Special Repair To Bldg P-89 ( Married Accommodation ) And P-128 ( Jcos And Ors Institute ) And Provision Of Ceramic Floor Tiles At Np-2, Np-3, Np-4, Np-5, Np-6 And Np-7 ( Married Accommodation ) At Hq 31 Weu Under Ge ( Nw ) Mankh, mankhurd-Maharashtra

Military Engineer Services-MES has published Special Repair To Bldg P-89 ( Married Accommodation ) And P-128 ( Jcos And Ors Institute ) And Provision Of Ceramic Floor Tiles At Np-2, Np-3, Np-4, Np-5, Np-6 And Np-7 ( Married Accommodation ) At Hq 31 Weu Under Ge ( Nw ) Mankh. Submission Date for this Tender is 09-06-2022. Building Repair Tenders in mankhurd Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

32206826
Corrigendum : Special Repair To Bldg P-89 ( Married Accommodation ) And P-128 ( Jcos And Ors Institute ) And Provision Of Ceramic Floor Tiles At Np-2, Np-3, Np-4, Np-5, Np-6 And Np-7 ( Married Accommodation ) At Hq 31 Weu Under Ge ( Nw ) Mankh
Open Tender
Indian
Maharashtra
mankhurd
09-06-2022

Tender Details

Special Repair To Bldg P-89 ( Married Accommodation ) And P-128 ( Jcos And Ors Institute ) And Provision Of Ceramic Floor Tiles At Np-2, Np-3, Np-4, Np-5, Np-6 And Np-7 ( Married Accommodation ) At Hq 31 Weu Under Ge ( Nw ) Mankhurd

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-May-2022 AMENDMENT Fee 02-06-2022
2 21-May-2022 REVISED BOQ BOQ 02-06-2022
3 02-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : SPECIAL REPAIR TO BLDG NO P-89(MARRIED ACCOMMODATION) AND P-128(JCOs & ORs INSTITUTE) AND PROVISION OF CERAMIC FLOOR TILES AT NP-2,NP-3,NP-4, NP-5, NP-6 AND NP-7(PO"S MARRIED ACCOMMODATION) AT HQ 31 WEU UNDER GE (NW) MANKHURD
Sl. No. Item Description
1Taking down cement plaster on brick or concrete surfaces etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed.
2M&L for rendering 15mm thick on fair faces of brickworkor concrete surfaces in CM 1:6, finished the surfaces even & smooth including putty finish complete all as specified.
3M&L for rendering 20mm thick in cement mortar 1:4 on brick or concrete surfaces, on walls, laid in two layers, 1st layer 15mm thick and finishing layer 5mm thick mixed with integral water proofing compound @2 % by weight of cement content of finishing layer, finished fair and even without using extra cement , additional thickness provided as floating/setting coat, including all necessary scaffolding / staging as required complete all as specified and as directed
4M& L rendering 10 mm thick in CM 1:3 on ceiling surface finished even & smoothfinish complete all as specified.
5Supply only integral water proofing compound
6Chipping, removing carefully loose/damaged concrete including plastering (total thickness upto 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
7M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) ORPolymer mortar HB of Dr Fixit, upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
8M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit while the bonding agent is still tacking, exceeding 20mm thickness and not exceeding 40mm thickness in two layers,each layer not exceeding 20mm, including levelling, profiling etc, complete all as specified and directed.
9M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner" of "Pidilite" OR "Shali Rustoff" of "STP Ltd", on rebars with time interval of 1 hour between the coats, complete all as specified and directed. [Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.]
10M&L for Anticorrosive Treatment to Reinforcementusing IPNET-RB of M/s Krishna Conchem orEpoxy Zinc Primer of M/s. Dr. Fixitby application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat.The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed. Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.
11M & L preparing new surfaces of wallsapplying two coat of oil bound distemper over3mm thick wall care putty complete all as specified & directed by EIC.
12M& L forpreparation ofnewly plastered surface and applyingthree coat of white washon ceilings complete all as specified and directed
13M & L for preparing old decorated surfaces of wall (plasterered or unplastered or previously white washed) & applying two coat of oil bound distempercomplete all as specified.
14M & L for preparing old decorated surfaces of ceilings(plastered or unplastered or previously white washed) & applying three coats of whitewash complete all as specified.
15Material & Labour for preparation of old/new plastered surfaces of wallapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed.
16S & Fin repairs harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc
17S & F in repairs Vitreous China wash basin, white, flat back, size 580x450 mm including brackets, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
18S&F floor door stopper aluminium bodyover length of cover plate 140 mmand tonque anodised with hard drawn steel springfixed in floor complete all as specified and directed.
19S&Fbevellededge mirrorof 600x450selected quality mounted on 6 mm thick AC building boardcommercialplyand fixed to wooden plugswith chromium plated screws ad cup washers complete all as specified and directed.
20Taking down carefullyaluminium sliding window shutters including existing rubber gasket completed and re-fixing the shutters same in existing position after replacement of broken glass/stainless steel wire meshwith rubber gasket andarea of window exc 1.20 sqm but not exc 3.78 Sqm in eachincludingnecessary scaffolding etc complete all as specified and directed.
21Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fixNew locking arrangement in place of old oneand re-fixing the sameshutersin existing position after repair work or replacement of new locking arrangementand necessary scafolding etc complete all as specified and directed
22S&F standard aluminum section powder coated in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc including taking down and removal from site complete all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment.Cost of other consumables required for the item shall be deemed to be included in the quoted rate.However glass panes / Bakelite sheet / wire cloth / only will be measured and paid separately under respective items as supply only.
23S & F in repairs aluminium anodised grill DG-104/DG-10210 mm dia of extruded aluminium section of suitable size and frame including fixing with U clip or F section beading complete with all fitting and fixture and drilling required in RCC section in rectangular or arch type balcony opening of the building complete all as specified. (Make:- Deco Grill or equivalent)
24Supply only 3.00 mm thicksheet glass, ordinary quality, in squares not exc 0.5 Sqm each pane, complete all as specified.
25S&F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples Stainless steel wire cloth. 0.36mm nominal dia of wire andverage width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
26Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) not exceeding 1.5 Sqm each including complete all as specified and directed.
27Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) exceeding 1.5 Sqm but notexc4 Sqmeach including complete all as specified and directed.
28Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm and refixing in same opening complete all as specified and directed.
29Taking down shutters of any description n. exc 1 Sqm a refixing in same opening complete all as specified and directed.
30Taking down chowkats or frames not 1.50sqm each refixing in same opening complete all as specified and directed
31Taking down chowkats or frames exc 1.50sqm but n.exc 4 sqmeach refixing in same opening complete all as specified and directed
32S& Fsecond class hard wood , plain ,soild ,straight chowkats and frames, wrought , rebated on soild rounded orchamfered , put together with gule pinnedatjointsetccompleteall asspecified .and directed
33S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with Square tube, supply and fixing in opening as perspecification given under SSR Part II 2010 including making good the disturbed surface all as specified and directed. Make: SYNTEX/SHALIMAR/RAJSHRI
34M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2010 complete all as specified and directed. Make : SYNTEX/SHALIMAR/RAJSHRI
35S&F 35 mm thick plain , framed ,panelled shutters ( any number of panels),in 2nd class hardwood,with panels of timberflat on both sides (feather edged) ,or of veenered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified.
36S & F 35 mm thick glazed and skeleton shutters, in 2nd class hardwood, open rebated and prepared to receive glass, gauze etc, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a)
37M& L for preparation of newly or previously untreated surfaces of wood or wood based surfacesof any description not other wise described , over10 cm width or girth and applytwo coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed.
38M& L for preparation of old surfaces wood or wood based surfacesof any description not other wise described , over 10 cm width or girth and applytwo coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed.
39S&F extruded aluminum alloy handles (150mm ) fabricated type anodised complete all as specified
40S&F hinges (150 mm)stainless steel medium weight complete all as specified
41S&F hinges (100 mm)stainless steel medium weight complete all as specified
42S&F in repairsaluminum anodised barrel tower bolts (150 mm ) of extruded section complete all as specified
43S&F in repairs300 mmAluminium alloy , anodised , sliding door bolt with hasp, staple (bolt type ) and fixing clips of sheet , cast , exctruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified
44Dismantling floor, hearth or wall tiling including cement mortar, bedding removing serviceable tiles to store and rubbish off the premises all as specified and directed .
45M&L non skid colouredceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.16 Sqm but not exceeding 0.38 Sqm, as in floorsoverscreed bed or bedding layer of morar 15 mm in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
46Description all as per Serial item No 45 here-in-above but screed bed or bedding layer of morar 10 mm in cement mortar 1:4 on walls surfaces, such as skirting,to slab etc. complete all as specified and as dircted.
47S& Fcoloured glazed ceramic tiles 350 x 250 x 7mm/450x350x7mm thick in dado/ skiting etc set and jointed in neat cement slurry and pointed in coloured cement to match, over and incl 10mm thick backing coat in CM 1:4complete all as specified anddirected .
48M & L for machine cut cudappah stone slab as in window cills and jambs 20 mm thick to full thickness of wall fixed in steps over cement screed bed 20mm thick in CM 1:4 and jointed with grey cement paste and slurry including rubbing and polishing complete all as specified and directed
49Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations overrendering 10 mm thick in CM 1:6 on brickwork or concrete surfaces complete all as specified and directed.
50S&F in repairs 15mm bore bib taps cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed.
51S&F in repairs 15mm bore stop valve cast copper alloy screwed high pressure with crutch or butterfly handle, screwed both end for iron pipe or for union complete all as specified &directed
52S&F in repairs 15mm bore pillar taps,chromium plated, cast copper alloy screwed high pressure with crutch or butterfly handle, screwed both end for iron pipe or for union complete all as directed.
53S & F in repairs 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
54S&F Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) in repairscomplete all as specified and directed
55M&L Grating dome 100mm dia of PTMT (Minimum weight 25gms) in repairs complete all as specified and as directed.
56S & F PVC connections 15mm size with PTMT nuts of length 450mm
57S&F cast iron Nahani trap 100mm dia out let including grating connecting jointing to waste pipe with lead jointing and taking out existing unserviceable traps by hacking out concrete joints and making good of surfaces complete all as specified and as directed .
58Disconnecting of existing tanks, stacking safely for re-use (or lowering if required) and hoisting, reconnecting and refixing in positioncomplete all as specified.(a) up to 1000 litres capacity.
59S&F in repairGI Steel tubing medium grade with all fitting & fixed complete to walls & ceiling or laid in floors complete including taking down all as specified for the following size :- (a)15 mm bore
60S&F in repairGI Steel tubing medium grade with all fitting & fixed complete to walls & ceiling or laid in floors complete including taking down all as specified for the following size :- (b)20 mm bore
61Fixing only in repair GI steel tubing medium grade with all fitting & fixing to walls/ceiling or laid in floor and complete including taking down all as specified for the following size :- (a) 15 mm bore
62Fixing only in repair GI steel tubing medium grade with all fitting & fixing to walls/ceiling or laid in floor and complete including taking down all as specified for the following size :- (b) 20 mm bore
63S & F in repair 110mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls usingPVC clamps or laid in trenches all as directed.
64All as per item No 63, above but using in repair of75mm diaPVC pipe
65S & F PVC (SWR) bends of 110mm bore
66S & F PVC (SWR) 75 mm dia bend
67S&F 75mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal
68S&F 110mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal
69S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm. complete all as specified and as directed
70M&L for special treatment of sunken portion of WCs and Bath room as per following stages: Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc . Stage 2:- Providing10mm thick plaster in CM 1:4 with chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 3:-Applying Dr Fixit Primseal primer or STP Ltd(and allow to dry for 8 hours) under touch dry condition. Stage 4:-Applyingtwo coats of water proofing decorative elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP(The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufacturer instruction. Stage 5:-Again rendering 10mm thick in CM 1:4 mixed withDr Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 6.All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP. Stage 7:-Making holes in wall and fixing600mm long 20mm dia GI spout for draining the surplus water if any.
71M & L for cement concrete 1:5:10 Type E2 (using 40mm graded stone aggregate) as in filling in sunken floor etc complete all as specified and directed.
72S & F in repair Wash down water closet (Pedestal pattern), complete white (excluding fixing bolts, flushing cisterns and flush pipe) complete all as specified and directed by EIC.
73M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope, benching etc including making rounded or chamfered on edges mixed with WPC as per manufacturer"s instructions, including demolition and removal of existing PCC layer complete all as specified and directed.
74M&L for rendering 10mm thick on fair faces of brickworkor concrete surfaces in CM 1:3, finished the surfaces even & smoothcomplete all as specified.
75Taking down existing treatment any type including cement mortar M & L for APP modified roof treatment over existing roof slab etc including taking downto be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torchapplication with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii)Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv)Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sq cm(v)Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi)Elongation : > 20% in both directions. (vii)Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix)Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%.(d)Over the membrane provide a finishing with solar reflective bitumen aluminium paint @ 0.10 Kg/Sqm as prescibed by manufacturer.
76Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified
77Supply and fixinghot dipped GI imposed grid with 24mm wide T sect exposed flanges powder coated frame work comprising of main runner made from 0.33 mm thick gs sheet of size 24mmx32mmx3000 mm @1200 mm C/C GI wire 4mm dia fixed by rawl plug, level adjusters and screws etc flush fitting of 1200mm long cross tee interlocked between main runners @ 600mm c/c to form 1200mmx600mm modules cross tee longer than 600 mm to be supported independently600mmx600mm modules shall be formed by fitting 600mm long cross tee centrally between1200mm cross tee ,perimeter wallangleshall be GS of size 19mmx19mm and 0.45 mm thick 300mm long including 600mmx600mmx8 to 10mm thick Armstronggypsum reinforced board complete all as specified and directed.
78S&F in repair 18/19 mm thick prelaminated particle boardboth sides , interior grade , of approved shade and pattern fixid with screws to timber frame with beading piece for cupboard and shelves complete including dismantling etc. all as specified
79S & F for 125mm aluminium handles, cast type, anodised complete all as specified and directed.
80M& Lfor Chequeredcement concrete tiles 20cmx 20 cm x 25 mm thick, set, jointed and pointed in near cement slurry in floors with mixture of white cement and no pigment over screed bed or bedding layer of mortar 15 mm in cement mortar 1:6 complete all as specified and as directed.
81Demolition cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed/
82M & L for rendering 15 mm thick in CM 1:6 on brick walls or concrete surfaces finished the surfaces even & smooth incl 1mm thick sagol finish including preparation of old surfaces in patches for repairs at anyplaces inside the bldg complete all as specified and directed.
83M & L preparing new surfaces of wallsapplying two coat of oil bound distemper over one coat of primer complete all as specified & directed
84M& L for preparation of newly or previously untreated surfaces of wood or wood based surfacesof any description not other wise described , over10 cm width or girth and applytwo coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed.
85M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in PCC Bed plates, levelling course Coping, benching etc including making rounded or chamfered complete all as specified and directed.
86Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etcand making good disturbed surfaces of walls/ roof etc, complete all as specified and directed.
87Taking down complete main switches/DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed.
88M & L forpoint wiring with PVCinsulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories andearth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressedsteel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screwsall as specified for one light / fan / bellpoint controlled by one switch.
89-Ditto- all as per item No 88 here-in-above but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches.
90-Ditto- all as per item No 88 here-in-above but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board.
91All as per item No. 88 above but wiring complete with 2.5Sqmm for 3 pin 15A socket multipurpose on independent board
92S&F modular type6A one way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.
93S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
94S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed.
95S&F modular type16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed.
96S&Fmodular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed.
97Supply & Fix Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed.
98Supply and fix bell ding dong AC 230 V single pole.complete all as specified and directed.
99S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed
100S & F Modularcover plate 8 modules
101S & F Modularcover plate 6 modules
102S & F Modularcover plate 4 modules
103S & F Modularcover plate 3 modules
104S & F Modularcover plate 2 modules
105S & F Modularcover plate 1 modules
106S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed.
107S&F in repairs Surface, hanging and wall mounted batten (Double side connection) suitablefor LED tube 20/22 watts, 230 volts alongwith tube rod 20/22 watt (double side connection),including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed
108Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed
109Taking Down Ceiling fans 1200/1400 mm sweep and transporting to store for safe custody for reuse or for depositing at the MES Yard. Note : Unserviceable ceiling fans shall be deposit to MES store.
110Re-fixing of the same ceiling fan 1200mm sweep including provision of cable from ceiling nose/ conductor to fan and spray painting of ceiling fan with two coats of synthetic enamel paint, after preparation of surfaces, complete all as specified and directed.
111M & L for rewinding of ceiling fan of size upto 1200 mm with suitable gauge copper wire, including new bearing and new capacitor complete all as specified and directed.
112Supply and fix fans ceiliing with BLDC motor complete with blade, canopy, down rod, mounting hook, rubber insulator etc, the colour offan shall be of Elegant White/Dubai white/White CF with remote control alongwith batteries and accessories 230 V, 1200 mm sweep, 26/28/32 watt, BEE 5 Star rated complete including takingdown old unserviceable fan all as directed by Engr-in-Charge.Make : Havells (Efficiencia Neo (BLDC 26 W) /Orient /Bajaj/ Panasonic (Captor i-Kraft) Note : Unserviceable ceiling fans shall be deposit to MES store.
113Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers
114S & F MCB DB, 12 way, SPN, double door, 240 Voltsand including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
115S & F MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity
116S & F MCB SP 5 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity
117M&L for sub mainwiring with twosingle core 6.0 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 6 Sqmmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dolly all as specified and as directed Note : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
118M&L for sub mainwiring with twosingle core1.5 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 1.5 Sqmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dollyincluding taking down old unserviceable submain wiring complete all as specified and as directed Note : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
119S&F in repair/replacement of building Security lightfitting 30/35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge.
120S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge
121Supply and fix indoor type vermin and weatherproof totally inclosed cubical type front operated, sufficient ventilation on sides cubicle type fabricated out of 2 mm thick CRCA sheet duly treated with seven tank process and painted epoxy powder coated siemens greycolour and with industrial type built in locking arrangement. The Panel indoor type cubical panel board IP 52 free standing floor mounted(CPRI approved manufacturers).The panel to be prewired with PVC insulated copper conductors appropriate current carrying capacity for connecting the incoming and out going MCCBs and MCBs. including disconnecting the LT panel and taking down the unserviceable cables and including MCBs. Energy meters of the panel shall be taking down and kept in safe custody for re-installation of site. Disconnecting the incoming and out going cable connection and dismantling the unserviceable conventional type industrial meter board and removing from site for further disposal and making LT UG cable connectioncomplete of suitable sizeand comprising of following items:- (a)INCOMER (i)MCCB 40 Amps 415V 16 KA 4 pole - 1 No. Make: Havells/Legrand/indoasian (b) OUTGOING (i)MCB SPN 40 Amps "C" Series - 4 No. Make: Havells/Legrand/indoasian (ii)MCB SPN 20 Amps "C" Series - 2 No.Make: Havells/Legrand/indoasian (iii) Space for fixing of single phase electronic meter - 5 Nos. (c) BUS100 Amps TPN with colour coded heat shrinkable sleeve (d) METERING & INDICATION i) Digital VAF meter with selector switch & 3 Nos ofCT"s -1 Set ii) Indication lamps for R,Y,B phases -1 Set (Set of Three) (e) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled. (f)Manufacturer Name plate and Danger notice board writtenin regional language Hindi and English. Note 1. Layout & specification of panels shall be got approved by GE before placing the order.
122Supply And Fix in repairs MCCB DB TPN 4Way double door125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories, a) MCCB TP 125 A 25 KA 415 Volt - 1 Nos b) Bus bar, Din rail , Neutral link Make -Havells/Indoasaian/Legrand/ABB/Schnider
123S & F MCB DB, 8 way, SPN, double door, 240 Voltsand including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
124S & F MCB DB, 4 way, SPN, double door, 240 Voltsand including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
125S & F MCB DB, 2 way, SPN, double door, 240 Voltsand including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed.
126Supply and fixing post top lantern LED type 20/25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make - Cat Part No. SZPGPMX025 of Shakti or Equillant of Polycab/ Bajaj
127M & L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised MS strip 32 x 6 mm by means of bolts, nuts, check nuts and washers all as shown in Electrical Plate No.3 connected to earthing test point all as specified or indicated including testing on completion or incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification..