Portable Detectors Portable Detectors For Ammonia, Chlorine And So2 , Portable Detector For Ammonia Intrinsically Safe Portable Gas Detector Designed For Monitoring The Presence Of Ammonia Vapours. The Device Shall Be Ergonomically Designed For Easy Use, udyogamandal-Kerala

Fertilisers And Chemicals Travancore Limited has published Portable Detectors Portable Detectors For Ammonia, Chlorine And So2 , Portable Detector For Ammonia Intrinsically Safe Portable Gas Detector Designed For Monitoring The Presence Of Ammonia Vapours. The Device Shall Be Ergonomically Designed For Easy Use. Submission Date for this Tender is 01-06-2022. Chemical Supply Tenders in udyogamandal Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

32285092
Portable Detectors Portable Detectors For Ammonia, Chlorine And So2 , Portable Detector For Ammonia Intrinsically Safe Portable Gas Detector Designed For Monitoring The Presence Of Ammonia Vapours. The Device Shall Be Ergonomically Designed For Easy Use
Limitted
Indian
Kerala
udyogamandal
01-06-2022

Tender Details

Portable Detectors Portable Detectors For Ammonia, Chlorine And So2 , Portable Detector For Ammonia Intrinsically Safe Portable Gas Detector Designed For Monitoring The Presence Of Ammonia Vapours. The Device Shall Be Ergonomically Designed For Easy Use And Fits In The Hand For Easy Sampling And Have A Data Logging Facility. Sensor : Ammonia Measuring Range : Min. 0 – 300 Ppm Resolution : Min. Range Increments 1 Ppm Make : Honeywell / Draegger / Msa / Riken-Keiki / Crowcon / Ion Display : Lcd Weight: Not More Than 800 Grams Operating Temperature: -20O C To 50O C Ingress Protection : Ip 65 Or Above Alarms: Visual, Vibration, And Audible ( Not Less Than 95 Db ) ( For Twa, Stel ) Pump: Integrated Pump Casing / Boot : High Impact, Durable, Rubberized Language : English Approvals : Ce And Atex / Iecex : The Instrument Should Have Approval From A Competent Authority To Use In Class I, Division 1, Group A, B, C, D. Warranty : Minimum 2 Years For The Device Including The Sensor. Minimum One-Year Warranty For Battery / Power Supply. Calibration: First Calibration After Supply Shall Be Done By The Supplier Without Additional Cost. • Carrying Case Shall Be Provided • Approvals, Calibration Certificates, And Instruction Manual For Operation To Be Submitted Along With The Supply. , Portable Detector For Chlorine Intrinsically Safe Portable Gas Detector Designed For Monitoring The Presence Of Chlorine Vapours. The Device Shall Be Ergonomically Designed For Easy Use And Fits In The Hand For Easy Sampling And Have A Data Logging Facility. Sensor : Chlorine Measuring Range : Min. 0.0 – 10.0 Ppm Resolution : Min. Range Increments 0.1 Ppm Make: Honeywell / Draegger / Msa / Riken-Keiki / Crowcon / Ion Display : Lcd Weight: Not More Than 800 Grams Operating Temperature : -20O C To 50O C Ingress Protection : Ip 65 Or Above Alarms: Visual, Vibration, And Audible ( Not Less Than 95 Db ) ( For Twa, Stel ) Pump: Integrated Pump Casing / Boot : High Impact, Durable, Rubberized Language : English Approvals : Ce And Atex / Iecex : The Instrument Should Have Approval From A Competent Authority To Use In Class I, Division 1, Group A, B, C, D. Warranty : Minimum 2 Years For The Device Including The Sensor. Minimum One-Year Warranty For Battery / Power Supply. Calibration: First Calibration After Supply Shall Be Done By The Supplier Without Additional Cost.. • Carrying Case Shall Be Provided • Approvals, Calibration Certificates, And Instruction Manual For Operation To Be Submitted Along With The Supply. , Portable Detector For So2 Intrinsically Safe Portable Gas Detector Designed For Monitoring The Presence Of So2 Vapours. The Device Shall Be Ergonomically Designed For Easy Use And Fits In The Hand For Easy Sampling And Have A Data Logging Facility. Sensor : Sulphur Dioxide Measuring Range : Min. 0.0 – 100.0 Ppm Resolution: Min. Range Increments 0.1 Ppm Make: Honeywell / Draegger / Msa / Riken-Keiki / Crowcon / Ion Display : Lcd Weight: Not More Than 800 Grams Operating Temperature : -20O C To 50O C Ingress Protection : Ip 65 Or Above Alarms: Visual, Vibration, And Audible ( Not Less Than 95 Db ) ( For Twa, Stel ) Pump: Integrated Pump Casing / Boot : High Impact, Durable, Rubberized Language : English Approvals : Ce And Atex / Iecex : The Instrument Should Have Approval From A Competent Authority To Use In Class I, Division 1, Group A, B, C, D. Warranty : Minimum 2 Years For The Device Including The Sensor. Minimum One-Year Warranty For Battery / Power Supply. Calibration: First Calibration After Supply Shall Be Done By The Supplier Without Additional Cost. • Carrying Case Shall Be Provided • Approvals, Calibration Certificates, And Instruction Manual For Operation To Be Submitted Along With The Supply. => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

ITEM: PORTABLE DETECTORS
Sl. No. Item Description
1Portable Detector for Ammonia Intrinsically safe portable gas detector designed for monitoring the presence of Ammonia vapours. The device shall be ergonomically designed for easy use and fits in the hand for easy sampling and have a data logging facility. Sensor : Ammonia Measuring Range : Min. 0 – 300 ppm Resolution : Min. range Increments 1 ppm Make : Honeywell/ Draegger/ MSA/ Riken-Keiki/ Crowcon/ ION Display : LCD Weight: Not more than 800 grams Operating Temperature: -20o C to 50o C Ingress protection : IP 65 or above Alarms: Visual, Vibration, and Audible (not less than 95 dB) (For TWA, STEL) Pump: Integrated Pump Casing/Boot : High impact, durable, rubberized Language : English Approvals : CE and ATEX/ IECEx : The instrument should have approval from a competent authority to use in Class I, Division 1, group A, B, C, D. Warranty : Minimum 2 Years for the device including the sensor. Minimum one-year warranty for battery/ power supply. Calibration: First calibration after supply shall be done by the supplier without additional cost. • Carrying case shall be provided • Approvals, Calibration Certificates, and Instruction Manual for Operation to be submitted along with the supply.
2Portable Detector for Chlorine Intrinsically safe portable gas detector designed for monitoring the presence of Chlorine vapours. The device shall be ergonomically designed for easy use and fits in the hand for easy sampling and have a data logging facility. Sensor : Chlorine Measuring Range : Min. 0.0 – 10.0 ppm Resolution : Min. range Increments 0.1 ppm Make: Honeywell/ Draegger/ MSA/ Riken-Keiki/ Crowcon/ ION Display : LCD Weight: Not more than 800 grams Operating Temperature : -20o C to 50o C Ingress protection : IP 65 or above Alarms: Visual, Vibration, and Audible (not less than 95 dB) (For TWA, STEL) Pump: Integrated Pump Casing/Boot : High impact, durable, rubberized Language : English Approvals : CE and ATEX/ IECEx : The instrument should have approval from a competent authority to use in Class I, Division 1, group A, B, C, D. Warranty : Minimum 2 Years for the device including the sensor. Minimum one-year warranty for battery/ power supply. Calibration: First calibration after supply shall be done by the supplier without additional cost.. • Carrying case shall be provided • Approvals, Calibration Certificates, and Instruction Manual for Operation to be submitted along with the supply.
3Portable Detector for SO2 Intrinsically safe portable gas detector designed for monitoring the presence of SO2 vapours. The device shall be ergonomically designed for easy use and fits in the hand for easy sampling and have a data logging facility. Sensor : Sulphur dioxide Measuring Range : Min. 0.0 – 100.0 ppm Resolution: Min. range Increments 0.1 ppm Make: Honeywell/ Draegger/ MSA/ Riken-Keiki/ Crowcon/ ION Display : LCD Weight: Not more than 800 grams Operating Temperature : -20o C to 50o C Ingress protection : IP 65 or above Alarms: Visual, Vibration, and Audible (not less than 95 dB) (For TWA, STEL) Pump: Integrated Pump Casing/Boot : High impact, durable, rubberized Language : English Approvals : CE and ATEX/ IECEx : The instrument should have approval from a competent authority to use in Class I, Division 1, group A, B, C, D. Warranty : Minimum 2 Years for the device including the sensor. Minimum one-year warranty for battery/ power supply. Calibration: First calibration after supply shall be done by the supplier without additional cost. • Carrying case shall be provided • Approvals, Calibration Certificates, and Instruction Manual for Operation to be submitted along with the supply.