}

Special Repair Of Barracks At Cm Residence Sector 2, Chandigarh, chandigarh-Haryana

Haryana Police Housing Corporation Limited has published Special Repair Of Barracks At Cm Residence Sector 2, Chandigarh. Submission Date for this Tender is 13-06-2022. Barrack Tenders in chandigarh Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

32416509
Special Repair Of Barracks At Cm Residence Sector 2, Chandigarh
Open Tender
Indian
Haryana
chandigarh
13-06-2022

Tender Details

Special Repair Of Barracks At Cm Residence Sector 2, Chandigarh

Key Value

Document Fees
INR 15000 /-
EMD
INR 224000.0 /-
Tender Value
INR 1.12 Crore /-

BOQ Items

Name of Work: Special Repair of barracks at CM residence Sector 2, Chandigarh
Sl. No. Item Description
1Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m: HSR 4.19 4.19.1 Ordinary rock 4.19.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
2Demolishing mud phaska in terracing and disposal of material within 50 metres lead.HSR 5.11
3Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. HSR5.14
4Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: HSR 5.15 5.15.2 Asbestos Cement sheet
5Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.HSR 5.23 5.23.2 Nominal concrete 1 :2:4 or leaner mix (i/c equivalent design mix)
6Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. HSR 5.43 5.43.1 For thickness of tiles 10 mm to 25 mm
7Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. HSR 5.49
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level:HSR 6.1 6.1.1 1 : 1 ½: 3 ( 1 Cement: 1 ½ coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size)
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level:HSR 6.1 6.1.6 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size)
10Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in :HSR 7.22 7.22.2 Cement mortar 1:6 (1 cement: 6 coarse sand)
11Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platfonns, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.HSR 8.26 8.26.2 Granite of any colour and shade 8.26.2.2 Area of slab over 0.50 sqm
12Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil completeHSR 9.10 9.10.1 With residual type petroleum bitumen of grade VG -10
1310 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:HSR 9.11 9.11.1 With common burnt clay non-modular brick tile of class designation 10
14Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design :HSR 9.17 9.17.1 In 75x75 mm deep chase
15Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. HSR 9.47 9.47.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
16Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.HSR 9.58 9.58.1 Coupler 9.58.1.1 75 mm
179.58.1.2 110 mm
189.58.1.3 150 mm
19Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.HSR 9.58 9.58.3 Single tee with door 9.58.3.1 75x75x75 mm
209.58.3.2 110x110x110 mm
219.58.3.3 150x150x150 mm
22Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.HSR 9.58 9.58.5 Bend 87.5° 9.58.5.1 75 mm bend
239.58.5.2 110 mm bend
249.58.5.3 150 mm bend
25Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.HSR 9.58 9.58.6 Shoe (Plain) 9.58.6.1 75 mm Shoe
269.58.6.2 110 mm Shoe
279.58.6.3 150 mm Shoe
28Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. HSR 10.1
29Providing and laying of conglomerate floor 50mm thick cement concrete topping 1 :2:4 HSR 10.7
30Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. HSR 10.58
31Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.. HSR 10.106
32Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58
33Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:HSR 11.64 11.64.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
34Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.HSR 11.78
35Finishing walls with Acrylic Smooth exterior paint of required shade :HSR 11.95 11.95.1 New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
36Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with HSR 13.10 13.10.1 4.0 mm thick glass panes
37Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.HSR 13.28
38Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). HSR 22.8 22.8.1 One way
39Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. HSR 22.14 22.14.2 Flexible pipe 22.14.2.1 32 mm dia
40Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:HSR 22.22 22.22.1 White vitreous chinaware Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests
41Providing and fixing white vitreous chinaware flat back or wall comer type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:HSR 22.25 22.25.2 One urinal basin with manually operated 5 litres PVC cistern and manually operated stop cock/ angle valve
42Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
43Providing and fixing partitions for different type of urinals.HSR 22.50 22.50.1 Vitreous Chinaware Partition plate. 22.50.1.2 Large size 835mm x 355 mm 22.50.1.2.1 White
44Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.HSR 22.86 Concealed work, including cutting chases and making good the walls etc. 22.86.2 20 mm nominal outer dia Pipes
4522.86.3 25 mm nominal outer dia Pipes
4622.86.4 32 mm nominal outer dia Pipes
47Providing and fixing Unplasticised PVC connection pipe with brass unions: HSR 22.101 22.101.2 45 cm length 22.101.2.2 20 mm nominal bore
48Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931HSR 22.104 22.104.1 15 mm nominal bore
49Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. HSR 22.106 22.106.1 15 mm nominal bore
50Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. HSR 22.107 22.107.1 15 mm nominal bore
51Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109
52Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.HSR 22.117
53Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.HSR 22.118
54Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. HSR 22.219 22.119.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
55Providing and fixing PTMT grating of approved quality and colour. HSR 22.123 22.123.1 Circular type 22.123.1.2 125 mm nominal dia with 25 mm waste hole
56Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. HSR 22.127
57Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:HSR 22.166 22.166.1 100x100 mm size P type 22.166.1.1 With common burnt clay non-modular bricks of class designation 7 .5
58Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1 :4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x61 O mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1: 1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1 : 3 ( 1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: HSR 22.179 22.179.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 22.179.1.1 With common burnt clay non-modular bricks of class designation 7 .5
59Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.HSR 22.181
60Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : HSR 22.210 22.210.2 Rectangular shape 453x357 mm
61Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-incharge.HSR 22.216 22.216.1 25 Litres capacity
62Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect.HSR 22.221 22.221.9 Size 560mm x 450mm (Under counter oval)
63Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. HSR 22.222 22.222.2 Single Socket Type B 22.222.2.1 160mm old SWR UPVC pipe lines laid complete
6422.222.2.2 110mm old SWR UPVC pipe lines laid complete
6522.222.2.4 75mm old SWR UPVC pipe lines laid complete
66Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. HSR 30.22
67Renewal of old putty of glass panes (length)HSR 30.58
68Refixing old glass panes with putty and nailsHSR 30.59
69Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia up to 300mmHSR 30.91
70Supply and fixing of 70/40mm PUF Insulated Roof Panel with 0.50mm thick corrugated profile sheet from outside and micro ribbed 0.50mm thick PPGI (Make-JSW) inside infill with fire retardent Grade PUF Density 42kg/m3 + 5% with proper overlapping to prevent the water leakage and projections on all sides. free & ozone friendly.( Pentane Based). Installation of Roof Panels with complete hardware and silicon sealant. NS
71Providing and fixing 1.6 feet deep Cup Board with 19mm plyboard with 6mm thick ply Green make & 4mm thick veeneer teak in front with PU Polish and interior with Synthathic enamel paint complete in all respect NS
72Total A (HSR + NS Items)
73Credit of Old material
74Good Qty tiles
75Brick Bats
76Total B
77HSR/NS Items E.I
78Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. (HSR 20.71)
7920.71.1) 48" (1200mm)
8020.71.2.) 56" (1400mm)
81Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe (HSR 23.4.1) (-15%for surface wiring)
8223.4.1.1) Group A
83Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch. (HSR 23.4.3.) (-15%for surface wiring)
8423.4.3.1.) Group A
85Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required (HSR23.4.4.) (-15%for surface wiring)
8623.4.4.1) Group A
87Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required.(HSR 23.4.5.) (-15%for surface wiring)
8823.4.5.1) Group A
89Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. (HSR 23.5.6.)
9023.5.6.1.)1 run of size 1.50sqmm (1/1.40mm)
9123.5.6.2.) 1 run of size 2.50sqmm (1/1.80mm)
9223.5.6.3.) 1 run of size 4sqmm (1/2.24mm)
93Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 23.8.10.)
9423.8.10.1) 1 & 2 Modules including combined plate for Telephone and data
9523.8.10.2) 3 Modules
9623.8.10.4) 6 Modules
9723.8.10.5) 8 Modules
9823.8.10.6) 12 Modules
99Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.(HSR 23.8.11.)
10023.8.11.1.) 5 amp 1 way switch
10123.8.11.4.) 5 amp socket
10223.8.11.3.)15 amp 1 way switch
10323.8.11.5.)15 amp 6 pin socket
10423.8.11.10.) Blinking plate
10523.8.11.7.) step type Fan regulator 2 modules 300 watt
106Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 23.22.1)
10723.22.1.4) TRIPLE POLE MCCB 125 to 160 Amp, 25 KA
108Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work (HSR 23.22.4.)
