Name of Work: Construction of One Triple Storey barracks at RTC Bhondsi Distt. Gurugram.
Sl. No. Item Description
1HSR CIVIL ITEMS
2Earth work in excavation by mechanical mean (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 4.14.1 All kinds of soil
3Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. HSR 4.15.1 Ordinary rock
4Providing and laying in position cement concrete of specifiedgrade excluding the cost of centering and shuttering - All workbelow plinth level and up to Floor IV level :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size)HSR 6.1.6
5Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). HSR 6.16
6Providing and laying in position ready mixed M-25 gradeconcrete for reinforced cement concrete work, using fly ash andcement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is@ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix. (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456 -2000 in the items of BMC and RMC. HSR 6.28.1 All works up to Plinth level.
76.28.2 All works above plinth & up to floor IV level.
8Centering and shuttering including strutting, propping etc. andremoval of form for HSR 6.30.1 Foundations, footings, bases of columns, etc. for sqm mass concrete
9Centering and shuttering including strutting, propping etc. andremoval of form forWalls (any thickness) including attached pilasters,buttresses, plinth and string courses etc. HSR 6.30.2
10Centering and shuttering including strutting, propping etc. andremoval of form for Suspended floors, roofs, landings, balconies and Shelves (Cast in situ) HSR 6.30.3
11Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5
12Centering and shuttering including strutting, propping etc. andremoval of form for Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6
13Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Cold twisted bars HSR 6.33.3
14Brick work with common burnt clay modular bricks of classdesignation 7.5 in foundation and plinth in: HSR 7.20.1 Cement mortar 1:4 (1 cement: 4 coarse sand)
15Tile brick masonry work 5 cm thick with common burnt clay non- sqmmodular tile bricks of class designation 1 O in cement mortar 1 :3(1 cement: 3 coarse sand) in superstructure above plinth and Up to floor four level. Hsr 7.35
16Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor IV level in cement mortar 1 :4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of masonry work HSR 7.50
17Providing and laying autoclaved aerated cement blocks masonrywith 150mrn/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in- Charge. (The payment of RCC band and reinforcement shall be made for separately).HSR 7.51
18Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Hsr 8.27 .1 Marble work
19Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neatcement, rounding the edges and making and finishing the outlet complete. HSR 9.18
20Providing and fixing on wall face Unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter HSR 9.57.2
21Providing and laying Cement concrete flooring 1: 2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc.CompletEHSR 10.10.1 40 mm thick with 20 mm nominal size stone aggregate
22Providing and laying of chequered terrazzo tiles 20 to 22 mm thick withgraded marble chips of size up to 6 mm in floors, jointed with neat cement sluny mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1 :4 (1 cement :4 coarse sand) HSR 10.29.1 Light shade pigment using white cement
23Providing and fixing of Kota stone slab flooring over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand) : HSR 10.37.1 25 mm thick
24Providing and fixing of Kota stone slabs 20 mm thick in risers of steps,skirting, dado and pillars laid on 12 mm (average) thick cemEnt mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishingcomplete. HSR 10.38
25Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cementsand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.47
26Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size asapproved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete HSR 10.58
27Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming toIS : 15622, of approved make, in all colours, shades, except White, Ivory,Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1 :4 (1Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding pointing the joints with white cement and matching pigments etc.,complete. HSR 10.59
28Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. HSR 10.63.2 Size of Tile 600x600 mm
29Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser ofsteps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. HSR 10.67.2 Size of Tile 600x600 mm
3010 mm thick cement plasterHSR 11.4.2 1 :3 (1 cement: 3 fine sand)
3115 mm cement plaster on the rough side of single or half brick wall of mix : HSR 11.6.1 1 :4 (1 cement: 4 fine sand)
32Providing and fixing of chicken wire mesh for avoiding cracks in plaster withnecessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge HSR 11.17
33Providing and applying 12 mm thick (average) premixed formulated one coatgypsum lightweight plaster having additives and light weight aggregates as vermiculite/ per1ite respectively conforming to IS: 2547 (Part - 1 & II) 1976,applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. HSR 11.46
34Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60
35Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade: HSR 11.64.1 New work (two or more coats) over and including water thinnablepriming coat with cement primer
36Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:HSR 11.67.1 Water thinnable cement primer
37Preparation of ply wood surface for painting including sand paperingthe surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76
38Applying pink primer or aluminium priming coat on wood work includingpreparation of surface, Knotting and stopping etc. HSR11.77
39Painting two coats excluding priming coat with synthetic enamel paint in allshades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78
40Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 litre/1 O sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)HSR 11.95.1
41Providing and fixing ISi marked flush door shutters conforming to IS : 2202(Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. HSR 12.36.1 35 mm thick including ISi marked Stainless Steel butt hinges withnecessary screws
4225 mm thick (for cupboard) including ISi marked nickel plated sqm bright finished M.S. Piano hinges IS 3818 marked with necessary screws HSR 12.36.3
43Providing and fi xing bright finished brass hanging type floor door stopper with eachnecessary screws, etc. complete. HSR 12.86
44Providing and fixing aluminium e xtruded section body tubular type universaLhydraulic door closer (having brand logo with ISi, IS: 3564, embossed on the body, door weight up to 3 6 kg to 80 kg and door width from 701 mm to 1 000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89
45Providing and fixing aluminium sliding door bolts, ISi marked anodised(anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : HSR 12.98.2 250x16 mm
46Providing and fixing aluminium tower bolts, ISi marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete HSR 12.99.5 100x10 mm
47Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. completeHSR 12.102.1 125 mm
48For shutters of doors, windows & ventilators including providingand fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of kg powder coating 50 micron)HSR 12.157.2.2
49Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): HSR 12.159.2 With float glass panes of 5 mm thickness (weight not less than sqm 12.50 kg/sqm)
50Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primerafter pre-treatment of the surface as directed by Engineer-in-charge: 13.3.2.2 Fixing with carbon steel galvanised dash fastener m of required dia and size (to be paid for separately)
51Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) HSR 13.3.3.2
52Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mmangle iron and 3 mm M.S. gusset plates at the junctions and comers, all necessary fittings complete, including applying a priming coat of approved steel crimer.HSR13.6.2 Using flats 30x6mm for diagonal braces and central cross piece
53Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with HSR 13.10.1 4.0 mm thick glass panes
54Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates kgand similar works HSR 13.29.2
55Granular Sub-Base with Close GradedMaterial· (Table:- 400-1) Plant mix method Construction of granular sub-base by providingMaterial as per Grading Ill (Table 400-1 of MORT&H 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications HSR 17.14.1 Grading I material
56Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushingstrength at the end of 28 days to be not less than 30 N/Sqmm2). DSR 26.32.1 12 mm average thickness HSR=31.7 @156 B
57TOTAL HSR ITEMS
58HSR PUBLIC HEALTH ITEMS
59Excavating trenches of required width for pipes, cables, etcincluding excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: HSR 4.16.1.2 Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm dia
60Providing and fixing of Kota stone slabs 20 mm thick in risers of steps,skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR 10.38
61Cutting holes up to 23 cm square through brick work in mud walls for pipesand making good induding repointing, replastering and finishing according to existing finish where required. HSR 20.25.2 22.86 cm thick wall
62Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benching 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neatcement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 21.84.3 Size 600 mm X900 mm inside (with 455 mm x 455 mm coverand frame light duty single seal weighing 20 kg with R.C.C. slab)
63Extra for every 0.30 metre depth of Inspection chamberHSR 21.85.1 450 mm x 450 mm inside
64Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.HSR 22.14.1 Semi rigid pipe HSR 22.14.1.1 32 mm dia
65Providing and fixing white vitreous chinaware flat back or wall comer typelipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: HSR 22.25.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern HSR 22.25.1
66Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge HSR 22.86.3 25 mm nominal outer dia Pipes
6732 mm nominal outer dia Pipes HSR 22.86.4
68Providing salt glazed stone ware pipes grade "A" in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 250mm i/d HSR 21.94.4
69Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing &fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) intothe wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts andgasket etc complete. HSR 22.33
70Providing and fixing partitions for different type of urinals. 22.50.1 Vitreous Chinaware Partition plate. HSR 22.50.1.1.2 Single Colour
71Providing and fixing brass bib cock of approved quality:HSR 22.96.1 15 mm nominal bore
72Providing and fixing brass stop cock of approved quality: HSR 22.97 .1 15 mm nominal bore
73Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)22.98.1 25 mm nominal bore
74Providing and fixing Unplasticised PVC connection pipe with brass unions: 22.101.2 45 cm length HSR 22.101.2.1 15 mm nominal bore
75Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : HSR22.103.2 20 mm nominal bore
76Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. HSR 22.106.1 15 mm nominal bore
77Providing and fixing PTMT towel rail complete with brackets fixed to woodencleats with CP brass screws withConcealed fittings arrangement of approved quality and colour. HSR 22.119.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
78Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. HSR 22.127
79Providing and fixing rectangular high density polyethylene water storage lofttank with cover, conforming to ISi : 12701, colour of opaque wHite or as approved by Engineer-in-charge. The rate includes making necessary holesfor inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. HSR 22.182
80Providing and fixing in position vitreous chinaware white lavatory suites ofapproved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect HSR22.221.2 Size 550 mm x 400 mm x 815 mm
81Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green.Overlaps of joints of fibre cloth should not be less than 1 O cm.(c) third layer of 1.5 mm thickness consisting of sluny of cement @ 1.289kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hoursfollowed by water curing for 48 hours. The entire treatment will be taken up to30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paidfor separately).For the purpose of measurement the entire treated surface will be measured. HSR 28.16
82Providing and fixing in position singel socket SWR UPVC soil waste orantisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 22.222.2 Single Socket Type BHSR 22.222.2.2 110mm old SWR UPVC pipe lines laid complete
8322.222.2.3 90mm old SWR UPVC pipe lines laid complete
84a) 110mm dia pipe
85Bend
86socket
87Door Tee
88Floor / trap/p. trap
89clamp
90COWEL
91Special for 90mm Special
92bend
93Floor Trap/ Nahani Trap
94socket
95COWEL
96CLAMP
97TOTAL HSR PH ITEMS
98NS CIVIL ITEMS
99Providing & fixing 25-30 mm thick red sand stone first quality for cupboard shelves and Partitions inclding slightly round edge complete in all respect NS
100P & F stainless steel wire mesh jali of 22 gauge, clear aperture 1.4mm in 304 grade in aluminium door & window in aluminium section including PVC/Neoprone gasket & Labour for fixing including cost of MS Frame wire for SS Jali complete in all respect. (excluding the coast of beading, channel etc, the same will be paid in aluminium work).NS
101Providing & Injecting chemical emulsion for Antitermite with using Imidacloprid 0.075% concentration PCI solution
102Providing & fixing of ACP sheet 4 mm thick as per approved NS
103TOTAL NS CIVIL ITEMS
104NS PH ITEMS
105Providing & fixing C.P Jali heavy quality, 100mm dia of standard make approved by engineer-in-charge complete in all respect
106TOTAL NS PH IEMS
107HSR ELECTRICAL
108HSR 20.71) Supply, erection, testing of Ceiling fans IS marked (as per IS code 374)with suitable GI pipe complete in all respects complete as per directions ofEngineer-in-charge.
10920.71.1) 48" (1200mm)
110(HSR 23..4 ) COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT
11123.4.1) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copperconductor cable in 1.6 mm thick PVC conduit pipe.
11223.4.1.1 ) Group A
11323.4.2) Wiring for Twin Control Light point with 2nos., 2 ways , 5Amp.modular type switch ,GI box andModular type face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.
11423.4.2.1 ) Group A
11523.4.4) Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required
11623.4.4.1 ) Group A
11723.4.5) Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required
11823.5.5.1) Group A
119HSR 23.3.6 ) Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVCinsulated Copper conductor cable1100 Volts grade in PVC Conduit etc as required
12023.3.6.1) 1 run of size 1.50 sqmm (1/1.40mm)
12123.3.6.3) 1 run of size 4.0 sqmm (1/2.24mm)
12223.3.6.4 ) 1 run of size 6 sqmm (1/2.80mm)
12323.3.6.5 ) 1 run of size 10 sqmm (1/3.50mm)
124HSR 23.7.6 ) Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box ,iron hooks and cement concrete etc. completein all respect upto the entire satisfaction of Engineer-in-charge of work.
12523.7.6.2) PVC Pipe 25mm dia.
126HSR 23.8.1) Providing and fixing Piano type accessories of approved make in existingbox and Bakelite sheet including fixing and making necessary connections,complete in all respect.
12723.8.1.5) Ceiling rose flush/surface type
12823.8.1.12) Bakelite angle/straight button holder large size.
129HSR 23.8.10) Providing and fixing GI concealed sheet metal boxes with inner and outer face plate i/c concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required to complete the job in all respect
13023.8.10.1) 1 & 2 Modules including combined plate for telephone & data
131HSR 23.8.4) Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C.slab for the erection of fan complete with all labour and material required to complete the job
132HSR 23.8.11) P/F Modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect.
13323.8.11.7) Step type Fan Regulator 2 modules 300 watt
13423.8.11.9) T.Vsocket outlet modular type
13523.8.11.10) Blanking plate
136HSR 23.8.12) Supply and Fixing of 3mm thick bakelite sheet cover on existingMS/PVC junction box/ tee etc. including fixing with brass screws and washers.
137HSR 23.22.1) Supply and erection of Modular case circult breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections requried to complete the job in all respect up to the entire satisfaction of the Engineer-in charge of the work.
13823.22.1.9 ) 4 pole MCCB 6 amp to 100 amp, 25 KA
139HSR 23.22.4) Supply and erection of Double door sheet steel enclosure distribution board suitable for MCB"s and ELCB"s etc. recessed in wallincluding bonding to earth with all labour & material reqd. to complete the job in all respect up to the entire satisfaction of the Engineer-in charge of the work.
14023.22.4.2 )SPN DB Double Door 8 way ( 2 incoming and 6 outgoing
14123.22.4.6 ) TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing)
14223.22.4.10 ) Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing)
14323.22.4.11 ) Vertical TPN DB double door 8 way (8 incomming & 3phase x 6 outgoing)
144HSR 23.22.5 ) Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections.
14523.22.5.1) 6 amp. to 32 amp Single Pole
14623.22.5.4 ) 6 amp. to 63 ampMCB Double Pole
14723.22.5.5 ) 6 amp. to 32 amp MCB"s TRIPLE POLE
14823.22.5.7) 6 amp. to 32 amp MCB"s FOUR POLE
149HSR 23.22.7 ) Supply and Erection of blanking sheet in existing distribution boards.
150HSR 24.1 ) EARTHING AND LIGHTENING ARRESTOR
15124.1.3) Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) complete as required.
15224.1.5) Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode
15324.1.7) Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
15424.1.8) Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
15524.1.14) Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I.staples of same size.
156H.S.R 24.2)L.T. CABLE
157Laying of underground cable in pipe /existing open/closed trench etc as reqd.(HSR-24.2.4)
15824.2.4.2) 16 sqmm to 35 sqmm 2 to 4 Core
15924.2.4.3) 50sqmm to 150 sqmm 2 to 4 Core
160HSR-24.2.7) Supply and erection of suitable compression type brass cable glands for underground Cable :-
16124.2.7.3) 25 sqmm to 50 sqmm Cable 2 to 4 Core
16224.2.7.4) 70 sqmm to 95 sqmm Cable 3 to 3.5 Core
163HSR-24.2.8) Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work .
16424.2.8.5) 25sqmm
16524.2.8.6) 35sqmm
16624.2.8.8) 70sqmm
167HSR-24.5.2)S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.
16824.5.2.3)DWC/HDPE pipe 63/50 mm outer dialinner dia
16924.5.2.4)DWC/HDPE pipe 90/75 mm outer dialinner dia
170HSR- 32.70) Supply, Installation, testing and commissioning of Solar Photovoltaic grid connected rooftop plant confirming to MNRE specifications as amended consisting of Mono /Poly crystaline silicon Solar cells, Net metering facility, necessary protections,earthing, mounted on Aluminium / G.I structure of suitable strength with following components complete as required:-
171a) Solar Photovoltaic Module manufactured in India, conformingto IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part- 2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 1 O years and 80% at the end of 25 years.
172b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC
173c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from O to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency
174d) Data Monitoring System complete with accessories
175e) Fixing of Array junction box & Main junction box with IP 65protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.
176f) Lightning and surge voltage protection
177g) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV gradearmoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessoriesetc. as required.
17832.70.1) Above 1 Kwp and upto 10 Kwp
179E.I HSRAmount (A)
180E.I NS Part
181S/E of fresh air fans(Exhaust fan) 250mm sweep PVC body with louver shutter, suitable for single phase A.C 230 volts, 50Hz supply complete with all labour and petty material required to complete the job.(Haveell"s Make& Model Ventlar DX or Cormpton Greaves Make & Model Brisk Air) or its equivalent from approved list of make.
182S/E of LED 10 watt rectangular bulk head fittingwith opal diffuser i/c erection of fitting in wall/Ceiling & making necessary connection to complete the job with all labour and petty material as required.
183Supply and erection of surface/ Recessed mounting, energy efficient LED 6000 K luminaire, complete with diffuser, HF electronic driver and other material required to complete the job including fixing the same on surface or in false ceiling with required material & making necessary connections etc :-
184i) LED 36W Flat Panel ( 2"x2" )
185ii) LED 15 W/18 W Square Fitting
186S/E of surface mounting LED Batten fitting 1x 20 watt, (4 feet long),made of thermal poly carbonate body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230 Volts, 50 HZ supply, complete in all respect.
187S/E of 60 watt LED Flood Light pressure die casthousingwith IP-65 Protection and efficient LED output for better distribution to be mount on existing building/ terrace complete in all respect.suitable for operation on 230 volts A.C supply.
188S/I/T/C of water cooler stainless steel body with 150 ltr /hr and 150 ltr storage capacity complete in all respect i/c all labour and petty material as per approved make list of HPHC.
189S/E of fire existingushers duly erected/hangs on wall with hooks i/c the cost of hook, screws etc with all labour and material required to complete the job in all respect to the entire satisfaction of the Engineer- in - Charge of the work.
190i)ABC type 4 Kg capacity
191ii)CO2 type 4.5 Kg capacity
192Supply &Erection ofCommercial Mineral RO systemof 50 Ltr/ hr. water Purification Capacityi/c fixing on wall with all petty material and labour reqd. (Make-Kent &Eureka Forbes ) or its equivalent from approved list of make.
193Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm soild copper conductor PE insulated, shieeeeelded with fine tinned copper braid and protected with PVC sheath in the existing surfca/recessed steel/PVC conduit as required.
194Supply and erection of 55” ultra HD LEDsmart TV (Samsung – Makeor equivalent model ofSony/Pansonic/LG orequivalent in approved HPHC make list)complete in all respect including making necessary connections etc but w/o cost of TV Cable & Set up box & disc.
195S/I/T/C of high wall1.5 TR capacity invertor type of 5 Star rating SplitAir- conditioning unit(Make-HITACHI or equivalent as per approved make HPHC List) rated at 220 volts (+) (-) 10%,single phase, 50 c/s electric supply and consisting of condensing and indoor unit,control panel of the unit, LCD Cordless remote, internal control wiring, thermostats & all accessories reqd., MS stand , 4 KVAcopper wound wall mount voltage stablizer , first charge ofGas & oil including 3.0 mtr.copper refrigerant & drain pipe. The work shouldbe completed in all respect including making repair of wall,floor and roof in original shape caused by making holesand chases etc.
196Supply, installation, testing and commissioning of refrigerant piping made of good quality copper tube with insulationof required dia recessedin wall or on Surface with Covering chanel for Split Air-conditioner of 1.5 TR/ 2 TR cap.complete with all labour and petty material required to complete the job.
197Supply, installation, testing and commissioning of CPVC drain Pipe of required dia for 1.5 TR/ 2 TR cap Split /Cassette type Air-conditioner recessedin wall oron surface complete with all labour and petty material required to complete the job.
198S/E PVC insulated 4 core 2.5 sqmm copper conductor cable ( un armd.) 1100V , grade in existing pipe, complete with all labour and petty material required i/c making necessary connections.
199Design, manufacture, supplying fixing in position of the following front operated cubicle type,compartmentalised with front access, dead back, 2mm thick steel enclosed free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 25 KA symmetrical at 415 volts.
200A) INCOMER
2011 No. 160 amps 4P MCCB(25 KA) with thermal Magnetic release with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.
202B) METERING & INDICATION
203i) 1 set of R,Y,B phase indicating lamps
204ii) 1 No. (0-500V) digital Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
205iii) 1 No. AVF meter with matching cast resin CT"s.
206C) BUS-BAR
207i) 1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves.
208D) OUTGOINGS
209i) 5 Nos. 100A 4P MCCB (25 KA)
210Supply of LT Armoured Cable of1100 volt grade complete with making necessary connection of cable on both ends including loading unloading & carriage with all labour and petty material required to complete the job upto the entire staisfaction of Engineer - In - Charge of the work of following sizes :-
211i)LT Armoured Cable of size 25 sqmm 4 core
212ii)LT Armoured Cable of size 35 sqmm 4 core
213iii)LT Armoured Cable of size 70 sqmm 3.5 core
214Total Amount ( E.I NS Part )