, three nos 100mm long medium weight MS butt hinges, two nos 150 mm long extruded aluminium handles, one stopper,two nos 300 mm long Aluminum Sliding door bolts and two coats synthetic enamel paint along with one coat of pink primer)The size of rail & style as per IS :1003 (Part I), Kiln seasoned & chemicals pressure treated,complete all as specified and directed by Engr-in-Charge |
| 26 | M & L for painting old wooden Surfaces of any description, not otherwise described, over 10cm width or girth with two coats of synthetic enamel paint over a coat of pink primer all as directed. |
| 27 | M&L false ceiling using plain galvanized steel ceiling system consisting 600x600mm lay in tiles of pre coated galvanized steel sheets in 0.5 mm thick in white or coloured to be laid of grid system with 15mm wide T section flanged having rotary stitching on the main runner and 1200 mm corss tees. the main runner and 1200mm cross tees. The main runner spaced 1200mm centre flush fitting 1200mm long cross tees to be interlocked between runner at 1600mm centre to form 1200x600mm module. Permeter trim to be wall angle of size 3000x19x19mm secured to wall @ 450mm centre to centre and incldg. suspension system as per manufacturer instructions complete all as specified and directed by Engr-in-Charge and direced. Make: Armonstorng or equivalent. |
| 28 | S&F Powder Coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including aluminium alloy Powder coated standard 10mmsection window grill as per approved sample and as per IS specificationsjoining cleat for fixing etc. complete all as specified |
| 29 | S&FPowder aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.),hinges type B-21 100mm long (2no.) suitable handle ,(01 no.) complete all as specified. |
| 30 | S&Fstainlesssteel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized iron staples including wooden beadings, complete all as specified and directed. |
| 31 | S&F4.00 mmthick plain glass, pin head type andglazing with wooden beads, glass putty, PVC beading, aluminium beads, complete all as specified |
| 32 | Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) completefrom the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed. |
| 33 | M & L for Point wiring (concealed) complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through in and including non metallic medium grade rigid PVC conduit, ISI marked not less than 20 mm diaincluding all accessories concealed in wall by cutting chases and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty conductor including fabricated branded modular metal flush box duly make embossed, concealed in walls and with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:- |
| 34 | (a)One light /Ceiling fan/exhaust fan point controlled by one, one way switch . |
| 35 | (d) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. |
| 36 | (e) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board |
| 37 | All as per item no 33 herein before but with 4 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. |
| 38 | M&L switch Modular type 6 Amps230V AC complete all as specified. |
| 39 | M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified. |
| 40 | M&L switch Modular type 16 Amps230V AC complete all as specified and directed by Engineer in charge. |
| 41 | M&L Modular socket outlet 5 pin 6/16Amp universal socket 2 module complete all as specified.. |
| 42 | S&FModular five stepped type electronic fanregulator 2 module 360 degree rotatable type 230V AC complete all as specified |
| 43 | S&F ceiling rose surface PVC/Polycarbonate type with three terminals. |
| 44 | S&F LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 45 | S&F LED 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria,Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 46 | S&F LED 2 X 2 ft backlite surface mounted fitting 36/40 Wattsnot less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours ,Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed by engr-in-charge. |
| 47 | S&F 40 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70.The luminaire is IP:66 protected with IK05 impact resistance.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 25 mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.. |
| 48 | S&F heavy duty exhuast Fan 450mm sweep, 1400 RPM, metallic body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 1.5 sqmm completeall as specified and as directed. |
| 49 | S&F heavy duty exhuast Fan 300mm sweep, 1400 RPM, metallic body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 1.5 sqmm completeall as specified. |
| 50 | S&F factory made epoxy powder coated Distribution board (MCCB DB) TPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified. |
| 51 | S&F MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified. |
| 52 | S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete |
| 53 | S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete. |
| 54 | S&F MCB SPN 40 to 63 Amps 240 volts 10 KA 50 HZ \"C\" curve complete. |
| 55 | S&F MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve complete. |
| 56 | M&L of modular AC Box consisting of 20 Amp multipower socket including MCB of capacity 25 Amp mini MCB, ‘C’ curve, single phase 240 V, AC including modular metal box, frame, cover plate including plug top with indicator complete all as specified and directed by Engr-in-Charge |
| 57 | M&L for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed. |
| 58 | M&L for Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed. |
| 59 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron steel wire of 4mm dia by means of bolts nuts check-nuts and washers of galvanized ironor steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore lightgrade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified. |
| 60 | Supply,laying in repairs of PVC under ground XLPE insulated heavy duty electric cables armoured with aluminium conductor, 1100 volts grade, cross sectional area 35 sqmm 3.5 core laying in trenches, fixed along wall, through GI pipe under floor complete. |
| 61 | Supply,laying in repairs of PVC under ground XLPE insulated heavy duty electric cables armoured with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 2 core laying in trenches, fixed along wall, through GI pipe under floor complete. |
| 62 | Excavation in trenches n.exc 0.45 m wide and n.exc 0.60 m depth for laying of LT cables etc. and getting out in hard/dense soil soil soil complete all as specified |
| 63 | Returning filling in including spreading, levelling, watering and well ramming in layers n. exc. 25 cm complete all as specified. |
| 64 | Removal of excavation material not exc 50 Meter and depositing where directed at a level not exc. 1.5 M above the starting point complete all as specified and directed. |
| 65 | M&L for dry river sand filling in trenches as cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and as directed by EIC.Note :- Punned thickness only shall be measured and paid. |
| 66 | Supplying laying sub class ‘B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed. |
| 67 | Schedule of Credit |