10923.22.4.2.)SPN DB Double Door 8 way ( 2 incoming and 6 outgoing)
11023.22.4.3) SPN DB Double Door 12 way ( 2 incoming and 10 outgoing)
111Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- (HSR 23.22.5.)
11223.22.5.1) 6 amp. to 32 amp Single Pole
11323.22.5.2) 40 amp to 63 amp. (SPN)
114Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). (HSR 23.24.3)
11523.24.3.2.)100 amp 4 bars of 55 cm each (cross section 25 mm x6 mm) chamber over all size 60 cm x 45 cm x 18cm
116Dismantling old wiring points ( surface wiring system) including necessary repairs to wall etc.(HSR 23.25.1.)
11723.25.1.1) Light, fan or call bell Point including circuit/sub main wiring
11823.25.1.2.) Wall socket point including circuit/submain wiring
119Earthing and lightening arrestor(HSR24.1)
12024.1.1.)Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
12124.1.2.) Extra for using salt and char coal/coke for pipe earth electrode as required.
12224.1.8) Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess forconnections etc. as required with all labour and material.
123Laying of underground cable in pipe /existing open/closed trench etc (HSR 24.2.4.)
12424.2.4.1)2.5 Sq mm to 10 Sq mm 2 to 4 Core
12524.2.4.2) 16 Sq mm to 35 sqmm 2 to 4 Core
126Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-incharge
12722.216.1)25 Litres capacity
128Total (HSR + CP ) Amount
129NS Items
130S/E PVC pipe ISI Marked heavy guage i/c bendinspection box etc., i/c laying of pipe in slab or wall complete with all patty material required to complete the job in all respect.
131ii)Size 25 mm dia (Recessed Type)
132ii)Size 25 mm dia (Surface type)
133Surface & Erection of surface mountingLED Batten fitting 1 x18 watt, (4 feet long) made of high grade poly carbonate body provided for efficent heat dissipation & integrated electronic driver suitable for single phase A.C. 230 volts , 50 Hz supply complete in all respect. Make as per brand list
134S/E of ISI marked propeller type ventilating fans (Exhaust fan) suitable for single phase230 Volt, 50 Hz AC, capacitor run confirming to IS:23/2/67 complete with mounting rings with four no. fixing holes without regulator as per following specification under general technical requirements.
1351. sweep = 300 mm
136S/E of louver shutter for exhaust fan including all labour comlete in all respect.
137S/E of Exhaust fan PVC body 250 mm outer with louver shutter and petty material required to complete the job in all respect.
138Supply and erection of energy efficent LED 6000 K Round Luminiare complete with diffuser, energy efficent electronic driver and other material required required to complete the job including fixing the same in false ceiling with required material& making necessaryconnection etc:
139i) LED 36 W recess mounting2"x2"(Make as per brand list)
140ii) LED 36 W surface mounting2"x2"Make as per brand list
141Supply and erection of energy eficent LED 6000 K round luminiare , complete with diffuser , energy efficent electronicdriver and othermaterial required to complete job including fixing the same in false ceiling with required material and making necessary connection etc. i) LED 15/18 W square fitting surface mounting (Bajaj make or as per approved brand list)
142Supply of LT armoured/ Unarmoured cable of following 1100 Volt and complete with making necessary connection of cable on both ends including loading, unloading and carriage with all labour and petty material required to complete the job upto the entire satisfaction of Engineer-in-Charge of the work.
1431) LT unarmoured cable of size 10sqmm 2 core
1442) LT armoured cable of size 10 sqmm4 core
1453) LT armoured cable of size 25 sqmm 3.5 core
146S/E of PVC Batten / Channel with all petty material like rawal plug , wooden / steel, screws etc. (ISI marked) ii) 25mmx 16mm
147Supply and erection of 72 watt Edge LED street light comes with pressure die cast housing toughned glass and individual LEDs with secondary optics and IP66 Protection . Make asper approved Brand list
148Supply and erection of M.K accessories complete in all respect. (white colour)
149i) PVC Commercial dado trunking of size 100mm x 50 mm NCT 1050
150iii) PVC Mounting switch Boxes 1-3 Module
151iv) PVC Mounting Switch Boxes 4-5 Module
152v) PVC Mounting Switch Boxes 8 Module
153S/E of Dessert cooler i/c connection and fitting and necessary material and fullsatisfation of Engineer of incharge of the work and complete in all respect 22 guage sheet powder coated.
154S/E of water cooler fully stainless stell body with 150 liter storage capacity and RO of 50liter capcacity makeKent per hour capacity with all labour required to complete the job in all respect.Make as per approved brand list
155Supply of wall fan 16"" Sweep (400mm) oscillating type light duty complete with built-in regulator , blade, jali complete.( Make Havells / Crompton make or equivalent approved)
156Total NS
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail