Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000: 1:3:6 (1Cement :3 Course Sand :6 Graded stone aggregate 40 mm nominal size |
| 3 | Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall IS 1597 (Part-I) 1992 in : Cement Mortar 1:4 (1-Cement:4-Sand). |
| 4 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement.All work up to plinth levelIS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size) |
| 6 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members andremoval of formwork for superstructure up to 4.5 mtr aboveplinth,for:Columns, pillars, posts and struts etc. |
| 7 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members andremoval of formwork for superstructure up to 4.5 mtr aboveplinth,for: Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands , coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc. |
| 8 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding cost of centering shuttering and reinforcement IS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs, girders having slopes up to 15o , landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases, up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good and joints excluding the cost of centering, shuttering and reinforcement IS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size). |
| 10 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Tremo Mechanically treated bars |
| 11 | Half brick masonry in foundation & plinth using bricks of designation 75 with nominal hoop rainforsed (2 Nos. 6mm MS bar) at every fourth course in for hoop rainforcement 1Sqm. 6mm MS bar 2x2x1.00 = 4.00 Cement mortar 1:4 (1-Cement:4-coarse sand). Add extra for half brick masonary in superstructure up to third story. |
| 12 | Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand. |
| 13 | Random rubble dry stone Kharanja under floor. |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth , consolidatingeach deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr. |
| 15 | Earth work in excavation, including stacking/disposal of surplus material with all lifts and lead upto 495 metres, exclusive of compensation of earth [MoRTH specification : Clause 301 to 305] In ordinary Soil Mechanically by power shovel, including mechanical loading and carriageby tipper/dumper (6T capacity) with Carriage of Sand, bajri, ballast, stone, boulders, kankar & gravelly material includind loading & unloading( MORTH specification : 514.5 table 500.28 ) For lead above 495mtup to 1000mt ) to be included in the respective item). with Add for each subsequent Km. Lead above 1 KM. Upto 10 KM. |
| 16 | Polished Blue Kota Stone slab in steps, walls, pillars having fine machine cut edges laid on 12mm (Av.) thick cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete : 30 mm thick slab area upto 2001 to5000 Sq.Cm. |
| 17 | Add extra for mirror polishing onterrazzo / mosaic flooring : New surface |
| 18 | Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing ofIS 3316-1974 : Jhunjhunu / Jalore (Red / Choclate Colour) Size above 3600 Cm2 |
| 19 | Extra for providing edge moulding to 18 mm thick marble stone counters, vantities etc. over item No. 7.1 & 7.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work. |
| 20 | Providing and fixing Ist quality standard White Ivory straight edge Glazed Tiles ISI marked [IS:13753] (Kajariya, Jhonson, Somani make etc. ) of size 450mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). |
| 21 | Providing and fixing Ist quality MAT finished ceremic tile size 300x300mm confirming to IS : 13753 coloured tile expect white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler power (Untile or Roffe make) and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). Add extra for floor work due to extra cost of cement mortar 1:4 (1-Cement:4- fine sand) 20 mm thick. |
| 22 | Providing and laying Chequerred plain cement concrete embossed specially manufactured non-slipping tiles of approved make 20 mm thick laid on 20 mm thick bed of cement mortar 1:6 jointed with neat cement slurry complete. with Add extra for chequerred coloured plain cement concrete or specially manufactured non-slipping tiles of approved make 20 mm thick. |
| 23 | Brick masonary in foundation and plinth with bricks of class designation 75 mm. IS 2212-1991 in :Cement Mortar 1:4 (1-Cement:4-coarse sand). Add extra for brick work in superstructure up to third storey IS 1077-1986. |
| 24 | Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish:20 mm thick. |
| 25 | Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish : 12 mm thick. Add extra for plaster done over ceiling. |
| 26 | Providing and fixing pressed steel mitred door frames manufactured from commercial mild steel sheet of 1.25 mm (16 gauge) thickness including hinges jamb, lock jamb, head and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25 mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile \"C\" |
| 27 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws at not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 28 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formaldehye resin, in glue both sides with approved steel fittings complete as per Annexure ‘A’ IS 2202 (Part I & II) 1999/1983. Commercial Veneer both side 30 mm thick shutter |
| 29 | Add extra for Flush doors For double leaf shutter |
| 30 | Add extra for Flush doors For Internal teak wood lipping in 25mm depth in single leaf. |
| 31 | Add extra for Flush doors For Internal teak wood lipping in 25 mm depth in Double leaf. |
| 32 | Providing & fixing anodizing alumium work (Anodizing to be got done from approved Anodizer) for doors, windows, ventilators and partition with extruded built up standard tubular and other sections of approved make confirming to IS : 733 and IS : 1285 anodised transparent 81 dyed to required shade according to IS : 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gas at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required inlcuding cleat angle Aluminum snap beading for glazing/paneling, C.P. Brass/ Stainless Steel screws, Al. Tower bolt & Al. handle & Al. Aldrop etc. all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and peneling to be paid for separately). For Fixed portion |
| 33 | For shutters of doors, windows & ventilators incl. providing and fixing hinges/ rollers etc. and making provision for fixing of fittings wherever reqd. (lockes shall be paid for separately). |
| 34 | Providing and fixing glazing in aluminium door, window, vintilator shutters and partitions etc. with PVS/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost. of aluminium snap beading shall be paid in basic item.) (A) with glass panes of 4.0mm thickness (weight not less than 10.0 Kg/Sqm) as per IS : 2835 |
| 35 | P&F double action hydraulic floor spring of approved brand and manufacture to aluminium door shutter confirming to IS : 6315 incl. costof cutting floors as reqd. embedding in floor and cover plate etc. complte as per direction of Engineer in charge. |
| 36 | P&F expanded grill made of anodised aluminium as per desing and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminium window/ vent with reqd. screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. |
| 37 | Providing and fixing brass lock without handle for aluminium door, or approved quality, make & design as directed by Engineer inc harge |
| 38 | Providing and fixing sun control film, 25 micron thick of approved colour and shade, complete in all respect at all level, as directed by engineer in charge. |
| 39 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 40 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete |
| 41 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. |
| 42 | Painting with weather coat paint (Asin paint/ I.C.I./Berger or eq. ISI make paint) two or more coat to give an even shade on new work. |
| 43 | Painting with enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work. |
| 44 | Grading roof water proofing treatment with : Cement concrete 1:2:4 (1-Cement:2-coarse sand :4-graded stone aggregate 20mm nominal size). |
| 45 | Providing and laying 20 to 25 mm size glazed tiles pieces for rooof treatment having colour and shade as approved by the Engineer incharge over 25 mm thick layer of cement mortar mix 1:4 with application of cement slurry including finishing of joints with ordinary cement and curing etc. complete in all respect. Washing with acid. |
| 46 | Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design. |
| 47 | Cement concrete flooring grade 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete IS 2571-1970 : (A) 50 mm thick with 20 mm thick nominal size aggregate. |
| 48 | Supply & fixing of stainless steel pipe railing for ramp railing height, 90 cm. with 40 mm dia stainless steel pipe with 18 gauge with drop (vertical post) at 90 cm. C/C and intermidiate horizontal pipe with suitable height of same size and gauge with coupling, grinding and polishing & fix of master pieces as per required point as per approved design of Engineer incharge. |
| 49 | Supplying and fixing machine cut and polished stone shelves, tands and sills in CM 1:3 with machine cut edges: Kota stone 25 to 30 mm thick. |
| 50 | P&F whie vitreous china double syphonic european WC (IS : 2556 Mark) with mounted WVC flushing cistern of (IS: 2556 Mark) of 10 litre capacity complete with all necessary internal fitting incl. cutting and making good the wall and floor. |
| 51 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall : (A) Size 580 mm x 430 mm |
| 52 | P&F Beveled edge mirror of special glass of appd make (Atul/equivalent) complet with6mm thick asbestos cemetn sheet ground fixed to wooden scrwes & washers. Size 600 x 450mm x 4mm thick |
| 53 | P&F towel rail or ring of approved quality /make: C.P. brass towel rail elbow type with concealed screws size 600mm (heavy duty) |
| 54 | P&F Grating of approved quality/ make Synthetic material (PTMT) of approved quality/ make Square 150x150x8mm (Anti Cockroach) |
| 55 | P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : (A) C.P. Brass bib cock, 15 mm nominal bore. |
| 56 | (B) C.P. Brass Long body, 15 mm nominal bore weight not less than 690 gm.B628 |
| 57 | P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete : Brass wt. 400 gm, 15 mm. |
| 58 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection with 37 Cm. long pipe and nut. |
| 59 | P & F Full-way valve (IS:778 Mark) or wheel valve of approved make : (A) Gun-metal 25 mm nominal bore. |
| 60 | (B) Gun-metal 15 mm nominal bore. |
| 61 | P & F Stop cock (IS:8931 Mark) superiorquality & of approved make : C.P. Brass 15 mm nominal bore. |
| 62 | P & F 15 mm. Dia Connection pipe of approved quality/make: PVC pipe with C.P. Brass nuts up to length 600 mm. |
| 63 | P&F Soap dish or tray of approved quality/ make. C.P. brass heavy and superior quality |
| 64 | P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design. (A) 1000 litres capacity. |
| 65 | Providing and fixing Polyethylene – Aluminium Polyethylene (PE-AL-PE) composite Pressure Pipes U.V. stablised with carbon black conforming to ASTMF – 1282 – 1995 for water supply including cutting and making good the walls etc. Concealed installation including cutting chases and making good the walls etc. complete. 1216 (16 mm OD) pipe |
| 66 | Providing and fixing Polyethylene – Aluminium Polyethylene (PE-AL-PE) composite Pressure Pipes U.V. stablised with carbon black conforming to ASTMF – 1282 – 1995 for water supply including cutting and making good the walls etc. Concealed installation including cutting chases and making good the walls etc. complete. 2025 (25 mm OD) pipe |
| 67 | P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant 75mm dia |
| 68 | 110mm dia |
| 69 | Construction of manhole in all type of soil inner size 90 X 60 Cm. thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring,making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C.flooring , 25 Kg. CI cover with frame of 40mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth upto 0.5mtr Add extra over item 3.21.1 for every addl. 0.10mtr depth above 0.5m depth. |
| 70 | Construction of soakage well in all type of soil 300 mm thick dry masonry top and bottom 300 mm course in CM 1:6, 80 mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring, earth work complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 300 Cm. dia outside & 300 Cm. depth. |
| 71 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work, referAnnexure \"A\" attached . |
| 72 | Short point (up to 3 mtr.) |
| 73 | Medium point (up to 6 mtr.) |
| 74 | Long point(up to 10 mtr..) |
| 75 | Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles, 18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modularswitch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge,making connections, testing etc. complete as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 76 | On board |
| 77 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, referAnnexure \"A\" attached . |
| 78 | MMS ( IS:9537 P - III ) PVC conduit |
| 79 | 25 mm |
| 80 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4,, in existingsurface or recessed PVC/ MS conduit/casing capping includingall as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work, referAnnexure \"A\" attached |
| 81 | 2x 1.5 sq.mm |
| 82 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 83 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 84 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\". |
| 85 | Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 86 | 5 step fan regulator 100 watt 2 Module |
| 87 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load andsite requirement) 4KV impulse withstand voltage,as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted withexisting distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A ratingincluding making connections, testing etc. as required.. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 88 | Single pole MCB |
| 89 | 6 A to 32 A rating |
| 90 | Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thickDistribution board as per PWD specificationfor electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DBterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached |
| 91 | IP-43 Double door (Three phase) |
| 92 | 4 Way ( 12 O/G + 8 I/C ) |
| 93 | Providing & Fixing of 240/415 V isolator as per PWD specification for electrical Works with ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm. , label holding facility , IP 20 contact protection and fitted with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 94 | Four pole Isolator |
| 95 | 63 A rating |
| 96 | Providing & Fixing ofISI marked(IS:2268-1994) ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 97 | P & F 18 swgM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 98 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above , with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x l.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required . Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached . |
| 99 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to <4. 5 ) |
| 100 | SITC of surface mountingtype sheet steel enclosure conforming to IEC 61439-3 of 1.6 mm thick with IK08 and IP 30 protection suitable for 3/4 POLEMCCB having in built neutral link , mounting holes for easy wall mounting including making connections ,testing & etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 101 | Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable |
| 102 | SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders,etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 103 | With Thermal Magnetic release |
| 104 | up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 105 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- |
| 106 | (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I |
| 107 | (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . |
| 108 | (c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached |
| 109 | Armoured Cable |
| 110 | 3.5 core |
| 111 | 35.0 Sq.mm |
| 112 | Labour charges for Excavation of 30cmx75cm size trench in loose soil including refilling of excavatedearth,compaction of earth, making good the same complete as required . |
| 113 | Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. OEM shall be an ISO certified company.Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached |
| 114 | 300 mm sweep |
| 115 | P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached |
| 116 | Up to 380 mm size |
| 117 | Supply & Fixing of ABC Type (MAP 50)type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, withDry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket includinginitial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printedon the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 118 | 6 kg |
| 119 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coatedhousing with in built driver, Power Consumption of18W/20W ,system lumen efficacy = 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.=0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 120 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded |
| 121 | 4\" LED Tube shape fixture 18/20 W (Polycarbonate Base) |
| 122 | Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 123 | Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 124 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cuthimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 125 | 8 SWG G.I. ( Hot Dipped) Wire |
| 126 | Providing& coveringof existing cablelying in existing trench by IInd class bricks/ Stone slab of minimum 32mm thick and 250 mm widein complete running lengthof trenchcomplete as required. |
| 127 | Providing & Laying of 25 cm thicklayer ofriver sand to cover ofexisting cablein 30cmx75cm size cable trench with levellingand making symmetric 25 mm thick layer in complete running lengthof trenchas required. |
| 128 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 129 | 25 Amp. 2 Module Motor Starter with on / off Push button |
| 130 | Providing & Fixing offollowing size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 131 | 1/2 Module |
| 132 | Providing & Fixing offollowing size hot dip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 133 | 1-2 Module |
| 134 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be usedand potted driver must be potted & has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <1000mA shown in LM79 report. The luminaireshall be BIS certified and T.C. certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. |
| 135 | OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached |
| 136 | LED Street Light fixture 90 Watt |
| 137 | Providing & Fixing of IP20 LED Surface/ Recessed/ suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity/ transmity,UV stabilized, non yellowish diffuser for uniform light distribution High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency> 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture) . System Lumen efficacy min.100 Im/watt ,THD < 10 % , p.f.~0.95,CRI >80, life time of minimum 50000 BurningHours with, 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000\"K/6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate/ Report fromOEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \"A\" attached. |
| 138 | Suspended Mounting/Surface Mouting\" |
| 139 | 36W LED light fixture 2\"x2\" with acrylic/prismatic front cover. |
| 140 | Providing & fixing of IP20 LED recess/Surface mounted, Round./ SqaureNon-.Dimmable Back lit SMD Mid Power LED Down light with die-cast aluminum housing & Heat Sink for hea t dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency> 85% and in compliance to IECstandards. System Lumen efficacy min. 100 Im/watt, THD < 10 % ,p.f.~0.95, CRI >80, life t ime of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends , CCT 3000\"K / 4000\"K / 5700°K /6000\"K/6S00\"K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.) Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate/ Report from OEM shall be submitted. All as per pre approved by engineer in charge. foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded . |
| 141 | Surface Mounting |
| 142 | LED Downlight 18/20W |
| 143 | Supply , Installation, Testing and Comissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and50 hz ,1 phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB. |
| 144 | NABL accredeated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391(Part-2) 2018 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 145 | Non Invertor Type |
| 146 | 1.5 TR with 3 star rating of BEE (ISEER not less then 3.5 ) |
| 147 | Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect.NABL accredeated/ CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 148 | 4 kVA |
| 149 | Providing & Fixing in position frame made out of M.S. angle (riveted or welded) as per IS: 2062-2011 finished with two coats of red oxide and two coats of enamel paint including cutting, welding, holes etc. of following sizes as required. All drawing as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 150 | 50mm x 50mm x 6mm |
| 151 | Providing & Fixing of recessed/surface mountingtype sheet steel / Plastic enclosure as per PWD specificationfor electrical Works conforming to IEC 61439-3 ofsheet steel ofnot less than 1.2 mm thickfor housing MCB/Isolator with Din rail including , all as per pre approved by Engineer in charge,making connections,with lugs, repairs etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached. |
| 152 | With sheet steel enclosure |
| 153 | Four way |
| 154 | Providing & Fixing of Street light bracket made out from following size of \" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached . |
| 155 | 40 mm Dia. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy