Purvanchal Vidyut Vitaran Nigam Limited has published Development Of Distribution Infrastructure Of Packagevaranasi 2 At Jaunpur, Ghazipur And Chandauli District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cable 2 Suppl. Submission Date for this Tender is 22-08-2022. Bolts Tenders in jaunpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 31-May-2022 | Time Extention | Date | 13-06-2022 |
2 | 10-Jun-2022 | TimeExtention | Date | 21-06-2022 |
3 | 21-Jun-2022 | TimeExtention. | Date | 04-07-2022 |
4 | 02-Jul-2022 | Time_ Extention | Date | 18-07-2022 |
5 | 16-Jul-2022 | Time-Extention | Date | 29-07-2022 |
6 | 29-Jul-2022 | Time__Extention | Date | 22-08-2022 |
Sl. No. | Item Description |
1 | Supply of Consumer Service Cable |
2 | Supply of Armored service cable for consumer service connection with all accessories including GI pipe/ MS angle as per technical specifications, scope of works and approved drawings |
3 | Supply of Single Phase armored AL cable size 2CX 6 Sq mm |
4 | Supply of Three Phase armored AL cable size 4CX 16 Sq mm |
5 | Supply of 10 SWG GI wire |
6 | Supply of 8 SWG GI wire |
7 | Conversion of existing LT lines on bare conductor to Areal bunch XLPE cable |
8 | Conversion of existing LT lines with bare conductor to AB XLPE cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings |
9 | Supply of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) |
10 | Galvanized Stay Set for LT line with anchor plate (200x200x6mm), 50x8mm stay clamp, 01 no. Stay guy insulator, nut bolts, 1 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work. |
11 | Conversion of existing LT lines using new Earthing as per approved drawings, technical specifications and scope of work |
12 | Supply of Spike Earthing made of 20mm X 2500 mm GI solid Rod |
13 | Supply of 8 SWG GI wire for earthing and guarding |
14 | Supply of following LT AB XLPE Cable for Conversion of existing LT bare conductor line with AB XLPE Cable as required as per technical specification, approved drawings and scope of work: |
15 | Supply of Aerial bunchedXLPE cable 3 X 50 sqmm+1x35 sqmm.(bare messenger wire)+1x16 sqmm. |
16 | Supply of Aerial bunchedXLPE cable 3 X 70 sqmm.+1x50 sqmm.(Bare messenger wire)+1x16 sqmm. |
17 | Supply of Aerial bunchedXLPE cable 3 X 95 sqmm.+1x70 sqmm.( bare messenger wire)+ 1x16 sqmm. |
18 | Supply of Aerial bunchedXLPE cable 3 X 120 sqmm. + 1x95 sqmm.(bare messenger wire) +1x16 sqmm. |
19 | Supply of Pole mounted LT Distribution box as per approved drawings, technical specifications and scope of work |
20 | Supply of Three phase SMC Distribution box with clamps |
21 | Supply of Single phase SMC Distribution box with clamps |
22 | Supply of XLPE insulated Al. cable for energisation of distribution box/ Kiosk as per approved drawings, technical specifications and scope of work |
23 | Supply of 1x25 mm2 XLPE insulated Al.cable |
24 | Supply of Stone pad (300x300x75) |
25 | Supply of Accessories for AB XLPE Cable as per approved drawings, technical specifications and scope of work |
26 | Stainless steel Strap |
27 | HDG LT Pole Clamp with nut & bolt for laying ABC |
28 | Dead end Clamp with I-Hook( Insulated) |
29 | Suspension Clamp with I-Hook ( Insulated) |
30 | 95/35 Sqmm - 70/25 sqmm PG Clamps( for line to line jumpering & energizing DB neutral) |
31 | 120/50 Sqmm - 95/25 sqmm PG Clamps( for line to line jumpering & energizing DB neutral) |
32 | LT Insulation piercing connector 120-50 sqmm - 50-25 sqmm size (for energizing distribution box) |
33 | LT Insulation piercing connector 120-50 sqmm - 120-50 sqmm size (for line to line jumpering) |
34 | LT Insulation piercing connector 16 - 25sqmmsize suitable for street light connection |
35 | Pre-Insulated Compression connectors size 16 sqmm suitable for AB XLPE cable |
36 | Pre-Insulated Compression connectors size 50 sqmm suitable for AB XLPE cable |
37 | Pre-Insulated Compression connectors size 70 sqmm suitable for AB XLPE cable |
38 | Pre-Insulated Compression connectors size 95 sqmm suitable for AB XLPE cable |
39 | Pre-Insulated Compression connectors size 120 sqmm suitable for AB XLPE cable |
40 | Heat shrinkable type end cap for AB XLPE cable |
41 | Supply for Augmentation of lines |
42 | Supply for Augmentation of 33 KV Line |
43 | Supply for Augmentation of 3 phase 33 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings |
44 | Supply of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) |
45 | Supply New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. |
46 | Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. |
47 | Supply of Pole accessories as per technical specification, approved drawing and scope of work |
48 | Supply of 33 KV danger board |
49 | Supply of GI Barbed wire 12 SWG |
50 | Supply for Augmentation of 3 phase 33 kV line replacing existing conductor with following type of new ACSR conductor including jointing sleeves, binding material, aluminum tape and helical Preformed fittings etc as required as per technical specification, approved drawings and scope of work. |
51 | Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog replacing existing racoon conductor |
52 | Supply of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther replacing existing dog/racoon conductor |
53 | Supply of 33 KV Under ground cable as per technical specification, approved drawings and scope of work. |
54 | Supply of 3CX300 Sqmm 33 KV XLPE Armored Cable |
55 | Supply of Accessories for 33 KV3Cx300 Sqmm XLPE Armored Cable (2 Nos including one spare)like 160mm dia HDPE pipes for road crossing and 150 mm dia GI pipegrade B for pole support outdoor heat shrinkable cable jointing kits, Lugs,CablePath markers, bi metallic clamps and 7/20 GI wireas per technical specification, approved drawing and scope of work |
56 | Supplyof new Insulator and hardware for Augmentation of33 kV line as per technical specification, approved drawings and scope of work |
57 | Supply of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings |
58 | Supply of 33 KV 10 KN Polymer Pin Insulators |
59 | Supply of new Earthing arrangement for Augmentation of33 kV line as per technical specifications,approved drawings and scope of work. |
60 | 8 SWG GI Coil 115 turns (1.85 kg) |
61 | Supply of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 02 no. guy insulator, anchor plate (300x300x8mm) , nut bolts, 01 No. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. |
62 | Supply of new GI wire for earthing and guarding for Augmentation of33 kV line as per technical specification, approved drawings and scope of work. |
63 | Supply of 6 SWG GI wire |
64 | Supply of 8 SWG GI wire |
65 | Supply of Conductor accessories as per technical specification, approved drawing and scope of work |
66 | Supply of PG Clamp for Dog to Dog conductor |
67 | Supply of PG Clamp for Panther to Panther conductor |
68 | Supply for Augmentation of 11 KV lines |
69 | Supply for Augmentation of 3 phase 11 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings |
70 | Supply of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) |
71 | Supply for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension channel with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. |
72 | Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. |
73 | Supply of Pole accessories as per technical specification, approved drawing and scope of work |
74 | Supply of 11 KV danger board |
75 | Stone Pad(300x300x75mm) |
76 | Supply of GI Barbed wire 12 SWG |
77 | Supply for Augmentation of 3 phase 11 kV line replacing existing conductor with following type of new ACSR conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. |
78 | Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel by replacing existing weasel/squirrel conductor |
79 | Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor |
80 | Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor |
81 | Supply for Augmentation of 3 phase 11 kV line using new Insulator and hardware as per technical specification, approved drawings and scope of work |
82 | Supply of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings |
83 | Supply of 11 KV 5 KN Polymer Pin Insulators |
84 | Supply for Augmentation of 3 phase 11 kV line using new Earthing arrangement as per technical specifications,approved drawings and scope of work. |
85 | Supply of GI Earthing spike made of 20x2500mm solid Rod |
86 | Supply for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 01 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 No turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. |
87 | Supply for Augmentation of 3 phase 11 kV line using new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work. |
88 | Supply of 6 SWG GI wire |
89 | Supply of 8 SWG GI wire |
90 | Supply of Conductor accessories as per technical specification, approved drawing and scope of work |
91 | Supply of PG Clamp for Weasel to Weasel conductor |
92 | Supply of PG Clamp for Dog to Dog conductor |
93 | Supply of PG Clamp for Rabbit to Rabbit conductor |
94 | Installation of DT Capacitor |
95 | Supply of DT Capacitor with Fitting as per Technical Specification, Approved Drawing and scope of work |
96 | Supply of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65 |
97 | Supply of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65 |
98 | Supply of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65 |
99 | Erection Part |
100 | Installation of Consumer Service Cable |
101 | Installation of Armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings |
102 | Installation of Single Phase armored AL cable size 2CX 6 Sq mm |
103 | Installation of Three Phase armored AL cable size 4CX 16 Sq mm |
104 | GI Wire 8 SWG |
105 | GI Wire 10 SWG |
106 | Erection for Conversion of existing LT lines on bare conductor to Aerial bunch XLPE cable |
107 | Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil of following pole as per scope of work, approved drawings and specifications: |
108 | 8.5 m/180 kgs PCC Poles - (PCC Pole as per state practice) |
109 | Erection of following types of poles for LT overhead line with Stone pad,pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: |
110 | Erection of 8.5 m/180 Kgs PCC Poles with base stone Pad as required - (state practices of PCC pole and stone Pad to be used) |
111 | Excavation of LT stay pit in following type of soils,as per scope of work, approved drawings and specifications: |
112 | Normal soil |
113 | Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire,Guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) with all accessories as per technical specifications, approved drawings and scope of works. |
114 | Removal of existing LT bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched XLPE cable, Fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, Pre- insulated compression connectors, 16 mm dia MS nuts & bolts, pole clamps, stainless steel strap, Single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm XLPE cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: |
115 | Erection of Aerial Bunched XLPE Cable3 X 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm |
116 | Erection of Aerial Bunched XLPE Cable 3 X 70 sqmm +1x50 sqmm ( bare messenger cum neutral )+1x16 sqmm |
117 | Erection of Aerial Bunched XLPE Cable 3 X 95 sqmm +1x70 sqmm ( bare messenger cum neutral )+ 1x16 sqmm |
118 | Erection of Aerial Bunched XLPE Cable 3 X 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm |
119 | Erection, testing & commissioning of earthing by inserting GI Earthing spike made of 20mm solid Rod as per approved drawings, scope of work and technical specifications |
120 | Erection of 8 SWG GI wire for earthing by providing GI nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications |
121 | Erection for Augmentation of lines |
122 | Erection for Augmentation of 33 KV Line |
123 | Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications: |
124 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) |
125 | Erection of following types of additional poles matching with existing line supports by installing danger plate, anti-climbing devices (barbed wire),Painting with red oxide & aluminum paint including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: |
126 | 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) |
127 | Excavation of stay pit for 33 KV Stay in following type of soils,as per scope of work, approved drawings and specifications: |
128 | Normal soil |
129 | Erection of complete stay set with GI stay wire (7x4.00 mm dia), binding of stay wire, Guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) with all accessories as per technical specifications, approved drawings and scope of works. |
130 | Erection, testing and commissioning of 33 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. |
131 | Erection of 33 kV 10 KN Pin insulator with GI pin |
132 | Erection of 33 kV 70 KN Disc insulator with strain hardware (set of 3, 11 KV disc insulators) |
133 | Erection, testing & commissioning of new Pre-fabricated HDG steel items like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. |
134 | Dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employer"s store and laying out & stringing of new ACSR conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. |
135 | Stringing of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog replacing existing racoon conductor |
136 | Stringing of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther replacing existing dog/racoon conductor |
137 | Erection, testing & commissioning of 33 KVunder ground Cable by2 Nos (including one spare) 3Cx300 Sqmm XLPE Armored Cable, using 160 mm HDPE pipe at road crossing, 150mm dia GI pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering and 7/20 GI wire etc as required as per technical specifications, approved drawings and scope of he work. |
138 | Erection for Augmentation of 3 phase 33 kV line using new Insulator and hardware as per technical specification, approved drawings and scope of work |
139 | Erection of 33 KV 70 KN polymer Disc insulator along with suitable hardware fittings |
140 | Erection of 33 KV 10 KN Polymer Pin Insulators |
141 | Erection, testing & commissioning of earthing as per technical specifications,approved drawings and scope of work. |
142 | 8 SWG GI Coil 115 turns (1.85 kg) |
143 | Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work. |
144 | Erection of 6 SWG GI wire |
145 | Erection of 8 SWG GI wire |
146 | Erection for Augmentation of 11 KV lines |
147 | Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications: |
148 | 8.5 m/180 kgs PCC Poles - (PCC Pole as per state practice) |
149 | Erection of following types of poles for 11 KV overhead line by installing danger plate, anti-climbing devices (barbed wire),pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: |
150 | Erection of 8.5 m/180 Kgs PCC Poles withBase stone pad(state practices of PCC pole and base plate/stone to be used) |
151 | Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications: |
152 | Normal soil |
153 | Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, Guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) with all accessories as per technical specifications, approved drawings and scope of works. |
154 | Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. |
155 | Erection of 11 kV Pin insulator with GI pin |
156 | Erection of 11 kV Disc insulator with strain hardware |
157 | Dismantling of existing overhead line conductor & fittings and depositing to Employer"s store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications |
158 | Stringing of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel by replacing existing weasel/squirrel conductor |
159 | Stringing of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor |
160 | Stringing of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor |
161 | Erection, testing & commissioning of pre-fabricated HDG steel items like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and HDG MS nuts, bolts & washers as per technical specification, approved drawings and scope of work. |
162 | Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. |
163 | Erection of 5 KN 11 kV Polymer Pin insulator |
164 | Erection of 45 KN 11 kV Polymer Disc insulator with strain hardware |
165 | Earthingand guarding arrangement as per technical specifications,approved drawings and scope of work. |
166 | Erection, testing & commissioning of Spike Earthing 20mm solid Rod |
167 | Erection of 8 SWG GI wire for earthing and guarding |
168 | Erection of 6 SWG GI wire for earthing and guarding |
169 | Erection of DT Capacitor |
170 | Erection, Testing & Commissioning offollowing 440 Volt LT shunt Capacitor including mounting Structure and accessories as required as per technical specifications,approved drawings and scope of work. |
171 | Erection of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65 |
172 | Erection of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65 |
173 | Erection of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65 |
174 | Words |