Conversion Of Low Tension Oh Line To Underground Cable At Csd Depot Secunderabad, Provn Of Automatic Fire Alarm System At Icu & Ot And Flame Proof Wiring Alongwith Flame Proof Light Fittings And Lightning Protection At Oxygen Generator Room At Mh Secunde, secunderabad-Telangana

Military Engineer Services-MES has published Conversion Of Low Tension Oh Line To Underground Cable At Csd Depot Secunderabad, Provn Of Automatic Fire Alarm System At Icu & Ot And Flame Proof Wiring Alongwith Flame Proof Light Fittings And Lightning Protection At Oxygen Generator Room At Mh Secunde. Submission Date for this Tender is 17-05-2022. Alarm Systems Tenders in secunderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

32027280
Conversion Of Low Tension Oh Line To Underground Cable At Csd Depot Secunderabad, Provn Of Automatic Fire Alarm System At Icu & Ot And Flame Proof Wiring Alongwith Flame Proof Light Fittings And Lightning Protection At Oxygen Generator Room At Mh Secunde
Open Tender
Indian
Telangana
secunderabad
17-05-2022

Tender Details

Conversion Of Low Tension Oh Line To Underground Cable At Csd Depot Secunderabad, Provn Of Automatic Fire Alarm System At Icu & Ot And Flame Proof Wiring Alongwith Flame Proof Light Fittings And Lightning Protection At Oxygen Generator Room At Mh Secunderabad Under Age E / M No Ii Of Ge ( U ) Secunderabad

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work:CONVERSION OF LOW TENSION OH LINE TO UNDERGROUND CABLE AT CSD DEPOT SECUNDERABAD, PROVN OF AUTOMATIC FIRE ALARM SYSTEM AT ICU & OT AND FLAME PROOF WIRING ALONGWITH FLAME PROOF LIGHT FITTINGS AND LIGHTNING PROTECTION AT OXYGEN GENERATOR ROOM AT MH SECUNDERABAD UNDER AGE E/M NO II OF GE (U) SECUNDERABAD
Sl. No. Item Description
1Design, supply, installation, testingand commissioning of CPRI APPROVED factoryfabricated, out door type, LT FEEDER PILLAR BOX IP 55 protection grade, made out of 3.15 mm thick CRCA Sheetwith projected Globe roof for rain water protection Dust and Vermin Proof,Double door withboth side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, cable glands of appropriate size, etc. and supportedwith 65X65X6mm Mild Steel Angle Iron Frameand 500 mm above ground lavel, embeded in PCC 1:2:4, type C-2, 45 Cm below ground level and 50 CM above ground levelcomplete with internal connection with suitable size of strip, cable lugs and cable glands and Testing after installation complete all as specified and comprising of the following :- (Size of the panel board should not be less than 1.15 M X1.5 MX0.40M)
2(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of "F" class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 300 Amps for phases andNeural, set of 4 for RYB &N - 01 set. (b)MCCB 4 Pole 160 Amps 36KA -01 No. Thermal Magnetic release (incommer) (c)MCCB 4 Pole 125 Amps 18KA -02 Nos. (Outgoing) (d) MCCB 4 Pole 63 Amp 18 KA-04 Nos (Outgoing) (e) MCB 4 Pole 32 Amp 18KA-03 Nos (Outgoing) (f) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (g) Indicating type lamp for Red, Yellow and Blue phases - 01 Set
3Design, supply, installation, testingand commissioning CPRI APPROVED factoryfabricated, out door type, LT FEEDER PILLAR BOX IP 55 protection grade, made out of 3.15 mm thick CRCA Sheetwith projected Globe roof for rain water protection Dust and Vermin Proof,Double door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, cable glands of appropriate size, etc. and supportedwith 65X65X6mm Mild Steel Angle Iron Frameand 500 mm above ground lavel, embeded in PCC 1:2:4, type C-2, 45 CM below ground level and 50 CM above ground levelcomplete with internal connection with suitable size of strip ,cable lugs and cable glands and Testing after installation complete all as specified and comprising of the following :- (Size of the panel board should not be less than 1.15M X1.0MX0.35M)
4(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of "F" class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 200 Amps for phases andNeutral, set of 4 for RYB &N - 01 set. (b)MCCB 4 Pole 100 Amps 18KA -02 No. Thermal Magnetic release (incommer) (c) Onload Changeover 4 pole 415 Volt front operated panelmounted - 01 Nos (d)MCCB 4 Pole 63Amps 16KA -03 Nos. (Outgoing) (e) MCB 32 Amps SPN - 2 Nos (f) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (g) Indicating type lamp for Red, Yellow and Blue phases - 01 Set
5Design, supply, installation, testingand commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX IP 55 protection grade, made out of 3.15 mm thick CRCA Sheetwith projected Globe roof for rain water protection Dust and Vermin Proof, Double door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, cable glands of appropriate size, etc. and supportedwith 65X65X6mm Mild Steel Angle Iron Frameand 500 mm above ground lavel, embeded in PCC 1:2:4, type C-2, 45 CM below ground level and 50 CM above ground levelcomplete withinternal connection with suitable size of strip, cable lugs and cable glands and Testing after installationcomplete all as specified and comprising of the following :- (Size of the panel board should not be less than 1.15M X1.0MX0.35M)
6(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of "F" class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 200 Amps for phases andNeural, set of 4 for RYB &N - 01 set. (b)MCCB 4 Pole 63 Amps 16KA -01 No. Thermal Magnetic release (incommer) (c)MCCB 4 Pole 32 Amps 16KA -05 Nos. (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (e) Indicating type lamp for Red, Yellow and Blue phases - 01 Set
7Design, supply, installation, testingand commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX IP 55 protection grade, made out of 3.15 mm thick CRCA Sheetwith projected Globe roof for rain water protection Dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, cable glands of appropriate size, etc. and supported with 65X65X6mm Mild Steel Angle Iron Frame and 500 mm above ground lavel, embeded in PCC 1:2:4, type C-2, 45 CM below ground level and 50 CM above ground level complete with internal connection with suitable size of strip ,cable lugs and cable glands and Testing after installation complete all as specified and comprising of the following :- (Size of the panel board should not be less than 0.90 M X1.05 MX0.35M)
8(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of "F" class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 200 Amps for phases andNeural, set of 4 for RYB & N - 01 set. (b) MCCB, 415 V, 50 Hz, 4 Pole, 100 Amp, 36 KA breaking capacity with adjustable thermal and magnetic settings - 01 No (Incoming). (c) MCB, 415 V, 50 Hz, 3 Pole 40 Amp,10 KA breaking capacity - 05 Nos (Outgoing). (d) Voltmeter 0-500V with selector switch- 01 No. (e) Indicator lamp with Holder 3 Nos - 1 set. (f) Ammeter with CT ratio 200/5 Amps with selector switch - 01 No.
9Notes for Sl item Nos 1 to 4 :- (i) All incoming and outgoing cables are to be connected to the abovepanels with proper lugs, double compression copper stain less steel armoured cable gland, nuts, bolts etc the cost of the itemsdeemed to be included in the quoted rates. (ii)Make of MCCB"s and MCB"s to be used in the panels are : L&T / Legrand /Siemens /Havells or equivalent as approved by GE. (iii)The panel shall be Fabricated from a reputed firm(CPRI Approved) . (iv)All Internal connection between ACB, MCCB (ABOVE 63 AMPS)and Changeover and Bus bar shall be done by aluminium strip of suitable size and capacity . (v) All MCCB to be connected with both side Spreader Linkandall Incomer and outgoingMCCB of Panels should be thermal magnetic release with adjustable settings ( Min 70 5 to 100 %)and Ics = 100% Icu (vi) Sufficient space to be provided for cable connection between MCCB and Bottom of the panel board.( Minimum space for MCCB up to 200 amps = 30 CM ) (vii)Base of the panel should not be less than 500 mm above the ground level. Necessary PCC for base /foundation required deemed to be included in the quoted rate. (viii)Cable alley / chamber to along with connector of suitable sizeto be providedfor connection of Outgoing cable . (ix)Necessary approval of drawing to be taken from GE before placing order to the manufacturer. (x)All existing incoming and outgoing cables also to be connected to the abovepanelas per site requirementwith proper lugs, glands nuts, bolts etc (xi)Door hinge of industrial type heavy duty to be provided minimum 3 Nos for each door ((xii) The rate shall deemed to be included in the item rate for all the points mentioned above.
10Supply and lay in trenches/fixed to walls/poles etc connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured underground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed
11All as per item No 5 here-in-before but 2 Core 10 Sqmm
12All as per item No 5 here-in-before but 4.0 Core 25 Sqmm
13All as per item No 5 here-in-before but 3.5 Core 35 Sqmm
14All as per item No 5 here-in-before but 3.5 Core 50 Sqmm
15All as per item No 5 here-in-before but 3.5 Core 70 Sqmm
16All as per item No 5 here-in-before but 3.5 Core 95 Sqmm
17Supply and fixed to walls using saddle of appropriate sizeetc connecting buy using lugs, testingand commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade UN ARMOUREDcable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed
18Supply and fixed to walls using saddle of appropriate sizeetc connecting buy using lugs, testingand commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade UN ARMOUREDcable with stranded aluminium conductor 2 Core 10 Sqmm complete all, as specified and directed
19Supply and lay pipe galvanized, “ Light grade”, including fittings, 40mm (1.5”) dia for protection of cable complete all as specified and directed
20Supply and lay pipe galvanized, “Light grade”, including fittings, 50mm (2”) dia for protection of cable complete all as specified and directed
21Supply and lay pipe galvanized, “Light grade”, including fittings, 80mm (3”) dia for protection of cable complete all as specified and directed
22Supplying and laying of following sizeHDPE pipepn 10 ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground, wall, floor complete all as directed
2340 mm
2450 mm
2575 mm
26S&F on wall with necessary arrangements busbar chamber 100 amps 4 way4 polewall mounted IP -31, made out of 1.6 mm thick CRCA sheet epoxy powder coated single layer operational voltage 440 Volt, Short circuit current capacity 25 KA for 1 Secondincluding necessary cable connectionscompleteall as specified and directed. Note: Quoted rates shall deemed to be inclusive of necessary fixing arrangement and cable connections, cable glands as required for proper fixing / functioning of Bus Bar Chamber. Make : Havells/HPL/Standard
27S&F MCCBbox made of CRCAsheet of 2mm thick size 40X30X20 CM Powder coated Suitable for fixing at Pole including two set of clamps / wall by using anchor bolt comprising MCCB32 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK complete all as specified and directed.
28M&L for drawing two runs ofPVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia PVC conduit exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, 3 sets of clamps of suitable size for supporting on pole etc complete all as specified & directed. Note: The above mentioned wire to be used for connection of lights from Junction box. Quoted rates shall deemed to be inclusive of clamps of suitable size required for the same .
29M&L for drawing two runs ofPVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 2.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 2.50 sq mm including 20mm dia concealedPVC conduit medium grade exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, etc complete all as specified and directed.
30M&L for drawing fourruns ofPVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 4.0 sq mm with tworun of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 4.0 sq mm including 25mm dia concealedPVC conduit medium grade exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, etc complete all as specified and directed.
31Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Densesoil complete all as specified and directed.
32Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
33Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
34Spreading riddled earth ( after preparation of excavated earth) in Cable duct forcushioning of cable laid in trenches complete all as directed by Engr-in-Charge. Note:- Punned thickness 18 CM( 6.25 Cm below cable and 11.75 cm above cable)will be measured for payment purpose. The earth removed during excavation to be used as riddled earth after crushing and sieving. Quoted rate inclusive of all arrangement as mentioned.
35Supply and Laying bricks, common burnt clay building bricks, sub class "B" of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
36S&F galvanised steel strip 32X6 mm with saddles and fixing screws and joining the same with existing earth test point all as directed by Engr-in-Charge.
37S&F galvanised wire 4 mm dia along with protection pipe 15 mm dia light grade and joining the same with existing earth test point all as directed by Engr-in-Charge.
38S&F of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. The sensor along with suitable power contactors incoming outgoing MCBS SP and auto manual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 three phase load of 08 KW with Circuit wiringmin 10 sqmm 3 Nos contactor each of 20-25 amps incoming outgoing MCB (3 Nos) rating 20-25 amps Model No Swadeep-02 EC 8KW 1P or equivalent as approved by GE.
39S&F hot press moulded SMC junction/terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 4 way connector 415 Volts, 32 Ampsmade out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs and glands, fixied on pole by means of 2 sets of clamps made out of MS flat iron of size 25 mm x 3 mm completeall as specified and as directed.
40M&L for Making hole 2 Nos (one hole near JB another hole near bottom portion of bracket) on existing steel tubular pole (SP -31) of suitable size for passing of Street light connection HV Round cable 3 core 1.5 / 2.5 Sqmm from Junction Box to street light complete all as directed
41Partially demolition of coping of pole as requiredfor placing of cable protection pipe and making good the same by using PCC and renderingcomplete al as specified and directed. Note: Quoted rates shall deemed to be inclusive of PCC and rendering.
42Disconnection existing LT UG cable of any sizefrom pole/OH line and connect the same to feeder piller box by using cable lugs etc as required complete all as directed
43Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use within 50m
44Dismantling insulators any type, any size
45Dismantling stay assembly complete.(demolition of concrete, etc. and excavation measured separately)
46Dismantling of ACSR or AAC conductors
47Dismantling of Service wire of any size and type
48S&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
49S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
50S&F LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistantprotection, with impact and corrosion resistant complete with driver and lamp.
51S&F LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistantprotection, with impact and corrosion resistant complete with driver and lamp.
52S&F sheet metal enclosure Distribution Board SPN 4 way double door fixed flush to wall including cutting the wall and making good of disturbed surface and necessary painting to match with the adjoining area complete all as directed.
53S&F sheet metal enclosure Distribution Board SPN 8 way double door fixed flush to wall including cutting the wall and making good of disturbed surface and necessary painting to match with the adjoining area complete all as directed.
54S&F RCBO Double pole 100 mA 32 Ampscomplete all as specified and directed
55S&F RCBO fourpole 100 mA 32 Ampscomplete all as specified and directed
56M&L for chess cutting in existing wall of any kind by using appropriate mechanical means and fix 25 mm dia medium grade PVC Conduit including necessary bend suitable for submain wiring including making good of disturbed surface and necessary painting to match with the adjoining surface completeall as specified and directed
57Fabrication and installation of GI pipe bracket made of medium Grade tubing of size 40 mm dia, duly bended by hot forgoing after filling of sand, length 1.20 mtr including providing two pair of MS flat strip clamps 40 mm x 4 mm with GI bolts nuts and washer complete all as specified and directed
58M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPE pipeupto 75 mm diaof max length 15 mincluding jointing materials to carry LT UG cables of size upto95 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed including refilling and making good of disturbed surface . Note : Quoted rateshall deemed to be exclusive ofHDPE pipe but shall deemed to be inclusive of necessary machinaries required for the above work
59M&L for twin core 1100 volt grade aluminium service wire cross sectional area 2.5Sqmmfor connection of light complete all as specified and directed
60M&L for twin core 1100 volt grade aluminium service wire cross sectional area 4.0 Sqmmfor connection of light complete all as specified and directed
61Taking down serviceable street light fittings of any watt and type from existing position on pole/ wall/ tower including bracket / clamp and refix the same at new location in pole complete all as specified and directed.
62Supply, fixing, connecting and testingpost top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically designed aluminium decorative luminaries with high power LED as light source of capacity1X35/40 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed. Note : Quoted rates shall deemed to be inclusive of 63 mm GI /MSpipe including necessary fixing arrangementas required for fixing of gate light at gate pillar. Make:-Philips Cat Part No BGP161 LED2500/NW PSU 220-240V 7043 IN or CG Model No LPTO 40 CDL/ Surya Model lP07 501-XXX-57-CL/ Havells Cat No. RUBYPT35WLED757PSYMTOPC or Wipro catNo.LP07-501-XXX-57-CL as approved by GE.
63M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including thoroughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
64M&L for Painting the existing LT PCC poles with 1 coats of synthetic enamel base paintincluding painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 meters height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
65Supply and lay PVC Insulated, PVCsheathed industrial HV round multicore flexible cable withcopper conductor 3 core 1.5 sqmm including flexible pipes, fittings and fixtures as required for connection of light fittings at pole from Junction box. (Item to be used for connection of street light From Junction box through inside the steel tubuler pole)
66M&L Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, as in sub base in flooring ,finished even etc etc. including Use and Waste of Formwork (if required), complete all as specified and as directed.
67M&L Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Side Wall of Cable Duct,for flooring of pump house, complete including necessary form work complete all as specified and as directed.
68Supply, fixing and testing of wireless photo electric SMOKEAND HEAT detector comprising with following specification complete all as specified and directed. Specifications:- (a) Cover range : 50 Cubic meter to 100 Cubic meter (b) Battery type :Lithium Battery CR123 as main battery and CR2032 as secondary battery 3V CR 123A (c) Battery expected life : 5 year (main battery) (d) alarm Temperature : +58 oC (e) Operating temperature : -10 oC to + 55 oC (f) Operating environment : Indoor (g) approval : As per latest relevant EN 54 / BIS Specification (h) Sensitivity Smoke Detection unit :- (i)Level 1: 2.0%/m (ii) Level 2: 2.5%/m (iii) Level 3: 23.0%/m (j)Maximum Radiated Power : 5 dBm (3mW) (k)Frequency Band : 865 MHz (l)Operating Frequency Channel : 7 (m) Radio Transmission Range :< 150m (In Open / Obstruction free space)
69Supply, Commissioning and testing of Wireless Control Panel Supports 64 wireless Zones, Up to 32 keypads, 32 ke yfobs, 8 sirens, 4 repeaters, 1 wired zone, 1 wired siren. Supports Zone wise SMS and Voice Calls up to 4 phone numbers. Arming and Disarming through SMS/Call. Built-in Keypad, Battery and Power Supply. Built-in Siren of 85dB, 1 PGM. Supports 3 Areas, 1 Common Area. Two way Talk/Communication / Control - Arm/Disarm/Trouble/Status over GSM/Landline.
70Supply, Installation Commissioning and testing of wireless Siren Strobe : Siren Type : Piezo , 98dB SPL @ 1m, Power supply : Board Lens , Backup battery : Ni-metal , 7.2V , 250mAh : (small batterypack supplied with the siren) or 500 mAH (optional large battery pack) current consumption : 13 mA +- 10% (Standby) 370mA +- 10% (operation) , receiver & Transmitter id type : 24-bit , strobe output: pulsed @1.5sec dimensions (L*W*D) : 350*192*65 mm operating temperature : -20 degree C to 65 degree C (-4 degree F to 149 degree F) weight 940 gms, complete all as specified and directed.
71Make for item No 60 to 62 : Ceasefire//Honeywell or techno commercial equivalent as approved by GE. Note For item No 60 to 62 : Quoted Rates shall deemed to be inclusive of the following :- (i) Detail Design for installation of the wirelessheat / smoke detectors, siren and control panel as per the site condition . (ii) Necessary Electric connection for Siren Strobe and Wire Less Control Panel. (Iii) Testing of Complete System after Installation after every 3 monthly to be done by authorised rep of manufacturer till completion of defect liability period and test report to be submitted duly signed by User, JE, AGE and GE. (iv) Warranty for all the items for two years (v) Make of detector , control panel and siren to be same . (vi) Quoted rates shall deemed to be inclusive of all arrangement required for installation and proper functioningof Detectors, Siren and Control Panel
72M&L for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade in and including ERW, rigid steel conduits of size not less than 20 mm dia (Medium grade) fixed on surface of walls/ceilings as directed with all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed by Engr-in-Charge. Make:- Copper Cable - Polycab/Havells/Finolex/L&T/KEI Steel Conduit-TATA/Jindal/Kalinga/AKG Notes : (i) Cost of junction boxes, if any required, for making new point wiringis deemed to be included in the rates quoted by the contractor for the above item. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of BOQ.
73All as per item No 63 here-in-before but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable for 16 Amps Flame proof Switch and socket complete all as specified and as directed by Engr-in-Charge.
74S&F flame proof16A Single pole ON-OFF /rotary type switch of any description any capacity or make complete all as specified & directed by Eng-in-charge. Make: Cat Part No RI/OA/1010-2A of Sudhir Switchgears Ltd ortechno comercial equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/Bajaj/Philips/Baliga as approved by GE.
75S&F flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified & directed by Engineer-in-Charge. Make– Sudhir Switchgears Ltd/Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/Bajaj/Philips/Baliga as approved by GE.
76S&F flame proof distribution board 8 way single pole & neutral in LM-6 metal enclosures with and including supplying & fixing 01 NoMCBs single pole and neutral 40 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified & directed by Engineer-in-Charge. Note: The cost of MCBs is deemed to be included in the quoted cost. Make : Cat part No MCDB-186 of Sudhir Switchgears Ltd ortechno comercial equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/Bajaj/Philips/Baliga as approved by GE.
77S&F Flame proof weather proof bend 3/4" (20 mm dia bore ) complete all as specified and directed.
78S&F Flame proof weather proof inspection elbow 3/4" complete all as specified and directed.
79S&F Flame proof junction boxes LM-6 with plain cover suitable for 3 Way suitable for 20 mm to 25 mm dia conduit complete all as specified and directed.
80S&F Flame proof junction boxes LM-6 with plain cover suitable for 4 Way suitable for 20 mm to 25 mm dia conduit complete all as specified and directed.
81M&L for Flame proof flexiblemetallic hose conduit 20 mm dia 300 mm long complete all as specified and directed.
82M&F for Flame proof Sub main wiring with 4 runs of 4 sqmm single core, multistranded PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including 20 mm dia steelrigidconduit, conduit fittings and accessories on surface wall/roof/floor with two runs of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified and directed for following size :- NOTE :-4 runs of main wire alongwith 2 run of earth wire and one run of steel conduit pipe shall be measured as one unit.
83S&F LED light fitting 1x16Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. Note : Flexible conduit / junction box will be measured and paid separately.
84S&F LED light fitting 1x08Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED bulk headlight fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. Note : Flexible conduit / junction box will be measured and paid separately.
85S&F wall mounted box made out of 2 mm thick CRCA sheet powder coated of size 70 CM X 60 Cm X 30 CM for fixing of Flameproof DB and Switches including 10 mm thick Bakelite sheet complete all as directed
86M&L for galvanised iron strip of size 32mm x 6 mm buried in ground or fixed on wall with suitable 35 mm size epoxy base insulator fixed on wall / floors fixed at distance / interval not more than 1.0 meter and connected to test point including bending, jointing at test points with 2 Nos GI nuts, bolts, with lead washers, jointing strips at all joints complete all as specified and directed by Engr-in-Charge.
87M&L for aluminium strip of size 25mm x 3mm fixed on PCC block with epoxy based insulator of 35mm size at distance / interval not more than 1.0 meter for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc complete all as specified and directed. Note:(i) Epoxy base insulator and PCC block only will be measured and paid separately underrelevant items (ii) Unit rate quoted is deemed to be inclusive cost of one lead joint and 2 Nos Brass nuts, bolts washers, screws and necessary T&P and machining work required at site.
88Supplyonly epoxy base insulator of suitable size, 35mm height fixed on PCC blocks/ wall or MS angle/ Pipe or on traverse etc complete all as specified and directed by Engineer-in-Charge.
89M&L PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate including necessary form / mould for fair and even surfaces, air termination rod / GI strip etc., complete all as specified and directed. Note : PCC blocks size shall be 150mm x 150mm x 150mm.
90M&L forinspection box / cover box of size 250mm x 150mm x 100mm made out of 3 mm thick MS sheet with hinged front opening cover including provision and fixing 2 Nos epoxy insulators and insulating PVC sheathed for incoming and outgoing aluminium / GI strips for proper insulation etc complete all as specified and directed by Engineer-in-Charge.
91S&F air termination single pointed aluminium rod of 12 mm dia 300 mmlong fixed to aluminium strip 25mm x 3 mm including drilling holes, nuts, bolts washers for resting/ supporting of air terminals etc., complete all as specified and directed.
92Advance Maintenance Free G.I. SAFE EARTHINGElectrodewith PIPEof not less than 50 mm outer dia) and two meterlength, The electrode should be ofgalvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm7.5 m . The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg Backfill compoundto provide maximum contact between the electrode and Backfill Compound. The earthing pitcover should be factory built (sizeTOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch) made of heavy duty Polypropylenecomplete all as specified and directed by Engineer-in-Charge. Make : ASHLOK/INDELEC/JMV/TERCEL/TRUE POWER Note : Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE/AGE/user.Test results are to be written in letters of 20mm height in white colour on black paint back ground.
93Advance Maintenance Free G.I. SAFE EARTHINGElectrodewith PIPE of not less than 50 mm outer dia) and two meterlength, The electrode should be ofgalvanised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X 6 mm7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg Backfill compoundto provide maximum contact between the electrode and Back Fill Compound. The earthing pitcover should be factory built (sizeTOP- 12 Inch, Bottom -11 Inch, Height 10.22 Inch ) made of heavy duty FRPcomplete including testing complete all as specified and directed by Engineer-in-Charge. Make : ASHLOK/INDELEC/JMV/TERCEL/TRUE POWER Note : Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE/AGE/user.Test results are to be written in letters of 20mm height in white colour on black paint back ground.
94Advance Maintenance Free G.I. SAFE EARTHINGElectrodewith PIPEof not less than 50 mm outer dia) and three meterlength, The electrode should be ofgalvinised (80 -100 micron) along with earth lead as galvanised steel strip of size 32 X 6 mm7.5 m . The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg Backfill compoundto provide maximum contact between the electrode and Back Fill Compound. The earthing pitcover should be factory built (sizeTOP- 12 Inch, Bottom -11 Inch, Height 10.22 Inch) made of heavy duty FRPcomplete including testing complete all as specified and directed by Engineer-in-Charge. Make : ASHLOK/INDELEC/JMV/TERCEL/TRUE POWER Note : Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE/ user.Test results are to be written in letters of 20mm height in white colour on black paint back ground.
95M&L for GI tubing light grade of size 40 mm bore for connecting to air termination rod / protection to GI strip complete tncluding Brackets for fixing complete all as specified and directed.
96M&L Cement Concrete 1:3:6, Type C2 (using 40mm Graded Stone Aggregate) as in Foundation of Poles, Stays,as in sub base in flooring, finished even etc. including Use and Waste of Formwork (if required), complete all as specified and as directed.