| 1 | 9.22.3-SHEET ROOFING Providing corrugat:-0.63 mm thick with zinc coating not less than 275 gm/ m²ed G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required:-0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 2 | 6.1.2-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: -1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 3 | 34.49-Painting Two Coats on New Concrete Surfaces:- Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces |
| 4 | 10.63.2-Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar |
| 5 | 11.5.3-12 mm cement plaster of mix :- 1:4 (1 cement: 4 fine sand) |
| 6 | 13.30.1-Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete:-Hot finished welded type tubes |
| 7 | 13.33-Providing and fixing M.S. rivets of sizes in position. |
| 8 | 5.25-Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 mettre lead as per directtion of Engineer - in charge:- |
| 9 | 6.14.1- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 10 | 6.33.3-J. STEEL REINFORCEMENT Steel reinforcement for R.C.C. workWhere not included in the complete rate of RCC, including straightering, cutting, bending, placind in position, binding, wastage, overlaps, welded, joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect belowplinth level.Note :- Reinforcement shall be measured in length including hooks, if any separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, weded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Cold twisted bars |
| 11 | 7.22.1-B. BRICK WORK:- Brick work with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in :- Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 12 | 11.59-Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |