Provision Of Rfid Based Boom Barrier And Traffic Signal Provision Of Rfid Based Boom Barrier And Traffic Signal At Chennai Airport, chennai-Tamil Nadu

Airports Authority Of India has published Provision Of Rfid Based Boom Barrier And Traffic Signal Provision Of Rfid Based Boom Barrier And Traffic Signal At Chennai Airport. Submission Date for this Tender is 01-06-2022. Traffic Signals Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

32202402
Provision Of Rfid Based Boom Barrier And Traffic Signal Provision Of Rfid Based Boom Barrier And Traffic Signal At Chennai Airport
Open Tender
Indian
Tamil Nadu
chennai
01-06-2022

Tender Details

Provision Of Rfid Based Boom Barrier And Traffic Signal Provision Of Rfid Based Boom Barrier And Traffic Signal At Chennai Airport

Key Value

Document Fees
INR 1180 /-
EMD
INR 161991.0 /-
Tender Value
INR 80.99 Lakhs /-

BOQ Items

Name of Work: Modernization of Chennai Airport Phase - II, Chennai - Construction of Road in front of Terminal Building - SH: Providing of RFID Based Boom Barrier System and Traffic Light signal at Chennai Airport.
Sl. No. Item Description
1Design, Supply, Installation, Testing and Commissioning of outdoor type RFID based""Electrically opertated electro mechanical boom barrier" the following length OEM supplied aluminium Boom along with Red reflecting strip, Built LED flashing lights, Control panel / Unit housed in weather proof enclosure, Push button control facility for Stand along operation and provision of integration with external access control systes if any, safty boom sensor / DIR photocell pair, release key & leaver arrangement for manual operation, safety & protection accessories, wired remote control / Push Button command switches etc. suitable for operation on 220 - 240 V, 50Hz power supply, Opening / Closing time shall not be more than 6 sec complete etc as required.
2Boom Length = 3 Mtr
3Boom Length = 4.5 Mtr
4All inclusive comprehensive maintenance contract after DLP of 17 Nos complete boom barrier system as here under provided under this contract including all spares, consumables and manpower required for trouble shooting, routine, preventive and breakdown maintenance etc. As required as per good engineering practice, recommendation of the respectivemanufacturer and instructions of engineer - in - charge for maintaining the systems in acceptable functional, operational and servicable state.
51st Year after DLP
62nd Year
73rd Year
84th Year
95th Year
10Supply, Installation, Testing and Commissioning of 3 KVA Online UPS in redundant configuration with SMF batteries for minimum 20 minutes of battery backup, 32 Amps Double pole MCB with DB for change overand complete as per the specification and preferred makes etc as required.
11Providing & fixing of outdoor type enclosure, IP 42 protection, suitablefor 3 KVA Online UPS with SMF batteries etc as required.
12All inclusive comprehensive maintenance Contract of 5 Nos 3 KVA online UPS after DLP as provided above including all spares, consumables and manpower required for trouble shooting, routine, preventive and breakdown maintenance etc. As required as per good engineering practice, recommendation of the respective manufacturer and instructions of engineer - in - charge for maintaining the systems in acceptable functional, operational and servicable state.
131st Year after DLP
142nd Year
153rd Year
164th Year
175th Year
18Dismantling of flexible pavement (bituminous courses) by mechanical means and disopal of dismantled materials and Providing, laying and fixing of 50mmdia G.I. pipe (medium class) in 30 cm deep in ground complete with G.I. fittings and re-filling etc as required
19Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set upto plith level etc including form work upto etc as required.
20Design, Supply, Installation, Testing & commissioning of outdoor type, double doorSub feeder pillar, fabricated out of 2.0 mm steel sheet duly powder coated, dust and Vermin proof for thefollowingincoming, out going, Indication lamps, procelaing connector danger notice plate etc as required including connection of cables i/c supply and installation of brick foundation with plaster for the feeder pillarincluding providing and fixing of MS support for panel base size of 75 x 40 x 6 MM "C" Channel including Cutting, Grinding, welding etc.as required. a). Incomer - 63A FP/25KAMCCB - 01 No b).Out Going 1 - 12 Way SPN DB Double door with 20 Amps Double pole MCB - 06 Nos c). Out Going 2 for UPS - 12 Way SPN DB Double door with20 Amps Double pole MCB - 06 Nos
21Supply of 3.5 core × 25 Sq.mm size of 1.1 KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS : 7098:1988 Part 1 with upto date amendments.
22Supply and Fixing Supply and Fixing of FRLS PVC insulated copper conductor Three core cable and 2.5 sq.mm. FRLS PVC insulated copper conductor in existing surface / recessed steel conduit including dismantling as required 3 core X 2.5 sq. mm.
23Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
24Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
25Supplying and fixing of 6 modules, PVC box alongwith modular base & cover plate for modular switches and Socket in recess etc. as required.
26Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 10 A switch outlet
27Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 6 /16 A socket outlet
28Supplyof Medium bay LED Luminaire with system wattage 70 W, IP65 and system lumen 7000lm. The luminaire efficiency shall be >100lm. The luminaire shall be 4000K-6500K color temperature and having 50000 burning hours life with minimum 70% lumen maintennance. CRI should be greater than 70, housing should be CRCA Sheet of thickness of 0.5-0.6 mm thick. The diffuser shall be opal diffuser, electronic driver should be in built with life of 50000 hrs power factor >0.9 of the inout voltage tolerance shall be 120-270 volt AC complete in all recpect including LED and other accessories as required. (Philips make Model No. BVP141 LED70 CW FG GR PSU or equvalent)
29Supplyof Indoor TypeLED Luminaire with system wattage 15 W and system lumen 1350 lm, of size not les s than ø 200 mm x 68.5 mm. The luminaire efficiency shall be >140lm. The luminaire shall be 4000K-6500K color temperature and having 50000 burning hours life with minimum 70% lumen maintennance. CRI should be greater than 80, housing should be CRCA Sheet of thickness of 0.5-0.6 mm thick with IP20 rating. The SMPS Based constant current supply electronic driver should be in built with life of 50000 hrs power factor >0.9 of the inout voltage tolerance shall be 140-270 volt AC as per IS 15885 Part 2 / Sec 13 complete in all recpect including LED and other accessories as required (Havells make Model No. INTEGRA NEO SURFACE DLS 15W LED 830S or equvalient) .
30Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
31Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. (63 mm dia (OD-63 mm & ID-51 mm nominal)
32Supply of "RED" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
33Supply of "YELLOW" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
34Supply of "GREEN STRAIGHT" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
35Supply of "GREEN RIGHT" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
36Supply of "GREEN LEFT" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
37Supply of "GREEN LEFT "U"" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
38Supply of "GREEN RIGHT "U"" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
39Supply of "PEDESTRIAN RED" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
40Supply of "PEDESTRIAN GREEN" 300 mm dia traffic signal lamp heads hosed in polycorbonate body having high intensity complete as required.
41Installation testing and commissioning of the above traffic signal lamp heads complete as required.
42Supply of 2 1/2 digit count down timer with red and green colour display height 220mm 3 or 2 lines of red and green leds with pole mountable, weather proof, dust and splash proof possivated and powder coated MS 20 Kg cabinet with sun viser, facia should be made up of 2 mm clear arcylic sheet etc as required (Size of 360mm(L) x 80mm(W) x 345mm (H))
43Supply of Microprocessor based automatic/manual traffic controller with police control panel of Pole mounting type complete as required.
44Installation testing and commissioning of the above Microprocessor based automatic/manual traffic controllercomplete as required.
45Supplying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
46Laying of 63mm dia high density polyethlene (HDPE) heavy duty pipe capable of with standing pressure of minimum 5 kg/sqcm through duct made by horizontal drilling in ground (75 cm below ground level) without opening the trench in all type of soil including deploying the HDD machine, mud mixing system , earth movers, etc., complete as perdirection of Engineer - in - charge.
47Supply , Fabrication and Erection of Cantilever 100 mm M.S pole of following 9 Meter [6 Mtr height + 3 length hang ] in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
48Supply , Fabrication and Erection of 100mm M.S pole of following 6 Meterin cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
49Supplyof Copper conductor 1.1 KV grade 4 Core x 4 Sq. mm armouredXLPE insulated cable as per IS 7098 (Part-I) 1988 ammended upto date in the existing HDPE Pipe complete as reqired.
50Supplyof Copper conductor 1.1 KV grade 16 Core x 1.5 Sq. mm armouredXLPE insulated cable as per IS 7098 (Part-I) 1988 ammended upto date in the existing HDPE Pipe complete as reqiredSupplyof 16 core X 1.5mm2Cable in Existing HDPE Pipe
51Supplyof Copper conductor 1.1 KV grade 12 Core x 1.5 Sq. mm armouredXLPE insulated cable as per IS 7098 (Part-I) 1988 ammended upto date in the existing HDPE Pipe complete as reqiredSupplyof 16 core X 1.5mm2Cable in Existing HDPE Pipe
52Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade ofsize Upto 35 sq. mm in the existing RCC/ HUME/ METAL/HDPE pipe as required.
53Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size of upto 35 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
54Supplying and making end termination with brass compression gland and aluminium lugs for size of 4C X 4 sq. mm (17mm) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
55Supplying and making end termination with brass compression gland and aluminium lugs for size of 16C x 1.5 sqmm (23mm) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
56Supplying and making end termination with brass compression gland and aluminium lugs for size of 12C X 1.5 sq. mm (21mm) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
57Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 25 sq. mm (28mm)
58Supply and Fixing of (300 x 315 x 214) size of SMC Box in the existing pole including providing and fixing of suitable clamps
59Supply, Installation testing and commissioning of long cord manual interface controller having relays and signal voltage booster circuit chips with suitable enclosure and necessary mounting clamps for the existing traffic signal lights as complete as required.
60Charges for programmer for programming the signal direction in the microprosser control unit with the help of traffic police etc as required
61Supply of SMPS 24 Volt output and operating at 230 Volts 50 Hz Ac supply etc as required