Development Of Distribution Infrastructure Of Packageazamgarh At Azamgarh, Mau And Ballia District Of Puvvnluttar Pradesh Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service Cable For Consumer Service Connection With Accessories As Per Technical Specifications, Scope Of Works And Approved Drawings 3 Supply Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 4 Supply Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 5 Supply Of 10 Swg Gi Wire 6 Supply Of 8 Swg Gi Wire 7 Conversion Of Existing Lt Lines On Bare Conductor To Areal Bunch Xlpe Cable 8 Conversion Of Existing Lt Lines With Bare Conductor To Ab Xlpe Cable Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 9 Supply Of 8.5 M / 180 Kgs Pcc Poles ( Pcc Pole As Per State Practice ) 10 Galvanized Stay Set For Lt Line With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 1 Nos Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 11 Conversion Of Existing Lt Lines Using New Earthing As Per Approved Drawings, Technical Specifications And Scope Of Work 12 Supply Of Spike Earthing Made Of 20Mm X 2500 Mm Gi Solid Rod 13 Supply Of 8 Swg Gi Wire For Earthing And Guarding 14 Supply Of Following Lt Ab Xlpe Cable For Conversion Of Existing Lt Bare Conductor Line With Ab Xlpe Cable As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 15 Supply Of Aerial Bunchedxlpe Cable 3 X 50 Sqmm+1X35 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 16 Supply Of Aerial Bunchedxlpe Cable 3 X 70 Sqmm.+1X50 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 17 Supply Of Aerial Bunchedxlpe Cable 3 X 95 Sqmm.+1X70 Sqmm. ( Bare Messenger Wire ) + 1X16 Sqmm. 18 Supply Of Aerial Bunchedxlpe Cable 3 X 120 Sqmm. + 1X95 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 19 Supply Of Pole Mounted Lt Distribution Box As Per Approved Drawings, Technical Specifications And Scope Of Work 20 Supply Of Three Phase Smc Distribution Box With Clamps 21 Supply Of Single Phase Smc Distribution Box With Clamps 22 Supply Of Xlpe Insulated Al. Cable For Energisation Of Distribution Box / Kiosk As Per Approved Drawings, Technical Specifications And Scope Of Work 23 Supply Of 1X25 Mm2 Xlpe Insulated Al.Cable 24 Supply Of Stone Pad ( 300X300x75 ) 25 Supply Of Accessories For Ab Xlpe Cable As Per Approved Drawings, Technical Specifications And Scope Of Work 26 Stainless Steel Strap 27 Hdg Lt Pole Clamp With Nut & Bolt For Laying Abc 28 Dead End Clamp With I-Hook ( Insulated ) 29 Suspension Clamp With I-Hook ( Insulated ) 30 95 / 35 Sqmm - 70 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 31 120 / 50 Sqmm - 95 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 32 Lt Insulation Piercing Connector 120-50 Sqmm - 50-25 Sqmm Size ( For Energizing Distribution Box ) 33 Lt Insulation Piercing Connector 120-50 Sqmm - 120-50 Sqmm Size ( For Line To Line Jumpering ) 34 Lt Insulation Piercing Connector 16 - 25Sqmmsize Suitable For Street Light Connection 35 Pre-Insulated Compression Connectors Size 16 Sqmm Suitable For Ab Xlpe Cable 36 Pre-Insulated Compression Connectors Size 50 Sqmm Suitable For Ab Xlpe Cable 37 Pre-Insulated Compression Connectors Size 70 Sqmm Suitable For Ab Xlpe Cable 38 Pre-Insulated Compression Connectors Size 95 Sqmm Suitable For Ab Xlpe Cable 39 Pre-Insulated Compression Connectors Size 120 Sqmm Suitable For Ab Xlpe Cable 40 Heat Shrinkable Type End Cap For Ab Xlpe Cable 41 Supply For Augmentation Of Lines 42 Supply For Augmentation Of 33 Kv Line 43 Supply For Augmentation Of 3 Phase 33 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 44 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 45 Supply New Pre-Fabricated Hot Dip Galvanized Steel Item, For Augmentation Of 33 Kv Line, Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle ( 65X65x6mm ) , Ms Flats ( 65X8mm ) Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 46 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding Etc. As Per Technical Specification, Approved Drawings And Scope Of Work. 47 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 48 Supply Of 33 Kv Danger Board 49 Supply Of Gi Barbed Wire 12 Swg 50 Supply For Augmentation Of 3 Phase 33 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material, Aluminum Tape And Helical Preformed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 51 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 52 Supply Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 53 Supply Of 33 Kv Under Ground Cable As Per Technical Specification, Approved Drawings And Scope Of Work. 54 Supply Of 3Cx300 Sqmm 33 Kv Xlpe Armored Cable 55 Supply Of 33 Kv3cx300 Sqmm Xlpe Armored Cable ( 2 Nos Including One Spare ) Accessories Like 160Mm Dia Hdpe Pipes For Road Crossing And 150 Mm Dia Gi Pipegrade B For Pole Support Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cablepath Markers, Bi Metallic Clamps And 7 / 20 Gi Wire As Per Technical Specification, Approved Drawing And Scope Of Work 56 Supplyof New Insulator And Hardware For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work 57 Supply Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 58 Supply Of 33 Kv 10 Kn Polymer Pin Insulators 59 Supply Of New Earthing Arrangement For Augmentation Of33 Kv Line As Per Technical Specifications, Approved Drawings And Scope Of Work. 60 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 61 Supply Of New Stay Set ( Galvanized ) For 33 Kv Line With 50X8 Mm Stay Clamp, Guy Insulator, Anchor Plate ( 300X300x8mm ) , Nut Bolts, Turn-Buckles, 1.8 M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 62 Supply Of New Gi Wire For Earthing And Guarding For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work. 63 Supply Of 6 Swg Gi Wire 64 Supply Of 8 Swg Gi Wire 65 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 66 Supply Of Pg Clamp For Dog To Dog Conductor 67 Supply Of Pg Clamp For Panther To Panther Conductor 68 Supply For Augmentation Of 11 Kv Lines 69 Supply For Augmentation Of 3 Phase 11 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 70 Supply Of 8.5 Meter Long / 180 Kg Pcc Poles ( Pcc Pole As Per State Practice ) 71 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Flats Pole Extension Canal With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 72 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding Etc. As Per Technical Specification, Approved Drawings And Scope Of Work. 73 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 74 Supply Of 11 Kv Danger Board 75 Stone Pad ( 300X300x75mm ) 76 Supply Of Gi Barbed Wire 12 Swg 77 Supply For Augmentation Of 3 Phase 11 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material And Helicon Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 78 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 79 Supply Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 80 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 81 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 82 Supply Of 11 Kv 45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 83 Supply Of 11 Kv 5 Kn Polymer Pin Insulators 84 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 85 Supply Of Gi Earthing Spike Made Of 20X2500mm Solid Rod 86 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, Guy Insulator, Anchor Plate ( 200X200x6mm ) , Nut Bolts, 1 No Turn-Buckles, 1.8 M Long 16 Mm Diameter Solid Gi Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 87 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 88 Supply Of 6 Swg Gi Wire 89 Supply Of 8 Swg Gi Wire 90 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 91 Supply Of Pg Clamp For Weasel To Weasel Conductor 92 Supply Of Pg Clamp For Dog To Dog Conductor 93 Supply Of Pg Clamp For Rabbit To Rabbit Conductor 94 Installation Of Dt Capacitor 95 Supply Of Dt Capacitor With Fitting As Per Technical Specification, Approved Drawing And Scope Of Work 96 Supply Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 97 Supply Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 98 Supply Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 99 Supply Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 100 Supply Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 101 Supply Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 102 Erection Part 103 Installation Of Consumer Service Cable 104 Installation Of Armored Consumer Service Cable With Accessories Including Dismantling Of Existing Service Cable As Per Technical Specifications, Scope Of Works And Approved Drawings 105 Installation Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 106 Installation Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 107 Gi Wire 8 Swg 108 Gi Wire 10 Swg 109 Erection For Conversion Of Existing Lt Lines On Bare Conductor To Aerial Bunch Xlpe Cable 110 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil Of Following Pole As Per Scope Of Work, Approved Drawings And Specifications: 111 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 112 Erection Of Following Types Of Poles For Lt Overhead Line With Stone Pad, Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Pole Numbering By Paint With Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 113 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Stone Pad As Required - ( State Practices Of Pcc Pole And Stone Pad To Be Used ) 114 Excavation Of Lt Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 115 Normal Soil 116 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 117 Removal Of Existing Lt Bare Line Conductor & Fixtures, Depositing To Stores Of Employer And Erection, Testing & Commissioning Of New Areal Bunched Xlpe Cable, Fixing Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral, Piercing Connectors Type-I & Type-Ii, Pre- Insulated Compression Connectors, 16 Mm Dia Ms Nuts & Bolts, Pole Clamps, Stainless Steel Strap, Single And Three Phase Pole Mounted Distribution Board, Energisation Of Distribution Box Through 1X25 Sqmm Xlpe Cable Fixing End Cap Etc. As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 118 Erection Of Aerial Bunched Xlpe Cable3 X 50 Sqmm +1X35 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 119 Erection Of Aerial Bunched Xlpe Cable 3 X 70 Sqmm +1X50 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 120 Erection Of Aerial Bunched Xlpe Cable 3 X 95 Sqmm +1X70 Sqmm ( Bare Messenger Cum Neutral ) + 1X16 Sqmm 121 Erection Of Aerial Bunched Xlpe Cable 3 X 120 Sqmm+ 1X95 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 122 Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications 123 Erection Of 8 Swg Gi Wire For Earthing As Per Approved Drawings, Scope Of Work And Technical Specifications 124 Erection For Augmentation Of Lines 125 Erection For Augmentation Of 33 Kv Line 126 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 127 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 128 Erection Of Following Types Of Additional Poles Matching With Existing Line Supports By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Red Oxide & Aluminum Painting Including Paint, Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 129 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 130 Excavation Of Stay Pit For 33 Kv Stay In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 131 Normal Soil 132 Erection Of Complete Stay Set With Gi Stay Wire ( 7X4.00 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.3 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 133 Erection, Testing And Commissioning Of 33 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 134 Erection Of 33 Kv 10 Kn Pin Insulator With Gi Pin 135 Erection Of 33 Kv 70 Kn Disc Insulator With Strain Hardware ( Set Of 3, 11 Kv Disc Insulators ) 136 Erection, Testing & Commissioning Of New Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 137 Dismantling Of Existing Overhead Line Conductor And Fittings, Depositing The Dismantled Material To EmployerS Store And Laying Out & Stringing Of New Acsr Conductor Of Following Sizes By Providing Jointing Sleeves, Binding Wire & Tape & Helical Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 138 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 139 Stringing Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 140 Erection, Testing & Commissioning Of 33 Kvunder Ground Cable By2 Nos ( Including One Spare ) 3Cx300 Sqmm Xlpe Armored Cable, Using 160 Mm Hdpe Pipe At Road Crossing, 150Mm Dia Gi Pipes For Cable Support, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cable Markers, Clamps, Jumpering, Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 141 Erection For Augmentation Of 3 Phase 33 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 142 Erection Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 143 Erection Of 33 Kv 10 Kn Polymer Pin Insulators 144 Erection, Testing & Commissioning Of Earthing As Per Technical Specifications, Approved Drawings And Scope Of Work. 145 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 146 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 147 Erection Of 6 Swg Gi Wire 148 Erection Of 8 Swg Gi Wire 149 Erection For Augmentation Of 11 Kv Lines 150 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 151 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 152 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 153 Erection Of 8.5 M / 180 Kgs Pcc Poles Withbase Stone Pad ( State Practices Of Pcc Pole And Base Plate / Stone To Be Used ) 154 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 155 Normal Soil 156 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 157 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 158 Erection Of 11 Kv Pin Insulator With Gi Pin 159 Erection Of 11 Kv Disc Insulator With Strain Hardware 160 Dismantling Of Existing Overhead Line Conductor & Fittings And Depositing To EmployerS Store, Laying Out, Tensioning, Binding Of New Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 161 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 162 Stringing Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 163 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 164 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Hdg Ms Nuts, Bolts & Washers As Per Technical Specification, Approved Drawings And Scope Of Work. 165 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 166 Erection Of 5 Kn 11 Kv Polymer Pin Insulator 167 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 168 Earthingand Guarding Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 169 Erection, Testing & Commissioning Of Spike Earthing 20Mm Solid Rod 170 Erection Of 8 Swg Gi Wire For Earthing And Guarding 171 Erection Of 6 Swg Gi Wire For Earthing And Guarding 172 Erection Of Dt Capacitor 173 Erection, Testing & Commissioning Offollowing 440 Volt Lt Shunt Capacitor Including Mounting Structure And Accessories As Required As Per Technical Specifications, Approved Drawings And Scope Of Work. 174 Erection Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 175 Erection Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 176 Erection Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 177 Erection Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 178 Erection Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 179 Erection Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 180 Words