Paschimanchal Vidyut Vitran Nigam Limited has published Development Of Distribution Infrastructure Work For Loss Reduction At District Sambhal And J.P. Nagar ( Amroha ) In Psvvnl Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Armouredlt Cabling In High Loss Area ( Lt L. Submission Date for this Tender is 22-08-2022. Bolts Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-May-2022 | Corrigendum-1 | Technical Bid | 14-06-2022 |
2 | 01-Jun-2022 | Corrigendum-2 | Technical Bid | 14-06-2022 |
3 | 06-Jun-2022 | dateext | Date | 21-06-2022 |
4 | 16-Jun-2022 | Corrigendum-3 | Technical Bid | 21-06-2022 |
5 | 18-Jun-2022 | Corrigendum-4 | Technical Bid | 21-06-2022 |
6 | 20-Jun-2022 | dateext2 | Date | 06-07-2022 |
7 | 05-Jul-2022 | dateext3 | Date | 26-07-2022 |
8 | 22-Jul-2022 | dateext4 | Date | 22-08-2022 |
Sl. No. | Item Description |
1 | ArmouredLT cabling in high loss area (LT line on 3.5Cx 50 sq.mm armoured cable) |
2 | PCC Pole, 8.5 Mtr. Long |
3 | Bolts and Nuts for Shackle Insulators |
4 | LT Shakle Insulator 100x115 mm |
5 | D-Straps |
6 | LT XLPE armoured 3.5x50 Sq. mm. Cable |
7 | Mid Span Jointing Sleeves (50 sq. mm) |
8 | Insulating Piercing Connector (50-150 sq.mm) |
9 | Insulation mastic tape (2inc X 10 feet). |
10 | supply of Three Phase Deep Drawn Distribution Box with clamps and suitable lock and key arrangment |
11 | supply of Single of Phase Deep Drawn Distribution Box with clamps and suitable lock and key arrangment |
12 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
13 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
14 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
15 | GI Wire 6 SWG |
16 | LT Stay Set (16 x 1800 mm) |
17 | LT Stay Clamp with nut and bolt |
18 | Stay Wire 7/10 SWG |
19 | LT Stay Insulator |
20 | Stone Pad (300x300x75mm) |
21 | LT clamp with nut and bolt for PCC pole |
22 | Angle for vertical Arm L50X50X6(Type-A) |
23 | Angle for vertical Arm L50X50X6(Type-B) |
24 | Top clamp for Vertical arm( Type-A) |
25 | Top clamp for Vertical arm( Type-B) |
26 | Bottom clamp for vertical arm (Type-A) |
27 | Bottom clamp for vertical arm (Type-B) |
28 | Armouredconsumer cabling in high loss area (Service line on single phase 2Cx 6 sq.mm) |
29 | PVC 2C x 6 sq.mm. Armoured Cable for Service Connection |
30 | Polycarbonated box for single phase consumer |
31 | Armouredcomsumer cabling in high loss area (Service line on three phase 4Cx 16 sq.mm) |
32 | PVC 4C x 16 sq.mm. Armoured Cable for Service Connection |
33 | Polycarbonated box for three phase consumer |
34 | Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables(3x50+1x35+1x16) sq.mm. |
35 | PCC Pole, 8.5 Mtr. Long |
36 | Stone Pad (300x300x75mm) |
37 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
38 | GI Wire 6 SWG |
39 | LT Stay Set (16 x 1800 mm) |
40 | LT Stay Clamp with nut and bolt |
41 | Stay Wire 7/10 SWG |
42 | LT Stay Insulator |
43 | Dead End clamps with I-Hook (Insulated) |
44 | Suspension Clamp with I-Hook |
45 | Pole clamps with nut and bolt |
46 | Holding clamp for round pole with nut and bolt |
47 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
48 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
49 | Supply ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
50 | LT ABC of 3x50+1x35+1x16 sq. mm |
51 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
52 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
53 | End cap for LT AB cable |
54 | PG Clamps |
55 | Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables (3x95+1x70+1x16) sq.mm. |
56 | PCC Pole, 8.5 Mtr. Long |
57 | Stone Pad (300x300x75mm) |
58 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
59 | GI Wire 6 SWG |
60 | LT Stay Set (16 x 1800 mm) |
61 | LT Stay Clamp with nut and bolt |
62 | Stay Wire 7/10 SWG |
63 | LT Stay Insulator |
64 | Dead End clamps with I-Hook (Insulated) |
65 | Suspension Clamp with I-Hook |
66 | Pole clamps with nut and bolt |
67 | Holding clamp for round pole with nut and bolt |
68 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
69 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
70 | Supply ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
71 | LT ABC of 3x95+1x70+1x16 sq. mm |
72 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
73 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
74 | End cap for LT AB cable |
75 | PG Clamps |
76 | Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables (3x120+1x95+1x16) sq.mm. |
77 | PCC Pole, 8.5 Mtr. Long |
78 | Stone pad (300x300x75mm) |
79 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
80 | GI Wire 6 SWG |
81 | LT Stay Set (16 x 1800 mm) |
82 | LT Stay Clamp with nut and bolt |
83 | Stay Wire 7/10 SWG |
84 | LT Stay Insulator |
85 | Dead End clamps with I-Hook (Insulated) |
86 | Suspension Clamp with I-Hook |
87 | Pole clamps with nut and bolt |
88 | Holding clamp for round pole with nut and bolt |
89 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
90 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
91 | Supply ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
92 | LT ABC of 3x120+1x95+1x16 sq. mm |
93 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
94 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
95 | End cap for LT AB cable |
96 | PG Clamps |
97 | Feeder bifurcation (11 KV line) |
98 | 11kV New Line on 11 Mtr. ST Pole with ACSR DOG Conductor (Feeder bifurcation 11 KV Line) |
99 | 11 KV Polymer Disc Insulator B&S type 70 KN |
100 | Disc Fitting B&S type 70 KN |
101 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
102 | 11kV SMC Danger Board with clamp, bolts & nuts |
103 | 11kV SMC Number Plate for clamp with N&B |
104 | 11 KV Stay Set (16 x 1800 mm) |
105 | 11 KV Stay Clamp with nut and bolt |
106 | Stay Wire 7/10 SWG |
107 | 11 KV Stay Insulator |
108 | ACSR Dog Conductor |
109 | P.G. Clamp for ACSR Dog/Raccoon |
110 | Armour Rod with Ferrule for ACSR Dog/Panther/Raccoon Helical performed |
111 | 11 Mtr. STP |
112 | 13 Mtr. STP |
113 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
114 | Aluminium Binding Wire - 6 SWG |
115 | Aluminium Jointing Sleeves |
116 | G.I. Barbed Wire |
117 | GI Wire 6 SWG |
118 | GI Wire 8 SWG |
119 | GI Wire 16 SWG |
120 | Eye Bolt |
121 | Turn Buckle |
122 | Red Oxide Paint |
123 | Aluminium Paint |
124 | 11kV "E" Bracket with N&B |
125 | 11kV `F" Bracket with N&B |
126 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
127 | GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer |
128 | GI Top Channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers |
129 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
130 | Cross arm holding Clamp with nuts & bolts |
131 | V-Type Cross arm for 11KV Line, 100x50x6 mm, GI |
132 | Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. |
133 | GI guarding Angle Iron 75x75x6 mm 3010 mm long |
134 | Stone Pad (300x300x75mm) |
135 | 11kV New Line on 8.5 Mtr. PCC Pole with ACSR DOG Conductor |
136 | 11 KV Polymer Disc Insulator B&S type 70 KN |
137 | Disc Fitting B&S type 70 KN |
138 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
139 | 11kV SMC Danger Board with clamp, bolts & nuts |
140 | 11kV SMC Number Plate for clamp with N&B |
141 | 11 KV Stay Set (16 x 1800 mm) |
142 | 11 KV Stay Clamp with nut and bolt |
143 | Stay Wire 7/10 SWG |
144 | 11 KV Stay Insulator |
145 | ACSR Dog Conductor |
146 | P.G. Clamp for ACSR Dog/Raccoon |
147 | Armour Rod with Ferrule for ACSR Dog/Panther/Raccoon Helical performed |
148 | PCC Pole, 8.5 Mtr. Long |
149 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
150 | Aluminium Binding Wire - 6 SWG |
151 | Aluminium Jointing Sleeves |
152 | G.I. Barbed Wire |
153 | GI Wire 6 SWG |
154 | GI Wire 8 SWG |
155 | GI Wire 16 SWG |
156 | Eye Bolt |
157 | Turn Buckle |
158 | 11kV "E" Bracket with N&B |
159 | 11kV `F" Bracket with N&B |
160 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
161 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
162 | Cross arm holding Clamp with nuts & bolts |
163 | V-Type Cross arm for 11KV Line, 100x50x6 mm, GI |
164 | Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. |
165 | GI guarding Angle Iron 75x75x6 mm 3010 mm long |
166 | Stone Pad (300x300x75mm) |
167 | GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer |
168 | 11 KV Railway Crossing |
169 | 11kV 3x185 mm2XLPE Cable |
170 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
171 | HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing) |
172 | Cable Route Marker |
173 | G.I. Pipe 6" dia . |
174 | 11 Mtr. STP |
175 | Stone Pad (300x300x75mm) |
176 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
177 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
178 | 11 KV Polymer Disc Insulator B&S type 70 KN |
179 | Disc Fitting B&S type 70 KN |
180 | P.G. Clamp for ACSR Dog/Raccoon |
181 | 11kV SMC Number Plate for clamp with N&B |
182 | 11kV SMC Danger Board with clamp, bolts & nuts |
183 | G.I. Barbed Wire |
184 | Aluminium Binding Wire - 6 SWG |
185 | Aluminium Paint |
186 | Red Oxide Paint |
187 | 11 KVStay Set (16 x 1800 mm) |
188 | 11 KV Stay Clamp with nut and bolt |
189 | Stay Wire 7/10 SWG |
190 | 11 KV Stay Insulator |
191 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
192 | GI Wire 6 SWG |
193 | NHAI/State Highway Crossing |
194 | 11kV 3x185 mm2XLPE Cable |
195 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
196 | HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing) |
197 | Cable Route Marker |
198 | G.I. Pipe 6" dia . |
199 | 11 Mtr. STP |
200 | Stone Pad (300x300x75mm) |
201 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
202 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
203 | 11 KV Polymer Disc Insulator B&S type 70 KN |
204 | Disc Fitting B&S type 70 KN |
205 | P.G. Clamp for ACSR Dog/Raccoon |
206 | 11kV SMC Number Plate for clamp with N&B |
207 | 11kV SMC Danger Board with clamp, bolts & nuts |
208 | G.I. Barbed Wire |
209 | Aluminium Binding Wire - 6 SWG |
210 | Aluminium Paint |
211 | Red Oxide Paint |
212 | 11 KV Stay Set (16 x 1800 mm) |
213 | 11 KV Stay Clamp with nut and bolt |
214 | Stay Wire 7/10 SWG |
215 | 11 KV Stay Insulator |
216 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
217 | GI Wire 6 SWG |
218 | Augumentation/ Reconductoring of 33 KV overhead line with Dog conductor |
219 | ACSR Dog Conductor |
220 | PCC Pole, 9.0 Mtr. Long |
221 | 11 Mtr. STP |
222 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
223 | GI Wire 6 SWG |
224 | 33 KV Composite Polymer Pin Insulator with Nut and washers |
225 | Aluminium Paint |
226 | Red Oxide Paint |
227 | 33kV SMC Danger board with clamp and N&B |
228 | 33kV SMC Number plate with clampand N&B |
229 | Stone Pad (300x300x75mm) |
230 | G.I. Barbed Wire |
231 | 33kV "E" Bracket with N&B |
232 | 33kV "F" Bracket with N&B |
233 | V-Type Cross Arm for 33KV line 100x50x6 mm, GI |
234 | Cross arm holding Clamp with nuts & bolts |
235 | 33 KV Polymer Disc Insulator B&S type 70 KN |
236 | Disc Fitting B&S type 70 KN |
237 | 33 KV Stay Set |
238 | 33 KV Stay Clamp with nut and bolt |
239 | Stay Wire 7/8 SWG |
240 | 33 KV Stay Insulator |
241 | Augmentation/Reconductoring of 11kV overhead Linewith ACSR DOG Conductor |
242 | ACSR Dog Conductor |
243 | 11 KV Polymer Disc Insulator B&S type 70 KN |
244 | Disc Fitting B&S type 70 KN |
245 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
246 | 11kV SMC Danger Board with clamp, bolts & nuts |
247 | 11kV SMC Number Plate for clamp with N&B |
248 | 11 KV Stay Set (16 x 1800 mm) |
249 | 11 KV Stay Clamp with nut and bolt |
250 | Stay Wire 7/10 SWG |
251 | 11 KV Stay Insulator |
252 | P.G. Clamp for ACSR Dog/Raccoon |
253 | Armour Rod with Ferrule for ACSR Dog/Panther/Raccoon Helical performed |
254 | PCC Pole, 8.5 Mtr. Long |
255 | 11 Mtr. STP |
256 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
257 | Aluminium Binding Wire - 6 SWG |
258 | Aluminium Jointing Sleeves |
259 | G.I. Barbed Wire |
260 | GI Wire 6 SWG |
261 | GI Wire 8 SWG |
262 | GI Wire 16 SWG |
263 | Eye Bolt |
264 | Turn Buckle |
265 | Red Oxide Paint |
266 | Aluminium Paint |
267 | 11kV `F" Bracket with N&B |
268 | Cross arm holding Clamp with nuts & bolts |
269 | V-Type Cross arm for 11KV Line, 100x50x6 mm, GI |
270 | Guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. |
271 | Stone Pad (300x300x75mm) |
272 | 11 KV Agriculture feeder segregation & feeder splitting due to overloading |
273 | 11kV New Line on 8.5 Mtr. PCC Pole with ACSR Rabbit Conductor |
274 | ACSR Rabbit Conductor |
275 | 11kV Polymer Disc Insulator T&C type 45 KN |
276 | Disc Fittings T&C type 45 KN |
277 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
278 | 11kV SMC Danger Board with clamp, bolts & nuts |
279 | 11kV SMC Number Plate for clamp with N&B |
280 | 11 KV Stay Set (16 x 1800 mm) |
281 | 11 KV Stay Clamp with nut and bolt |
282 | Stay Wire 7/10 SWG |
283 | 11 KV Stay Insulator |
284 | PG Clamps |
285 | Armour Rod with Ferrule for ACSR Dog/Panther/Raccoon Helical performed |
286 | PCC Pole, 8.5 Mtr. Long |
287 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
288 | Aluminium Binding Wire - 6 SWG |
289 | Aluminium Jointing Sleeves |
290 | G.I. Barbed Wire |
291 | GI Wire 6 SWG |
292 | GI Wire 8 SWG |
293 | GI Wire 16 SWG |
294 | Eye Bolt |
295 | Turn Buckle |
296 | 11kV "E" Bracket with N&B |
297 | 11kV `F" Bracket with N&B |
298 | GI Top Channel 100x50x2240 mm. |
299 | Clamp with nuts & bolts for 1300 mm long GI Channel |
300 | GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer |
301 | GI Top Channel 100x50x6, 1525 mm long |
302 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
303 | Cross arm holding Clamp with nuts & bolts |
304 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
305 | V-Type Cross arm for 11KV Line, 65x65x6 mm, GI Angle |
306 | Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. |
307 | Stone Pad (300x300x75mm) |
308 | New LT Line on ACSR Rabbit Conductor on 8.5 Mtr. PCC Pole |
309 | PCC Pole, 8.5 Mtr. Long |
310 | Stone Pad (300x300x75mm) |
311 | LT clamp with nut and bolt for PCC pole |
312 | LT Shakle Insulator 100x115 mm |
313 | Bolts and Nuts for Shackle Insulators |
314 | ACSR Rabbit Conductor |
315 | Aluminium Jointing Sleeves |
316 | Aluminium Binding Wire - 6 SWG |
317 | Earth wire clamp |
318 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
319 | GI Wire 6 SWG |
320 | LT Stay Set (16 x 1800 mm) |
321 | LT Stay Clamp with nut and bolt |
322 | Stay Wire 7/10 SWG |
323 | LT Stay Insulator |
324 | Construction of new 100 KVA, 11/0.433kV Distribution Transformer S/S |
325 | 11/0.44 kV 100 KVA Transformer (Four Star Rating, Level-II) |
326 | PCC Pole, 8.5 Mtr. Long |
327 | Stone Pad (300x300x75mm) |
328 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
329 | GI Channel 100x50x2028mm (For TPMO,LA and Fuse set) |
330 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
331 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
332 | GI Channel 125x65x6, 1300mm (Tee-off) |
333 | Clamp with nuts & bolts for 1300 mm long GI Channel |
334 | 11kV Polymer Disc Insulator T&C type 45 KN |
335 | Disc Fittings T&C type 45 KN |
336 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
337 | 11kV TPMO complete set |
338 | 11kV DO Fuse Set (3 Phase) |
339 | 11kV Lightening Arrestor |
340 | G.I. Barbed Wire |
341 | 11kV SMC Danger Board with clamp, bolts & nuts |
342 | Deep Drawn Distribution boxas per technical specificationsfor 3 Ph 100 KVA DTR |
343 | LT Stay Set (16 x 1800 mm) |
344 | LT Stay Clamp with nut and bolt |
345 | Stay Wire 7/10 SWG |
346 | LT Stay Insulator |
347 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) |
348 | Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer |
349 | LT PVC Cable3.5x150/70Sq.mm. |
350 | ACSR Weasel Conductor |
351 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
352 | GI Wire 6 SWG |
353 | GI Strip 25x3 mm |
354 | GI Angle 100x50x2028mm (ForDistribution box)) |
355 | Al. Crimping lugs 150 sq.mm. |
356 | Al. Crimping lugs 70 sq.mm. |
357 | Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc. |
358 | Construction of new 63 KVA, 11/0.433kV Distribution Transformer S/S |
359 | 11/0.44 kV 63 KVA Transformer (Four Star Rating, Level-II) |
360 | PCC Pole, 8.5 Mtr. Long |
361 | Stone Pad (300x300x75mm) |
362 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
363 | GI Channel 100x50x2028mm (For TPMO,LA and Fuse set) |
364 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
365 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
366 | GI Channel 125x65x6, 1300mm (Tee-off) |
367 | Clamp with nuts & bolts for 1300 mm long GI Channel |
368 | 11kV Polymer Disc Insulator T&C type 45 KN |
369 | Disc Fittings T&C type 45 KN |
370 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
371 | 11kV TPMO complete set |
372 | 11kV DO Fuse Set (3 Phase) |
373 | 11kV Lightening Arrestor |
374 | G.I. Barbed Wire |
375 | 11kV SMC Danger Board with clamp, bolts & nuts |
376 | Deep Drawn Distribution box as per technical specifications for 3 Ph 63 KVA DTR |
377 | LT Stay Set (16 x 1800 mm) |
378 | LT Stay Clamp with nut and bolt |
379 | Stay Wire 7/10 SWG |
380 | LT Stay Insulator |
381 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) |
382 | Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer |
383 | LT PVC Cable3.5x70/35Sq.mm. |
384 | ACSR Weasel Conductor |
385 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
386 | GI Wire 6 SWG |
387 | GI Strip 25x3 mm |
388 | GI Angle 100x50x2028mm (ForDistribution box)) |
389 | Al. Crimping lugs 70 sq.mm. |
390 | Al. Crimping lugs 35 sq.mm. |
391 | Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc. |
392 | Construction of new 25 KVA, 11/0.433kV Distribution Transformer S/S |
393 | 11/0.44 kV 25 KVA Transformer (Four Star Rating, Level-II) |
394 | PCC Pole, 8.5 Mtr. Long |
395 | Stone Pad (300x300x75mm) |
396 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
397 | GI Channel 100x50x2028mm (For TPMO,LA and Fuse set) |
398 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
399 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
400 | GI Channel 125x65x6, 1300mm (Tee-off) |
401 | Clamp with nuts & bolts for 1300 mm long GI Channel |
402 | 11kV Polymer Disc Insulator T&C type 45 KN |
403 | Disc Fittings T&C type 45 KN |
404 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
405 | 11kV TPMO complete set |
406 | 11kV DO Fuse Set (3 Phase) |
407 | 11kV Lightening Arrestor |
408 | G.I. Barbed Wire |
409 | 11kV SMC Danger Board with clamp, bolts & nuts |
410 | Deep Drawn Distribution boxas per technical specifications for 3 Ph 25 KVA DTR |
411 | LT Stay Set (16 x 1800 mm) |
412 | LT Stay Clamp with nut and bolt |
413 | Stay Wire 7/10 SWG |
414 | LT Stay Insulator |
415 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) |
416 | Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer |
417 | LT XLPE insulated unarmoured 4x25 Sq. mm.Cable |
418 | ACSR Weasel Conductor |
419 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
420 | GI Wire 6 SWG |
421 | GI Strip 25x3 mm |
422 | GI Angle 100x50x2028mm (ForDistribution box)) |
423 | Al. Crimping lugs 25 sq.mm. |
424 | Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc. |
425 | Installation of 11 KV Outgoing VCB for Feeder Segreration |
426 | 11KV Outgoing CTR 400/200/5A 350 MVA |
427 | Rearrangement for connecting New 11 KV Switchgear with existing 11 KV Switchgears (Adopter Panel) |
428 | 11kV 3x185 mm2XLPE Cable |
429 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
430 | Heat Shrinkable indoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
431 | 11 Mtr. STP |
432 | GI Top Channel 100x50x2240 mm. |
433 | Stone Pad (300x300x75mm) |
434 | 11 KV Polymer Disc Insulator B&S type 70 KN |
435 | Disc Fitting B&S type 70 KN |
436 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
437 | P.G. Clamp for ACSR Dog/Raccoon |
438 | 11kV "E" Bracket with N&B |
439 | 11kV SMC Number Plate for clamp with N&B |
440 | 11kV SMC Danger Board with clamp, bolts & nuts |
441 | GI Channel 125x65x2028 mm long (Dropper for fuse set) |
442 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
443 | 11kV TPMO complete set |
444 | 11kV DO Fuse Set (3 Phase) |
445 | 11kV Lightening Arrestor |
446 | G.I. Barbed Wire |
447 | Aluminium Binding Wire - 6 SWG |
448 | Aluminium Paint |
449 | Red Oxide Paint |
450 | 11 KV Stay Set (16 x 1800 mm) |
451 | 11 KV Stay Clamp with nut and bolt |
452 | Stay Wire 7/10 SWG |
453 | 11 KV Stay Insulator |
454 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
455 | GI Strip 50x6 mm |
456 | GI Wire 6 SWG |
457 | G.I. Pipe 6" dia . |
458 | 11 KV Railway Crossing |
459 | 11kV 3x185 mm2XLPE Cable |
460 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
461 | HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing) |
462 | Cable Route Marker |
463 | G.I. Pipe 6" dia . |
464 | 11 Mtr. STP |
465 | Stone Pad (300x300x75mm) |
466 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
467 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
468 | 11 KV Polymer Disc Insulator B&S type 70 KN |
469 | Disc Fitting B&S type 70 KN |
470 | P.G. Clamp for ACSR Dog/Raccoon |
471 | 11kV SMC Number Plate for clamp with N&B |
472 | 11kV SMC Danger Board with clamp, bolts & nuts |
473 | G.I. Barbed Wire |
474 | Aluminium Binding Wire - 6 SWG |
475 | Aluminium Paint |
476 | Red Oxide Paint |
477 | 11 KVStay Set (16 x 1800 mm) |
478 | 11 KV Stay Clamp with nut and bolt |
479 | Stay Wire 7/10 SWG |
480 | 11 KV Stay Insulator |
481 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
482 | GI Wire 6 SWG |
483 | NHAI/State Highway Crossing |
484 | 11kV 3x185 mm2XLPE Cable |
485 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
486 | HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing) |
487 | Cable Route Marker |
488 | G.I. Pipe 6" dia . |
489 | 11 Mtr. STP |
490 | Stone Pad (300x300x75mm) |
491 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
492 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
493 | 11 KV Polymer Disc Insulator B&S type 70 KN |
494 | Disc Fitting B&S type 70 KN |
495 | P.G. Clamp for ACSR Dog/Raccoon |
496 | 11kV SMC Number Plate for clamp with N&B |
497 | 11kV SMC Danger Board with clamp, bolts & nuts |
498 | G.I. Barbed Wire |
499 | Aluminium Binding Wire - 6 SWG |
500 | Aluminium Paint |
501 | Red Oxide Paint |
502 | 11 KV Stay Set (16 x 1800 mm) |
503 | 11 KV Stay Clamp with nut and bolt |
504 | Stay Wire 7/10 SWG |
505 | 11 KV Stay Insulator |
506 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
507 | GI Wire 6 SWG |
508 | Requirement of Extra AB Cable for New additional Ckt at DTs |
509 | Construction ofNew LT Line on (3x50 + 1x35 +1x16)sq. mm LT ABC Cable |
510 | PCC Pole, 8.5 Mtr. Long |
511 | 11 Mtr. STP |
512 | Stone Pad (300x300x75mm) |
513 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
514 | GI Wire 6 SWG |
515 | LT Stay Set (16 x 1800 mm) |
516 | LT Stay Clamp with nut and bolt |
517 | Stay Wire 7/10 SWG |
518 | LT Stay Insulator |
519 | Dead End clamps with I-Hook (Insulated) |
520 | Suspension Clamp with I-Hook |
521 | Pole clamps with nut and bolt |
522 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
523 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
524 | Supply ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
525 | LT ABC of 3x50+1x35+1x16 sq. mm |
526 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
527 | End cap for LT AB cable |
528 | PG Clamps |
529 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
530 | Construction of New LT line on (3x95 + 1x70 +1x16)sq. mm LT ABC Cable |
531 | PCC Pole, 8.5 Mtr. Long |
532 | 11 Mtr. STP |
533 | Stone Pad (300x300x75mm) |
534 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
535 | GI Wire 6 SWG |
536 | LT Stay Set (16 x 1800 mm) |
537 | LT Stay Clamp with nut and bolt |
538 | Stay Wire 7/10 SWG |
539 | LT Stay Insulator |
540 | Dead End clamps with I-Hook (Insulated) |
541 | Suspension Clamp with I-Hook |
542 | Pole clamps with nut and bolt |
543 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
544 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
545 | Supply ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
546 | LT ABC of 3x95+1x70+1x16 sq. mm |
547 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
548 | End cap for LT AB cable |
549 | PG Clamps |
550 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
551 | Construction of New LT line on (3x120 + 1x95 +1x16)sq. mm LT ABC Cable |
552 | PCC Pole, 8.5 Mtr. Long |
553 | 11 Mtr. STP |
554 | Stone Pad (300x300x75mm) |
555 | Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
556 | GI Wire 6 SWG |
557 | LT Stay Set (16 x 1800 mm) |
558 | LT Stay Clamp with nut and bolt |
559 | Stay Wire 7/10 SWG |
560 | LT Stay Insulator |
561 | Dead End clamps with I-Hook (Insulated) |
562 | Suspension Clamp with I-Hook |
563 | Pole clamps with nut and bolt |
564 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
565 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
566 | Supply ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
567 | LT ABC of 3x120+1x95+1x16 sq. mm |
568 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
569 | End cap for LT AB cable |
570 | PG Clamps |
571 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
572 | Additional items that may be required for completion of work |
573 | 3x120 sq. mm 11 kV AB Cable |
574 | 11kV Polymer Disc Insulator with Fitting for 11 KVABC |
575 | 11kV Polymer Disc Insulators with I-Hook |
576 | GI Channel 100 x 50 x 3200 mmunit with mounting clamps, Nut, Bolt and washers |
577 | GI Angle 50 x 50 x 6 mm, 3200 mm long with 2 Nos.clamps,required Nut, Bolt and washers |
578 | GI angle65x65x6mm, 450 mm bracing set complete with clamps, Nut, bolt and washers |
579 | 33kV 3x300 mm2XLPE Cable |
580 | LT XLPE insulated unarmoured 1x50 Sq. mm. Cable |
581 | Heat Shrinkable outdoor type termination kit suitable for 33kV XLPE 3x300 Sq. mm. cable size |
582 | Heat Shrinkable 1 ph. termination kit outdoor for 11 kV 3x120 Sq. mm. AB Cable |
583 | Loop Guard complete, 3-Phase |
584 | Spacers LT PVC |
585 | Mid Span Jointing Sleeves (95 sq. mm) |
586 | LT Insulation Piercing Connectors of 95/50 sq. mm - 70/35 sq. mm (For messenger wire jumpering & energizing DB neutral) |
587 | Supply of On/Off switch for street light connections |
588 | Height raising channel 100X50,2240 mm long |
589 | Back clamp for height raising channel holding clamps with bolts & nuts |
590 | Cable jointing kit straight through(3X185 sqmm) |
591 | Cable jointing kit straight through(3X300sqmm) |
592 | Extra prefabricated GI items Like clamp,channel, angle with nut & Bolt |
593 | ArmouredLT cabling in high loss area (LT line on 3.5Cx 50 sq.mm armoured cable) |
594 | Erection of PCC Pole, 8.5 Mtr. Long |
595 | Fixing of Bolts and Nuts for Shackle Insulators |
596 | Fixing of LT Shakle Insulator 100x115 mm |
597 | Fixing of D-Straps |
598 | Stringing of LT XLPE armoured 3.5x50 Sq. mm. Cable |
599 | Fixing of Mid Span Jointing Sleeves (120 sq. mm) |
600 | Fixing of Insulating Piercing Connector (50-150 sq.mm) |
601 | Fixing of Insulation mastic tape (2inc X 10 feet). |
602 | Fixing of Three Phase Deep Drawn Distribution Box with clamps and suitable lock and key arrangment |
603 | Fixing of Single Phase Deep Drawn Distribution Box with clamps and suitable lock and key arrangment |
604 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
605 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
606 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
607 | GI Wire 6 SWG |
608 | Erection of LT Stay Set (16 x 1800 mm) |
609 | Fixing of LT Stay Clamp with nut and bolt |
610 | Erection of Stay Wire 7/10 SWG |
611 | Fixing of LT Stay Insulator |
612 | Concreting of stay set (16x 1800 mm) |
613 | Stone Pad (300x300x75mm) |
614 | Fixing of LT clamp with nut and bolt for PCC pole |
615 | Dismantling of existing overhead line and transportation of materials to nearest PVVNL Store. |
616 | Concreting of Pole/Support (0.268 cu.M.) |
617 | Fixing of Angle for vertical Arm L50X50X6(Type-A) |
618 | Fixing of Angle for vertical Arm L50X50X6(Type-B) |
619 | Fixing of Top clamp for Vertical arm( Type-A) |
620 | Fixing of Top clamp for Vertical arm( Type-B) |
621 | Fixing of Bottom clamp for vertical arm (Type-A) |
622 | Fixing of Bottom clamp for vertical arm (Type-B) |
623 | Armouredconsumer cabling in high loss area (Service line on single phase 2Cx 6 sq.mm) |
624 | Stringing of PVC 2C x 6 sq.mm. Armoured Cable for Service Connection |
625 | Dismanting of old line service cable and connection of new armoured cable |
626 | Fixing of Polycarbonated box for single phase consumer |
627 | Armouredcomsumer cabling in high loss area (Service line on three phase 4Cx 16 sq.mm) |
628 | Stringing of PVC 4C x 16 sq.mm. Armoured Cable for Service Connection |
629 | Dismanting of old line service cable and connection of new armoured cable |
630 | Fixing of Polycarbonated box for three phase consumer |
631 | Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables(3x50+1x35+1x16) sq.mm. |
632 | Erection of PCC Pole, 8.5 Mtr. Long |
633 | Stone Pad (300x300x75mm) |
634 | Concreting of Pole/Support (0.268 cu.M.) |
635 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
636 | GI Wire 6 SWG |
637 | Erection of LT Stay Set (16 x 1800 mm) |
638 | Fixing of LT Stay Clamp with nut and bolt |
639 | Erection of Stay Wire 7/10 SWG |
640 | Fixing of LT Stay Insulator |
641 | Concreting of stay set (16x 1800 mm) |
642 | Fixing of Dead End clamps with I-Hook (Insulated) |
643 | Fixing of Suspension Clamp with I-Hook |
644 | Fixing of Pole clamps with nut and bolt |
645 | Fixing of Holding clamp for round pole with nut and bolt |
646 | Fixing of LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
647 | Fixing of LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
648 | Fixing ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
649 | Stringing of LT ABC of 3x50+1x35+1x16 sq. mm |
650 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
651 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
652 | Dismantling of existing overhead line and transportation of materials to nearest PVVNL Store. |
653 | Fixing of End cap for LT AB cable |
654 | Fixing of PG Clamps |
655 | Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables (3x95+1x70+1x16) sq.mm. |
656 | Erection of PCC Pole, 8.5 Mtr. Long |
657 | Stone Pad (300x300x75mm) |
658 | Concreting of Pole/Support (0.268 cu.M.) |
659 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
660 | GI Wire 6 SWG |
661 | Erection of LT Stay Set (16 x 1800 mm) |
662 | Fixing of LT Stay Clamp with nut and bolt |
663 | Erection of Stay Wire 7/10 SWG |
664 | Fixing of LT Stay Insulator |
665 | Concreting of stay set (16x 1800 mm) |
666 | Dead End clamps with I-Hook (Insulated) |
667 | Fixing of Suspension Clamp with I-Hook |
668 | Fixing of Pole clamps with nut and bolt |
669 | Holding clamp for round pole with nut and bolt |
670 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
671 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
672 | Fixing ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
673 | Stringing of LT ABC of 3x95+1x70+1x16 sq. mm |
674 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
675 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
676 | End cap for LT AB cable |
677 | Fixing of PG Clamps |
678 | Dismantling of existing overhead line and transportation of materials to nearest PVVNL Store. |
679 | Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables (3x120+1x95+1x16) sq.mm. |
680 | Erection of PCC Pole, 8.5 Mtr. Long |
681 | Stone pad (300x300x75mm) |
682 | Concreting of Pole/Support (0.268 Cu.M.) |
683 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
684 | GI Wire 6 SWG |
685 | Erection of LT Stay Set (16 x 1800 mm) |
686 | Fixing of LT Stay Clamp with nut and bolt |
687 | Erection of Stay Wire 7/10 SWG |
688 | Fixing of LT Stay Insulator |
689 | Concreting of Stay set (16x 1800 mm) |
690 | Dead End clamps with I-Hook (Insulated) |
691 | Fixing of Suspension Clamp with I-Hook |
692 | Fixing of Pole clamps with nut and bolt |
693 | Holding clamp for round pole with nut and bolt |
694 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
695 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
696 | Fixing ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
697 | Stringing of LT ABC of 3x120+1x95+1x16 sq. mm |
698 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
699 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
700 | End cap for LT AB cable |
701 | Fixing of PG Clamps |
702 | Dismantling of existing overhead line and transportation of materials to nearest PVVNL Store. |
703 | Feeder bifurcation (11 KV line) |
704 | 11kV New Line on 11 Mtr. ST Pole with ACSR DOG Conductor |
705 | Erection of 11 KV Polymer Disc Insulator B&S type 70 KN |
706 | Erection of Disc Fitting B&S type 70 KN |
707 | Erection of 11 KV Composite Polymer Pin Insulator with Nut and washers |
708 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
709 | Fixing of 11kV SMC Number Plate for clamp with N&B |
710 | Erection of 11 KV Stay Set (16 x 1800 mm) |
711 | Fixing of 11 KV Stay Clamp with nut and bolt |
712 | Erection of Stay Wire 7/10 SWG |
713 | Fixing of 11 KV Stay Insulator |
714 | Concreting of Stay set (16x 1800 mm) |
715 | Stringing of ACSR Dog Conductor |
716 | Fixing of P.G. Clamp for ACSR Dog/Raccoon |
717 | Armour Rod with Ferrule for ACSR Dog/Panther/Raccoon Helical performed |
718 | Erection of 11 Mtr. STP |
719 | Erection of 13 Mtr. STP |
720 | Concreting of Pole/Support (0.44 cu.M.) |
721 | Concreting of Pole (0.64 Cu.M.) |
722 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
723 | Aluminium Binding Wire - 6 SWG |
724 | Aluminium Jointing Sleeves |
725 | G.I. Barbed Wire |
726 | GI Wire 6 SWG |
727 | GI Wire 8 SWG |
728 | GI Wire 16 SWG |
729 | Eye Bolt |
730 | Turn Buckle |
731 | Painting of ST Pole with Red Oxide Paint |
732 | Painting of ST Pole with Aluminium Paint |
733 | Erection of 11kV "E" Bracket with N&B |
734 | Erection of 11kV `F" Bracket with N&B |
735 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
736 | GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer |
737 | GI Top Channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers |
738 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
739 | Cross arm holding Clamp with nuts & bolts |
740 | Erection of V-Type Cross arm for 11KV Line, 100x50x6 mm, GI |
741 | Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. |
742 | GI guarding Angle Iron 75x75x6 mm 3010 mm long |
743 | Tree cutting Compensation |
744 | Stone Pad (300x300x75mm) |
745 | 11kV New Line on 8.5 Mtr. PCC Pole with ACSR DOG Conductor |
746 | Erection of 11 KV Polymer Disc Insulator B&S type 70 KN |
747 | Erection of Disc Fitting B&S type 70 KN |
748 | Erection of 11 KV Composite Polymer Pin Insulator with Nut and washers |
749 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
750 | Fixing of 11kV SMC Number Plate for clamp with N&B |
751 | Erection of 11 KV Stay Set (16 x 1800 mm) |
752 | Fixing of 11 KV Stay Clamp with nut and bolt |
753 | Erection of Stay Wire 7/10 SWG |
754 | Fixing of 11 KV Stay Insulator |
755 | Concreting of Stay set (16x 1800 mm) |
756 | Stringing of ACSR Dog Conductor |
757 | Fixing of P.G. Clamp for ACSR Dog/Raccoon |
758 | Armour Rod with Ferrule for ACSR Dog/Panther/Raccoon Helical performed |
759 | Erection of PCC Pole, 8.5 Mtr. Long |
760 | Concreting of Pole/Support (0.268 Cu.M.) |
761 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
762 | Aluminium Binding Wire - 6 SWG |
763 | Aluminium Jointing Sleeves |
764 | G.I. Barbed Wire |
765 | GI Wire 6 SWG |
766 | GI Wire 8 SWG |
767 | GI Wire 16 SWG |
768 | Eye Bolt |
769 | Turn Buckle |
770 | Erection of 11kV "E" Bracket with N&B |
771 | Erection of 11kV `F" Bracket with N&B |
772 | GI Top Channel 125x65mm, 3200 mm with clamp, bolts, nuts and washers |
773 | GI Angle 65x65x6mm, 4300 mm long bracing with 4 clamps,bolts, nuts and washers |
774 | Cross arm holding Clamp with nuts & bolts |
775 | Erection of V-Type Cross arm for 11KV Line, 100x50x6 mm, GI |
776 | Guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. |
777 | GI guarding Angle Iron 75x75x6 mm 3010 mm long |
778 | Tree cutting Compensation |
779 | Stone Pad (300x300x75mm) |
780 | GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer |
781 | 11 KV Railway Crossing |
782 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
783 | HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing) |
784 | Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 KV & 11 KV XLPE cables |
785 | Laying of 3x185 sq. mm. 11 KV XLPE Insulated Cable underground in HDPE Pipe/ trenches/Riser |
786 | Cable Route Marker |
787 | G.I. Pipe 6" dia . |
788 | Erection of 11 Mtr. STP |
789 | Stone Pad (300x300x75mm) |
790 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
791 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
792 | Erection of 11 KV Polymer Disc Insulator B&S type 70 KN |
793 | Erection of Disc Fitting B&S type 70 KN |
794 | Fixing of P.G. Clamp for ACSR Dog/Raccoon |
795 | Fixing of 11kV SMC Number Plate for clamp with N&B |
796 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
797 | G.I. Barbed Wire |
798 | Aluminium Binding Wire - 6 SWG |
799 | Painting of ST Pole with Aluminium Paint |
800 | Painting of ST Pole with Red Oxide Paint |
801 | Erection of 11 KVStay Set (16 x 1800 mm) |
802 | Fixing of 11 KV Stay Clamp with nut and bolt |
803 | Erection of Stay Wire 7/10 SWG |
804 | Fixing of 11 KV Stay Insulator |
805 | Concreting of Stay set (16x 1800 mm) |
806 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
807 | GI Wire 6 SWG |
808 | Concreting of Pole/Support (0.44 cu.M.) |
809 | Railway Crossing Documentation, Land and Approval Fee etc. |
810 | NHAI/State Highway Crossing |
811 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
812 | HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing) |
813 | Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 KV & 11 KV XLPE cables |
814 | Laying of 3x185 sq. mm. 11 KV XLPE Insulated Cable underground in HDPE Pipe/ trenches/Riser |
815 | Cable Route Marker |
816 | G.I. Pipe 6" dia . |
817 | Erection of 11 Mtr. STP |
818 | Stone Pad (300x300x75mm) |
819 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
820 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
821 | Erection of 11 KV Polymer Disc Insulator B&S type 70 KN |
822 | Disc Fitting B&S type 70 KN |
823 | Fixing of P.G. Clamp for ACSR Dog/Raccoon |
824 | Fixing of 11kV SMC Number Plate for clamp with N&B |
825 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
826 | G.I. Barbed Wire |
827 | Aluminium Binding Wire - 6 SWG |
828 | Painting of ST Pole with Aluminium Paint |
829 | Painting of ST Pole with Red Oxide Paint |
830 | Erection of 11 KV Stay Set (16 x 1800 mm) |
831 | Fixing of 11 KV Stay Clamp with nut and bolt |
832 | Erection of Stay Wire 7/10 SWG |
833 | Fixing of 11 KV Stay Insulator |
834 | Concreting of Stay set (16x 1800 mm) |
835 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
836 | GI Wire 6 SWG |
837 | Concreting of Pole/Support (0.44 cu.M.) |
838 | NHAI/State highway crossing documentation, land charges and approval fee etc. |
839 | Road Restoration charges |
840 | Augumentation/ Reconductoring of 33 KV overhead line with Dog conductor |
841 | Stringing of ACSR Dog Conductor |
842 | Erection of PCC Pole, 9.0 Mtr. Long |
843 | Erection of 11 Mtr. STP |
844 | Concreting of Pole/Support (0.286 cu.M.) |
845 | Concreting of Pole/Support (0.44 cu.M.) |
846 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
847 | GI Wire 6 SWG |
848 | Erection of 33 KV Composite Polymer Pin Insulator with Nut and washers |
849 | Painting of ST Pole with Aluminium Paint |
850 | Painting of ST Pole with Red Oxide Paint |
851 | Fixing of 33kV SMC Danger board with clamp and N&B |
852 | Fixing of 33kV SMC Number plate with clampand N&B |
853 | Stone Pad (300x300x75mm) |
854 | G.I. Barbed Wire |
855 | Erection of 33kV "E" Bracket with N&B |
856 | Erection of 33kV "F" Bracket with N&B |
857 | Erection of V-Type Cross Arm for 33KV line 100x50x6 mm, GI |
858 | Cross arm holding Clamp with nuts & bolts |
859 | Erection of 33 KV Polymer Disc Insulator B&S type 70 KN |
860 | Disc Fitting B&S type 70 KN |
861 | Erection of 33 KV Stay Set |
862 | Fixing of 33 KV Stay Clamp with nut and bolt |
863 | Erection of Stay Wire 7/8 SWG |
864 | Fixing of 33 KV Stay Insulator |
865 | Concreting of 33 KV Stay set |
866 | Dismantling of existing overhead line and transportation of materials to nearest PVVNL Store. |
867 | Augmentation/Reconductoring of 11kV overhead Linewith ACSR DOG Conductor |
868 | Stringing of ACSR Dog Conductor |
869 | Erection of 11 KV Polymer Disc Insulator B&S type 70 KN |
870 | Disc Fitting B&S type 70 KN |
871 | Erection of 11 KV Composite Polymer Pin Insulator with Nut and washers |
872 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
873 | Fixing of 11kV SMC Number Plate for clamp with N&B |
874 | Erection of 11 KV Stay Set (16 x 1800 mm) |
875 | Fixing of 11 KV Stay Clamp with nut and bolt |
876 | Erection of Stay Wire 7/10 SWG |
877 | Fixing of 11 KV Stay Insulator |
878 | Concreting of Stay set (16x 1800 mm) |
879 | Fixing of P.G. Clamp for ACSR Dog/Raccoon |
880 | Armour Rod with Ferrule for ACSR Dog/Panther/Raccoon Helical performed |
881 | Erection of PCC Pole, 8.5 Mtr. Long |
882 | Erection of 11 Mtr. STP |
883 | Concreting of Pole/Support (0.268 cu.M.) |
884 | Concreting of Pole/Support (0.44 cu.M.) |
885 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
886 | Aluminium Binding Wire - 6 SWG |
887 | Aluminium Jointing Sleeves |
888 | G.I. Barbed Wire |
889 | GI Wire 6 SWG |
890 | GI Wire 8 SWG |
891 | GI Wire 16 SWG |
892 | Eye Bolt |
893 | Turn Buckle |
894 | Painting of ST Pole with Red Oxide Paint |
895 | Painting of ST Pole with Aluminium Paint |
896 | Erection of 11kV `F" Bracket with N&B |
897 | Cross arm holding Clamp with nuts & bolts |
898 | Erection of V-Type Cross arm for 11KV Line, 100x50x6 mm, GI |
899 | Guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. |
900 | Stone Pad (300x300x75mm) |
901 | Dismantling of existing overhead line and transportation of materials to nearest PVVNL Store. |
902 | 11 KV Agriculture feeder segregation & feeder splitting due to overloading |
903 | 11kV New Line on 8.5 Mtr. PCC Pole with ACSR Rabbit Conductor |
904 | Stringing of ACSR Rabbit Conductor |
905 | Erection of 11kV Polymer Disc Insulator T&C type 45 KN |
906 | Disc Fittings T&C type 45 KN |
907 | Erection of 11 KV Composite Polymer Pin Insulator with Nut and washers |
908 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
909 | Fixing of 11kV SMC Number Plate for clamp with N&B |
910 | Erection of 11 KV Stay Set (16 x 1800 mm) |
911 | Fixing of 11 KV Stay Clamp with nut and bolt |
912 | Erection of Stay Wire 7/10 SWG |
913 | Fixing of 11 KV Stay Insulator |
914 | Concreting of Stay set (16x 1800 mm) |
915 | Fixing of PG Clamps |
916 | Armour Rod with Ferrule for ACSR Dog/Panther/Raccoon Helical performed |
917 | Erection of PCC Pole, 8.5 Mtr. Long |
918 | Concreting of Pole/Support (0.268 cu.M.) |
919 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
920 | Aluminium Binding Wire - 6 SWG |
921 | Aluminium Jointing Sleeves |
922 | G.I. Barbed Wire |
923 | GI Wire 6 SWG |
924 | GI Wire 8 SWG |
925 | GI Wire 16 SWG |
926 | Eye Bolt |
927 | Turn Buckle |
928 | Erection of 11kV "E" Bracket with N&B |
929 | Erection of 11kV `F" Bracket with N&B |
930 | GI Top Channel 100x50x2240 mm. |
931 | Clamp with nuts & bolts for 1300 mm long GI Channel |
932 | GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer |
933 | GI Top Channel 100x50x6, 1525 mm long |
934 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
935 | Cross arm holding Clamp with nuts & bolts |
936 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
937 | Erection of V-Type Cross arm for 11KV Line, 65x65x6 mm, GI Angle |
938 | Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. |
939 | Tree cutting Compensation |
940 | Stone Pad (300x300x75mm) |
941 | New LT Line on ACSR Rabbit Conductor on 8.5 Mtr. PCC Pole |
942 | Erection of PCC Pole, 8.5 Mtr. Long |
943 | Stone Pad (300x300x75mm) |
944 | LT clamp with nut and bolt for PCC pole |
945 | LT Shakle Insulator 100x115 mm |
946 | Bolts and Nuts for Shackle Insulators |
947 | Concreting of Pole/Support (0.268 cu.M.) |
948 | Stringing of ACSR Rabbit Conductor |
949 | Aluminium Jointing Sleeves |
950 | Aluminium Binding Wire - 6 SWG |
951 | Earth wire clamp |
952 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
953 | GI Wire 6 SWG |
954 | Erection of LT Stay Set (16 x 1800 mm) |
955 | Fixing of LT Stay Clamp with nut and bolt |
956 | Erection of Stay Wire 7/10 SWG |
957 | Fixing of LT Stay Insulator |
958 | Concreting of Stay set (16x 1800 mm) |
959 | Construction of new 100 KVA, 11/0.433kV Distribution Transformer S/S |
960 | Installation of 11/0.44 kV 100 KVA Transformer (Four Star Rating, Level-II) |
961 | Erection of PCC Pole, 8.5 Mtr. Long |
962 | Stone Pad (300x300x75mm) |
963 | Concreting of Pole/Support (0.268 cu.M.) |
964 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
965 | GI Channel 100x50x2028mm (For TPMO,LA and Fuse set) |
966 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
967 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
968 | GI Channel 125x65x6, 1300mm (Tee-off) |
969 | Clamp with nuts & bolts for 1300 mm long GI Channel |
970 | Erection of 11kV Polymer Disc Insulator T&C type 45 KN |
971 | Disc Fittings T&C type 45 KN |
972 | Erection of 11 KV Composite Polymer Pin Insulator with Nut and washers |
973 | Erection of 11kV TPMO complete set |
974 | Erection of 11kV DO Fuse Set (3 Phase) |
975 | Erection of 11kV Lightening Arrestor |
976 | G.I. Barbed Wire |
977 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
978 | Fixing of Deep Drawn Distribution boxas per technical specificationsfor 3 Ph 100 KVA DTR |
979 | Erection of LT Stay Set (16 x 1800 mm) |
980 | Fixing of LT Stay Clamp with nut and bolt |
981 | Erection of Stay Wire 7/10 SWG |
982 | Fixing of LT Stay Insulator |
983 | Concreting of Stay set (16x 1800 mm) |
984 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) |
985 | Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer |
986 | LT PVC Cable3.5x150/70Sq.mm. |
987 | ACSR Weasel Conductor |
988 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
989 | GI Wire 6 SWG |
990 | GI Strip 25x3 mm |
991 | GI Angle 100x50x2028mm (ForDistribution box)) |
992 | Al. Crimping lugs 150 sq.mm. |
993 | Al. Crimping lugs 70 sq.mm. |
994 | Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc. |
995 | Construction of new 63 KVA, 11/0.433kV Distribution Transformer S/S |
996 | Installation of11/0.44 kV 63 KVA Transformer (Four Star Rating, Level-II) |
997 | Erection of PCC Pole, 8.5 Mtr. Long |
998 | Stone Pad (300x300x75mm) |
999 | Concreting of Pole/Support (0.268 cu.M.) |
1000 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
1001 | GI Channel 100x50x2028mm (For TPMO,LA and Fuse set) |
1002 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
1003 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
1004 | GI Channel 125x65x6, 1300mm (Tee-off) |
1005 | Clamp with nuts & bolts for 1300 mm long GI Channel |
1006 | Erection of 11kV Polymer Disc Insulator T&C type 45 KN |
1007 | Disc Fittings T&C type 45 KN |
1008 | Erection of 11 KV Composite Polymer Pin Insulator with Nut and washers |
1009 | Erection of 11kV TPMO complete set |
1010 | Erection of 11kV DO Fuse Set (3 Phase) |
1011 | Erection of 11kV Lightening Arrestor |
1012 | G.I. Barbed Wire |
1013 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
1014 | Fixing of Deep Drawn Distribution box as per technical specifications for 3 Ph 63 KVA DTR |
1015 | Erection of LT Stay Set (16 x 1800 mm) |
1016 | Fixing of LT Stay Clamp with nut and bolt |
1017 | Erection of Stay Wire 7/10 SWG |
1018 | Fixing of LT Stay Insulator |
1019 | Concreting of Stay set (16x 1800 mm) |
1020 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) |
1021 | Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer |
1022 | LT PVC Cable3.5x70/35Sq.mm. |
1023 | ACSR Weasel Conductor |
1024 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
1025 | GI Wire 6 SWG |
1026 | GI Strip 25x3 mm |
1027 | GI Angle 100x50x2028mm (ForDistribution box)) |
1028 | Al. Crimping lugs 70 sq.mm. |
1029 | Al. Crimping lugs 35 sq.mm. |
1030 | Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc. |
1031 | Construction of new 25 KVA, 11/0.433kV Distribution Transformer S/S |
1032 | Installation of11/0.44 kV 25 KVA Transformer (Four Star Rating, Level-II) |
1033 | Erection of PCC Pole, 8.5 Mtr. Long |
1034 | Stone Pad (300x300x75mm) |
1035 | Concreting of Pole/Support (0.268 cu.M.) |
1036 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
1037 | GI Channel 100x50x2028mm (For TPMO,LA and Fuse set) |
1038 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
1039 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
1040 | GI Channel 125x65x6, 1300mm (Tee-off) |
1041 | Clamp with nuts & bolts for 1300 mm long GI Channel |
1042 | Erection of 11kV Polymer Disc Insulator T&C type 45 KN |
1043 | Disc Fittings T&C type 45 KN |
1044 | Erection of 11 KV Composite Polymer Pin Insulator with Nut and washers |
1045 | Erection of 11kV TPMO complete set |
1046 | Erection of 11kV DO Fuse Set (3 Phase) |
1047 | Erection of 11kV Lightening Arrestor |
1048 | G.I. Barbed Wire |
1049 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
1050 | Fixing of Deep Drawn Distribution boxas per technical specifications for 3 Ph 25 KVA DTR |
1051 | Erection of LT Stay Set (16 x 1800 mm) |
1052 | Fixing of LT Stay Clamp with nut and bolt |
1053 | Erection of Stay Wire 7/10 SWG |
1054 | Fixing of LT Stay Insulator |
1055 | Concreting of Stay set (16x 1800 mm) |
1056 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) |
1057 | Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer |
1058 | LT XLPE insulated unarmoured 4x25 Sq. mm.Cable |
1059 | ACSR Weasel Conductor |
1060 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
1061 | GI Wire 6 SWG |
1062 | GI Strip 25x3 mm |
1063 | GI Angle 100x50x2028mm (ForDistribution box)) |
1064 | Al. Crimping lugs 25 sq.mm. |
1065 | Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc. |
1066 | Installation of 11 KV Outgoing VCB for Feeder Segreration |
1067 | Installation of 11KV Outgoing CTR 400/200/5A 350 MVA |
1068 | Rearrangement for connecting New 11 KV Switchgear with existing 11 KV Switchgears (Adopter Panel) |
1069 | 11kV 3x185 mm2XLPE Cable |
1070 | Laying of 11 KV Cable including cost of Sand & Bricks |
1071 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
1072 | Heat Shrinkable indoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
1073 | Erection of 11 Mtr. STP |
1074 | GI Top Channel 100x50x2240 mm. |
1075 | Stone Pad (300x300x75mm) |
1076 | Erection of 11 KV Polymer Disc Insulator B&S type 70 KN |
1077 | Disc Fitting B&S type 70 KN |
1078 | Erection of 11 KV Composite Polymer Pin Insulator with Nut and washers |
1079 | Fixing of P.G. Clamp for ACSR Dog/Raccoon |
1080 | Erection of 11kV "E" Bracket with N&B |
1081 | Fixing of 11kV SMC Number Plate for clamp with N&B |
1082 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
1083 | GI Channel 125x65x2028 mm long (Dropper for fuse set) |
1084 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
1085 | Erection of 11kV TPMO complete set |
1086 | Erection of 11kV DO Fuse Set (3 Phase) |
1087 | Erection of 11kV Lightening Arrestor |
1088 | G.I. Barbed Wire |
1089 | Aluminium Binding Wire - 6 SWG |
1090 | Painting of ST Pole with Aluminium Paint |
1091 | Painting of ST Pole with Red Oxide Paint |
1092 | Erection of 11 KV Stay Set (16 x 1800 mm) |
1093 | Fixing of 11 KV Stay Clamp with nut and bolt |
1094 | Erection of Stay Wire 7/10 SWG |
1095 | Fixing of 11 KV Stay Insulator |
1096 | Concreting of Stay set (16x 1800 mm) |
1097 | Concreting of Pole/Support (0.44 cu.M.) |
1098 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
1099 | GI Strip 50x6 mm |
1100 | GI Wire 6 SWG |
1101 | G.I. Pipe 6" dia . |
1102 | Control Room Extension |
1103 | Extension of existing substationcontrol room building.( as per annexure attached in tender documents.) |
1104 | 11 KV Railway Crossing |
1105 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
1106 | HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing) |
1107 | Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 KV & 11 KV XLPE cables |
1108 | Laying of 3x185 sq. mm. 11 KV XLPE Insulated Cable underground in HDPE Pipe/ trenches/Riser |
1109 | Cable Route Marker |
1110 | G.I. Pipe 6" dia . |
1111 | Erection of 11 Mtr. STP |
1112 | Stone Pad (300x300x75mm) |
1113 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
1114 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
1115 | Erection of 11 KV Polymer Disc Insulator B&S type 70 KN |
1116 | Disc Fitting B&S type 70 KN |
1117 | Fixing of P.G. Clamp for ACSR Dog/Raccoon |
1118 | Fixing of 11kV SMC Number Plate for clamp with N&B |
1119 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
1120 | G.I. Barbed Wire |
1121 | Aluminium Binding Wire - 6 SWG |
1122 | Painting of ST Pole with Aluminium Paint |
1123 | Painting of ST Pole with Red Oxide Paint |
1124 | Erection of 11 KVStay Set (16 x 1800 mm) |
1125 | Fixing of 11 KV Stay Clamp with nut and bolt |
1126 | Erection of Stay Wire 7/10 SWG |
1127 | Fixing of 11 KV Stay Insulator |
1128 | Concreting of Stay set (16x 1800 mm) |
1129 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
1130 | GI Wire 6 SWG |
1131 | Concreting of Pole/Support (0.44 cu.M.) |
1132 | Railway Crossing Documentation, Land and Approval Fee etc. |
1133 | NHAI/State Highway Crossing |
1134 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
1135 | HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing) |
1136 | Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 KV & 11 KV XLPE cables |
1137 | Laying of 3x185 sq. mm. 11 KV XLPE Insulated Cable underground in HDPE Pipe/ trenches/Riser |
1138 | Cable Route Marker |
1139 | G.I. Pipe 6" dia . |
1140 | Erection of 11 Mtr. STP |
1141 | Stone Pad (300x300x75mm) |
1142 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers |
1143 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
1144 | Erection of 11 KV Polymer Disc Insulator B&S type 70 KN |
1145 | Disc Fitting B&S type 70 KN |
1146 | Fixing of P.G. Clamp for ACSR Dog/Raccoon |
1147 | Fixing of 11kV SMC Number Plate for clamp with N&B |
1148 | Fixing of 11kV SMC Danger Board with clamp, bolts & nuts |
1149 | G.I. Barbed Wire |
1150 | Aluminium Binding Wire - 6 SWG |
1151 | Painting of ST Pole with Aluminium Paint |
1152 | Painting of ST Pole with Red Oxide Paint |
1153 | Erection of 11 KV Stay Set (16 x 1800 mm) |
1154 | Fixing of 11 KV Stay Clamp with nut and bolt |
1155 | Erection of Stay Wire 7/10 SWG |
1156 | Fixing of 11 KV Stay Insulator |
1157 | Concreting of Stay set (16x 1800 mm) |
1158 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
1159 | GI Wire 6 SWG |
1160 | Concreting of Pole/Support (0.44 cu.M.) |
1161 | NHAI/State highway crossing documentation, land charges and approval fee etc. |
1162 | Road Restoration charges |
1163 | Requirement of Extra AB Cable for New additional Ckt at DTs |
1164 | Construction ofNew LT Line on (3x50 + 1x35 +1x16)sq. mm LT ABC Cable |
1165 | Erection of PCC Pole, 8.5 Mtr. Long |
1166 | Erection of 11 Mtr. STP |
1167 | Stone Pad (300x300x75mm) |
1168 | Concreting of Pole/Support (0.268 cu.M.) |
1169 | Concreting of Pole/Support (0.44 cu.M.) |
1170 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
1171 | GI Wire 6 SWG |
1172 | Erection of LT Stay Set (16 x 1800 mm) |
1173 | Fixing of LT Stay Clamp with nut and bolt |
1174 | Erection of Stay Wire 7/10 SWG |
1175 | Fixing of LT Stay Insulator |
1176 | Concreting of stay set (16x 1800 mm) |
1177 | Dead End clamps with I-Hook (Insulated) |
1178 | Fixing of Suspension Clamp with I-Hook |
1179 | Fixing of Pole clamps with nut and bolt |
1180 | LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
1181 | LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
1182 | Fixing ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
1183 | Stringing of LT ABC of 3x50+1x35+1x16 sq. mm |
1184 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
1185 | End cap for LT AB cable |
1186 | Fixing of PG Clamps |
1187 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
1188 | Construction of New LT line on (3x95 + 1x70 +1x16)sq. mm LT ABC Cable |
1189 | Erection of PCC Pole, 8.5 Mtr. Long |
1190 | Erection of 11 Mtr. STP |
1191 | Stone Pad (300x300x75mm) |
1192 | Concreting of Pole/Support (0.268 cu.M.) |
1193 | Concreting of Pole/Support (0.44 cu.M.) |
1194 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
1195 | GI Wire 6 SWG |
1196 | Erection of LT Stay Set (16 x 1800 mm) |
1197 | Fixing of LT Stay Clamp with nut and bolt |
1198 | Erection of Stay Wire 7/10 SWG |
1199 | Fixing of LT Stay Insulator |
1200 | Concreting of stay set (16x 1800 mm) |
1201 | Dead End clamps with I-Hook (Insulated) |
1202 | Fixing of Suspension Clamp with I-Hook |
1203 | Fixing of Pole clamps with nut and bolt |
1204 | Fixing of LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
1205 | Fixing of LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
1206 | Fixing ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
1207 | Stringing of LT ABC of 3x95+1x70+1x16 sq. mm |
1208 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
1209 | End cap for LT AB cable |
1210 | Fixing of PG Clamps |
1211 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
1212 | Construction of New LT line on (3x120 + 1x95 +1x16)sq. mm LT ABC Cable |
1213 | Erection of PCC Pole, 8.5 Mtr. Long |
1214 | Erection of 11 Mtr. STP |
1215 | Stone Pad (300x300x75mm) |
1216 | Concreting of Pole/Support (0.268 cu.M.) |
1217 | Concreting of Pole/Support (0.44 cu.M.) |
1218 | Fixing of Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) |
1219 | GI Wire 6 SWG |
1220 | Erection of LT Stay Set (16 x 1800 mm) |
1221 | Fixing of LT Stay Clamp with nut and bolt |
1222 | Erection of Stay Wire 7/10 SWG |
1223 | Fixing of LT Stay Insulator |
1224 | Concreting of stay set (16x 1800 mm) |
1225 | Dead End clamps with I-Hook (Insulated) |
1226 | Fixing of Suspension Clamp with I-Hook |
1227 | Fixing of Pole clamps with nut and bolt |
1228 | Fixing of LT Insulation Piercing Connectors of 120-50 sq. mm -50-35 sq. mm size for energizing distribution kiosk/box |
1229 | Fixing of LT Insulation Piercing connectors (16 sq. mm -16 sq. mm) suitable for street light connection |
1230 | Fixing ofDeep Drawn LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment |
1231 | Stringing of LT ABC of 3x120+1x95+1x16 sq. mm |
1232 | 1x35 mm2 XLPE insulated AL. cable for energising the distribution boxes/kiosks. |
1233 | End cap for LT AB cable |
1234 | Fixing of PG Clamps |
1235 | 1x16 mm2 XLPE insulated Al. cable for energising the street light |
1236 | Additional items that may be required for completion of work |
1237 | 3x120 sq. mm 11 kV AB Cable |
1238 | 11kV Polymer Disc Insulator with Fitting for 11 KVABC |
1239 | 11kV Polymer Disc Insulators with I-Hook |
1240 | Erection & concreting of Extra Stud Pole complete with clamps, |
1241 | GI Channel 100 x 50 x 3200 mmunit with mounting clamps, Nut, Bolt and washers |
1242 | GI Angle 50 x 50 x 6 mm, 3200 mm long with 2 Nos.clamps,required Nut, Bolt and washers |
1243 | GI angle65x65x6mm, 450 mm bracing set complete with clamps, Nut, bolt and washers |
1244 | LT XLPE insulated unarmoured 1x50 Sq. mm. Cable |
1245 | Heat Shrinkable outdoor type termination kit suitable for 33kV XLPE 3x300 Sq. mm. cable size |
1246 | Heat Shrinkable 1 ph. termination kit outdoor for 11 kV 3x120 Sq. mm. AB Cable |
1247 | Laying of 3x300 sq. mm. 33 KV XLPE Insulated Cable underground in HDPE Pipe or trenches ( For Railway/Road Crossing) |
1248 | Drilling & Laying of HT Underground Cable using HDD method without using HDPE Pipe |
1249 | Loop Guard complete, 3-Phase |
1250 | Spacers LT PVC |
1251 | Mid Span Jointing Sleeves (95 sq. mm) |
1252 | LT Insulation Piercing Connectors of 95/50 sq. mm - 70/35 sq. mm (For messenger wire jumpering & energizing DB neutral) |
1253 | Fixing of On/Off switch for street light connections |
1254 | Mounting of cable on DP structure(including loop and riser) |
1255 | Height raising channel 100X50,2240 mm long |
1256 | Back clamp for height raising channel holding clamps with bolts & nuts |
1257 | Cable jointing kit straight through(3X185 sqmm) |
1258 | Cable jointing kit straight through(3X300sqmm) |
1259 | Extra prefabricated GI items Like clamp,channel, angle with nut & Bolt |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy