Military Engineer Services-MES has published Repairs To Communication Cable Ducts Cover Slabs Drain And Other Allied Works At Itr Chandipur Under Age Br Ii Chandipur. Submission Date for this Tender is 06-06-2022. Cable Tray Tenders in chandipur Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | NOTE (Applicable for all items) :- The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. |
2 | Demoilition Concrete in ground floors and pavings n exc 15 cm thick (below or above ground level) complete all as specified & directed. |
3 | Demolition of brick work or stone / boulder masonry, built in lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles.built in cement mortar complete all as specified & directed. |
4 | Demoition RCC in ground floors and pavings n exc 15 cm thick (below or above ground level) complete all as specified & directed. |
5 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
6 | M & L 10 mm thick cement plaster in CM 1:4 mixed with WPC as per manufacturers instructions finished even and smooth without using extra cement on walls (WPC shall be paid separetly) complete all as specified & directed. |
7 | M & L 10 mm thick cement plastering in CM 1:6 finished even and fair on walls complete all as specified & directed. |
8 | M & L PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filing and mass concrete complete all as specified & directed. |
9 | Supply only integral water proofing compound complete all as specified & directed. |
10 | M & L Brick work in cement mortar 1:6 , with old size fly ash brick bricks, straight or curved in plan exceeding 6 m mean radius complete all as specified & directed. |
11 | M & L for preparation of newly plastered surface on wall and applying two coats of white wash complete all as specified & directed. |
12 | M & L for preparation of old plastered surface on ceiling and applying two coats of white wash complete all as specified & directed. |
13 | M & L for RCC 1:2:4 Type B 1 (using 20mm graded aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. |
14 | M & L for RCC 1:2:4 Type B 1 (using 20mm graded aggregate) as in column/ posts complete all as specified and as directed. |
15 | M & L Cement concrete 1:2:4 type B1 using 12.5 mm graded stone aggregate as in copings and in shelves and the like etc all as specified and directed. |
16 | M & L MS TMT bars (Fe 500 D) 10 mm and above, cut to length ,bent to shape required , including cranking , bending , spirally for hooping forcolumns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as in reinforcement complete all as specified & directed. |
17 | All as per Sl Item No. 15 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrus, spaces, and binders complete all as specified & directed. |
18 | Providing precast cement concrete 1:2:4 type B1 20mm graded stone aggregate as in landings, cover slab, shelves and similar work like RCC block for pintel hingesincl necessary formwork complete all as specified & directed. |
19 | S & F 150 mm dia rain water UPVC (SCH-80) pipe including laying necessary joints all as specified and directed. |
20 | S & F Low density polyet-hylene pipes (LDPE), 50mm dia of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc as in weep holes. |
21 | M & L for cement concrete in 1:3:6 type C-2 (using 40 mm graded aggregate) as in Surface channel complete all as specified & directed. |
22 | Extra for forming fair finished drain or channel 30cm innder grith in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified & directed. |
23 | Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto |
24 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out in soft/loose soil. |
25 | Returning filling in loose and soft soil including spreading leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified & directed. |
26 | Removing excavated material n.exc. 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified & directed. |
27 | M&L Formwork to sides of concrete, flat rough finished surface foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |