}

Supply Of Industrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Voltsindustrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Volts,Industrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Volts Ac At 50H-Tamil Nadu

Integral Coach Factory-ICF has published Supply Of Industrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Voltsindustrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Volts,Industrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Volts Ac At 50H. Submission Date for this Tender is 08-06-2022. Springs Tenders in Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

32395801
Supply Of Industrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Voltsindustrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Volts,Industrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Volts Ac At 50H
Limitted
Indian
Tamil Nadu
08-06-2022

Tender Details

Supply Of Industrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Voltsindustrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Volts,Industrial Metal Clad 5 Pin Plug Of Decontactor Rated For 63 Amps At 500 Volts Ac At 50Hz Supply Conforming To Iec 309-1 With The Following Features.1) The Plug Shall Be With Five Pins For Usen 3-Phase, 4 Wire Earthed System. The Five Nos Of Pin Correspond To Three Nos. For 3 Phases. One No. For Neutral And Balance Oneno.For Earth Connection. The Earth Pin Shall Be Such That Thecontact Shall Make First And Break Last With The Plug To Ensure Safety.2) The Plug Shall Be Such That It Gets Latched In The Fully Inserted Conditions With The Socket. When The Latch Is Depressed The Plug Shall Disengaged With Sufficient Speed To Simulate The Requirements For On Load Isolation. However The Plugshall Not Fall Off Till The Same Is Relieved With An Angulartwist. All The Contacts Shall Be Silver Tipped, Spring Loaded,Butt End Self-Aligning And Self-Wiping And The Temperaturerise Shall Be Less Than The Requirements Given In Iec309-1.3)Suitable Provision Shall Exist To Ensure Insertion Of Plug With The Socket Only In The Correct Position.4) The Terminals For The Conductor Connection Shall Be Suitable To Terminate Stranded As Well As Solid Conductors With Constant Force Making Use Of Elastic Ring On The Conductor.5) The Construction Shall Be Weather Proof Meeting The Requirements Of Ip-66.6) The Material For The Insulated Parts Shall Be High Grade Nylon Reinforced With Glass Fiber For Ensuring Wear Resistance And Resistance To Cracking.The Components In The Arcing Zone Shall Be Thermostat Polyester To Ensure Flame Retardant. The Housing Shall Be Aluminium Diecast.7) Suitable Provision Shall Exist For Clamping The Cable In The Plug To Avoid Strain At The Termination.8) The Plug Shall Be Dimensionally Identical To Cat.No.Ds6a7a1of Bch Make.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail