| 1 | Grading roof for water proofing treatment withwater proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 2 | Finishing with 25 mm thick cement plaster on roofs in cement sand mortar 1 : 4 mix including water proofing compound @ 2% of cement used. with neat cement, finishing, curing etc. complete in all respect including making of 300 mm x 300 mm square. |
| 3 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . |
| 4 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 5 | Providing and fixing of suspended false ceiling in the grid of 600 x 600 mm / 600 x 600 to 900 x 900 mm using aluminium tees with inter lock system of main tee, cross tee and wall angle (size of tee and angle approx. 25 mm x 25 mm or equivalent) etc. complete with G.I. Adjustable suspenders skelton. Ceiling tiles made from multi chamber hollow PVC section having an overall cross section of : - Using 200 x 20 x 1 mm section. |
| 6 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 110 mm dia Bend 87 .5 |
| 7 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 110 mm dia Bend 45 |
| 8 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 110 mm dia Coupler (socket) |
| 9 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor Three level excluding the cost of centering and shuttering. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). |
| 10 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 11 | P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. |
| 12 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 13 | Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 14 | Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portion Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 15 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835. |
| 16 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. |
| 17 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. |
| 18 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete |
| 19 | Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. Old Work |
| 20 | Providing & applying Three coat of Acrylic Water Proof membrane having sunlight and UV resistant propertiesover waterproofing slurry coat , initial coat of 50-75 micron thickness with diluting 1 part of chemical with 2 parts of clean water, overwhich applying 2 coats at 2 Hrs .intervals each with diluting 1 part ofchemical with 20% of clean water for total thickness of 400 to 450 microns (covering area 0.9 Sq.M/Kg of chemical including preparation of surface by cleaning, brushing and dust removing, scaffolding if necessary etc., with contractor\"s labour, tools,machinery etc, complete as directed by Engineer in Charge. |
| 21 | Providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with :Stone slab 40 to 50 mm thick average. |
| 22 | Provinding and laying of paver block as per IS 15658 : 2006 (Indian standerd for Precast concrete block for Paving -specification) and IRC :SP:63-2004(guidelines for the use of interlocking concrete blockPavement) (from BIS approved manufactrersM-30, 50 mm thick to be used in non traffic areas like building Premises,monument Premise, landscapes, Public gradens/Park, domestic drives,paths and patios, Embankment slopes, sand stabilization Area etc.(As per table 1 of IS 15658:2006 Category \"B\"denated only two side like I,Z,T shape etc. as per IRC SP 63:2004 |
| 23 | Providing and filling block rubberized joint filler in all visible cracks of masonry / concrete / terrace concrete blocks / canal lining basement / A.C. / G.I. / sheets roofs gutters down pipes after removing existing treatment and cleaning with wire brush and joint should be free frome dust, loose particle, oil and grease than filling joints with filler putty knife spatula or brook knife and let it dry for atleast 72 hours complete (as per manufacturer specifications). |
| 24 | Flyash Lime Gypsum Brick Works withFlyash Lime Gypsum Brick Works of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |