| Sl. No. | Item Description |
| 1 | Schedule \"A\"-Part I (Earth work & Excavation) |
| 2 | Surface dressing n exc 15 cm deep and getting out in any type of soil all as specified and as directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in any type of soil all as specified and as directed. |
| 4 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in Soft and disintegrated rock all as specified and as directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm insoil all as specified and as directed. |
| 6 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soil all as specified and as directed. |
| 7 | Site Clearance all as specified and as directed. |
| 8 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/ disintegrated rock all as specified and as directed. |
| 9 | M&L for Hard core in broken stone or boulders of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surfaces all as specified and as directed |
| 10 | Removal of soil exc500 mtr but n. exc 1.5 Km and depositing where as directed n exc 1.50 m high from starting point all as specified and as directed. |
| 11 | Excavation in trenches not exceeding 1.5 m width andnot exc 1.5m in depthgetting out in hard/dense soil all as specified and as directed. |
| 12 | Excavation in trenches not exceeding 1.5 m width andnot exc 1.5 in depthgetting out soft disintegrated rock all as specified and as directed. |
| 13 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc. 25 cm in rocks all as specified and as directed. |
| 14 | Removing excavated material (soft rock) exc. 50 m n.exc. 100 m and deposing where directed at a level n.exc. 1.5 m above starting point all as specified and as directed. |
| 15 | Schedule \"A\"-Part II (B/R Portion) |
| 16 | M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) (Column ) all as specified and as directed. |
| 17 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface ( Floor ) all as specified and as directed. |
| 18 | M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and as directed. |
| 19 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and as directed. |
| 20 | M & L for PCC (1:3:6) type C2, using 40 mm graded stone aggregate as bed concrete for Footing,Plinth Beam, Dwarf Wall & Toe Wall etc complete all as specified and as directed. |
| 21 | M & L for RCC- M-30 (Design Mix) using 20mm graded stone aggregate for Foundation, Including rafts as Mass Concrete/Plinth Beam/Column all as specified and as directed. |
| 22 | Use & Waste Form workfor rough finished surfaces of concrete measured flat for foundation/Plinth beams all as specified and as directed. |
| 23 | M&L forCRS TMT bars 10mm dia & over of Grade Fe 500d including cutting, bending, binding & placing in position with binding wire all as specified and as directed. |
| 24 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for Column all as specified and as directed. |
| 25 | Use & Waste Form workfor rough finished surfaces of concrete measured flat for Column finished fair flat surfaces all as specified and as directed. |
| 26 | M&L for CRS TMT bars 5 dia and over upto and including 10mm dia in stirrups, spacers & binders placing in position with binding wire all as specified and as directed. |
| 27 | M&L for CRS TMT bars 6 mm to 8 mm dia of Grade Fe 500d including cutting, bending, binding & placing in position with binding wire all as specified and as directed. |
| 28 | M&L for pre - cast cement concrete block masonry type C-5,with solid blocks built in cement mortar 1:6 all as specified and as directed. |
| 29 | M&L forprecast cement concrete 1:3:6 type C1, using 20 mm graded stone aggregate as solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in cement mortar 1:4, complete, in walls all as specified and as directed. |
| 30 | M & L for RCC M-30 (Design Mix) using 20mm graded aggregate for Lintel Band/Roof beam all as specified and as directed. |
| 31 | Use & Waste Form workfor rough finished surfaces of concrete measured flat Lintel Band/roof beam all as specified and as directed. |
| 32 | M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate for Chajja all as specified and as directed. |
| 33 | Use & Waste Form workfor rough finished surfaces of concrete measured flat Chajja all as specified and as directed. |
| 34 | M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate for Roof Slab all as specified and as directed. |
| 35 | Use & Waste Form workfor fair finished surfaces of concrete measured flat for Roof Slab all as specified and as directed. |
| 36 | M & L for 8 mm Thick Polymer Modified Ready Mixed Cement Base Plaster with minimum 15% flyash content on Internal Wall all as specified and as directed. |
| 37 | M & L for 3mm thick wall care putty on Ceiling all as specified and as directed. |
| 38 | M & L for 12mm Thick Polymer Modified Ready Mixed Cement Base Plaster with minimum 15% flyash content on External Wall all as specified and as directed. |
| 39 | Supply only Integral waterproofing compound all as specified and as directed. |
| 40 | S & F 125 x 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, all as specified and as directed. |
| 41 | S & F 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and as directed. |
| 42 | S & F Anodized aluminium frame for doors, windows, ventilators, Fixed Glazing with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 43 | S & F 5.50 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane all as specified and as directed. |
| 44 | S & F 4.0 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane all as specified and as directed. |
| 45 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides.M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as directed. |
| 46 | Supply and fixing 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as directed. |
| 47 | S & F For 35mm Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); all as specified and as directed. |
| 48 | S & F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and as directed. |
| 49 | S&F 100mm long Stainless steel Butt hinges and fixed all as specified and as directed. |
| 50 | S&F 200 mm long 10 mm dia aluminium tower bolt all as specified and as directed. |
| 51 | S&F 150 mm long Mild steel pressed handles, oval type, stove enamelled black all as specified and as directed. |
| 52 | S&F 150mm Long, 16mm Dia Aluminum aldrop bolt all as specified and as directed. |
| 53 | M&L for MS work such as Bands, Straps, Hold fast, Clamps, Hooks & similar Fe-410-O or Fe-310-O all as specified and as directed. |
| 54 | M & L for two coats of Oil bound distemper Over One coat of Primer onWall all as specified and as directed. |
| 55 | M & L for two coats of oil bound distemper Over One coat of Primer on Ceiling all as specified and as directed. |
| 56 | M&L for Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) all as specified and as directed. |
| 57 | M&L for two coats of synthetic enamel paint over a coat of Zinc Chromate primer over prepared steel surface all as specified and as directed. |
| 58 | M&L for two coats of synthetic enamel paintover a coat of white/ pink primer over prepared surface of wood all as specified and as directed. |
| 59 | M & L for 75mm thick sub base Cement concrete type D-2, 1:4:8, using 40mm graded stone aggregate all as specified and as directed. |
| 60 | M&L for screed bed or bedding layer of cement mortar 1:4, 20 mm thick for laying floor finishes all as specified and as directed. |
| 61 | M & Lfor Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. |
| 62 | M & L for bedding layer ofcement mortar 1:3, 20 mm thick for laying floor finishes all as specified and as directed. |
| 63 | M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 64 | M&L for 12mm Backing Coat in cement mortar 1:3 all as specified and as directed. |
| 65 | M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 66 | M & L for Glazed ceramic Coloured tiles in vertical surface 350x 250x 7mm / 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and as directed. |
| 67 | M & L for 75mm thick Plinth Protection PCC (1:3:6) type C1 using 20mm graded stone aggregate (0.6 m wide) all as specified and as directed. |
| 68 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed. |
| 69 | M&L for 10mm screed bed in cement mortar 1:3 all as specified and as directed. |
| 70 | S & F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) all as specified and as directed. |
| 71 | S & F 10 ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets all as specified and as directed. |
| 72 | S & F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern all as specified and as directed. |
| 73 | S & F 110mm PVC (SWR) WC connector bent type all as specified and as directed. |
| 74 | S & F 32 mm dia Bottle trap of PTMT having minimum water seal of 25mm (Minium weight 32 mm - 260 gms) all as specified and as directed. |
| 75 | S & F 32 mm Waste coupling of PTMT (half or full threaded)(Minium weight 32 mm - 45 gms)all as specified and as directed. |
| 76 | S & F Unplasticised PVC pipes of pressure rating 10 kgf/Sqm fixed complete to walls, ceilings or in Floors etc., any type of pipe 32mm dia all as specified and as directed. |
| 77 | S & F Vitreous China wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and Porcelain stopper but including brackets all as specified and as directed. |
| 78 | S & F C.P. Rubber or vulcanite plug (waste) with rings and fitting and fixing all as specified and as directed. |
| 79 | S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup Washers all as specified and as directed. |
| 80 | S & F towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden /plastic cleats(Minimum weight 190gms) all as specified and as directed. |
| 81 | S&F Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) with Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour all as specified and as directed. |
| 82 | S & F Exterior type Wall mixer S.S.body with separate arrangement for Supplying hot & cold water to tap & shower all as specified and as directed. |
| 83 | S & F Soap dish, vitreous China white, approximate size 160x 160x90mm all as specified and as directed. |
| 84 | S&F Rotational moulded polyethylene water storage tank of 1000 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed. |
| 85 | S & F 25 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and as directed. |
| 86 | S & F PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls 110mm all as specified and as directed. |
| 87 | S & F PVC (SWR) pipes double socketed, in any length with rubber ring joints, laid in trenches or in floors 110mm all as specified and as directed. |
| 88 | S & F PVC (SWR) vent cowl 110mm all as specified and as directed. |
| 89 | S & F PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls 75mm all as specified and as directed. |
| 90 | M & L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and as directed. |
| 91 | S & F PVC (SWR) pipes double socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm all as specified and as directed. |
| 92 | S & F PVC (SWR) Rainwater pipes double socketed in any length with rubber ring joints fixed to walls 150mm all as specified and as directed. |
| 93 | S & F PVC (SWR) bends any radius 150mm all as specified and as directed. |
| 94 | S & F PVC (SWR) branch piece 110mm single (single Y) equal or unequal all as specified and as directed. |
| 95 | S & F PVC (SWR) bends any radius 75mm with access door all as specified and as directed. |
| 96 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm all as specified and as directed. |
| 97 | M&L for precast cement concrete,louvres and jallies, 25mm thick (measured solid), including all mould- ings including frame all as specified and as directed. |
| 98 | S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete for Gde FE 410-W (Gde-E-250) quality-A all as specified and as directed. |
| 99 | S & F Framed work such as grills, gratings etc. with ends of bars shouldered and for riveted or forged into spikes, framed guard bars barred iron doors, ladders, frames balusters walk ways, railing, framework of water tanks and similar work all as specified and as directed. |
| 100 | S & Ffor mild steel 1mm thick, plain, black sheet in hearths, covering to door shutters, covering to door chowkats and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, air tight beadings and all fittings etc. all as specified and as directed. |
| 101 | M & L for PCC (1:3:6) type C1, using 20 mm graded stone aggregate as in steel frames for door filling, mud stops,steps small sumps and like items slightly rounded or chamfered on the edges complete all as specified and as directed. |
| 102 | Schedule \"A\"-Part II (Internal Electrification) |
| 103 | M&L for point wiring complete with 1100 volts grade PVC insulated and unsheathed multistranded 1.5 Sqmm FRLS single core copper conductor cable drawn through and including PVC conduit concealed in wall with all accessories, including 1.5 Sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire for one light, fan, socket outlet etc all as specified and as directed. |
| 104 | All as per serial item No 100, here-in-before but one 5 pin switch socket outlet 5 Amps on independent board controlled by one switch all as specified and as directed. |
| 105 | All as per item No 100, here in before, but one 6 pin socket outlet 15 Amps independent/metal plug and socket with cables 4 sqmm size copper PVC insulated cable multistrandedand 4 sqmm cableconductor for earth wire all as specified and as directed. |
| 106 | Supply & Fixing modular socket, 6A-2/3 pin combined, 2 module all as specified and as directed. |
| 107 | Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts all as specified and as directed. |
| 108 | Supply & Fixing modular socket6A/16A-2/3 pin combined, 2 module all as specified and as directed. |
| 109 | Supply & Fixing modular switch 1 way 16A, 1 module all as specified and as directed. |
| 110 | Supply & fixing modular metal flush box 1/2 module all as specified and as directed. |
| 111 | Supply & fixing modular metal flush box 3 module all as specified and as directed. |
| 112 | Supply & fixing modular metal flush box 6 module all as specified and as directed. |
| 113 | Supply & fixing modular white cover plate with frame, 2 module all as specified and as directed. |
| 114 | Supply & fixing modular white cover plate with frame, 3 module all as specified and as directed. |
| 115 | Supply & fixing modular white cover plate with frame, 6 module all as specified and as directed. |
| 116 | Supply & Fixing Modular Fan Regulater electronic step type 120W-2 module all as specified and as directed. |
| 117 | S & F Ceiling Fan 1200 mm sweep air delivery 220cmm all as specified and as directed. |
| 118 | S & F ceiling rose 3 terminal PVC polycarbonate isolating body complete allas specified and directed. |
| 119 | M & L for one point wiring with PVC insulated un-sheathed stranded copper conductor FR-LSH cable confirming to IS : 694 of size 2.5 sqmm single core, including one No 2.5 sqmm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn through and including concealed stove enamelled steel conduit of suitable size including accessories concealed in wall/ceiling/floor/roof of suitable size for one light/exhaust fan point controlled by one flame proof switch all as specified and as directed. |
| 120 | S&F Switch Flameproof WP Rotary type with termination box in LM6,5A single pole 250V all as specified and as directed.Note:- Cost of necessary flameproof flexible metallic hose conduit from junction box to rotary switch deemed to be included in the quoted rates. |
| 121 | Supply and Fixingflame proof2X16/20 watt LED tube light fittingwith IP65 protection complete with all accessories ,internally pre-wired including connecting up with suitable size twin core FRLS copper conductor all as specified and as directed.Note:- Cost of necessary flameproof flexible metallic hose conduit from junction box to FLP LED tube light fitting deemed to be included in the quoted rates. |
| 122 | Supply and fix MCB, single pole, 6-32 Amp, 240 Volts, \"B\" series 10KA all as specified and as directed. |
| 123 | Supply and fix MCB, four pole, 63 Amps, 415 Volts,C curve 10KA all as specified and as directed. |
| 124 | Supply and fix sheet metal enclosure (DB) for MCBs, 4 way, triple pole and neutral,415 Volts, double door with 200 Amps rated bus barscomplete all as specified and as directed. |
| 125 | Supply and fixing25W 4ft long LED batten light fitting with 2.5 KV voltage surge protection ,PF >0.9 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size all as specified and as directed. |
| 126 | S&F 10 watt 2 feet long LED batten light fitting with 2.5 KV voltage surge protection ,PF >0.9 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size all as specified and as directed. |
| 127 | S & F LED Bldg Security Street light 30W ,IP 65 with 10KV surge protection including suitable sizeof GI pipe 1.2 m long bent to required shape, clamps, nut ,bolts andmaking electrical connection to the fitting with Suitable size of service wire all as specified and as directed. |
| 128 | S&F Submain wiring with 6 sqmm 2 Runs of single core multi stranded PVC in related unsheathed cable 1100 Volts with copper conductor drawn in and including 25 mm wide in non metallic rigid conduit with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 6sqmm single core PVC insulated unsheathed copper conductor as continuousearth wire and connecting to main switch board \ Distribution Board and testing on completion complete all as specified and as directed.Note : 2 runs of 6 Sqmm cable, 1 run of 6 Sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable and 1 run of PVC conduit 25mm wide concealed in wall shall be measured as single run. |
| 129 | S&F Submain wiring with 4 sqmm 2 Runs of single core multi stranded PVC in related unsheathed cable 1100 Volts with copper conductor drawn in and including 25 mm wide in non metallic rigid conduit with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 4 sqmm single core PVC insulated unsheathed copper conductor as continuousearth wire and connecting to main switch board \ Distribution Board and testing on completion complete all as specified and as directed.Note : 2 runs of 4 Sqmm cable, 1 run of 4 Sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable and 1 run of PVC conduit 25mm wide concealed in wall shall be measured as single run. |
| 130 | M&L for earthing complete with GI steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including necessary earth work and excavation of in any type of strata, PCC 1:3:6 type C-2 GI tubing 20 mm dia for watering and 15mm dia GI tubing for protection of wire etc all as per electrical plate No.03 of SSR part I including connecting to electrical equipments and testing on completion all as specified and as directed.Note: GI earthing 4mm upto 7.5m height is deemed to included under quoted rate. |
| 131 | S&F Exhaust fan 300mm sweep, AC single phase 240 V with base frame, louvers etc fixed includingopening of wall hole for fixing of exhaust fan by providing necessary nuts, bolts, washers etc all as specified and as directed. |
| 132 | S&F air termination single pointed aluminium rod 12mm dia 300mm long all as specified and as directed. |
| 133 | Supply and fix test point terminal block madeof gun metal 75 mm x 75 mm x 25 mm drilled and screwed including three Nos 8mm dia 25 mm long hexagonal head screwsall as specified and as directed. |
| 134 | M & L for Aluminium Strip 25 X 3mm with saddle and fixing screws and clamps for supporting on GI pipe etc for roof conductors and down conductors above ground all as specified and as directed. |
| 135 | M & L for GI strip 32x6 mm buried in ground as earth continuity conductor for loop earthing all as specified and as directed. |
| 136 | M&L for earthing complete with Copper earth plate electrode 60 cm x60 cm x 3.15 mm thick electrode burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to copper strip 20 x 3mm by means of bolts, nuts, check nuts and washers of GI or steel including necessary earth work and excavation of in any type of strata, PCC 1:3:6 type C-2 GI tubing 20 mm dia for watering and 40 mm dia GI tubing for protection of wire etc all as per electrical plate No.3 of SSR part I including connecting to electrical equipments and testing on completion all as specified and as directed.Note: Copper strip upto 7.5m height is deemed to included under quoted rate. |
| 137 | Schedule \"A\" - Part IV (Road/Path/Hardstanding/Culverts) |
| 138 | M&L for sand cushioning 50 mm thick spread, levelled, compacted to receive interlocking tiles all as specified and as directed. |
| 139 | M&L for Machine pressed pre cast concrete interlocking paver blocks (with grey cement and pigment) any shape and size conforming to IS-15658-2006 of 60 mm thicknes,M-40 grade all as specified and as directed |
| 140 | M&L for precast cement concrete 1:2:4 using 20mm graded stone aggregate , solidblocksof size 400x300x100mm for kerb stone(with plain or interlocking joints as directed) set in cement mortar 1:4 all as specified and as directed. |
| 141 | M&L for plain cement concrete 1:2:4,Type B1 using 20 mm graded stone aggregate as in kerbs including weathering, slightly angles and throating all as specified and as directed. |
| 142 | M & L for 15 mm thick rendering on fair faces of concrete in cement mortar 1:4 including preparing even & smooth the surfaces without using extra cement complete all as specified and directed. |
| 143 | Schedule \"A\" - Part V (External water supply) |
| 144 | Supply and laying of 50mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fitting in trenches complete all as specified and as directed. |
| 145 | Supply and laying of 25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fitting in trenches complete all as specified and as directed. |
| 146 | Supply and Fixing Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in 50mm dia pipe all as specified and as directed. |
| 147 | Supply and Fixing Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in 25mm dia pipe all as specified and as directed. |
| 148 | Supply & Fix Ball valves high pressure of PTMT with epoxy coated Aluminiumrod& high density plastic ball screwed for iron pipe of dia 25mm and fixed all as specified and as directed. |
| 149 | S&F male brass threaded adaptor 25mm size all as specified and as directed. |
| 150 | Schedule \"A\" - Part VI (External Electric Supply)) |
| 151 | Supply and lay cable XLPE insulatedarmored (heavy duty)electric power cables 1100 volts grade withaluminium conductor of size 70 sqmm 3.5 core all as specified and as directed. |
| 152 | Supply and lay High density poly-ethylene pipes ( HDPE) of pressure rating 6kgf/sqcm fixed complete for road crossing of size 40mm bore all as specified and as directed. |
| 153 | M&L for fine river sand in trenches for cable protection complete all as specified and as directed. |
| 154 | Supply and lay PCC cable cover class LV type 1 flat size 250mmx150mmx40mm all as specified and as directed. |
| 155 | Schedule \"A\" - Part VII (Sewage Disposal) |
| 156 | M&L for Plain cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate in foundation filling and mass concrete all as specified and as directed. |
| 157 | M&L for plain cement concrete in benching (surface channels and drains) type B1 1:2:4 using 20 mm graded stone aggregate all as specified and as directed. |
| 158 | M&L for plain cement concrete type B1 1:2:4 using 20 mm graded stone aggregate in coping, including weathering, slightly rounded or chamferred angle and throating all as specified and as directed. |
| 159 | Extra for forming fair finished rain on channel 30 cm inner girth in cement concrete using extra cement including form and mounds mitred/stopped ends all as specified and as directed. |
| 160 | M&L for pre cast cement concrete type B1, 1:2:4 using 20 mm graded stone aggregate in manhole cover slabs set in cement mortar 1:6 including necessary form work all as specified and as directed. |
| 161 | S&F 150 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches all as specified and as directed. |
| 162 | M & L for concrete bed, type C-2, 1:3:6 for drain pipes including packing underand haunching against the sides of pipes after they are laid and tested for 150mm pipes all as specified and as directed. |
| 163 | S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches all as specified and as directed. |
| 164 | S & F Septic tank hume pipe 10 users capacity exc. in soft /disintegrated rock, PCC 1:4:8 foundation , vent shaft , connectionetc including excavation, RFR and disposal ofsurplus spoil complete all as specified and as directed. |
| 165 | Construction of Soakage well 1.80m dia and 3.0m deep ,Excavation in hard soil/ Soft Rock. Foundation with PCC (1:3:6) , brick work in cement mortar (1:4), RCC cover slab including Precast Manhole cover , and filling with brick bats complete all as per CWE (N) Drg NO : AFB/TD/120 Dt: 07/08/99 Sheet NO: ½ & 2/2 |