}

Supply, Installation, Testing And Commissioning Of Outdoor Signalling And Telecommunication System At Dharmavaram And Passenger Amenities System ( Ipis, Pa, Cctv Etc ) At Anantapur And Dharmavaram Stations In Connection With Doubling Works O, gurugram-Haryana

Rail India Technical And Econimics Services Ltd-RITES has published Supply, Installation, Testing And Commissioning Of Outdoor Signalling And Telecommunication System At Dharmavaram And Passenger Amenities System ( Ipis, Pa, Cctv Etc ) At Anantapur And Dharmavaram Stations In Connection With Doubling Works O. Submission Date for this Tender is 06-06-2022. CCTV System Tenders in gurugram Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

32219980
Supply, Installation, Testing And Commissioning Of Outdoor Signalling And Telecommunication System At Dharmavaram And Passenger Amenities System ( Ipis, Pa, Cctv Etc ) At Anantapur And Dharmavaram Stations In Connection With Doubling Works O
Open Tender
Indian
Haryana
gurugram
06-06-2022

Tender Details

Supply, Installation, Testing And Commissioning Of Outdoor Signalling And Telecommunication System At Dharmavaram And Passenger Amenities System ( Ipis, Pa, Cctv Etc ) At Anantapur And Dharmavaram Stations In Connection With Doubling Works On Gooty-Dha Supply, Installation, Testing And Commissioning Of Outdoor Signalling And Telecommunication System At Dharmavaram And Passenger Amenities System ( Ipis, Pa, Cctv Etc ) At Anantapur And Dharmavaram Stations In Connection With Doubling Works On Gooty-Dha

Key Value

Document Fees
INR 18000 /-
EMD
INR 1377173.0 /-
Tender Value
INR 13.77 Crore /-

BOQ Items

Name of Work:Supply, Installation, Testing & Commissioning of Outdoor Signalling & Telecommunication system at Dharmavaram and Passenger Amenities System (IPIS, PA, CCTV etc) at Anantapur & Dharmavaram stations in connection with doubling works on Gooty-Dharmavaram Section of South Central Railway of Guntakal Division
Sl. No. Item Description
1SMPS based Integrated Power Supply as per RDSO Specification No.RDSO/SPN/165/2012 (Ver 3.0) with latest ammendment & as per technical specificationalongwith VRLA Battery Bank of 200AH Confirming to RDSO Spec. No. IRS:S93/96(A) Amndt.-1 or latest & Battery rack (IPS Configuration shall be as per technical specification) Note: contractor shall get approval for size and module from Engineer In charge.FOR 6 LINE STATION
2Supply of QNAIK Relays 6F/6B (24 V, 1000 Ohms) for WJR contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A,933A,932A,935A 937A 960 & RDSO/SPN/84 ver 2.0
3Screw less rail mounted 2.5 sq mm 4 conductor, 2 in" 2 out disconnect terminal block front entry cage clamp of wago make or similar. This item includes Supply of marker strips.
4Supply of End plate for above item no. 40 wago make or similar. (orange)
5Supply of end stopper for above item no. 40 wago make or similar (Grey)
6Supply of carrier rails of dimension 35mmX7.5mm, 1mm thickness unsloted type for above item a) wago make or similar. Note: Carrier rail shall be 1mm thick without slot for above blocks. (Length of each piece shall be 42.8 cms/ as per site incharge)
7PVC insulated armoured, unscreened,underground railway signaling copper conductor cableconfirming toRDSO specification No. IRS:S-63/2014 & IS:1554(part-1) (Rev 4) with Amendment -2 or latest of sizes:
812 core x 1.5 sq.mm.
924 core x 1.5 sq.mm
10PVC insulated Railway signalling indoor single core cableas per colour coding scheme of Raliways confirming to RDSO Specification No: IRS-S-76/89 amendment-3.
1116 x 0.2 mm.(Grey)
121x10 sq mm.(multistrand flexible wire)
13Supply and placing of second class bricks size 225mm x 112mm x 75mm (9 bricks per Mtr.) after laying of cable & refilling the trench by loose soil of 100mm to cover cable.
14Transportaing ,Supply and installation of Concrete (RCC) route indicators at intervals of 50 meters as per technical specification. They should be of standard RCC with letters "SCR S&T cable" as per type of cable laid to drawing OF SCR . In case of telecom quad cable joint locations it shall be painted with red color. All material required for casting & curing foundations, fixing equipment, smithy works, making rod/wire run nut bolts.etc. shall be supplied by the contractor.
15Galvanised Iron pipe 100 mm dia `B" class,(6 Mtr. Length) as per specn.No.IS-1239, part 1 / 1990. along with threaded coupler (Perforated with 6 mm holes)
16Colour light signal (4aspect)complete set as per drg.No.SA23002 A/M (adv.) alt.9 & Specn. IRS-S-26/64 consisting of the following items :
17Signal post 140 mm dia 4.5/5.5mtrs. long to IRS-S-6-81.
18Signal base Cast Iron 140 mm dia. to drg. No.S-2011/M.
19CLS ladder complete with platform and base 4.5 mtrs.long to drg.No.SA-23153 (Adv.) Alt 1.
20Colour Light Signal Unit 4 Aspect complete with outsignal transformers,lenses & lamps, suitable for 140 mm dia.post as per drg.No.SA - 23003 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.
2104 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 with latest amendment.
22Junction type route indicator 2 way complete without lenses, lamp holders and lamps. to IRS-S-66/84 Amd -1with RDSO drg.No.SA-23401 (Adv.) alt 2 or latest.
23Junction type route indicator 3 way complete without lenses, lamp holders and lamps. toIRS-S-66/84 Amd -1with RDSO drg.No.SA-23401 (Adv.) alt 2 or latest.
24OFF set bracket for Colour light signal 140mm outside dia.post with "U" bolt and nuts as per drg No: SA-23080 (adv.) alt. 1.
25Supply of universal locks with one key for every ten locks.
26Independent shunt signal complete having following items.
27Shunt signal post 90 mm dia 1m long to IRS-S-6/81.
28Shunt signal surface base 90 mm dia drg.No. S-2011.
29Position light shunt signal unit without lamp holder unit,lenses & lamps to RDSO drg.No.SA-23840(adv.) .
3004 nos. anchor bolts for shunt signal (305mm. X 50mm. X 20mm.) to drg.No.SA-110 A/M.
31Shunt signal dependent type drg No. SA-23840 (adv.) ) with offset bracket 3½"" dia.to suit 140mm. Outside dia post complete without lenses, lamps & lamp holders.
32LED based Signal lighting unit for Route Indicator with built-in current regulator as per RDSO Specn. No.RDSO/SPN/153/2011 Rev. 4.1 or latest suitable for 110/100 V AC and to use with conventional/ LED ECR.
33Fibre glass Track Lead Junction Boxes as per Drg. No. CWM-00597 of FRP material to IRS .5.23specification along with fixtures i.e on MS angle 50x50x5 mm 0.9 meter long ,two numbers of GI pipes of 25 mm dia of 500 mm long with nuts and bolts and (this inclueds gromite buses and dummies ,60mm PBT terminals).
34channel bond pin single groovesper RDSO Spec :S-17/75
35SupplyofGKP type Location BoxesFullsizeasperdrg.No. S&T/MFT/2378 (Single).
36SupplyofGKP type Location Boxeshalf a perdrg. No. S&T/MFT/2378 (Half).
37Electric lifting barrier setcomplete with all accessories as per RDSO Specn. No. RDSO/SPN/208/2012 (Ver 2.0)band as per Technicalpecification s,with latest Amdt. along with one set of spare boom (booms of both the sides of road). The operating voltage shall be 24V DC.
38Design, prepearation & supply ofSix (06) hard copies of each documents along with soft copy for the mention below alongwith original tracing on a standard 7.5microne polyester film in AUTO CAD FORMAT. (The item includes supply of two sets of drawings for approval and corrections thereon as suggested by RITES)
39Cable route plan.
40Location box details with location wiring diagram.
41Cable termination details
42Cable corage plan
43C.T. Rack details
44Track bonding plan
451. Supply and installation of basic material to construct unit maintenance free earth consisting as per RDSO spec no.RDSO/SPN/197/2008
46copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked--1 no.
47Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-03 No.
48Copper strip of 150X25x6mm to terminate earth rod-1 No.
49Copper strip of 300X25x6mm (MEEB)-1 No.
50Copper strip of 150X25x6mm (SEEB)-1 nos
51Earth electrode and coupler along with earth enhancing compound material(10kg pack)
5210sq. mm, 16sq.mm, 35 sq.mm cable as per the requirement (drawing)
53Supply of Electric point operating machine IRS type ( AC immunity 160 V AC) non trailable, to operate on 110 V DC complete with lock, detector, cable termination box and slides for lock and detector- rotary locking, universal type as per specification IRS-220 mm throw & Clamp point Lock 60Kg TWSas per Drg. No. RDSO/S-11000 &RDSO/S-3395 including P-Clamp type Ground connection SUITABLE FOR IRS-220 mm throw thick web point machine with all accessories (RDSO drg no. S3454/Alt-A).It shall also include all necessary nylon insulators for insulating connecting rods from Rails and point machines.
54Supply of Non-deteriorating type of fuse holders & fuse links - electric fuse for Railway signalling Rate (in Rupees)d voltage 240 AC/DC to Specn. No. IRS S.78/92 (IRS-S-78/97 Tentative) IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip / knife edge type size E1 (R-SS) amp. as per below break up
55Fuse Holder 20A Capacity
56Fuse Link
57Supply of Power Wire PVC Insulated Single Core multi strand unsheathed with plain annealed copper conductor as per IRS:S-76/89 Amndt - 3, copper cable of 28/03mm- for wiring in track circuit battery location box in Red & Black colour.
58Supply & installation of Magnetic sensor (proximity switch)for Door in relay rooms etc
59Supply and Instrallation of Signal Mesh as South Central Railway Practice
60Supply of Multi Lamp Route Indicator (LED double digit) for 1 to 19 (double digit) with white LED along with housing as per specifi cation IRS: S 66/84 Amd. 1 or latest and drawing No. SA 23761 (Adv.) or latest. Lamp proving compatible with Normal bulb type multi lamp route indicators. Retrofi ts the existing conventional multi lamp type route indicators housing. Input operating voltage 110V AC +25%. Uniform intensity over entire operating range.
61Supply and Installation of Tranformer rectifier 110V AC Input/24V-30V DC Output, 1 Amp capacity, as per spec. IRS S 91-93 with amendment 1 or latest.
62Supply and Installation of Tranformer rectifier 110V AC Input/24V-30V DC Output, 5 Amp capacity, as per spec. IRS S 91-93 with amendment 1 or latest.
63Supply & Installation ofIndustrial grade with ingress protection standard of IP65/NEMA4, 4K VDU minimum 72 inches (LED/ Plasma) monitor of Mitsubishi/BARCO/Delta/NEC/Sony/Toshiba/Panasonic/Samsung/LG make for operation and indication of various functions.
64Supply of Low maintenance lead acid stationary secondary cells of 2V/ 80 AH along with connecting links, floats & insulators as per RDSO specification No.IRS-S- 88/2004.
65Supply of Single Section Digital Axle Counter (Phase Reversal Type) as per RDSO Specn. No .RDSO/SPN/177/2012 (Ver.3) or latest consisting of the following: i) High frequency TX Coil and RX Coil (AD-711) consisting of web mounting type Tx = 02 Nos. & Rx = 02 Nos.) – 01 Set ii) Track side digital axle counter unit DACF-710P -2 Nos. iii) Vital Relay box duly wired = 2 Nos, each with 2 Nos. of 24V, 1000 Ohms, “Q” type relays. iv) Clamp with deflector plates and hardware etc. – 4 Nos. v) Reset Box –2 Nos. vi) Surge Voltage Protection Device – 2 Nos
66Supply of Daido type single line tokenless block instruments
67Block filter unit for block instrument for use in 25KV RE area as per RDSO spec. IRS:S-68/89 or latest
68Relay DC Polarised 3 position 77 ohms 1 N/R contacts,metal to metal, centre based armature conforming to IRS:S 31-80, IRS:S 34 & IRS:S 23 (as applicable)
69Non-Split double wall corrugated (DWC) pipe of HDPE Confirming to IS:14930 part-II, with threaded coupler, of following sizes:
70Size 120mm outer dia and 103 mm inner dia
71Size 200mm outer dia and 175 mm inner dia
72Supply of Half split double wall corrugated (DWC) pipe of HDPE in 2/3 meter length produced out of full round DWC pipes as per IS:14930 part-II marked on it. This item includes supply of necessary fixing & coupling arrengement.
73Size : 120 mm outer dia. and 103 mm inner dia.
74Size : 200 mm outer dia. and 175 mm inner dia.
75Calling on signal unitposition light type complete with mounting socket to Drg No. SA-24351 (Adv) or latest, specn. No. IRS-S:10/78, IRS-S:26/64.
76LED signal lighting unit for shunt signal conforming to Indian Railway chromatically standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.-4 with latest amendment (This includes fuses and other accessories required for fixing)
77LED Based Signal for calling on signal conforming to Indian Railway chromaticallity standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.-4.1 with latest amendment. (This item includes fuses and other accessories required for fixing)
78Excavation of trench to a depth of 1200mm and width of 300m at bottom in all types of soil(Normal soil/soft soil/sandy soil except inhard morum / rocky soils /bridges/ level crossings/ track crossings/ coil pits, )as per RDSO Sketch noSDO/CABLELAYING/003including marking of cable alignment, clearing ofjungle, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work as directed by supervisor in-charge. NOTE: Supply of Cable markers, Supply and Laying of RCC Trunking & cappings are covered separately.
79Excavation of trench to a depth of 1200mm and width of 300m at bottom inhardmorum soil as per RDSO Sketch noSDO/CABLELAYING/003including marking of cable alignment, clearing ofjungle, bushes, trial pits ifrequired, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work as directed by supervisor in-charge
80Cutting of rock to a depthof 200 mm and width of 200 mm where rock is visible from surface to a depth more than300 mm up to 550mm, excavation of trench withwidth300mm aboverockconcreting 200mmx200mm x 100mmafter laying of cable with 1 cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, refilling with excavated soil ramming and consolidation exceptinbridges,culverts,levelcrossings,track crossings, cable pits, rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in-charge. DrgNo.SK/CN/NEW/3. All the material is to be arranged by contractor.
81Cutting of rock to a depthof 200 mm and width of 200 mm where rock is visible from surface to a depthup to 300 mm, excavation of trench withwidth300mm aboverockconcreting 200mmx200mmx200mm after laying of cable with 1 cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, refilling with excavated soil ramming and consolidation exceptinbridges,culverts,levelcrossings,track crossings, cable pits, rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in-charge. Drg No.SK/CN/NEW/2. All the material is to be arranged by contractor..
82Breaking of metal/ tar road and refilling after laying the cables as per drawing no.SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface.
83Track crossing by horizontal boring method based on SC Railway practiceand as advised by the engineer at site. This includes the supply and insertion(pushing) of GI pipe (80/100/200mm) confirming to IS.1239 heavy class in the bore drilled with the coupler between two pipes. All the joints of casing pipes should be tight and leak proof.
84Trenching under Rails for crossing the track(Track crossing) and refilling of trenches as per RDSO drawing No.SDO/CABLE LAYING /009. The track crossing shall be done at right angles.The depth of cable trench shall be 1.2 Mtr. below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 Mtr.. The ballast shall be Stored separately while making the trench and the earth soil shall be stored separately. while re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. this work has to be done under supervision of supervisor of S&T and supervisor of P.Way
85Laying of S&T cables of various cores/pairs/quads in trenches/GI pipes/ DWC pipes/trunking.This also includes laying of cables in track crossings & road crossings. This also includes transportation of cable drums from contractors store to site for laying and provision of labels on each cable of coloured plastic adhesive tapes or any other identifiable material to give the cable number at each G.P.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposess. This work is to be done as per tech. specification para.-17.0.
86Termination of outdoor cables, main cables laid in location boxes and Cable termination rack etc. at both ends. Both ends of a cable core terminated shall be counted as onetermination.The item includes dressing of cable after termination.
87Fixing & laying of GI pipe (Supply of GI Pipe is covered separetely )at crossing or culverts along bridges etc. and concreting the ends with brick channelling at both ends as per Drg. No. SK/SC/CN/ west12/87.This includes fixing of clamps of suitable size & shape where more than one pipe length is required to be kept at stretch. The clamps will mild steel strip of 5mm thick & 25 mm wide approx. A minimum of 3 clamps per GI pipe of standard lenght of 6 mtrs. to be provided.
88Excavation of pit, casting & plastering of concrete foundation for C.L.Signal & ladder. as per Drg.No.SK-15/10. This includes :Supply of cement, sand, stone chip 20 mm & mixingin the ratio 1:3:6.
89Excavation of pit and casting concrete foundationof apparatus case full size as per Drg. No. SK- 18/10 and fixing of 2 No.of "E" type lock.
90Supply of 4 nos. anchor bolts as per RDSO drawing no. SA-112A with nuts and washers.
91Supply of cement, sand, stone chip & mixing in the ratio 1:3:6.
92Excavation of pit and casting concrete foundation of apparatus case half size as per Drg. No.SK-17/10 and fixing of 2 No.of "E" type lock.
93Supply of 4 nos. anchor bolts as per RDSO drawing no. SA-112A with nuts and washers.
94Supply of cement, sand, stone chip & mixing in the ratio 1:3:6.
95Cement concrete work for miscellaneous items in the ratio 1:3:6 Item includes excavation raming, curing and plastering with cement & sand mixture (Aggregate not exceeding 3.8 cm). Aggregate cementsand and holding down bolts nuts to be supplied by the contractor.
96Note : Due to local condition in very special circumstances if the size of the foundation for all the above items, required to be increased/decreased, the extra payment deduction for variation of the CC work shall be calculated on volumetric basis as per rate of item no. 24.
97Providing brick massonary in ratio 1:6 cement annd mortar including plastering with 1:4 cement and sand mixture both sides. 20mm thick each with contractor"sown IInd nd class bricks including excavation curing, grouting,bolting etc.Whereever required bricks sand and cement to be supplied by the contractor.
98Strengthening of foundations of signals, Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
99Erection of full location box on foundation including fixing of `E"type lock & locking arrangement,wiring, testing & commissioning as per approved disposition plan& wiring diagram.This also includes:
100Supply & fixing of hylum sheet, resin bonded 6 mm thick grade P3 for fixing terminal, fuse blocks etc.
101Bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.
102Filling up pit inside the location box by sand and plastering on the topof the sand.
103Fixing of angle iron frame for "Q" type relays in location box. This includes supply of angle iron for fixing relays wherever required.
104Fixing of terminals, fuse blocks, N.D. fuses, etc. as per SCR railway practice.
105Erection of half location box on foundation including fixing of `E"type lock & locking arrangement. relay wiring, testing & commissioning as per approved disposition plan & wiring diagram.This also includes :
106Supply & fixing of hylum sheet, resin bonded 6 mm thick grade P3 for fixing terminal, fuse blocks etc.
107Bunching of cables with PVC tape including supply of ferrules, tape,cable fixing clamps etc.
108Filling up pit inside the location box by sand and plastering on the topof the sand.
109Fixing of angle iron frame for "Q" type relays in location box. This includes supply of angle iron for fixing relays wherever required.
110Fixing of terminals, fuse blocks, N.D. fuses, etc. as per SCR railway practice.
111Erection of2 aspect colour light signals.This includes :
112Erection of surface base, signal post, signal unit, signal number plate, ladder with guard & platform. This item also includes erection of junction type route indicator/multi lamp type route indicator, shunt signal on offset bracket,calling on signal, P/C/G marker & blanking-off signals where required.
113Fixing ofhoods & LED lamp units with current regulator on 2 aspect signal unit & and subsidiary signals (where provided). Termination of the tail cable in the signal unit.
114Wiring & testing of main signal and subsidiary signals (where provided).
115Erection of3 aspect colour light signals.This includes :
116Erection of surface base, signal post, signal unit, signal number plate, ladder with guard & platform. This item also includes erection of junction type route indicator/multi lamp type route indicator, shunt signal on offset bracket,calling on signal, P/C/G marker & blanking-off signals where required.
117Fixing ofhoods & LED lamp units with current regulator on 3 aspect signal unit & and subsidiary signals (where provided). Termination of the tail cable in the signal unit.
118Wiring & testing of main signal and subsidiary signals (where provided).
119Erection of4aspect colour light signals.This includes :
120Erection of surface base, signal post, signal unit, signal number plate, ladder with guard & platform. This item also includes erection of junction type route indicator, shunt signal on offset bracket,calling on signal, P/C/G marker & blanking-off signals where required.
121Fixing ofhoods & LED lamp units with current regulator on 2 aspect signal unit & and subsidiary signals (where provided). Termination of the tail cable in the signal unit.
122Wiring & testing of main signal and subsidiary signals (where provided).
123Excavation of pit, casting & plastering of concrete foundation for shunt signal.As per Drg. No.SK-16/10and Technical Specification. .This includes :
124Supply of cement, sand, stone chip & mixingin the ratio 1:3:6.
1254 nos of anchor bolts.
126Erection & wiringof independent shunt signal.This includes :
127Erection of surface base, shunt signal post, shunt signal unit and number plate.
128Fixing ofhoods and LED lamps.
129Termination of the tail cable in the signal unit, wiring & testing of shunt signal.
130Fixing & wiringof track circuitequipment such as battery chargers, track feed resistance, `B" type choke, track relays inlocation box as per SC Railway practice and Technical specifications para 34 and approved wiring diagram . Thisincludes :- (i) Supply, fabrication & fixing of duly varnish teakwood planks 25 mm thick for placing track charger, choke, batteries. (ii) Supply of fixing material.(iii) installation of batteries in separate box as per drg. no. sc railway practice. iv) painting and numbering of Track circuit. v) Charging of track batteries
131Installation, wiring, testing & commissioning ofDC track circuits as perapproved standard practice and technial specification para-. This includes :
132Supply of all types of lead wires, jumpers and rail head continuity bonds as specified in Technical Specification.
133Installation of all types of lead wires, jumpers and rail head continuity bonds by pin brazing technique using contractors own consumables & pin brazing machine as specified in Technical Specification.
134Fixing of track lead junction boxes as per SCRailways Practices
135Charging of track Batteries, Energising the track circuit and testing with 0.5 ohms train shunt resistance.
136On straight portion of track
137On point and crossingportion of track
138Fixing of EKT/RKT relays at ASM Room/in field inlocation boxes.
139Item includes supply, fixing and wiring of push buttons and LEDs for EKT/RKT circuit. The EKT/RKT relays, push buttons, LEDs to be fixed on the wooden box in side the ASM room.
140Supply and fixing of crank handleboxes
141Fixing of Electrical Point Machine on the extended sleepers at points as per std. practice- and RDSO Drawings. This item also includes: 1.fixing of switch extension bracket("P" bracket) and ground-connections.2. fixing nylon insulation for switch extension bracket, gauge tie plate, driving lug and P-way stretcher bars. 3. Adjusting opening of the switches to 115mm.4. Testing of point machine as specified in technical specifications.
1425. Wiring inside the point machine, termination of tail cable in point machine and junction boxes.6. Erection of junction box on M.S. angle of 50 x 50 x 5mm& 1 m length and fixing of M6 terminals on 10mm hylem sheet for cable termination. 7. supply and fixing of bend GI pipes for taking cable into point machine and junction box (Gland pipe) for points. 8. all black smithy & fitting works required at site for complete installation.
143NOTE:1. Material for installation like10mm hylam sheet, GIpipes, MS pins, split pins, wiring materials, various fixing nuts & bolts including castle nuts, spring washers will be supplied by the contractor. 2. The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 kg as per yard lay out. 3. cable entry from junction box to point machine shall be made as per SC raiway practice.
144Fabrication and supply of GI termination box for point machine of size 45cm x 23cm x 12 cm, the termination box to be fabricated out of GI sheet 10SWG.
145Erection of cable termination rack complete alongwith wall support, ladder etc. as per Technical Specification. and SC RailwayDrg/practiceThis includes :
146(i) Supply of nuts & bolts, MS clamps &cement for massonary works. (ii) Supply & fixing of hylum sheet.
147Erection of Relay rack 1way with scaffolding suitably concreting tri-pod bases using J-bolts, fixing rack supporting of size 50x50x6 mm on to the wall. Reel insulators are to be provided for insulating the rack from the scaffolding & tri-pod bases. ( payment based on number of equivalent 1 way relay racks).
148Painting of two coats ofenamelpaint over one coat ofRed oxide primer on the following items after scrapping and cleaning of the surface whereever necessary. Primer & paints both Asian make are to be supplied by contractor. Location boxes to be painted inside & ouside also. work has to be done as Technical Specification..
149Full Location box
150Half Location box
151Painting of two coats ofenamelpaint black Asian and Aiuminiumwhite asapproved by Site engineer over one coat ofprimer on Main signal post with signal unit,surface base complete with route indicator, subsidiary signals, ladderfittings as per Indian Rlys. standard practice. work has to be done as per SC Railway practice.
152Painting of two coats ofenamelpaint black Asian and Aiuminiumwhite asapproved by Site engineer over one coat ofprimeron Shunt signal unit , base and post. work has to be done as SC Railway Practice.
153Painting of two coats ofenamelpaint black Asian and red oxide asapproved by Site engineer over one coat ofprimeron point machine and ground connection respectively. work has to be done as per SC Railway practice.
154Supply & Erection of sighting boardas warning board/Stop Board/BSL/ Calling on instructionboard etc as per SC railway practice
155Testing and commissioning of all outdoor gears. All artisan staff and labours required for testing and commissioning of work shall be provided by contractorfor. All testing kits & tools shall be provided by contractor at his own cost. testing shall be carried out by contractor in presence of RITES/Rly up to his satisfaction and neccesary alterations shall be done. Contractor shall depute sufficient staff to carryout outdoor work during commissioning for completion of work within stipulated time.This include cable meggering, earth value recording, sighting committee report, testing from CTR, testing in cordination with indoor agency, work during Pre NI/ NI etc.
156Installation, Testing & commissioning of Power operated Lifting Barrier complete as per insruction of Engineer at site. It includes RCC foundation for pedestal, fixing of boom supports, warning bells, hooters etc, both liftig barrier along with boom locking arrangements. The item includes wiring of road signals, LED lamps and installation & wiring of the road signals as per site requriements. Any other material required for installation and commissioning of lifting barrier will be supplied by the contractor. note: this includes Painting of particulars at gate lodge
157Dismantling of S&Tgears andcables(Indoor& Outdoor) deposite in store. Including dismatttlaing of Foundations etc.
158FixingNon Split Dwc pipe for laying of cables ( including under neath the track, Road Crossing or other platform cutting etc. ) as per drg no.Rites/Sig/Gen/028-98, Rites/Sig/Gen/031-98 ( as applicable )
159Fixing Half Split Dwc pipe for laying of cables ( including under neath the track, Road Crossing or other platform cutting etc. ) as per drg no.Rites/Sig/Gen/028-98, Rites/Sig/Gen/031-98 ( as applicable )
160Supply and Installation of Earth electrode assembly and concrete encloser with cover as per drg. No. RITES/SIG/GEN/013-98 and RITES/SIG/GEN/014-98 respectively. This includes providing connection to location box, signalunit, block instruments, cables etc. through GI wire 8 SWG suitably sparted on MS flats size 30 x 3 mm as per drg.No. RITES/SIG/GEN/015-98,RITES/SIG/GEN/016-98 & RITES/SIG/GEN/017-98. This includes:
161(i) Digingof pit in earth 3 m deep.
162(ii) Casting of cement concrete enclosure as per drg.No.RITES/SIG/GEN/014-98.
163(iii) Soil treatment as per standard practice involving supply & pouring of salt & charcoal.
164(iv) Connecting the equipment through earth lead wire & soldering.
165(v) Supply of cement,wiring material & soldering material in hard Morrum & pipeMS FLAT of suitable pipe
166Installation and commissioning of Diado single line tokenless block instrument and block filter unit on block counter, fixing & wiring of relays, block phones and other equipments required for Block instrument. This item includes installation of Block instruments at both the stations of a block section.
167Installation and commissioning of SSBPAC (Single Line) block instrument, fixing & wiring of relays, block phones and other equipments required for Block instrument. This item includes installation of Block instruments at both the stations of a block section.
168Installation, wiring, testing & commissioning of Single section digital axle counter. This includes following at both ends of block section: (i) Fixing of track transducers on the rails. (ii) Laying of track transducers cable from rail to way side electronic unit. (iii) Installation of way side electronic unit.(iv) Termination of cables and wiring in way side electronic unit. (v) Installation & Wiring of reset box/verification box
169Provision of IPIS SYSTEM @ ATP & DMM
170Supply of trilingual LED Based 5 line Train information display board (singleface) suitable to 5 digit train numbers with all accessories as Per RDSO specification no. RDSO/SPN/TC/61/2O15 Rev.4.0 amdt LED colour RED
171Supply of LED based single line double face Coach Indication Display Board with all necessary accessories as per RDSO specification no, RDSO/SPN/TC/61/2015 Rev.4.d amdt 1. LED Colour WHITE.Rain hood/sun guard for display boards to be provided in open area.
172Supply of trillugual LED Based single line Train information display board (double face) suitable to 5 digit train numbers with all accessories as Per (16x336) double sided as per RDSO/ SPN/TC/61/2015 (Rev.- 4.0 ) Amdt.-1 or latest .
173Supply of LED based At a Glance Coach guidence SingleFacedisplay board as per (32x192) Single sided as per RDSO/ SPN/TC/61/2015 (Rev.- 4.0 ) Amdt.-1 or latest . Color of LED: WHITE/AMBER
174Supply of 16 port Central Data Switch (CDS) conforming to RDSO specification no. RDSO/SPN/TC/108/2019, Rev-1.0,
175Supply of 16 port Platform Data Controller (PDC) conforming toRDSO/ SPN/TC/61/2015 (Rev.- 4.0 ) Amdt.-1 or latest
176Supply of Central Data Controller consisting of CPU with other accessories as per RDSO/SPN/TC/61/2015 (Rev.- 4.0 ) Amdt.-1 or latest. Announcement recordings in digital format as per details given by Railways. Software for announcement system, various types of display boards information management & LED/LCD PIS management One set with system and one set of soft copy in CD.
177Supply of controlconsole unit complete (Including driving software for train indication, coach indication & P A system conforming to RDSO spec. no. RDSO/SPN /TC/61/2015 Rev-,4.0 amdt 1 as per technical specifications.
178Supply of 16 Port unmanageable switch 10/100 Mbps Of MaKe CISCO OR ZYXEL OR D-LINK OR DAX or similar
179Supply of media converter single mode dual fiber with built in ac power supply , unit supports 100 Mbps with driving distance of 15 Kms with SC type connector and 10/100 Mbps Ethernet port of model FACT01/SA/SM15/ SC/AC of MROTEK MAKE or similar
180Supply of power cable 3 core 2.5 sq mm multi strand cable as per IS 694:1990 reaffirmed 1995 or latest suitable for IP based
181Supply of 5 pair PVC insulated twin twisted screened data communication cable made up of size 7/0.20 mm dia communication cable having insulation thickness of 0.25 mm polyester taped.0.6 mm drain wire overlapped with alluminium foil for screening. The rate includes Supply, laying and installation charges of PVC pipe in addition to supply and laying of Communication/cat 6 cable.
182Supply of D-Link/AMP/KRONE or similar make UTP CAT-6 Cable each drum/Box of 305 mtrs.
183Supply and drawing of PVC sheathed 2 core cable 47/0.193mm as per the site condition and instructions of incharqe superuisor
1846 core SM 9 /125 m double scratch, CSTA, uni tube, outdoor Optical Fibre cable as per ITU-T Recommendation G.652 Approved ISO 11801. Make-D-Link/Molex OR Equivalent
185Supply of 40" color TV Full Hd internet LED TVof model R562C or KDL-40W700C Bravia Sony make or equivalent with spec..
186Supply and installation of UPS 10 KVA with 6 hours back up along with all accessories including battery rack and connecting cables. Any other items required for installation at site should be arranged by the contractor. Battery: 12V/100AH minimum capacity. Number of SMF batteries as demanded by UPS Model / Make. Battery Make: EXIDE/AMARARAJA or similar Microprocessor controlled High input power factor > 0.95. Pure sine wave True double conversion technology. Self diagnostics Large LCD monitor 32 character with UPS operating status. High compatibility with generators. Smart over load & shor circuit protection for utility / invertor mode. Integelegent battery monitoring. Make: NUMERIC / APC or similar
187Supply of power supply extension board 8 way with surge protection of reputed brand
188Supply of 25mm dia PVC conduit pipe (Medium, 1.4mm thick minimum), ISI mark of reputed make.
189Supply & fixing of drivers stopping boards to match the CIBs as per the instruction of incharge at site.
190Supply and fixing of different sizes of PVC casing /Pipes as required by Railway atsite by fixing /clamping to the wall or laying in Floor for indoor wiring purposes. All Necessary hardware materials are to be arranged by contractor.
191Supply of all in one desktop computer withpre loaded operating system (Core i5 (6th Gen)/4 GB DDR 4/1 TB/Windows 10 Home/512 MB) (Black, 34.2 cmx 48.6 cm x 4.8 cm, 3.5 kg, 19.5 Inch Screen), Wired Keyboard, Wired Mouse, Power Adapter Make:- HP /Lenova/DELL or similar
192Supply of lightening and surge arrestors of class B&C suitable for single phase supply in TT network as per amendment 5 of RDSO spec.No.RDSO/ SPN/165/2004 or Latest and as recommended by RDSO letter No.STS/E/IPS/GENL dated 27.01.06(Amendment5). .
193Installation and commissioning of LED Based five line Train information display board (singleface) suitable to 5 digit train numbers with all accessories as Per RDSO specification no. RDSO/SPN/TC/61/2O15 Rev.4.0 amdt LEDcolour RED
194Installation and commissioning of single line double face Coach Indication Display Board (unCovered /Covered Area) with all necessary accessories as per RDSO specification no, RDSO/SPN/TC/61/2015 Rev.4 amdt 1. LED Colour WHITE. Or Latest and as per the instructions of incharge at site.
195Installation and commissioning of single line faced/single line double faced train indication boards as per RDSO/ SPN/ TCl 6112075, Amdt.1 Rev.4.0 or latest and as per the instructions of in charqe at site
196Installation and commission of At-A-Glance Display Board SingleFace as per RDSO spec no:- RDSO/SPN/TC/108/2019, Rev-1.0Amdt-1 or latest.(32x192) Single sided. All materials required for fixing and installation should be supplied by contractor.
197Installation and commissioning of Platform Data Controller ( PD C ) v i d e supply portion
198Installation and commissioning of Central Data Controller with central data swithc under supply portion.
199Installation of LED/LCD TV with all accessories including PVC pipes, drawing of co-axial/OFC cable through PVC & fixing of MS angular frame.
200Cutting of platform min. 10 inchwide and 10 inch depth and restoration of the surface to its normal condition.
201Cutting of trench across /metal road / platform for laying of cable. After laying the cable, the road should be filled as per surrounding and make it to original position by tar/cement etc.
202Running/laying of power cable /CAT cable / OFC through PVC pipes.
203Chipping of masonry wall and making groove for laying PVC pipe and replastering the same with required sand & cement to make it original as before (for brick wall) as per the instructions of supervisor at site.
204Survillance System@ ATP and DMM
205Full HD Fixed Box Type IP Colour Camera with varifocal Lens along with Housing and Mount
206P/T/Z (Pan/Tilt/Zoom) IP Colour Camera
207Network Video Recorder (NVR) (24 Channel). Make CP PLUS/DAHUA OR Equivalent.
208Surveillance graded Hard Disk: - 8 TB, Make: -Seagate/ Hitachi/ Toshiba OR Equivalent.
209Sony LED TV 55 inch smart TV with networking Specification. Firm"s offered Make/Brand - Sony/Samsung/ LG or similar
2108 port Layer 2 POE switch with SEP 2 nosMake/Brand - DLink/DG Link/Dahua/CP Plus or similar
211RJ 45 connector Make: D-Link OR Equivalent.
212PVC pipe (ISI Mark, 1 inch Dia) and other sandry materials will be supplied by the contractor. Make: - Anchor OR Equivalent
213Spike Buster (5 way). Make- Anchor OR Equivalent
214Metal camera protection box with all accessories for fixing. Firm"s offered Make/Brand - CP Plus/Dahua or similar
215Computer Table size in (LXBXH) mm: 1000x660 x700 mm, Keyboard Pullout tray, drawer & top.
216Supply and Installation of Fibre Distribution Management system as per RDSO Specification No. RDSO/SPN/TC/37/2020 Rev.4 or latest & as per Sr no. 8.0 of Technical Specification mentioned in Annexure-VII and splicing of optical fibre cable 24 fibre on the splice tray with provision of taking out required fibre of OFC. Pig tail with connector etc. as per technical specification attached and advised by railway engineer at site as per TEC Spec. no. G/OFJ-01 June 1999 in 10 mtr & 5 mtr length as per requirement, shall be supplied by contractor .The system shall be supplied along with rack of size 2200 mm x 900 mm x 400 mm as per drawing no. Dy CSTE/Con/W-2004 (MW) 39
21719 inch 6 U wall mount rack Make- Dlink OR Equivalent Firm"s offered Make/Brand - Dlink/CP Plus AC distribution box 5X5 amps - 1 No; Front panel H/W PKT of 10 Sets - 1No; Make:- APW President/ Make/Brand - Dlink/CP Plus or similar
218Supply & installation of 9U/500mm rack with Fan Drive with 1 AC Fan, mounting tray-1 no, Horizontal cable manager – 1 No, 1 nos of 6 point AC Distribution box, etc,. Make: HCL, NETRACK, Vero president or similar
219ADSL Modem with splitters. Make Dlink/TP Link OR Equivalent
220Supply of SC-LC to SC-LC patch cards (10 mtrs length)
221Supply of SC x SC 3 Meters Patch Cord Make: Bestnet/Fibrain or silmilar
222Supply of media converter single mode dual fiber with built in AC power supply , unit supports 100 Mbps with driving distance of 15 Kms with SC type connector and 10/100 Mbps Ethernetsuitable to the 64 channel NVR port of model FACT01/SA/SM15 /SC/AC of MROTEK MAKE or similar
223Installation/Networking/Testing and commissioning of all Cameras/Networking equipment/Server/Storage device/Power supply system with required video cables etc., including Soft ware and training of nominated staff and Intigrating with the existing system.
224Installation, testing and commissioning for CCTV system complete and system integration charges with 2 Hrs. on site user training with manual. This work includes fixing of PVC pipe and laying of OFC/CAT-6 cable inside PVC pipe Standard
225Fixing of PVC pipe/casing-caping on wall/structure anddrawal of Data cable through PVC pipe. Standard
226Provision of G.P.S. Clock system @ ATP and DMM
227Supply of Double faced digital Clock 4 Digits (Platform Clock) outdoor and indoor with GPS Synchronization as per RDSO Spec. No. RDSO/SPN/TC/62/2008 Rev.3.0 or latest. (The rate is inclusive of GPS receiver with connecting RF cable up to a length of 30 mtrs) Stand Alone Mode.
228Supply of Digital platform clock 4 digits with GPS synchornization ,Single faced confriming to RDSO/SPN/TC/62/2008 Rev 3.0 Amndt 1 or Latest
229Electrical and Mechanical fiitings such as switches, switch boards,plugs,sockets ,spikes buster,screws,bolts,nuts,hangers,bends elbows,etc.as per instruction at site incharge
230Provision of P A SYSTEM arrangements at ATP and DMM stn"s
231Supply ofhigh power amplifier Two zoneamplifier (350W +350W)TZA 700 Watt(7000 watt capacity suitable for voltage matching/impedance matching as per tech spec. Make- Ahuja/phillips/shure/BOSCH/Yamaha/Crown
232Supply of Horn speakers similar to UHC 30XT max 30 Watt or better adjustable from 5 watts to 30 watt in steps Make- Ahuja/phillips/shure or similar
233Supply of PA column speakers model ASC-20T ofAHUJA make or equivalent
234Supply of PA cabinet speaker with rotary swicth volume control 100V of model WS-664T of AHUJA make or equivalent.
235Supply of Goose neck PA microphones, robust construction and excellent performance, Model AGN-500 of Ahuja make or equivalent
236Supply of PA Microphone Stand resistant to rust, superior quality of chrome plating to Specifications: Type:TableStand, Height:130 mm, Base Dia: 120 mm, Model ATS-5 Make :AHUJA or equivalent.
237Installation,Testing and commissioning of face to face PA system as per technical specification and the instruction of superuisor at location.
238Supply of PA amplifier, operation 80 WATTS WITH 5 MIC & 2 AUX INPUTS, of model: SSB80 M of AHUJA make or equivalent.
239Provision of Exchange IP Based Unified Communication Server @ ATP and DMM Stations
240Supply, Installation and Commissioning of IP Based Unified Communication Server Supporting Virtualization in Active-Active Cluster Mode and integrate with Gateways As Per Specification given in Annexure-XVIII
241Server Configuration : Two (2) Nos With One Monitor (i)Intel Xeon E3- 1220v5* core) 3.0 Ghz Cache 8 MB Turbo,4C/4T,80W ii)8 GB RAM iii) 2*1000 GB SATA 7200 RPM Hot-Plu iv) DVD -RW Drive ,OS DOS v) ON Board SATA RAID Controller vi) DUAL GIGABIT LAN vii)Power Supply : Dual Hot-Plug Redundant DC Power Supply (1+1),250 Watts - 48 VDC Only. viii) Mother Board : OEM/INTEL Original Mother Board. ix) 18.5" LED E2016H Monitor. x) Standard Key Board and Mouse Make DELL/HP
242Analog Gateway/Extension user Licences - 128 Nos
243Analog Gateway Hardware with 96 Ports fully with oatch panels /MDF with Krones
244IP End Point Licences 10 Nos
2453rd Party IP SIP Licences - 5 nos (Facilty to connect Third Party SIP Phones)
246Soft phones Lincenes 05 Nos
2472 Ports PRI Gateway with SIP Trunks /IP Net Licences - 2 Nos
2488 Port FXO Gateway with SIP Trunk Licences for CO Lines -01 Nos
249SIP Based IP Phones- 5 nos
250Emergency Room Communication Console Licences and Hardware - 1 No As Per Specification in anexure -X
2512X120 Party Confrence Licenes
252Min 5 Nos of Contact center Voice Agents Licences
25319" 42 U Rack for Server and Gateways -1 No
25424 Port Manageable Gigabit L2 Plus Switch with Minimum 2 SFP Ports -2 Nos
255IDF with Krone Modules and necessary connecting Cables 200 Port
25624 Ports Voice Patch Panels 12 Nos /MDF with Krone Modules150 Ports
2578 Port FXS Gateway
258Supply of SC-PC to SC-PC patch cards (5 mtrs length) with o db coupler.
259Supply of SC x SC 3 Meters Patch Cord Make: Bestnet/Fibrain
260Supply of Push button Telephone with Caller ID facility similar to Beetal Marvel Clip Plus
261Supply of Push Button Telephones
262Supply of 3 Pair Switch Board Cable
263Supply of 10 Pair Switch Board Cable
264Supply of 6 Pair Switch Board Cable
265Supply and Installation of 200 Pair IDF with Krone Modules and Termination of Necessary 25 Pair PVC trough Proper Channeling in IDF
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail