Name of Work:Condition monitoring of Transformers under 220 kVOandMDivision Piran Kaliyar.
Sl. No.
Item Description
1
On site testing to be Conducted on 100 MVA, 220/132 kV Transformers I & II at 220 kV S/s Piran Kaliyar
2
(A) The following tests are to be carried outfor condition monitoring of100 MVA Transformers at 220 kV S/s Piran Kaliyar: i) Capacitance & Tan Delta of Bushings & Windings.ii) Turns ratio at each tap. iii) Vector group test.iv) Short circuit impedence test.v) Magnetizising current on each Tap. vi) Magnetic balance test.vii) Winding resistance at all taps.viii) IR & PI Test. ix) Sweep Frequency Response Analaysis (SFRA) test & Mechnical assesmnent.x) Moisture assesment & deielectric analysis of windings insulation ( FDS measurement). xi) Frequency Response on Stray Load (FRSL) test. xii) Leakage reacactance & Impedence Measurement. xiii) Dymnamic Contact resistance test for OLTC performance Checkxiv) on the Acoutic Partial dis charge test by Multi channel sensor and PD localization. xv) Thermography Measurement,Noise measuremnet and vibration measurement test.Oil test from NABL approved Lab.General oil test as per IS 1866:2000 (resistivity, tandelta, B.D.V , Water content PPM, IFT, Acidity, Flashpoint and sludge content). DGA as per relvent IECand Furan Anlysis.
3
On site testing to be Conducted on 40 MVA Transformers I, II & IIat 132 kV S/s Bhagwanpur
4
(B) The following tests are to be carried outfor condition monitoring of 40 MVA, 132/33 kV Transformers at 132 kV S/s Bhagwanpur:i) Capacitance & Tan Delta of Bushings & Windings.ii) Turns ratio at each tap.iii) Vector group test.iv) Short circuit impedence test. v) Magnetizising current on each Tap.vi) Magnetic balance test. vii) Winding resistance at all taps.viii) IR & PI Test. ix) Sweep Frequency Response Analaysis (SFRA) test & Mechnical assesmnent. x) Moisture assesment & deielectric analysis of windings insulation ( FDS measurement). xi) Frequency Response on Stray Load (FRSL) test.xii) Leakage reacactance & Impedence Measurement.xiii) Dymnamic Contact resistance test for OLTC performance Check xiv) on the Acoutic Partial dis charge test by Multi channel sensor and PD localization.xv) Thermography Measurement,Noise measuremnet and vibration measurement test.Oil test from NABL approved Lab.General oil test as per IS 1866:2000 (resistivity, tandelta, B.D.V , Water content PPM, IFT, Acidity, Flashpoint and sludge content). DGA as per relvent IECand Furan Anlysis.
5
To-Fro Travel Fixed Charges with required test equipments per visit.
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.