| 1 | Supply & fix wall mounted cabinet made by 1st class hard wood of dimensions 50x37.5x97.5 cm consist of two shelves including fittings and fixtures i.e. magnetic snap closures hinges, handle and hasp & staple with provn of fixing on wall with brackets and fasteners of material prelaminated 17 mm thick MDF board of dark shade complete all as specified and as directed byEngineer-in-Charge.Note:- (i) All built-in and/ or other fittings items for wall mounted cabinet, magnetic snap closures hinges, handle and hasp & staple etc alike all as shown on drawing.(ii) if not shown on Drg but actually required at site will be provided at site by the contractor without any extra cost to Govt. The size,shape & spacing of wall mounted cabinet shall be as directed by Engineer-in-Charge at site and contractor shall have not claim to this effect.(iii) Bidder shall refer the drawing on Page no 106 of tender document before quoting the rate of this item. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and as directed byEngineer-in-Charge. |
| 3 | Material & labour for providingcement concrete 1:2:4,type B2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed byEngineer-in-Charge. |
| 4 | Supply & fix 125 mm dia mild steel pipe(Tubular) fixed as vertical post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 as in posts complete all as specified and as directed byEngineer-in-Charge. |
| 5 | Supply & fix 40mm dia Steel workas Rafters and web in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and fix 32mm dia Steel work as struts and strings in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply & fix rolled sections of angles having size 75x75x6mm as purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates in Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply & fix 10mm thick Mild steel plates, plain or chequered, having size 200mmx200mmin Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply & fix Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply & fix mild steel for wind ties of size 25mm x 5mm for roof including securing bolts ,incuding cutting tops to shape as directed , drilling holes and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply & fix preperation of new or prevously untreated steel surfaces of any description over 10cm in width or girth ,not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 12 | Surface dressing n exc 15 cm deep in soft/ loose soil including Site Clearance complete all as specified and directed by Engineer-in-Charge. |
| 13 | Material & labour for providing 100 mm thick Cement concretetype D-2, 1:4:8 using 40 mm graded stone aggregates in subbase/ floor complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material & labour for providing 100 mm thick Cement concrete B-1, 1:2:4(using 20mm graded stone aggregate) in and as floor complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material & labour for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfacecomplete all as specified and directed by Engineer-in-Charge. |
| 16 | Material & labour for providing Cement concrete type C-1, 1:3:6(using 20mm graded stone aggregate) in and as approach path in rounded or chamfered on edges as plinth courses including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and Fixingwall mounted decorative ultra slimLED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution20 W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per Make Havells or equivalent in Orient/Philips/Bajaj/CG complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fixing LED Flood lighs, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light with high power 120 Watt LEDs as light source, suitable for highlighting architectural facade highmast and general lighting having LED in built control gear including up to 2.5 mtr twin core copper conductor for connection of flood light fitting from LT OH line/ ceiling rose /cable complete all as specified and directed by Engineer-in-Charge. Make :- Havells or equivalent in Philips / CG/C & S / Bajaj / Wipro |
| 19 | Supply & fix double doorSheet metal enclosures factory made DBsprotection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 8 ways with 200 Amp rated bus bar 240 volts powder coatedcomplete all as specified and directed by Engineer-in-Charge.(Make : Havell\"s, L&T, Standard,Crompton/Indoasian) |
| 20 | Supply & fix MCB/Isolator TPN of 415 Volts 63 Amp capacity, \"C\" series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge. (Make : Havell\"s, L&T, Standard,Crompton/Indoasian/legrand) |
| 21 | Supply & fix MCB/Isolator SPN of 240 Volts 40 Amp capacity, \"C\" series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge. (Make : Havell\"s, L&T, Standard,Crompton/Indoasian/legrand) |
| 22 | Supply & fix MCB/Isolator SP of 240 Volts 10 Amp capacity, \"C\" series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge. (Make : Havell\"s, L&T, Standard,Crompton/Indoasian/legrand) |
| 23 | Supply & fixSheet Metal Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB of 32 Amps, 10 KA, 415 volts complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply & fix SwitchSocketCombination 5 in 1,6/16A, flush type universal complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply & fix PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 95 sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 35 sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. |
| 28 | Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material & labour for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches well ramming and spreading in layerscomplete all as specified and directed by Engineer-in-Charge. |
| 30 | Supplying and laying un-reinforced precast concrete cable cover class LV, type - 2, flat, size 300x 180 x 40 mm complete all as specified and directed by Engineer-in-Charge. |
| 31 | Returning and filling including spreading, levelling, watering and well rammingin layers not exceeding 25 Cm thick complete all as specified and directed by Engineer-in-Charge. |
| 32 | Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directedat a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 16 sqmm, 4.0 corecomplete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 16 sqmm, 2.0 core complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply, laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4.0 sq. mm 2.0 core nominal cross section in service connectionscomplete all as specified and directed by Engineer-in-Charge. |
| 36 | Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6.0 Sqmm single core, copper conductor drawn through PVC Casing capping and 6.0 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engineer-in-Charge. (Note: Two runs of conductor with one run of earth wirewill be measured & paid as one unit) |
| 37 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means ofnut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge including testing on completion including the material and labour of the following : -(a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 38 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron strip 25X4mm as earth lead by means ofnut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour of the following : -(a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 39 | Supply & fix Rigid non-metallic PVC conduit of size 25mm exclusive of boxes (junction /terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply & fix of tubes light grade of 40 mm bore galvanised with all fitting for cable protection trenches/ wall/ on pole including necesarry clamps sets and nut & bolts etc complete all as specified and directed by Engineer-in-Charge. |
| 41 | Design, supplying, installing, testing and commissioning LT outdoor type feeder piller box, factory fabricated cubical kiosk type whether vermin proof with IP-65, CPRI approved with locking arrangement and made out of MS sheet 3.15 mm thick suitable size of channel for base complete with 200 Amps rated copper bus bar chamber inc cable gland of suitable size and adequate nos and cabinet for housing mounting 01 No 200 AmpMCCB, \"C\" series 36 KA 4 pole 415 Volts and duly powder coated mounted on PCC (1:4:8) platform commisioning washer chamber and panel board fixing an angle iron frame which is made out of 40 x 40 x 6 mm thick angle iron duly marked the incoming outgoing controls. etc complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply & fix GI tubing 25 mm bore, medium grade, ISI marked, withand including all fittings such as bends, elbows, tees, short pices etc compelete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 43 | Cutting & screwing extg steel tubing of size 25 mm dia for alterations or additions or lengthening screw on pipe to form connector and done in position without taking down complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply & FixGun-metal, globe or gate valves 25mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |