Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Items : |
| 2 | Dismantling &shiftingofwindowair conditioningunit1.0TR/1.5TR/2TRcapacity excludingfasciaandcutting,weldingcomplete work as required within town. |
| 3 | Dismantling &shifting, installation, testing & commissioning of split air conditioning unit 1.0TR/1.5TR/2TRcapacity including indoor /outdoor unit complete as required within town. |
| 4 | Supply, installation, testing & commissioning of suction/dischargecopperpipelineinsplitair conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity includingbrazing,nitrilerubberinsulation 6/9mm thick class \"O\", etc complete as required-Copper tube 1/4\" |
| 5 | Supply, installation, testing & commissioning of suction/dischargecopperpipelineinsplitair conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity includingbrazing,nitrilerubberinsulation 6/9mm thick class \"O\", etc complete as required-Copper tube 3/8\" |
| 6 | Supply, installation, testing & commissioning of suction/dischargecopperpipelineinsplitair conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity includingbrazing,nitrilerubberinsulation 6/9mm thick class \"O\", etc complete as required-Copper tube 1/2\" |
| 7 | Supply, installation, testing & commissioning of suction/dischargecopperpipelineinsplitair conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity includingbrazing,nitrilerubberinsulation 6/9mm thick class \"O\", etc complete as required-Copper tube 5/8\" |
| 8 | Chemical servicing of window/split air conditioning unit 1TR/1.5TR/2TR/3TRcapacity including cleaningofcooling&condensing units, filters, grills etc & all otherparts oiling & greasing of fan motor, testing of A.C unit etc. |
| 9 | Gascharging(R410A/EcoFriendly GreenGas) ofwindow/splitairconditioningunitincluding flushingofcooling&condensingunitswith nitrogengas&rectificationofleakage, replacement of filter, flair nut etc. if any. 1.0 TR |
| 10 | Gascharging(R410A/EcoFriendly GreenGas) ofwindow/splitairconditioningunitincluding flushingofcooling&condensingunitswith nitrogengas&rectificationofleakage, replacement of filter, flair nut etc. if any. 1.5 TR |
| 11 | Gascharging(R410A/EcoFriendly GreenGas) ofwindow/splitairconditioningunitincluding flushingofcooling&condensingunitswith nitrogengas&rectificationofleakage, replacement of filter, flair nut etc. if any. 2.0 TR |
| 12 | Gascharging(R410A/EcoFriendly GreenGas) ofwindow/splitairconditioningunitincluding flushingofcooling&condensingunitswith nitrogengas&rectificationofleakage, replacement of filter, flair nut etc. if any. 3.0 TR |
| 13 | Gas charging of refrigerator upto 300 ltr capacity including flushingofcooling&condensing units with nitrogen gas & rectification ofleakage, replacement of filter, etc. if any. |
| 14 | Replacement & connection of thermostat switch of required size & capacity for Refrigerator upto 300 ltr capacity including all required material tocomplete the job. |
| 15 | Replacement & connection of starting relay requiredsize&capacityforRefrigeratorupto 300 ltr capacity including all required material to complete the job. |
| 16 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Window type air conditioners :- 1.5 TR |
| 17 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any.Splittypewallmountedairconditionerssinglephase 1.5 TR |
| 18 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Splittypewallmountedairconditionerssinglephase 2 TR |
| 19 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Splittypecassette/floortypeairconditioners single/three phase 1.5 TR |
| 20 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Splittypecassette/floortypeairconditioners single/three phase 2 TR |
| 21 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Splittypecassette/floortypeairconditioners single/three phase 3 TR |
| 22 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Ductable air conditioners three phase 5.5 TR |
| 23 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Ductable air conditioners three phase 7.5 TR |
| 24 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Ductable air conditioners three phase 8.5 TR |
| 25 | Comprehensivemaintenanceandservicingof air-conditionersoffollowingtypeandcapacity including replacement with new compressor, and related parts such as capacitors, relay, electronic controls,PCB,display,thermostat,remote control,andrelatedaccessories,rewindingof fan/blowermotor,flushingofcooling& condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage,replacementoffilter,flairnutetc.if any. Ductable air conditioners three phase 8.75 TR |
| 26 | Comprehensive maintenance of single/double door refrigerator upto 300 ltr capacity including replacementofcompressor,andrelatedparts suchascondenser,relay, electronic controls, display, thermostat, and related accessories, rewinding of motor, flushing of cooling & condensing units with nitrogen gas, required refrigerant gas charging & rectification of leakage, replacement of lamp, etc. if any. |
| 27 | Rewiringinexistingsurface/concealedrigid steel/PVC nonmetallic conduit with PVC insulated cable with copper multi strand conductor FRLS of ISI marked and other materials as required including replacement of wornout/damaged/missing material, painting etc.completeasperspecification.Thisshall include all work, arrangement required for wiringbutshallexcludeswitch,ceilingrose, fitting etc. |
| 28 | Rewiringinexistingsurface/concealedrigid steel/PVC nonmetallic conduit with PVC insulated cable with copper multi strand conductor FRLS of ISI marked and other materials as required including replacement of wornout/damaged/missing material, painting etc.completeasperspecification.Thisshall include all work, arrangement required for wiringbutshallexcludeswitch,ceilingrose, fitting etc. Light/fan/3 Pin6 Amp socket outlet on separate board/call bell/buzzer points:- Short point |
| 29 | Rewiringinexistingsurface/concealedrigid steel/PVC nonmetallic conduit with PVC insulated cable with copper multi strand conductor FRLS of ISI marked and other materials as required including replacement of wornout/damaged/missing material, painting etc.completeasperspecification.Thisshall include all work, arrangement required for wiringbutshallexcludeswitch,ceilingrose, fitting etc.Light/fan/3 Pin6 Amp socket outlet on separate board/call bell/buzzer points:- Medium point |
| 30 | Rewiringinexistingsurface/concealedrigid steel/PVC nonmetallic conduit with PVC insulated cable with copper multi strand conductor FRLS of ISI marked and other materials as required including replacement of wornout/damaged/missing material, painting etc.completeasperspecification.Thisshall include all work, arrangement required for wiringbutshallexcludeswitch,ceilingrose, fitting etc. Light/fan/3 Pin6 Amp socket outlet on separate board/call bell/buzzer points:- Long point |
| 31 | Rewiringinexistingsurface/concealedrigid steel/PVC nonmetallic conduit with PVC insulated cable with copper multi strand conductor FRLS of ISI marked and other materials as required including replacement of wornout/damaged/missing material, painting etc.completeasperspecification.Thisshall include all work, arrangement required for wiringbutshallexcludeswitch,ceilingrose, fitting etc. Twin control light point :- Short point |
| 32 | Rewiringinexistingsurface/concealedrigid steel/PVC nonmetallic conduit with PVC insulated cable with copper multi strand conductor FRLS of ISI marked and other materials as required including replacement of wornout/damaged/missing material, painting etc.completeasperspecification.Thisshall include all work, arrangement required for wiringbutshallexcludeswitch,ceilingrose, fitting etc. Twin control light point :- Medium point |
| 33 | Rewiringinexistingsurface/concealedrigid steel/PVC nonmetallic conduit with PVC insulated cable with copper multi strand conductor FRLS of ISI marked and other materials as required including replacement of wornout/damaged/missing material, painting etc.completeasperspecification.Thisshall include all work, arrangement required for wiringbutshallexcludeswitch,ceilingrose, fitting etc. Twin control light point :- Long point |
| 34 | Circuit wiring 2 X 1.5 sq. mm. |
| 35 | Circuit wiring 2 X 2.5 sq. mm. |
| 36 | 3 Pin 6 Amp socket outlet point on same board |
| 37 | 2Wire sub main:- 2 X 2.5 sq. mm. |
| 38 | 2Wire sub main:- 2 X 4.00 sq. mm. |
| 39 | 2Wire sub main:- 2 X 6.00 sq. mm. |
| 40 | 2Wire sub main:- 2 X 10.0sq. mm. |
| 41 | 2Wire sub main:- 2 X 16.00 sq. mm. |
| 42 | 3Wire sub main:- 3 X 2.5 sq. mm. |
| 43 | 3Wire sub main:- 3 X 4.00 sq. mm. |
| 44 | 3Wire sub main:- 3 X 6.00 sq. mm. |
| 45 | 3Wire sub main:- 3 X 10.0sq. mm. |
| 46 | 3Wire sub main:- 3 X 16.00 sq. mm. |
| 47 | 3Wire sub main:- 3 X 25.00 sq. mm. |
| 48 | 3Wire sub main:- 3 X 35.00 sq. mm. |
| 49 | 3 1/2 Wire sub main:- 3 x 2.5 + 1 x 1.5 sq. mm. |
| 50 | 3 1/2 Wire sub main:- 3 x 4.0 + 1 x 2.5 sq. mm. |
| 51 | 3 1/2 Wire sub main:- 3 x 6.0 + 1 x 4.0 sq. mm. |
| 52 | 3 1/2 Wire sub main:- 3 x 10.0 + 1 x 6.0 sq. mm. |
| 53 | 3 1/2 Wire sub main:- 3 x 16.0 + 1 x 10.0 sq. mm. |
| 54 | 3 1/2 Wire sub main:- 3 x 25.0 + 1 x 16.0 sq. mm. |
| 55 | 3 1/2 Wire sub main:- 3 x 35.0 + 1 x 16.0 sq. mm. |
| 56 | 4Wire sub main:- 4 X 2.5 sq. mm. |
| 57 | 4Wire sub main:- 4 X 4.0 sq. mm. |
| 58 | 4Wire sub main:- 4 X 6.0 sq. mm. |
| 59 | 4Wire sub main:- 4 X 10.0 sq. mm. |
| 60 | 4Wire sub main:- 4 X 16.0 sq. mm. |
| 61 | 4Wire sub main:- 4 X 25.0 sq. mm. |
| 62 | 4Wire sub main:- 4 X 35.0 sq. mm. |
| 63 | Supply of ISI marked and accepted standard ofminiaturecircuitbreaker(MCB)of\"C\" serieswithshortcircuitindication,suitable for 240/415Volts,50Cycle,10kA/15kA Value AC supply conforming to IS : 8828 : 1996,IEC:60898:2002&60947-2but without enclosures :- Single pole:- MCB SP 6Amp to 32Amp 10kA rating |
| 64 | Supply of ISI marked and accepted standard ofminiaturecircuitbreaker(MCB)of\"C\" serieswithshortcircuitindication,suitable for 240/415Volts,50Cycle,10kA/15kA Value AC supply conforming to IS : 8828 : 1996,IEC:60898:2002&60947-2but without enclosures :- SPN:- MCB DP 6Amp to 32Amp 10kA rating |
| 65 | Supply of ISI marked and accepted standard ofminiaturecircuitbreaker(MCB)of\"C\" serieswithshortcircuitindication,suitable for 240/415Volts,50Cycle,10kA/15kA Value AC supply conforming to IS : 8828 : 1996,IEC:60898:2002&60947-2but without enclosures :- TPN:- 63 Amperes 10kA rating |
| 66 | Fixing of MCB/MCCB/Isolator in sheet steel enclosureasrequiredasperaccepted practice,includingmountingonbusbarand cable connection etc. complete (labour only) MCB/Isolator SP/DP |
| 67 | Fixing of MCB/MCCB/Isolator in sheet steel enclosureasrequiredasperaccepted practice,includingmountingonbusbarand cable connection etc. complete (labour only) MCB/MCCBIsolator TP/TPN/FP |
| 68 | Dismantlingofexistinglight/fan/ bell/socketoutletpointonseparate board/wiringandcircuitwith insulatedwireincasing/conduit/ battencompletewithfitting and accessories |
| 69 | Makingthesiteclearofthe dismantled installation by refilling the holewithcementmortar&finished withpaintgittiesand replacingtomatch the colour& wall ceiling. |
| 70 | Dismantling ofexisting socket outlet point on same board in any system of wiring |
| 71 | Dismantlingtheexisting armoured/unarmouredcableor2/3/4 wires of submain, main, in any system of wiring including recoiling. |
| 72 | Dismantlingofexistingunderground cablesafelywithitsaccessoriesand refillingthetrenchtogroundlevel includingrecoilingofdismantledcable. |
| 73 | Dismantling of D.F.board, D.P. switch, T.P. & T.P.N. switch or D.B. ofanysizecompletewithboardor angle/flat iron frame and making site clearincludingtherefillinghole& repainting to match colour of wall. |
| 74 | Dismantling of D.F. board, D.P.switch, T.P. & T.P.N. switch or D.B. of any size only |
| 75 | Dismantlingtheexisting ceiling/exhaust/cabin fan with complete accessories and making thesite clear. |
| 76 | Dismantling of existing geyser or storage type water heater and making thesitegoodbycolourwashetc.asrequired. |
| 77 | Providingrecessinbrickwall suitable for erecting of exhaust fan up to 450 sweep complete with grouting ofnutbolts,plasteringandcolour wash to match the colour of wall.For wall thickness upto 9\" |
| 78 | Providingrecessinbrickwall suitable for erecting of exhaust fan up to 450 sweep complete with grouting ofnutbolts,plasteringandcolour wash to match the colour of wall.For wall thickness upto 15\" |
| 79 | Providingrecessinbrickwall suitable for erecting of exhaust fan up to 450 sweep complete with grouting ofnutbolts,plasteringandcolour wash to match the colour of wall.For the stone wall thickness upto 15\" |
| 80 | Supplying,erection andtesting ofapproved makeelectricCeilingfanofdoubleball bearingcompletewithstandarddownrod, canopy, hanging shackle, Aluminium blades, withoutregulator,A.C.230-250volts includingconnections withallnecessary materialcompleteofapprovedasrequired confirmingtoIS:374/2019withuptodateamendments.:- Ceiling fan - 900 mm sweep |
| 81 | Supplying,erection andtesting ofapproved makeelectricCeilingfanofdoubleball bearingcompletewithstandarddownrod, canopy, hanging shackle, Aluminium blades, withoutregulator,A.C.230-250volts includingconnections withallnecessary materialcompleteofapprovedasrequired confirmingtoIS:374/2019withuptodateamendments.:- CeilingFan(ISImarked)-1200mmSweep, with minimum air delivery 210m³/min andservice value = 4.00 as per BEE.. |
| 82 | Supplying,erection andtesting ofapproved makeelectricCeilingfanofdoubleball bearingcompletewithstandarddownrod, canopy, hanging shackle, Aluminium blades, withoutregulator,A.C.230-250volts includingconnections withallnecessary materialcompleteofapprovedasrequired confirmingtoIS:374/2019withuptodateamendments.:- Ceiling Fan ( ISI marked )-1400 mm Sweep, minimum air delivery 245 m³/min andservice value = 4.10 as per BEE. |
| 83 | Supplying,erection andtesting ofapproved makeelectricCeilingfanofdoubleball bearingcompletewithstandarddownrod, canopy, hanging shackle, Aluminium blades, withoutregulator,A.C.230-250volts includingconnections withallnecessary materialcompleteofapprovedasrequired confirmingtoIS:374/2019withuptodateamendments.:- CeilingFanOrnamental1200mmSweep, with minimum air delivery 210m³/min andservice value = 4.00 as per BEE. |
| 84 | Supplying,erection andtesting ofapproved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and includingrawbolt/anchorholefasteneretc.complete finished and as required:- 300 mm sweep |
| 85 | Supplying,erection andtesting ofapproved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and includingrawbolt/anchorholefasteneretc.complete finished and as required.:- 400 mm sweep |
| 86 | Supplying,erection andtesting ofapproved makecabinfanoscillatingtypewithbase, blades,guard, speedregulator etc.AC 230-250voltswithconnectionsandincluding rawbolt/anchorholefasteneretc.complete finished and as required.:- 300 mm sweep |
| 87 | Supplying,erection andtesting ofapproved make \"Fresh air fan\" AC230-250 volts with connectionandincludingframebolt/anchor hole fastenersetc.complete finishedandasrequired.:- 150 mm sweep bush type |
| 88 | Supplying,erection andtesting ofapproved make \"Fresh air fan\" AC230-250 volts with connectionandincludingframebolt/anchor hole fastenersetc.complete finishedandasrequired.:- 225 mm sweep bush type |
| 89 | Supplying,erection andtesting ofapproved make \"Fresh air fan\" AC230-250 volts with connectionandincludingframebolt/anchor hole fastenersetc.complete finishedandasrequired.:- 300 mm sweep bush type |
| 90 | Supplying,erection andtesting ofapproved make \"Fresh air fan\" AC230-250 volts with connectionandincludingframebolt/anchor hole fastenersetc.complete finishedandasrequired.:- 225 mm sweep double ball bearing |
| 91 | Supplying,erection andtesting ofapproved make \"Fresh air fan\" AC230-250 volts with connectionandincludingframebolt/anchor hole fastenersetc.complete finishedandasrequired.:- 300 mm sweep double ball bearing |
| 92 | Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self- closinglouversofdecorativePVCblades mountingsquareframeofapproved make complete with all necessary material asrequired:- 150mm RPM1300/1400 |
| 93 | Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self- closinglouversofdecorativePVCblades mountingsquareframeofapproved make complete with all necessary material asrequired:- 200mm RPM1300/1400 |
| 94 | Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self- closinglouversofdecorativePVCblades mountingsquareframeofapproved make complete with all necessary material asrequired:- 250mm RPM1300/1400 |
| 95 | Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self- closinglouversofdecorativePVCblades mountingsquareframeofapproved make complete with all necessary material asrequired:- 300mm RPM1300/1400 |
| 96 | Supplying,erecting andtesting ofapproved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fastenersetc.complete finishedandasrequired.:- 300mm sweepRPM 900 / 1400 |
| 97 | Supplying,erecting andtesting ofapproved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fastenersetc.complete finishedandasrequired.:- 380mm sweepRPM 900 /1400 |
| 98 | Supplying,erecting andtesting ofapproved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fastenersetc.complete finishedandasrequired.:- 450mm sweepRPM 900 / 1400 |
| 99 | Supplying,erecting andtesting ofapproved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fastenersetc.complete finishedandasrequired.:- 600mm sweepRPM 900 |
| 100 | Supplying, installation/fixing, and testing of approvedmakeexhaust/freshAirinlinefan Ac 220-240V, 50 Hz size 150mm (6 inches) 23-25wattsincludingframebolt/anchor hole fastners etc.having fully copper winding motor, silent operation and delightfulaestheticscompleteincluding connections.:- 150mm (white) |
| 101 | Supplying, installation/fixing, and testing of approvedmakeexhaust/freshAirinlinefan Ac 220-240V, 50 Hz size 150mm (6 inches) 23-25wattsincludingframebolt/anchor hole fastners etc.having fully copper winding motor, silent operation and delightfulaestheticscompleteincluding connections.:- 150mm (SS Finished) |
| 102 | Supplying and testing of approved make Pedestal fanA.C. 230-250 volts with blades speed regulator \"pedestal etc duly wired with all necessary material complete as required:- 400 mm Sweep |
| 103 | Supplying and replacement of cooler fan 500 mm(20\")ISImarkedwithallnecessary materialincludingconnectioncompleteof approved as required |
| 104 | Supply and replacement of ISI marked cooler submersible water pump complete withallnecessarymaterialincludingconnection of approved make as required |
| 105 | Supplyingandfixingofcooler/A.C.M.S. angle iron stand including flat iron supports, groutinginwallifrequired,welding, |
| 106 | Supply andfixingM.S.downrod14SWG (2mm)thickforceilingfanincluding threading, painting, making holes etc. as required complete.Note:For new works difference of installed & standard down rod length shall be paid. |
| 107 | Cleaning, overhauling, servicing of ceiling/exhaust/wall bracket fan by applyinggrease&oil,includingtesting withmounting/hangingarrangement including replacementof safety pins, check nuts, lock nut, nut bolts etc. making perfectalignment&refittingatsiteas required. |
| 108 | Servicing & overhauling of cooler fan motor, pump including replacement of distribution,deliverypipes,PVCelbows, painting etc.as reqd. complete withnecessary material & labour. |
| 109 | Supply, fixing and testing of MPP condenser 440 Volt single phase of approved make as required as perspecification:- |
| 110 | Supply, fixing and testing of MPP condenser 440 Volt single phase of approved make as required as perspecification:- Condenser 2.5 mfd 440Volt |
| 111 | Supply, fixing and testing of MPP condenser 440 Volt single phase of approved make as required as perspecification:- Condenser 3.15 mfd440Volt |
| 112 | Supply andfixingLedtuberodcomprisingof LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life withminimum@L70,systemlumenoutput shouldbeminimumwithsystemefficacy>100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012),IEC60598,IEC61347i/cconnectionwire, testing etc. to complete the job. Tube light LED 1 X 8/10Watt Integral i/c batten aluminium body, PC diffuser. |
| 113 | Supply andfixingLedtuberodcomprisingof LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life withminimum@L70,systemlumenoutput shouldbeminimumwithsystemefficacy>100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012),IEC60598,IEC61347i/cconnectionwire, testing etc. to complete the job. TubelightLED1X12WattIntegrali/cbattenaluminium body, PC diffuser. |
| 114 | Supply andfixingLedtuberodcomprisingof LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life withminimum@L70,systemlumenoutput shouldbeminimumwithsystemefficacy>100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012),IEC60598,IEC61347i/cconnectionwire, testing etc. to complete the job. Tube light LED 1 X 18Watt,Integral i/c battenaluminium body, PC diffuser. |
| 115 | Supply andfixingLedtuberodcomprisingof LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life withminimum@L70,systemlumenoutput shouldbeminimumwithsystemefficacy>100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012),IEC60598,IEC61347i/cconnectionwire, testing etc. to complete the job. TubelightLED1X20/22Watt, Integrali/c batten aluminium body, PC diffuser. |
| 116 | Supply andfixingLedtuberodcomprisingof LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life withminimum@L70,systemlumenoutput shouldbeminimumwithsystemefficacy>100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012),IEC60598,IEC61347i/cconnectionwire, testing etc. to complete the job. LEDretrofitglasstubei/cdriveronly 20/22Watt,color temp 3000 - 6000K without box suitable for replacing existing 36/40Watt FTL |
| 117 | Supplyandfixingofrecessedmountingtype Ledlightfixture,LEDof1to3Watteach assembledonsingleMCPCB,having color temp upto 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LEDdriverPF>0.95,THD<20%&surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of CRCA powder coated frame with glare freediffusedpolycarbonatecover.Submission LM79-08/IS16106(2012),IEC60598,IEC61347 i/c connection wire, testing etc. to complete the job. LED luminiare 2\" X 2\", 36Watt, color temp 3000-6500k as required. |
| 118 | Supplyandfixingofrecessedmountingtype Ledlightfixture,LEDof1to3Watteach assembledonsingleMCPCB,having color temp upto 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LEDdriverPF>0.95,THD<20%&surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of CRCA powder coated frame with glare freediffusedpolycarbonatecover.Submission LM79-08/IS16106(2012),IEC60598,IEC61347 i/c connection wire, testing etc. to complete the job. LED luminiare 2\" X 2\", 45Watt, color temp 3000-6500k as required. |
| 119 | Supply and fixing of surface mounting type LED light fixture, LED of 1 to 3 Watt each assembled onsingleMCPCB,having colortempupto 6500K& having50000burninghrs.lifewith minimum @ L 70, system lumen output should beminimumwithefficacy>100lm/Watt.LED driver, PF> 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of CRCA powder coated frame with glare freediffusedpolycarbonatecover.Submission LM79-08/IS16106(2012),IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED luminiare 2\" X 2\", 36Watt, color temp 3000-6500k as required. |
| 120 | Supply and fixing of surface mounting type LED light fixture, LED of 1 to 3 Watt each assembled onsingleMCPCB,having colortempupto 6500K& having50000burninghrs.lifewith minimum @ L 70, system lumen output should beminimumwithefficacy>100lm/Watt.LED driver, PF> 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of CRCA powder coated frame with glare freediffusedpolycarbonatecover.Submission LM79-08/IS16106(2012),IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED luminiare 2\" X 2\", 45Watt, color temp 3000-6500k as required. |
| 121 | Supply and fixing recessed mounting LED down lighter,LED of 1to 3Watt eachassembled on single MCPCB, having color temp upto 6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 3 Watt, color temp 3000-6500k as required. |
| 122 | Supply and fixing recessed mounting LED down lighter,LED of 1to 3Watt eachassembled on single MCPCB, having color temp upto 6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.5/6 Watt, color temp 3000-6500k as required. |
| 123 | Supply and fixing recessed mounting LED down lighter,LED of 1to 3Watt eachassembled on single MCPCB, having color temp upto 6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 7/8 Watt, color temp 3000-6500k as required. |
| 124 | Supply and fixing recessed mounting LED down lighter,LED of 1to 3Watt eachassembled on single MCPCB, having color temp upto 6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 12 Watt, color temp 3000-6500k as required. |
| 125 | Supply and fixing recessed mounting LED down lighter,LED of 1to 3Watt eachassembled on single MCPCB, having color temp upto 6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 14/15 Watt, color temp 3000-6500k as required. |
| 126 | Supply and fixing recessed mounting LED down lighter,LED of 1to 3Watt eachassembled on single MCPCB, having color temp upto 6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 18/20Watt, color temp 3000-6500k as required. |
| 127 | Supply and fixing recessed mounting LED down lighter,LED of 1to 3Watt eachassembled on single MCPCB, having color temp upto 6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 22/24Watt, color temp 3000-6500k as required. |
| 128 | Supply and fixing surface mounting LED down lighter,LEDof1to3Watteachassembledon singleMCPCB,havingcolortempupto6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 3 Watt, color temp 3000-6500k as required. |
| 129 | Supply and fixing surface mounting LED down lighter,LEDof1to3Watteachassembledon singleMCPCB,havingcolortempupto6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 5/6 Watt, color temp 3000-6500k as required. |
| 130 | Supply and fixing surface mounting LED down lighter,LEDof1to3Watteachassembledon singleMCPCB,havingcolortempupto6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 7/8 Watt, color temp 3000-6500k as required. |
| 131 | Supply and fixing surface mounting LED down lighter,LEDof1to3Watteachassembledon singleMCPCB,havingcolortempupto6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 14/15 Watt, color temp 3000-6500k as required. |
| 132 | Supply and fixing surface mounting LED down lighter,LEDof1to3Watteachassembledon singleMCPCB,havingcolortempupto6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 18/20 Watt, color temp 3000-6500k as required. |
| 133 | Supply and fixing surface mounting LED down lighter,LEDof1to3Watteachassembledon singleMCPCB,havingcolortempupto6500K &having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection4KV.Thecolourrenderingindexof LEDlightshouldbemorethan70.Housing made of pressure die cast aluminium/CRCA powdercoatedframewithglarefreediffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 22/24Watt, color temp 3000-6500k as required. |
| 134 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor:- Armoured 4 core 10 sq. mm. |
| 135 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor:- Armoured 4 core 16 sq. mm. |
| 136 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor:- Armoured 4 core 25 sq. mm. |
| 137 | Laying of underground cable armoured./unarmouredasperspecification inairsuspendedonexistingapprovedtype of iron clamp, G.I wire 7/1.6mm & shackle insulator/insulated strip complete.:- 1/2/3/4 Core cable upto 16 sq. mm |
| 138 | Laying of underground cable armoured./unarmouredasperspecification inairsuspendedonexistingapprovedtype of iron clamp, G.I wire 7/1.6mm & shackle insulator/insulated strip complete.:- 1/2/3/3½/4 Core cable 25 sq. mm to 120 sq.mm |
| 139 | Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & providedwithrequiredgasketfor dust/verminproofwithdegreeof protectionIP42suitablefor415Volt3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mmfordoors)dulycompartmentalized for incomer, bus section, outgoings, cablealleys&CT,PTAmpereMetre, Volt Metre, selector switches, frequency Metre,phaseindicatinglamp,Energy Metre complete including cost of busbar supports,detachablecableglandplates, 2earthingterminals,internalwiring& fixing of separately supplied MCBs, MCCBs,ACB,panelmounted changeoverswitch/SFUs,etc.as requiredbutexcludingcostofbusbar strips,AmpereMetre,VoltMetre,selectorswitchasperapproveddesign |
| 140 | Removing of old paint from steel and other metallic surface and making surface even. |
| 141 | Prima coat over new steel and other metallic surface with red oxide zinc chromide paint complete with supply of material labour etc.including preparation of surface. |
| 142 | Primacoatwithaluminiumpaint,brushingcomplete with material and labour including preparation of surface |
| 143 | Supplying & fixing of Fire Extinguisher/Refills as per IS specification Dry chemical powder (DCP) type- 5kg duly refiled and ready to use |
| 144 | Supplying & fixing of Fire Extinguisher/Refills as per IS specification ABC type duly refield and ready to used |
| 145 | Supplying & fixing of Fire Extinguisher/Refills as per IS specification Co2 type dully refiled and ready to used |
| 146 | Supplying & fixing of Fire Extinguisher/Refills as per IS specification Dry chemical powder (DCP) type- 5kgrefile only |
| 147 | Supplying & fixing of Fire Extinguisher/Refills as per IS specification ABC type refill only |
| 148 | Supplying & fixing of Fire Extinguisher/Refills as per IS specification Co2 type Refill only |
| 149 | Supplying & fixing of Fire Extinguisher/Refills as per IS specification 4 bucket set with stand and sand dully painted red |
| 150 | Supplying of metal clad ISI marked busbar chambermadeofheavygaugeironsheet complete with copper strip and busbar supports asperspecificationconformingto IS -4064 200 Amp 415 VOLTS, 4 way |
| 151 | Supplying of metal clad ISI marked busbar chambermadeofheavygaugeironsheet complete with copper strip and busbar supports asperspecificationconformingto IS -4064 300 Amp 415 VOLTS, 4 way |
| 152 | Providing and fixing earthing arrangement with38.1mmdia2.5metrelong galvanized iron pipe electrode including packing of charcoal powder and salt as per specification watering pipe 19mm dia G.I. connection, cover plate having locking arrangement on the top etc. complete with refilling the pit as required, includingexcavation of earth pit in soil / soft rock |
| 153 | EarthingwithG.I.earthpipe4.5metre long and 40 mm dia with masonry encloserincementmortar,coverplate havinglockingarrangementonthetop etc.(butwithoutcharcoalorcokeandsalt) complete as required |
| 154 | Add extra for using salt and charcoal/coke for pipeearthelectrodeasrequired including excavation & refilling Excavation 4.5 m by manual labour |
| 155 | Add extra for using salt and charcoal/coke for pipeearthelectrodeasrequired including excavation & refilling Excavation by making hole with auger |
| 156 | Supply,installationtestingand commissioning RJ - 45 computer jack cat 6with shutter modular (1Module) |
| 157 | Supply,installationtestingand commissioning RJ - 45 computer jack cat 6with shutter modular (1Module) RJ - 45 computer socket cat 6 with shutter modular (1Module) |
| 158 | Supply,installationtestingand commissioning RJ - 45 computer jack cat 6with shutter modular (1Module) RJ-45computersocketcat6toolless connection (1Module) |
| 159 | Supply,fixingandtestingofT.V.outlet modular (1Module) |
| 160 | Supply, fixing and testingof RJ 11 telephone jack modular (1 Module) |
| 161 | Supplyingandinstallingdoublewall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at requireddepthupto90cm.below road/groundsurface,includingexcavation, backfillingwithexcavatedmaterial,ramming and making the surface good. 50.00mm outside dia. |
| 162 | Supplyandfixingasperspecification callbell/buzzerofapprovedmakewithnecessary materials complete. Ding dong bell |
| 163 | Supplying of approved make TPN MCB DB metaldoubledoorIP43protectionwith provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusiveofbusbar,neutralbar,earthbar, connection copper wire not less than 16 sq.mm&twoearthterminalsetc.complete asperIS:13032(exclusiveofMCB&isolator): 4 Way (4+12) |
| 164 | Supplying of approved make TPN MCB DB metaldoubledoorIP43protectionwith provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusiveofbusbar,neutralbar,earthbar, connection copper wire not less than 16 sq.mm&twoearthterminalsetc.complete asperIS:13032(exclusiveofMCB&isolator): 4 Way (8+12) |
| 165 | SupplyingandfixingPVCcasing and capping (double fold) ISI markedalongwithaccessorieson surface etc. as required PVCcasingandcapping(double fold) 20 mm x 12mm |
| 166 | SupplyingandfixingPVCcasing and capping (double fold) ISI markedalongwithaccessorieson surface etc. as required PVCcasingandcapping(double fold) 25 mm x 12mm |
| 167 | SupplyingandfixingPVCcasing and capping (double fold) ISI markedalongwithaccessorieson surface etc. as required PVCcasingandcapping(double fold) 32 mm x 12mm |
| 168 | SupplyingandfixingPVCcasing and capping (double fold) ISI markedalongwithaccessorieson surface etc. as required PVCcasingandcapping(double fold) 38 mm x 20mm |
| 169 | SupplyingandfixingPVCcasing and capping (double fold) ISI markedalongwithaccessorieson surface etc. as required PVCcasingandcapping(double fold) 50 mm x 16mm |
| 170 | Supply and fixing of PVC insulated copper flexible speaker wire twinFRLS 1100 Volts as per IS:694-1990 of approved make (24/0.2 mm) Twin core 0.75 sq.mm. |
| 171 | Supply and fixing of PVC insulated copper flexible speaker wire twinFRLS 1100 Volts as per IS:694-1990 of approved make (32/0.2 mm) Twin core 1.00 sq.mm. |
| 172 | Supply and fixing of PVC insulated copper flexible speaker wire twinFRLS 1100 Volts as per IS:694-1990 of approved make (30/0.25 mm) Twin core 1.50 sq.mm. |
| 173 | Supplyandfixingasperspecification SwitchofapprovedmakeISImarked with necessary material complete. 6/10Amp SP 250 Volt modular switch |
| 174 | Supplyandfixingasperspecification SwitchofapprovedmakeISImarked with necessary material complete. 16/20Amp SP 250 Volt modular switch |
| 175 | Supplyandfixingasperspecification socketoutlet ofapprovedmake&ISI markedwithnecessarymaterialcomplete 10Amp 250 Volt 3 Pin modular type |
| 176 | Supplyandfixingasperspecification socketoutlet ofapprovedmake&ISI markedwithnecessarymaterialcomplete 10/16/20Amp250Volt3Pinmodular type |
| 177 | Providingandfixing25mmX5mmG.I.striponsurfaceorinrecessedfor connection etc. as required |
| 178 | Sr. Electrician (Skilled) |
| 179 | Electricians/ Technicians (Skilled) |
| 180 | Fire Equipment Operator (Skilled) |
| 181 | Helper (Unskilled) |
| 182 | Designing and construction of footing foundationforoctagonalpoleofdesired size including excavation in soil/soft rock, baseconcreteM-7.5(1:4:8),15mmthick and pedestal of RCC M-20 (1:1.5:3), requiredtarsteelreinforcementfor required size from base concrete, shuttering,curingetc.withexisting foundation bolts complete as per specificationsinanapprovedmanneras permanufacturerdrawingorengineer-in- charge. |
| 183 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 44 mm O.D. wall thickness = 1.4mm (insulation– 19 mm thick) |
| 184 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 41.1mmO.D.wallthickness=1.4mm (insulation – 19 mm thick) |
| 185 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 38 mm O.D.wall thickness = 1.4mm (insulation– 19 mm thick) |
| 186 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 34.9mmO.D.wallthickness=1.4mm (insulation – 19 mm thick) |
| 187 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 28.6mmO.D.wallthickness=1.2mm (insulation – 19 mm thick) |
| 188 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 25 mm O.D.wall thickness = 1.2mm (insulation– 19 mm thick) |
| 189 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 22.2mmO.D.wallthickness=1.0mm (insulation – 19 mm thick) |
| 190 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 19.1mmO.D.wallthickness=1.0mm (insulation – 13 mm thick) |
| 191 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 15.9mmO.D.wallthickness=0.8mm (insulation – 13 mm thick) |
| 192 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 12.7mmO.D.wallthickness=0.8mm (insulation – 13 mm thick) |
| 193 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 9.5 mm O.D. wall thickness = 0.8mm (insulation– 13 mm thick) |
| 194 | Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerantpipework(19mm/13mmthick) duly insulatedwithelastomericnitrilerubbertype tubularinsulationbetween indoor &outdoor unitsasperspecifications.Andexposedpiping shouldbewrappedwithglasswovenclothand lag coating for vapour barrier and weather protection.Jointsshallbecoveredwithnitrile rubbertapeof3mmthickcompleteasperspecification. 6.4 mm O.D. wall thickness = 0.8mm (insulation– 13 mm thick) |
| 195 | Drainpiping:-ProvidingandfixingofCPVC, 6Kg/cm2 drain water piping with fittings, supportandinsulatedwith6mmthick closed cellelastomericnitrilerubberinsulation complete as per specification. 20 mm dia ID |
| 196 | Drainpiping:-ProvidingandfixingofCPVC, 6Kg/cm2 drain water piping with fittings, supportandinsulatedwith6mmthick closed cellelastomericnitrilerubber insulation complete as per specification. 25 mm dia ID |
| 197 | Drainpiping:-ProvidingandfixingofCPVC, 6Kg/cm2 drain water piping with fittings, supportandinsulatedwith6mmthick closed cellelastomericnitrilerubberinsulation complete as per specification. 32 mm dia ID |
| 198 | Drainpiping:-ProvidingandfixingofCPVC, 6Kg/cm2 drain water piping with fittings, supportandinsulatedwith6mmthick closed cellelastomericnitrilerubber insulation complete as per specification. 40 mm dia ID |
| 199 | Supplying of ISI Marked Automatic Transfer Switches (ATS) confirming to IEC:60947-1 & IEC:60947-6-1 with automatic in built time delay 4 pole, 415 V with two earthing terminals if required. 200 Amp (open execution ) |
| 200 | 3 Phase, 125 KVA, Water cooled Supply, installation, testing and commissioning of diesel generating set three phase, water cooled with AMF control panel, 125 KVA, 415V With electronic govermor. |
| 201 | maintenance and servicing of diesel generating set three phase, water cooled with AMF control panel, 125 KVA, 415V |
| 202 | Supply and fixing as per specification Coolant level in radiator and compensatorv tank |
| 203 | Supply and fixing as per specification Restriction indicator of dry type air cleaner / radiator |
| 204 | Supply and fixing as per specification Rubbber hose & clips of dry type air cleaner/ radiator |
| 205 | Supply and fixing as per specification Engine oil (every 500 hrs) |
| 206 | Lube oil filter cartridge (each 500 hrs) |
| 207 | Battery and load connection (every 50 hrs) |
| 208 | V belt connection and tension (adjust / replace) |
| 209 | Raidiator fins ( depends on site condition) |
| 210 | Raidiator tubes internally |
| 211 | Raplace fuel filter cartridge agter every 500 Hrs |
| 212 | Injector |
| 213 | Fuel strainer (button filter) |
| 214 | Themostat element (change if necessary) |
| 215 | Valve clearance (adjusted if necessary) |
| 216 | Starter/ alternator |
| 217 | Supply and fixing as per specification Fasteners |
| 218 | Supply and fixing as per specification Exhause silencer |
| 219 | UPS (1 phase inpur & 1 phase outpur) maintenance and servicing of UPS sith isolation transformer & battery for backup. Minimumload power factor 0.8, power factor 0.99. having OVCD (over voltage cut-off device), having CVCF ( constant voltage constant friquency, bypass parameters configurable, 2 stage charging ( constant current/ float charge), having temperature compensated charger, Fan speed control, digital signal processor controller, total harmonic distortion (current) - THDi (<10%@50%R Load, Input I phase voltage 230v, voltage range 110-300v, Output voltage (220AC/230AC/240AC + 1%), Total harmonic distortion Voltage (THDv- <3% linear load, <5% nonlinear load, 90% AC/AC efficiency, Over load capacity (105-110% 3min, 111-130%, 30sec), operating temperature with full load 0-40C, communication features (RS232. USB com port, Intelligent slot (optional), UPS installation with all required material arrangements as required as per IS specification.For 30 minute backup, min 800 VAH |
| 220 | UPS (1 phase inpur & 1 phase outpur) maintenance and servicing of UPS sith isolation transformer & battery for backup. Minimumload power factor 0.8, power factor 0.99. having OVCD (over voltage cut-off device), having CVCF ( constant voltage constant friquency, bypass parameters configurable, 2 stage charging ( constant current/ float charge), having temperature compensated charger, Fan speed control, digital signal processor controller, total harmonic distortion (current) - THDi (<10%@50%R Load, Input I phase voltage 230v, voltage range 110-300v, Output voltage (220AC/230AC/240AC + 1%), Total harmonic distortion Voltage (THDv- <3% linear load, <5% nonlinear load, 90% AC/AC efficiency, Over load capacity (105-110% 3min, 111-130%, 30sec), operating temperature with full load 0-40C, communication features (RS232. USB com port, Intelligent slot (optional), UPS installation with all required material arrangements as required as per IS specification.For 30 minute backup, min 800 VAH For 60 minute backup, min 1600 VAH |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy