Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-05-2022 | Date Extension | Date | 14-06-2022 |
| Sl. No. | Item Description |
| 1 | SUPPLY OF ITEMS |
| 2 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 3 | 9 Meter long STP as per Approved Drawing and Technical specification (SP-33) |
| 4 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
| 5 | 13 Meter long STP as per Approved Drawing and Technical specification (SP-72) |
| 6 | Stone Pad (300x300x75mm) |
| 7 | 1 core (Al.) 120mm2 LT Armoured XLPE Cable |
| 8 | 1 core (Al.) 95mm2 LT Armoured XLPE Cable |
| 9 | 1 core (Al.) 50mm2 LT Armoured XLPE Cable |
| 10 | 1 core (Al.) 25mm2 LT Armoured XLPE Cable |
| 11 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
| 12 | 1x25 mm2 PVC insulated Al. LT Cable for energising the distribution boxes. |
| 13 | 1x25 mm2 Armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
| 14 | Armoured Service Cable 2CX4 SQMM For Single phase consumer |
| 15 | Armoured Service Cable 2CX6 SQMM For Single phase consumer |
| 16 | Armoured Service Cable 4CX10 SQMM For Three phase consumer |
| 17 | Armoured Service Cable 4CX16 SQMM For Three phase consumer |
| 18 | LT ABC 3x120+1x95+1x16 sq.mm. (Bare Massenger Wire) |
| 19 | LT ABC 3x50+1x35+1x16 sq.mm. (Bare Massenger Wire) |
| 20 | LT ABC 3x95+1x70+1x16 sq.mm. (Bare Massenger Wire) |
| 21 | LT PVC cable 3.5x150 Sq mm |
| 22 | LT PVC cable 3.5x70 Sq mm |
| 23 | LT PVC cable 4x16 Sq mm |
| 24 | L.T. PVC cable 10 Sq. mm Single Core |
| 25 | LT PVC cable 3.5x400 Sq mm |
| 26 | ACSR Rabbit Conductor |
| 27 | Aluminium binding wire - 6 SWG |
| 28 | Jointing sleave |
| 29 | Mid Span Joint 120mm2 |
| 30 | ACSR Rabbit Conductor -Jumpering Works |
| 31 | ACSR Weasel Conductor-Jumpering Works |
| 32 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 33 | 11 KV Number Plate with Clamp and Nuts & Bolts |
| 34 | 11KV Fuse Set (Drop out) with clamps |
| 35 | 11KV TPMO with fixing clamps |
| 36 | 10 KVA, 11KV/250 V, 1 Ph Transformer as BEE standard (Self protected). |
| 37 | 16 KVA, 11KV/250 V, 1 Ph Transformer as BEE standard (Self protected). |
| 38 | 25 KVA , 11/0.433 KV T/F (BEE Standard 3 Star Rating Self Protected Aluminium Wound Type) |
| 39 | 63 KVA , 11/0.433 KV T/F (BEE Standard 3 Star Rating Self Protected Aluminium Wound Type) |
| 40 | 100 KVA , 11/0.433 KV T/F (BEE Standard 3 Star Rating Self Protected Aluminium Wound Type) |
| 41 | LT Distribution Box withMCCB for protection of 10 KVA T/F and Bus Bar foroutgoing consumer connections and suitable to house Energy meter (without Energy meter) (Deep drawn Type) as per TS. |
| 42 | LT Distribution Box withMCCB for protection of 16 KVA T/F and Bus Bar foroutgoing consumer connections and suitable to house Energy meter (without Energy meter) (Deep drawn Type) as per TS. |
| 43 | LT incoming Panel with AMI metering (Smart Meter compitable with System) equipment & fixing arrangement (As per TS ). (Deep Drawn Type) for 25KVA |
| 44 | LT incoming Panel with AMI metering (Smart Meter compitable with System) equipment & fixing arrangement (As per TS ). (Deep Drawn Type) for 63 KVA |
| 45 | LT incoming Panel with AMI metering (Smart Meter compitable with System) equipment & fixing arrangement (As per TS ). (Deep Drawn Type) for 100KVA |
| 46 | LT incoming Panel with AMI metering (Smart Meter compitable with System) equipment & fixing arrangement (As per TS). (Deep Drawn Type) for 250KVA |
| 47 | 4 core LT MCB with box |
| 48 | Copper L-Piece 50x225x10mm |
| 49 | Copper L-Piece 50x225x12mm |
| 50 | Al Leg long barrel off size |
| 51 | 9 KV LA , 5 KA (Distribution Class) |
| 52 | 9 KV LA , 10 KA (Station Class) |
| 53 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 54 | GI Flat 50X6 for Earthing |
| 55 | GI Flat 25X3 for Earthing |
| 56 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 57 | GI Pipe 6\" Diameter with clamps |
| 58 | G.I. Barbed Wire |
| 59 | G.I. Wire No. 16 SWG for binding |
| 60 | G.I. Wire 6 SWG |
| 61 | G.I. Wire 8 SWG |
| 62 | 33 KV G.I. Pin (10 KN) with nuts & washers |
| 63 | 11 KV Disc Fitting B & S type (45 KN) |
| 64 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 65 | 11 KV Pin Insulator Polymer Type as per TS |
| 66 | 33 KV Pin Insulator |
| 67 | LT Shackle Insulator |
| 68 | Insulating Piercing Connector (50-150 sq.mm) |
| 69 | Insulating Piercing Connector (16-150 sq.mm) |
| 70 | Dead End clamp (Insulated) |
| 71 | End Cap for AB cable |
| 72 | Suspension clamps (Insulated) |
| 73 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
| 74 | D-Straps |
| 75 | Insulation mastic tape (2inc X 10 feet). |
| 76 | Single Phase Distribution Box with clamps (Deep Drawn Type) - 1 Incoming and 8 outgoing |
| 77 | Three Phase Distribution Box with clamps (Deep Drawn Type) 1 Incoming and 4 outgoing |
| 78 | Aluminium paint |
| 79 | Red Oxide Paint |
| 80 | Smart TVM Meter Compatible with System (AMI) complete Set |
| 81 | HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc |
| 82 | Crimping type heavy duty aluminium lugs suitable for connection PVC cables |
| 83 | Armour rod with ferrules for ACSR Rabbit/Weasel Helical Performed |
| 84 | Cable Route Marker |
| 85 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
| 86 | PG Clamp for Rabbit |
| 87 | GI Stay Wire 7/10 SWG |
| 88 | GI Stay Wire 7/8 SWG |
| 89 | HT Guy Insulator |
| 90 | LT Guy Insulator |
| 91 | 33 KV Stay Complete (GI Stay Rod 20x1800 mm,Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 92 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 93 | Turn Buckle |
| 94 | HT Stay Clamp as per approved drawing-33 KV |
| 95 | HT Stay Clamp as per approved drawing-11 KV |
| 96 | LT Stay Clamp as per approved drawing |
| 97 | 11 KV Cross arm holding clamps with bolts & nuts |
| 98 | 11 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm ) |
| 99 | 33 KV Cross arm holding clamps with bolts & nuts |
| 100 | 33 KV Steel X-arm V type (GI Channel 100 X 50 X 6 mm ) |
| 101 | Angle for vertical ArmL50x50x6 (Type -A)-900MM |
| 102 | Angle for vertical ArmL50x50x6 (Type -B)- 900MM |
| 103 | Top Clamp for Vertical arm L 50X6 (Type -A)- 435 mm |
| 104 | Top Clamp for Vertical arm L 50X6 (Type -B)- 435 mm |
| 105 | Bottom Clamp for Vertical arm L 50X6 (Type -A)- 507 mm |
| 106 | Bottom Clamp for Vertical arm L 50X6 (Type -B)- 507 mm |
| 107 | Clamp FOR Top Channel with Nut bolt |
| 108 | Clamps for LT T-off with bolts & nuts |
| 109 | E- Bracket for 11 KV line |
| 110 | Eye Bolt |
| 111 | F- Bracket for 11 KV line |
| 112 | F- Bracket for 33 KV line |
| 113 | Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp |
| 114 | Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts |
| 115 | M.S. Top channel 100x50x6 mm., 2240 mmlong |
| 116 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
| 117 | GI Channel 100x50x6 mm 2028 mm long (For Fuse Set ) |
| 118 | M.S. Top channel 125x65x6 mm., 2240 mmlong |
| 119 | Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt |
| 120 | Clamps for Dist. Box (40x6 mm) |
| 121 | Clamps for T/F (75x8 mm GI flat). |
| 122 | GI. guarding Angle 75x75x6 mm 3010 mm long with Clamp |
| 123 | Height raising channel 100x50,2240 mm long |
| 124 | Back clamp for Height raising channel holding clamps with bolts & nuts |
| 125 | GI Channel 100x50x6 mm. 1300 mm long |
| 126 | GI Channel clamp with nuts & bolts |
| 127 | GI Angle Iron 50x50x6 mm bracing with 4 clamps |
| 128 | GI Channel 125x65 mm |
| 129 | GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base) |
| 130 | GI Channel 75x75x6 mm &bolt and nut (T/F base Support) |
| 131 | 11 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation) |
| 132 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
| 133 | Cable jointing kit straight through (3x185) |
| 134 | Extra Prefabricated Items Like Clamp , Channel, Angle with Nut bolt |
| 135 | ERECTION PART |
| 136 | Conversion of existing Service Cable to New Armoured Service cable with all required accessories like J-pipe , shaddle , Conduit Pipe ,clamp ,GI wire , Reel insulator , Earthing bolt and lugs etc.(Complete Work in all respect) and Removing and shifting of Existing Material to client store |
| 137 | Armoured Service Cable 2CX4 SQMM For Single phase consumer |
| 138 | Armoured Service Cable 2CX6 SQMM For Single phase consumer |
| 139 | Armoured Service Cable 4CX10 SQMM For Three phase consumer |
| 140 | Armoured Service Cable 4CX16 SQMM For Three phase consumer |
| 141 | Erection, Testingand commissioning of Replacement ofLT Bare Conductor with AB Cables (Complete Work in all respect) |
| 142 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 143 | 9 Meter long STP as per Approved Drawing and Technical specification (SP-33) |
| 144 | Stone Pad (300x300x75mm) |
| 145 | LT ABC 3x120+1x95+1x16 sq.mm. (Bare Massenger Wire) |
| 146 | LT ABC 3x95+1x70+1x16 sq.mm. (Bare Massenger Wire) |
| 147 | LT ABC 3x50+1x35+1x16 sq.mm. (Bare Massenger Wire) |
| 148 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
| 149 | Dead End clamp (Insulated) |
| 150 | Suspension clamps (Insulated) |
| 151 | Insulating Piercing Connector (16-150 sq.mm) |
| 152 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
| 153 | 1x25 mm2 PVC insulated Al. LT Cable for energising the distribution boxes. |
| 154 | Single Phase Distribution Box with clamps (Deep Drawn Type) - 1 Incoming and 8 outgoing |
| 155 | Three Phase Distribution Box with clamps (Deep Drawn Type) 1 Incoming and 4 outgoing |
| 156 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 157 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 158 | LT Guy Insulator |
| 159 | GI Stay Wire 7/10 SWG |
| 160 | LT Stay Clamp as per approved drawing |
| 161 | Removing and shifting of Existing Material to client store |
| 162 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 163 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing |
| 164 | Erection, Testingand commissioning of Replacement ofAB Cable (Damage)with AB Cables (Complete Work in all respect) |
| 165 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 166 | 9 Meter long STP as per Approved Drawing and Technical specification (SP-33) |
| 167 | Stone Pad (300x300x75mm) |
| 168 | LT ABC 3x120+1x95+1x16 sq.mm. (Bare Massenger Wire) |
| 169 | LT ABC 3x95+1x70+1x16 sq.mm. (Bare Massenger Wire) |
| 170 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
| 171 | Dead End clamp (Insulated) |
| 172 | Suspension clamps (Insulated) |
| 173 | Insulating Piercing Connector (16-150 sq.mm) |
| 174 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
| 175 | 1x25 mm2 PVC insulated Al. LT Cable for energising the distribution boxes. |
| 176 | Single Phase Distribution Box with clamps (Deep Drawn Type) - 1 Incoming and 8 outgoing |
| 177 | Three Phase Distribution Box with clamps (Deep Drawn Type) 1 Incoming and 4 outgoing |
| 178 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 179 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 180 | LT Guy Insulator |
| 181 | GI Stay Wire 7/10 SWG |
| 182 | LT Stay Clamp as per approved drawing |
| 183 | Removing and shifting of Existing Material to client store |
| 184 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 185 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing |
| 186 | Erection, Testingand commissioning of Replacement of LT Line with XLPE Armoured Cables (Complete Work in all respect) |
| 187 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 188 | 9 Meter long STP as per Approved Drawing and Technical specification (SP-33) |
| 189 | Stone Pad (300x300x75mm) |
| 190 | Angle for vertical ArmL50x50x6 (Type -A)-900MM |
| 191 | Top Clamp for Vertical arm L 50X6 (Type -A)- 435 mm |
| 192 | Bottom Clamp for Vertical arm L 50X6 (Type -A)- 507 mm |
| 193 | Angle for vertical ArmL50x50x6 (Type -B)- 900MM |
| 194 | Top Clamp for Vertical arm L 50X6 (Type -B)- 435 mm |
| 195 | Bottom Clamp for Vertical arm L 50X6 (Type -B)- 507 mm |
| 196 | LT Shackle Insulator |
| 197 | D-Straps |
| 198 | 1 core (Al.) 120mm2 LT Armoured XLPE Cable |
| 199 | 1 core (Al.) 95mm2 LT Armoured XLPE Cable |
| 200 | 1 core (Al.) 50mm2 LT Armoured XLPE Cable |
| 201 | 1 core (Al.) 25mm2 LT Armoured XLPE Cable |
| 202 | Mid Span Joint 120mm2 |
| 203 | Insulating Piercing Connector (50-150 sq.mm) |
| 204 | Insulation mastic tape (2inc X 10 feet). |
| 205 | Single Phase Distribution Box with clamps (Deep Drawn Type) - 1 Incoming and 8 outgoing |
| 206 | Three Phase Distribution Box with clamps (Deep Drawn Type) 1 Incoming and 4 outgoing |
| 207 | 1x25 mm2 Armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
| 208 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 209 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 210 | LT Guy Insulator |
| 211 | GI Stay Wire 7/10 SWG |
| 212 | LT Stay Clamp as per approved drawing |
| 213 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 214 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing |
| 215 | Removing and shifting of Existing Material to client store |
| 216 | Survey , Erection, Testingand commissioning of 11 Kv Line (Feeder Spliting Due to over loading) on 8.5 Mtr PCC pole-115.6 CKM and 11 Mtr STP Pole -151.4 CKM (Complete Work in all respect) |
| 217 | Route survey and pole spotting for 11 KV line |
| 218 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 219 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
| 220 | ACSR Rabbit Conductor |
| 221 | Stone Pad (300x300x75mm) |
| 222 | 11 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm ) |
| 223 | 11 KV Cross arm holding clamps with bolts & nuts |
| 224 | F- Bracket for 11 KV line |
| 225 | M.S. Top channel 100x50x6 mm., 2240 mmlong |
| 226 | Clamp FOR Top Channel with Nut bolt |
| 227 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
| 228 | E- Bracket for 11 KV line |
| 229 | 11 KV Pin Insulator Polymer Type as per TS |
| 230 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 231 | 11 KV Disc Fitting B & S type (45 KN) |
| 232 | PG Clamp for Rabbit |
| 233 | Aluminium binding wire - 6 SWG |
| 234 | Jointing sleave |
| 235 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 236 | G.I. Barbed Wire |
| 237 | Aluminium paint |
| 238 | Red Oxide Paint |
| 239 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 240 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 241 | HT Guy Insulator |
| 242 | GI Stay Wire 7/10 SWG |
| 243 | HT Stay Clamp as per approved drawing-11 KV |
| 244 | 11 KV Number Plate with Clamp and Nuts & Bolts |
| 245 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 246 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
| 247 | Erection, Testingand commissioning of 11 KV VCB with complete Assoceries as apporoved Drawing and Tecchanical Specifiactions (Complete Work in all respect) |
| 248 | 11 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation) |
| 249 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
| 250 | Smart TVM Meter Compatible with System (AMI) complete Set |
| 251 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 252 | GI Flat 50X6 for Earthing |
| 253 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 254 | Stone Pad (300x300x75mm) |
| 255 | M.S. Top channel 100x50x6 mm., 2240 mmlong |
| 256 | Clamp FOR Top Channel with Nut bolt |
| 257 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
| 258 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 259 | 11 KV Disc Fitting B & S type (45 KN) |
| 260 | PG Clamp for Rabbit |
| 261 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 262 | G.I. Barbed Wire |
| 263 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 264 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 265 | HT Guy Insulator |
| 266 | GI Stay Wire 7/10 SWG |
| 267 | HT Stay Clamp as per approved drawing-11 KV |
| 268 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 269 | Survey , Erection, Testingand commissioning of 11 Kv Line (Feeder Sagrigation) (Complete Work in all respect) |
| 270 | Route survey and pole spotting for 11 KV line |
| 271 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 272 | ACSR Rabbit Conductor |
| 273 | Stone Pad (300x300x75mm) |
| 274 | 11 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm ) |
| 275 | 11 KV Cross arm holding clamps with bolts & nuts |
| 276 | F- Bracket for 11 KV line |
| 277 | M.S. Top channel 100x50x6 mm., 2240 mmlong |
| 278 | Clamp FOR Top Channel with Nut bolt |
| 279 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
| 280 | E- Bracket for 11 KV line |
| 281 | 11 KV Pin Insulator Polymer Type as per TS |
| 282 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 283 | 11 KV Disc Fitting B & S type (45 KN) |
| 284 | PG Clamp for Rabbit |
| 285 | Aluminium binding wire - 6 SWG |
| 286 | Jointing sleave |
| 287 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 288 | G.I. Barbed Wire |
| 289 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 290 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 291 | HT Guy Insulator |
| 292 | GI Stay Wire 7/10 SWG |
| 293 | HT Stay Clamp as per approved drawing-11 KV |
| 294 | 11 KV Number Plate with Clamp and Nuts & Bolts |
| 295 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 296 | Erection, Testingand commissioning of 11 KV VCB with complete Assoceries as apporoved Drawing and Tecchanical Specifiactions(Feeder Segrigation) (Complete Work in all respect) |
| 297 | 11 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation) |
| 298 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
| 299 | Smart TVM Meter Compatible with System (AMI) complete Set |
| 300 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 301 | GI Flat 50X6 for Earthing |
| 302 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 303 | Stone Pad (300x300x75mm) |
| 304 | M.S. Top channel 100x50x6 mm., 2240 mmlong |
| 305 | Clamp FOR Top Channel with Nut bolt |
| 306 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
| 307 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 308 | 11 KV Disc Fitting B & S type (45 KN) |
| 309 | PG Clamp for Rabbit |
| 310 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 311 | G.I. Barbed Wire |
| 312 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 313 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 314 | HT Guy Insulator |
| 315 | GI Stay Wire 7/10 SWG |
| 316 | HT Stay Clamp as per approved drawing-11 KV |
| 317 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 318 | Erection, Testingand commissioning of 11 KV NH Crossing (Complete Work in all respect) |
| 319 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
| 320 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
| 321 | HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc |
| 322 | GI Pipe 6\" Diameter with clamps |
| 323 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
| 324 | GI Angle Iron 50x50x6 mm bracing with 4 clamps |
| 325 | M.S. Top channel 100x50x6 mm., 2240 mmlong |
| 326 | Clamp FOR Top Channel with Nut bolt |
| 327 | G.I. Barbed Wire |
| 328 | Stone Pad (300x300x75mm) |
| 329 | 11 KV Pin Insulator Polymer Type as per TS |
| 330 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 331 | 11 KV Disc Fitting B & S type (45 KN) |
| 332 | PG Clamp for Rabbit |
| 333 | E- Bracket for 11 KV line |
| 334 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 335 | Aluminium paint |
| 336 | Red Oxide Paint |
| 337 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 338 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 339 | HT Guy Insulator |
| 340 | GI Stay Wire 7/10 SWG |
| 341 | HT Stay Clamp as per approved drawing-11 KV |
| 342 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
| 343 | Cable laying including cost of material eg. , Bricks, Sand, clamps etc. |
| 344 | Erection, Testingand commissioning of 11 KV Railway Crossing (Complete Work in all respect) |
| 345 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
| 346 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
| 347 | HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc |
| 348 | GI Pipe 6\" Diameter with clamps |
| 349 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
| 350 | GI Angle Iron 50x50x6 mm bracing with 4 clamps |
| 351 | M.S. Top channel 100x50x6 mm., 2240 mmlong |
| 352 | Clamp FOR Top Channel with Nut bolt |
| 353 | G.I. Barbed Wire |
| 354 | Stone Pad (300x300x75mm) |
| 355 | 11 KV Pin Insulator Polymer Type as per TS |
| 356 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 357 | 11 KV Disc Fitting B & S type (45 KN) |
| 358 | PG Clamp for Rabbit |
| 359 | E- Bracket for 11 KV line |
| 360 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 361 | Aluminium paint |
| 362 | Red Oxide Paint |
| 363 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 364 | 9 KV LA , 10 KA (Station Class) |
| 365 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 366 | HT Guy Insulator |
| 367 | GI Stay Wire 7/10 SWG |
| 368 | HT Stay Clamp as per approved drawing-11 KV |
| 369 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
| 370 | Cable laying including cost of material eg. , Bricks, Sand, clamps etc. |
| 371 | Erection, Testingand commissioning of 11 kV Line crossing by 33kV Lines on STP 13 Mtr with Cradle Guarding (Complete Work in all respect) |
| 372 | 13 Meter long STP as per Approved Drawing and Technical specification (SP-72) |
| 373 | 33 KV Steel X-arm V type (GI Channel 100 X 50 X 6 mm ) |
| 374 | 33 KV Cross arm holding clamps with bolts & nuts |
| 375 | 33 KV Pin Insulator |
| 376 | 33 KV G.I. Pin (10 KN) with nuts & washers |
| 377 | GI. guarding Angle 75x75x6 mm 3010 mm long with Clamp |
| 378 | F- Bracket for 33 KV line |
| 379 | Turn buckle |
| 380 | G.I. Wire 6 SWG |
| 381 | G.I. Wire 8 SWG |
| 382 | G.I. Wire No. 16 SWG for binding |
| 383 | Eye Bolt |
| 384 | Armour rod with ferrules for ACSR Rabbit/Weasel Helical Performed |
| 385 | Stone Pad (300x300x75mm) |
| 386 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 387 | 11 KV Number Plate with Clamp and Nuts & Bolts |
| 388 | G.I. Barbed Wire |
| 389 | Red Oxide Paint |
| 390 | Aluminium paint |
| 391 | Aluminium binding wire - 6 SWG |
| 392 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 393 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 394 | 33 KV Stay Complete (GI Stay Rod 20x1800 mm,Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 395 | HT Guy Insulator |
| 396 | GI Stay Wire 7/8 SWG |
| 397 | HT Stay Clamp as per approved drawing-33 KV |
| 398 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.64 Cmt (13 Meter - STP ) as per approved Drawing |
| 399 | Erection, Testingand commissioning of LT Line crossing by 11 kV Lines on STP 11 Mtr with Cradle Guarding (Complete Work in all respect) |
| 400 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
| 401 | 11 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm ) |
| 402 | 11 KV Cross arm holding clamps with bolts & nuts |
| 403 | 11 KV Pin Insulator Polymer Type as per TS |
| 404 | F- Bracket for 11 KV line |
| 405 | Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp |
| 406 | Turn buckle |
| 407 | G.I. Wire 6 SWG |
| 408 | G.I. Wire 8 SWG |
| 409 | G.I. Wire No. 16 SWG for binding |
| 410 | Eye Bolt |
| 411 | Armour rod with ferrules for ACSR Rabbit/Weasel Helical Performed |
| 412 | Stone Pad (300x300x75mm) |
| 413 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 414 | 11 KV Number Plate with Clamp and Nuts & Bolts |
| 415 | G.I. Barbed Wire |
| 416 | Red Oxide Paint |
| 417 | Aluminium paint |
| 418 | Aluminium binding wire - 6 SWG |
| 419 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 420 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 421 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 422 | HT Guy Insulator |
| 423 | GI Stay Wire 7/8 SWG |
| 424 | HT Stay Clamp as per approved drawing-11 KV |
| 425 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
| 426 | Erection, Testingand commissioning of UG Cable 11 KV Line (Complete Work in all respect) |
| 427 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
| 428 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
| 429 | Cable jointing kit straight through (3x185) |
| 430 | GI Pipe 6\" Diameter with clamps |
| 431 | Cable Route Marker |
| 432 | HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc |
| 433 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
| 434 | GI Angle Iron 50x50x6 mm bracing with 4 clamps |
| 435 | M.S. Top channel 100x50x6 mm., 2240 mmlong |
| 436 | Clamp FOR Top Channel with Nut bolt |
| 437 | G.I. Barbed Wire |
| 438 | Stone Pad (300x300x75mm) |
| 439 | 11 KV Pin Insulator Polymer Type as per TS |
| 440 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 441 | 11 KV Disc Fitting B & S type (45 KN) |
| 442 | PG Clamp for Rabbit |
| 443 | E- Bracket for 11 KV line |
| 444 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 445 | Aluminium paint |
| 446 | Red Oxide Paint |
| 447 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 448 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 449 | HT Guy Insulator |
| 450 | GI Stay Wire 7/10 SWG |
| 451 | HT Stay Clamp as per approved drawing-11 KV |
| 452 | Road Restoration Chages forRoad Crossing |
| 453 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
| 454 | Erection, Testingand commissioningof 11/0.433 KV three phase Transformer sub-station -25 KVA ,63 KVA and 100 KVA (Complete Work in all respect) |
| 455 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 456 | GI Channel 100x50x6 mm 2028 mm long (For Fuse Set ) |
| 457 | Stone Pad (300x300x75mm) |
| 458 | Clamps for LT T-off with bolts & nuts |
| 459 | Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts |
| 460 | GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base) |
| 461 | M.S. Top channel 125x65x6 mm., 2240 mmlong |
| 462 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 463 | 11 KV Disc Fitting B & S type (45 KN) |
| 464 | Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt |
| 465 | 11 KV Pin Insulator Polymer Type as per TS |
| 466 | 25 KVA , 11/0.433 KV T/F (BEE Standard 3 Star Rating Self Protected Aluminium Wound Type) |
| 467 | 63 KVA , 11/0.433 KV T/F (BEE Standard 3 Star Rating Self Protected Aluminium Wound Type) |
| 468 | 100 KVA , 11/0.433 KV T/F (BEE Standard 3 Star Rating Self Protected Aluminium Wound Type) |
| 469 | 11KV TPMO with fixing clamps |
| 470 | 11KV Fuse Set (Drop out) with clamps |
| 471 | 9 KV LA , 5 KA (Distribution Class) |
| 472 | LT incoming Panel with AMI metering (Smart Meter compitable with System) equipment & fixing arrangement (As per TS ). (Deep Drawn Type) for 25KVA |
| 473 | LT incoming Panel with AMI metering (Smart Meter compitable with System) equipment & fixing arrangement (As per TS ). (Deep Drawn Type) for 63 KVA |
| 474 | LT incoming Panel with AMI metering (Smart Meter compitable with System) equipment & fixing arrangement (As per TS ). (Deep Drawn Type) for 100KVA |
| 475 | LT PVC cable 4x16 Sq mm |
| 476 | LT PVC cable 3.5x70 Sq mm |
| 477 | LT PVC cable 3.5x150 Sq mm |
| 478 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 479 | G.I. Barbed Wire |
| 480 | ACSR Rabbit Conductor- Jumpering Works |
| 481 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 482 | HT Guy Insulator |
| 483 | GI Stay Wire 7/10 SWG |
| 484 | HT Stay Clamp as per approved drawing-11 KV |
| 485 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 486 | GI Flat 25X3 for Earthing |
| 487 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 488 | Erection, Testingand commissioningof 11/0.433 KV three phase Transformer sub-station -10 KVA and 16 KVA (Complete Work in all respect) |
| 489 | 10 KVA, 11KV/250 V, 1 Ph Transformer as BEE standard (Self protected). |
| 490 | 16 KVA, 11KV/250 V, 1 Ph Transformer as BEE standard (Self protected). |
| 491 | LT Distribution Box withMCCB for protection of 10 KVA T/F and Bus Bar foroutgoing consumer connections and suitable to house Energy meter (without Energy meter) (Deep drawn Type) as per TS. |
| 492 | LT Distribution Box withMCCB for protection of 16 KVA T/F and Bus Bar foroutgoing consumer connections and suitable to house Energy meter (without Energy meter) (Deep drawn Type) as per TS. |
| 493 | Clamps for Dist. Box (40x6 mm) |
| 494 | Clamps for T/F (75x8 mm GI flat). |
| 495 | ACSR Weasel Conductor-Jumpering Works |
| 496 | 11 KV Pin Insulator Polymer Type as per TS |
| 497 | Eye Bolt |
| 498 | L.T. PVC cable 10 Sq. mm Single Core |
| 499 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 500 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 501 | HT Guy Insulator |
| 502 | GI Stay Wire 7/10 SWG |
| 503 | HT Stay Clamp as per approved drawing-11 KV |
| 504 | Relocation ,Testing and commissioningof 250 KVA ,11/0.433 KV three phase Transformer sub-station(Complete Work in all respect) |
| 505 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
| 506 | GI Channel 100x50x6 mm 2028 mm long (For Fuse Set ) |
| 507 | Stone Pad (300x300x75mm) |
| 508 | Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts |
| 509 | M.S. Top channel 125x65x6 mm., 2240 mmlong |
| 510 | GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base) |
| 511 | GI Channel 75x75x6 mm &bolt and nut (T/F base Support) |
| 512 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 513 | 11 KV Disc Fitting B & S type (45 KN) |
| 514 | Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt |
| 515 | Clamps for LT T-off with bolts & nuts |
| 516 | 11 KV Pin Insulator Polymer Type as per TS |
| 517 | 11KV TPMO with fixing clamps |
| 518 | 11KV Fuse Set (Drop out) with clamps |
| 519 | LT incoming Panel with AMI metering (Smart Meter compitable with System) equipment & fixing arrangement (As per TS). (Deep Drawn Type) for 250KVA |
| 520 | Copper L-Piece 50x225x10mm |
| 521 | Copper L-Piece 50x225x12mm |
| 522 | LT PVC cable 3.5x400 Sq mm |
| 523 | Al Leg long barrel off size |
| 524 | 4 core LT MCB with box |
| 525 | 11 KV Danger Board with Clamp and Nuts & Bolts |
| 526 | G.I. Barbed Wire |
| 527 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 528 | HT Guy Insulator |
| 529 | GI Stay Wire 7/10 SWG |
| 530 | HT Stay Clamp as per approved drawing-11 KV |
| 531 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
| 532 | GI Flat 50X6 for Earthing |
| 533 | GI Channel 125x65 mm |
| 534 | 9 KV LA , 5 KA (Distribution Class) |
| 535 | Crimping type heavy duty aluminium lugs suitable for connection PVC cables |
| 536 | PG Clamp for Rabbit |
| 537 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
| 538 | DT\"s Plinth Foundation |
| 539 | Dismentaling of Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,comissioning and charging and other shifting to store. |
| 540 | Erection, Testingand commissioning of New LT Line With AB Cable(Complete Work in all respect) |
| 541 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
| 542 | Stone Pad (300x300x75mm) |
| 543 | LT ABC 3x50+1x35+1x16 sq.mm. (Bare Massenger Wire) |
| 544 | LT ABC 3x95+1x70+1x16 sq.mm. (Bare Massenger Wire) |
| 545 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
| 546 | Dead End clamp (Insulated) |
| 547 | Suspension clamps (Insulated) |
| 548 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
| 549 | Insulating Piercing Connector (16-150 sq.mm) |
| 550 | 1x25 mm2 PVC insulated Al. LT Cable for energising the distribution boxes. |
| 551 | Single Phase Distribution Box with clamps (Deep Drawn Type) - 1 Incoming and 8 outgoing |
| 552 | Three Phase Distribution Box with clamps (Deep Drawn Type) 1 Incoming and 4 outgoing |
| 553 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 554 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 555 | LT Guy Insulator |
| 556 | GI Stay Wire 7/10 SWG |
| 557 | LT Stay Clamp as per approved drawing |
| 558 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
| 559 | Erection, Testingand commissioning of 11KV Line Guarding (Complete Work in all respect) |
| 560 | Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp |
| 561 | Height raising channel 100x50,2240 mm long |
| 562 | Back clamp for Height raising channel holding clamps with bolts & nuts |
| 563 | G.I. Wire 6 SWG |
| 564 | G.I. Wire 8 SWG |
| 565 | Turn Buckle |
| 566 | Eye Bolt |
| 567 | G.I. Wire No. 16 SWG for binding |
| 568 | Earthing Coil connected with nutbolt using Charchol and Salt |
| 569 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 570 | HT Guy Insulator |
| 571 | GI Stay Wire 7/10 SWG |
| 572 | HT Stay Clamp as per approved drawing-11 KV |
| 573 | Erection, Testingand commissioning of Tee Of Channel (Complete Work in all respect) |
| 574 | GI Channel 100x50x6 mm. 1300 mm long |
| 575 | GI Channel clamp with nuts & bolts |
| 576 | 11 KV Disc. Insulators B&S type 45 KN (Polymer Type) |
| 577 | 11 KV Disc Fitting B & S type (45 KN) |
| 578 | 11 KV Pin Insulator Polymer Type as per TS |
| 579 | PG Clamp for Rabbit |
| 580 | Stay Complete (GI Stay Rod 16x1800 mm, Eye Bolt, Anchor plate,Turn Buckle and thimble) Bolt, Nuts Bolt & Washers |
| 581 | HT Guy Insulator |
| 582 | GI Stay Wire 7/10 SWG |
| 583 | HT Stay Clamp as per approved drawing-11 KV |
| 584 | Control Room Building Extention work (Complete Work in all respect) |
| 585 | RCC Work of Building with Internal wiring works for Extension of Control room Building (36 Sqmm) (Complete Works in all respect) as per approved drawing and specification |
| 586 | Water pump, Toilet works as per approved drawing and specification |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail