Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-05-2022 | PREBID MEETING QUERIES | Other | 20-05-2022 |
| Sl. No. | Item Description |
| 1 | Part A :- Civil WorkExcavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 2 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto1.50m)ByMechanical Means |
| 3 | Excavationforfoundationinhardmurumandbouldersincludingremovingtheexcavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed,dewatering,preparingthebedforthefoundationandnecessarybackfilling, ramming,wateringincludingshoringandstruttingetc.complete.(Liftupto1.5m.)By Mechanical Means |
| 4 | Conveying materials obtained from excavation upto a lead of 5 km including all leads,lifts,royalty etccomplete |
| 5 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)bytreatingthe bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifospersquaremeterofsurfaceareacovering10yearsguaranteeon bond paper. |
| 6 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosper square metre of surface area covering ten years guarantee on bond paper. |
| 7 | Providingsoling using80mm sizetrapmetalin15cm.layerincludingfilling voidswith Crushed sand/grit, ramming, watering etc. complete. |
| 8 | Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting etc. complete. |
| 9 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc. complete. |
| 10 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) |
| 11 | Providing and laying cement concrete flooring 50 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade |
| 12 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting,rougheningthemifspecialfinishistobeprovided,finishingunevenand honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered bygunnybag,plastic,tarpaulinetc.(Woodencenteringwillnotbeallowed.),withfully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
| 13 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailingoutwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 14 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground floor |
| 15 | First Floor |
| 16 | Second Floor |
| 17 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcementandstructuralsteel).withfullyautomaticmicroprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/concreteBatchmixplant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground floor |
| 18 | First Floor |
| 19 | Second Floor |
| 20 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)GROUND FLOOR |
| 21 | FIRST FLOOR |
| 22 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-20oftrap/quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsorasdirectedincludingsteelcentering, formwork,steelprops,laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Second Floor |
| 23 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate (Crushed sand VSI Grade) |
| 24 | Providing andlaying Castinsitu/ReadyMixcement concrete M-15oftrap/ granite/quartzite/gneissmetalforcoping to plinthorparapet,mouldedorchamferedasper drawingorasdirectedincludingsteelcentering,plywood/steelformworkcompacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) |
| 25 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-20oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem ifspecialfinishistobeprovidedandcuringcomplete.(Excludingreinforcementand structuralsteel).withfullyautomaticmicroprocessorbasedPLCwithSCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 26 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.GROUND FLOOR |
| 27 | FIRST FLOOR |
| 28 | SECOND FLOOR |
| 29 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. |
| 30 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete |
| 31 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placedat every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. |
| 32 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:4without neerufinish,toconcrete,bricksurface,inallpositionsincludingscaffoldingandcuring etc.complete. |
| 33 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 34 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. |
| 35 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 36 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding etc.complete. |
| 37 | First Floor |
| 38 | Second Floor |
| 39 | Providingandapplyingprimingcoatonconcrete/masonary/AsbestosCementplastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. |
| 40 | First Floor |
| 41 | Second Floor |
| 42 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old andnewsurfacesintwocoatsincludingscaffolding,preparingthesurface.(excludingthe primer coat)etc. complete |
| 43 | First Floor |
| 44 | Second Floor |
| 45 | Providing and applying two coats of exteriorweather shield paint of approved manufacture andofapprovedcolourtotheplasteredsurfacesincludingcleaning,preparingtheplaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etccomplNOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary |
| 46 | First Floor |
| 47 | Second Floor |
| 48 | Providing and applying epoxy paint primer with middle coat and top coat to superstructure including scaffolding etc complete. |
| 49 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete |
| 50 | Providing & fixing factory-made Single leaf 2 hour fire rated dooras per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer and Flush bolts complete. |
| 51 | Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator includingchromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. |
| 52 | Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steelfixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter |
| 53 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre asperdrawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete. |
| 54 | Providing andfixing in position(as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/Running metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight o.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With colour Anodising with box |
| 55 | a) Supplying and fixing in position Aluminium four track sliding windows with outer frame madefrom section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83Kilogramper metre andtop andside section of size 122x 31.75 mm weighing 1.15Kilogramper running metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6Kilogramper running metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainlesssteelmosquitonetinone (2/3 ofopening) panelfixed withnew neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. a) Colour anodized |
| 56 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/Running metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.AsperdetaileddrawingsandasdirectedbyEngineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box |
| 57 | Providing and fixing in position anodised (as per IS 1868/1982) Aluminium fixed staggered ( Z Type) Ventilator with aluminium rectangular pipe 63 mm x 38.10 mm x 1.22 mm at weight 0.650 Kilogram/Running metre, Aluminium angle of size 15 mm x 15 mm x 1 mm,aluminium channelof9mm sizes,S.S.mosquitonetof304Grade,4mm thick floatglass perdetailed drawing and as directed by Engineer in charge etc.complete. |
| 58 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. |
| 59 | Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and1.5mmthickattop,40mm diameterand1.5mm thickverticalsupportsspacedat1.5m centertocenterand8mmthicktoughenedglassincludingfabricating,fixtures,errecting, necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete |
| 60 | First Floor |
| 61 | SECOND FLOOR |
| 62 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of75mmdiameteretc.complete(PriorapprovalofsampleandbrandbyEx.Engineeris necessary before use) |
| 63 | Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mm of8to10mmthicknessandconfirmingIS.15622-2006(GroupBla)ofapprovedmake, shadeandpatternforflooringinrequiredpositionlaidonabedof1:4cementmorar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 64 | Providing and laying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approvedmake,shadeandpatternforflooringinrequiredpositionlaid onabedof1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 65 | Providingandfixingmachinecutmirrorpolished18mm to20mm thicktelephoneblack granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc.complete . Both side polish |
| 66 | First Floor |
| 67 | SECOND FLOOR |
| 68 | Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. |
| 69 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete |
| 70 | First Floor |
| 71 | SECOND FLOOR |
| 72 | Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 73 | Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. |
| 74 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. |
| 75 | First Floor |
| 76 | SECOND FLOOR |
| 77 | Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm size as per detaileddrawing including vertical bothside polishedkadappah stone 25 to 30 mm thick supports with kadappahtop 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two verticalgranitesupports15cmheightandtopgraniteof75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) |
| 78 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete. |
| 79 | First Floor |
| 80 | SECOND FLOOR |
| 81 | ProvidingandfixingheavydutyinterlockingconcreteColouredpavingblocksof80mm thickness of having a strength of 300 Kilogram/Sq.cm. of approvedquality andshape ona bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete |
| 82 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.Cmembersandbrickwork,ofapprovedqualityincludingfixing meshinpositionby necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. |
| 83 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providingandlaying12mmbeddingincementmortor1:3onverginconcreteslabwith waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba ofrequired thickness in cm 1:5withwaterproofing compound1Kilogram/bag ofcement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete. |
| 84 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. |
| 85 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 86 | Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 87 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 88 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 89 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.GROUND FLOOR |
| 90 | FIRSTFLOOR |
| 91 | Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut completeGROUND FLOOR |
| 92 | FIRST FLOOR |
| 93 | Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut completeGROUND FLOOR |
| 94 | FIRST FLOOR |
| 95 | Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.GROUND FLOOR |
| 96 | FIRST FLOOR |
| 97 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.GROUND FLOOR |
| 98 | FIRST FLOOR |
| 99 | Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.GROUND FLOOR |
| 100 | FIRST FLOOR |
| 101 | Providing and fixing 15 mm dia. screw down bib/ stop tap ofbrass including necessary socket union nut complete.GROUND FLOOR |
| 102 | FIRST FLOOR |
| 103 | Providing and fixing 20 mm dia. screw down bib/ stop tap ofbrass including necessary socket union nut complete.GROUND FLOOR |
| 104 | FIRST FLOOR |
| 105 | Providingandfixingstainlesssteelsinkofsize600x510x200mm incluidngcoupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 106 | ProvidingandfixingwhiteglazedearthenwareWashHandBasinof55cm.x40cm.size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. |
| 107 | Providing and fixing coloured glazed earthenware Wash Hand Basin of 55cm x 40 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. |
| 108 | Providing and fixing 10 cm PVC nahani trap with grating etc.complete |
| 109 | Providing and fixing orissa type colour glazed earthenware 625 x 450 mm. w.c. pan including trap, C.I. soil and vent pipe upto the out side face of wall including 100 mm. dia. C.I. plug, bend,15mm.thick10litrePVCflushingcisternwithallnecessarypipeconnectionetc. complete. |
| 110 | Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jetandfittingincludingcuttingandmakinggoodtothewallsandfloorstestingetc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) |
| 111 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 112 | Providing , laying and fixing ,jointingEco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. |
| 113 | Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such abends,tees,coupler,etc,jointingwith rubberlubricantincludingnecessary excavation, trench refilling with selective excavated materialetc. complete. |
| 114 | Providing and fixing H.D.P container one piece moulded water tank made out oflowdensitypolythylerandbuiltcorrugationincludingofdeliveryuptodestination hoisting andfixing of accessories such as inlet, outlet overflow of alltanks capacityabove 1000 to 20,000 litres |
| 115 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. |
| 116 | Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mmdia. nickel plated towel rod etc. complete. |
| 117 | Providing andfixing in positionUPVC ultra violet stabilized110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete |
| 118 | ProvidingandfixingP.V.C.Rainwaterpipesof160mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.GROUND FLOOR |
| 119 | FIRST FLOOR |
| 120 | SECOND FLOOR |
| 121 | Providing and fixing 110 mm dia stabiliser pipe/ P.V.C. soilvent/waste pipe and with necessary fixtures and fitting such asbends, tees, single junctions, slotted vent, clamps etc. completeGROUND FLOOR |
| 122 | FIRST FLOOR |
| 123 | SECOND FLOOR |
| 124 | Providing & constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover 75 kg with frame fixed in cement concrete. |
| 125 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32mm dia. P.V.C flush pipe withfittings andflushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall |
| 126 | Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. |
| 127 | Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 128 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 129 | Providing soak pit of size 120cm x 120cm x 120cm includingexcavating and filling with brickbats. |
| 130 | Providngandfixinginpositionanodisedextrudedaluminumpartitions,partlyglazedand partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixedwithaluminum glassclips12mm x12mm andrubbercushioningbeadingtoglass partitions as per approved drawing etc. compete |
| 131 | Providingandfixingfalseceilingwitheco-friendlylight-weightcalciumsilicatetilesof spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thickdensifiedmicrolookedgeand100%humidityresistanceincombustibleasperBS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal levelsuspendedgridofsize600x600mmmadefromhotdippedG.I.steelsectionsion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, mainT runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middleofthefirstcrossedTineachpaneltoformgridof1200mmx600mmrestingon peripherywallProfilewallsection19mm (7+7)x19mmx0.40thicknessesandlayingfalse ceiling forservices like diffusersgrillsincluding cutting,making opening forlightfittings, fixtures,,smoke detectorsetc.,whereverrequired. MainT runnerssuspendedfrom ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mmdiaand 50mmlongdash fastener,4mmdiaG.I. adjustablerods with powder- coated/goodqualityG.I.leveladjustmentclipsof35x35x0.8mmspaced@1200,center-to-center along main T all complete at all heights as per the specifications, drawings and as per |
| 132 | FIRST FLOOR |
| 133 | SECOND FLOOR |
| 134 | Providingandfixingblackkadappastoneasshelves25mm.thickmachinepolished, extendingthepolishupto20cmwidthonlowerside,roundingcorners,layinginposition jointing with bedding cement mortar 1:4 proportion curing etc etc. complete. |
| 135 | Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12mmwithrollerwheelsconfirmingtogradeF.G.150fittedwithsnapheadedrivetsof minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clearspaceof150mmbetweentwosetsofcrossingswithholdfasts,stoppers,spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). |
| 136 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting,erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 137 | Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt.totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength,metallichotdipcoatedwithAluminium-Zincalloy(55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshallhaveatotalcoatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbedesignedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) |
| 138 | Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 120 cm widewithteakwoodplanking20mmthickincludingtwocoatsofcoal-tarringtheupper surface of plank etc. complete. (excluding painting to underside of plank). |
| 139 | Providing andconstructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raftinB.C.soilareaincludingcostofreinforcement,1:2:4cementconcretechannelshalf round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover medium duty 100Kilogrametc. complete. |
| 140 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 Kilogram) |
| 141 | Providing andfixing 25mm diameterwatermeterwithnon-returnvalve includingstrainer, sockets/unionnutandincludingwatermeterboxmakinglockingarrangementandlock. [Without chamber]. |
| 142 | Providing andfixing 50mm diameterwatermeterwithnon-returnvalve includingstrainer,sockets/unionnutandincludingwatermeterboxmakinglockingarrangementandlock. [without chamber] |
| 143 | Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 6524-1983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm .GROUND FLOOR |
| 144 | FIRST FLOOR |
| 145 | Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35mm thick style and rail with 25 mm thick panels with openable fan light as per detaileddrawings. Excluding the door frame 60mm x 100mm stainless steel fixtures andfasteningandfinishingthewoodworkwithoilpainting3coats.(Excludingthedoor frame). |
| 146 | Providingandfixing90cmx60cm Graniteplateengraving10cm.heightletter,figures including painting the lefters/figures with approved colour and shade completeGROUND FLOOR |
| 147 | FIRST FLOOR |
| 148 | SECOND FLOOR |
| 149 | Providing fine cement finish 1.5mm thick over green plster surface including scaffolding curing its complete |
| 150 | Providing & fixing heat insulation by wrapping the pipes with glass wool/asbestos fibre rope or tape/videoflex 25 mm as directed by Engineer in charge. |
| 151 | Providing and fixing in position aluminium composite pannels 4 mm thick and required size of building made out cladding for walls of approved colour and shade on strutiral frame work 65x65x6 mm thick aluminium frame work including fixtures of SS screws ,nuts, bolts and scaffolding , MS angles cleate support to frame work etc. complete. As directed by Engineer in charge. ( Approved item of cancer hospital building Aurangabad ) |
| 152 | Part B :- Testing Charges & RoyaltyCarrying out various quality control tests as per frequency and as directed by Engineer-in-charge.Job Mix Design for M20 with tests of basicmaterials |
| 153 | Cement |
| 154 | Reinforcing steela) Upto 16 mm dia (set of 3 bars ) |
| 155 | b) above 16 mm dia (set of 3 bars ) |
| 156 | Concrete Cubes (set of three cubes ) |
| 157 | Bricks (set of 5 bricks ) |
| 158 | Ceramic Tiles (set of 6 tiles ) |
| 159 | Testing of murum ,PI |
| 160 | Testing of Fine agreegates,FM ,Silt factor |
| 161 | basic tests on agreegates (W.A.,Sp Gr.,Impact,crushing,Sieve Ana,Abrasion,Flakiness |
| 162 | Royalty charges for sand etc |
| 163 | Royalty charges for murum,soling etc |
| 164 | Part C :- DemolitionRemovingandresettingMangaloretilesfromroofincludingrefixingloosebattensetc. complete. |
| 165 | Removing King Post truss from roof and stacking the materials as directed with all leads andlifts etc. complets |
| 166 | DismantlingflatwoodenorA.C.Sheetceilingwithframeworkincludingstackingthe materials as directed with all leads, lifts etc. complete. |
| 167 | Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. complete. |
| 168 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 169 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. |
| 170 | Removinglimeorleancementconcreteincludingstackingthespoilsasdirectedwithall leads, lifts etc, complete. |
| 171 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. |
| 172 | FF |
| 173 | SF |
| 174 | Dismantling the R.C.C. work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed. |
| 175 | RemovingW.C.pansincludingdisconnectingthesanitaryandwatersupplyconnections, removing and breaking flooring and bed con-crete around pan removingthe same carefully and stackingtheserviceablematerialsasadn wheredirected includingthrowingthe unserviceablemateriaslsoutsideetc.carefullyandthrowingouttherefusaloutsideetc. complete. |
| 176 | Removing mudplaster including disposing of the spoils as directed with all leads, lifts etc, complete. |
| 177 | FF |
| 178 | SF |
| 179 | Removing brickbatcoba including stackingthe spoilsasdirectedwithallleads,liftsetc, complete. |
| 180 | Removing purlins from roof including stackingas directed with all leads , lifts etc. complete. |
| 181 | Removingraftersfromroofincludingthematerials asdirectedwithallleads,liftsetc. complete. |
| 182 | Removingbattensfromroofandstackingthemasdirectedwithallleadsandliftsetc. complete. |
| 183 | Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. For 5 km |
| 184 | Part D :- Electrical WorkSupplying and erecting UPVC reinforcedflexible conduit 20 mm in dia. conforming toI.S. with requirednumberof couplings, PVC bushes, check nuts etc. complete. |
| 185 | Supplying and erecting UPVC reinforcedflexible conduit 25 mm in dia. conforming toI.S. with requirednumberof couplings, PVC bushes, check nuts etc. complete. |
| 186 | Supplying and erecting PVC trunking (PVC casing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. |
| 187 | Supplying and erecting PVC trunking (PVC casing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. |
| 188 | Supplying anderectingPVCboxtrunking ofsize50x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX. |
| 189 | Supplying & erecting mains with 2x1.5 sq.mmF.R copperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 190 | Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 191 | Supplying & erecting mains with 2x1.5 sq.mmF.R copperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 192 | Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 193 | Supplying & erecting mains with 2x10 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 194 | Supplying & erecting mains with 4x16 sq.mm F.Rcopper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 195 | Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWCONSIDER HALF QTY FOR 1 X 4 WIRE |
| 196 | Supplying & installing UTP networking cat-6 cable with rodent proof jacket suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC |
| 197 | Supplying,erecting, testing and commissioning of 1 sq mm speaker wire complete. |
| 198 | Supplying,erecting, testing and commissioning of 1.5 sq mm speaker wire complete. |
| 199 | Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 25 mtr cord length with male/female 19pin HDMI connectors as per requirements complete. |
| 200 | Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 5 mtr cord length with male/female 19pin HDMI connectors as per requirements complete. |
| 201 | Supplying & installing single mode fibre patch cord 3 m – duplex complete. |
| 202 | Supplying & installing single mode fibre adapter with plate - 6 port complete. |
| 203 | Supplying & installing single mode simplex pigtail complete. |
| 204 | Supplying and fixing IP66 enclosure for fibre splicing as per specification complete. |
| 205 | Supplying & erecting on line UPSpure sine wave of 3 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup,as per specification no. AP-UPS |
| 206 | Supplying and erecting One/Two way pianotypeswitch 6A./bell push erected on filled polypropyleneboard or double polished wooden board/ folded or screwed boardwith top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with S M screws and duly connected. |
| 207 | Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 208 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 209 | Supplying and erecting ISI mark modular type (two modules) electronic dimmer 600/650W, duly erected on provided plate and box with wiring connections complete. |
| 210 | Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 211 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 212 | Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 213 | Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box. |
| 214 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 modules duly erected. |
| 215 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected. |
| 216 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 217 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 218 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 219 | Supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, T8 LED tube light (excluding tube light). |
| 220 | Supplying and erectingLED square / circular 5 to 8W down lighter having pressure die-cast aluminium housing,opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. |
| 221 | Supplying and erectingLED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing,opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. |
| 222 | Supplying and erectingLED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing,opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. |
| 223 | Supplying and erecting square shaped CRCA /die-cast aluminium powder coatedhousing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete. |
| 224 | Supplyinganderecting 2lightfancywallbracketwitharm fabricatedfrombrass duly lacquered with suitable holder andfancy glass shade duly wired erected on wall with suitable size ofpolished wooden / laminated board. |
| 225 | Supplying&erecting suspensiontype decorative pendent fitting single lightwith anodized aluminium / powder coatedMS rod up to 1 m length and canopy on top provided with decorative glasssheddulywiredwithtwocoreflatwiresuitablelampholder complete. |
| 226 | Supplying and erecting LED Mirror Light with integrated driver including 14W to 18W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete. |
| 227 | Supplying anderecting LED street light fitting 12 to 18 W, with PF >0.95 class IP65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG-ODF/FLS-2. |
| 228 | Supplying anderectingLED street light fitting suitable for 20 to 25W, with PF >0.95class IP65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG-ODF/FLS-2. |
| 229 | Supplying and erecting street light Wall bracket made from 25 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB |
| 230 | Supplying and erecting street light Wall bracket made from 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB |
| 231 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner. |
| 232 | Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF |
| 233 | Supplying, erecting & marking FPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB |
| 234 | Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB |
| 235 | Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB |
| 236 | Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB |
| 237 | Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB |
| 238 | Providing & erecting 3 Pole MCCB upto 100A, 415V,with short circuitrating 25 kA (Ics=100% of Icu ),adjustablethermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frameas per specification no. SW-SWR/MCCB |
| 239 | Providing & erecting 3 Pole MCCB of 250A,415V capacity with short circuit rating 36 kA (Ics=100% of Icu) adjustablethermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frameas per specification no. SW-SWR/MCCB |
| 240 | Supplying&erectingtriplepoleand neutral distribution board (TPNDB) with door surface/ flushmounted suitable for3 pole MCCB as incomer & outgoingSP MCB (24 poles) or TP MCB of 8 ways (24 poles) , on iron/ GI frame. (vertical busbar type)as per specification no. SW-SWR/MCBDB1 |
| 241 | Supplying&erectingtriplepoleand neutral distribution board (TPNDB) with door surface/ flushmounted suitable for 3 pole MCCB as incomer & outgoingSP MCB (36 poles) or TP MCB of 12 ways (36 poles) on iron/ GI frame. (vertical busbar type)as per specification no. SW-SWR/MCBDB1 |
| 242 | Supplying and erecting SS enclosure for MCCB suitable for 125A to 200A MCCB complete. |
| 243 | Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete. |
| 244 | Supplying and erecting four pole metal clad ON LOAD change over switch 415V,320Aerectedon angle iron /GI frame complete. |
| 245 | Supplyinganderectingiron, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.Fabrication work for cubical, box, cover, platform for electrical panel room and fire fighting related electrical instrument room |
| 246 | Providing & erecting Hot dippedgalvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. |
| 247 | Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP |
| 248 | Supplying and erecting bus bar chamber triple pole with neutral with four copper bars, 500V 200A complete as per specification no. CP-BB |
| 249 | Supplying and erecting of any size electrolyte copper patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% copper purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB |
| 250 | Supplying evaporative air cooler (desert cooler) with galvanised steel body 230/250 Volts, 50 cycles, normalcooling capacity of 80 cu.m per minute with 18\" exhaustfan, minimum 75 to 80 litre water capacity tank complete.specification no. APWCR/ DAC |
| 251 | Providing replacement of base trayof water cooler of any capacity. Note:-1) If cost of repairs of any appliances is more than 50% of the cost of new unit, replacement of same shallbe proposed. 2) dismantled material to be retained by contractor. |
| 252 | Part E :- FurnitureCORPORATE TABLE 2.4X.6X.75 |
| 253 | CORPORATE TABLE 1.80X0.60X0.75 |
| 254 | main Dais TABLE: 6.3X.75X.75/.90 |
| 255 | AC BOX 1.80X1.80 |
| 256 | STAGE TOP CEILING 5.40X7.20 |
| 257 | wall ply moulding |
| 258 | Stage back panelling |
| 259 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. complete. |
| 260 | 19 mm mica high pressurecommercial plywood confirming to I.S. 2046 (regular type) |
| 261 | GAZEBO : Cast Iron Gazebo-Code No.-DGZ-003 (12’ x 12’) Providing and fixingCast Iron Gazebo- code no. DGZ-003, shown in the enclosed drawing; Hexagonal gazebo of 14’center height. Interconnected with Cast Iron Arches & Grill’s and the roof covered with Fiberglass roof (Corrugated Sheets) on the structure made out in M.S. Pipes.The specification of Gazebo includes the pillars i.e. to be cast using silicon castings molds the pillars has the base of 10” diagonal, the length of the pillar is 2.5 mtr.The details of the various portion are given in the enclosed drawing along with foundation detail.The Gazebo shall be painted by attractive antique looking paint of copper/gold colors with black base to give it a rich antique look with roof of Fiberglass roof (Corrugated Sheets). This color shall be of polyurethane type of paint and should make the gazebo look attractive.The Gazebo shall be exactly similar looking as shown in the enclosed drawing/picture. It shall have all similar features as shown in the enclosed drawing/picture.The weight of the Gazebo Approximate- 1100.0 Kg. With a tolerance of 3%. |
| 262 | Part F :- Fire FightingSupplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main single stage pump, of 2400 LPM at 76 m head centrifugal type, 75 HP (55 kW) 3 phase, 415 volt, 50Hz or of suitable HP complete as per specification no. FF-MFP/SSC |
| 263 | Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 56 m head, 15 HP (11 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP |
| 264 | Supplying, installing, testing and commissioning with perfect aligning, proper levelling of booster pump of 900 LPM at 40 m Head, 12.5 HP (10 KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/BP |
| 265 | Supplying & erecting automatic control panel for 3 Ph, 415 volt, a.c. Submersible/centrifugal pump set upto 20 HP consisting of Star Delta starter having relay range 13-21Amp,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 266 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 267 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 268 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 269 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 270 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 271 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 200 mm dia with necessary fittings complete as per specification no. FF-PP |
| 272 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system. |
| 273 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 274 | Supplying and erecting cast iron foot valve ball type/flap type of size 100 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV |
| 275 | Supplying and erecting cast iron foot valve ball type/flap type of size 150 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV |
| 276 | Supplying and erecting 100 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS |
| 277 | Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV |
| 278 | Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV |
| 279 | Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV |
| 280 | Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV |
| 281 | Supplying and erecting cast iron double flange NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV |
| 282 | Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV |
| 283 | Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV |
| 284 | Supplying & erecting gun metal gate valve of size 25 mm dia complete as per specification no. FF-VL/GV |
| 285 | Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 286 | Supplying, erecting and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled /liquid cooled multi-cylinder diesel engine developing suitableBHP at 1500 rpm with 10% overload for 1 hour in 12 hours,along with standard accessories, self-excited, self-regulated,screen protected alternator with static excitation systemrunning at 1500 RPM as per IS 4722-2001 with voltageregulation +/- 5 %. Both the engine and alternator directcoupled on a common fabricated steel base frame andmounted on anti-vibrating pads with standard control panelcomprising meters, switchgears, indicators connected withsuitable wires/cables, the complete set enclosed in compositeAcoustic enclosure as fully assembled integral unit made of 16SWG CRCA Sheet, sound absorbing material to restrict soundlevel upto 75 dB at 1.0 m, provided with first filling of oil,diesel, etc and obtaining necessary approval fromElectrical Inspectoras per specification no. GEN-DG |
| 287 | Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable fordieselgenerating set of above 200 kVA upto 250 kVA capacitySingle/Three phase, 230/415 Volts, 50Hz A.C. with allstandard features, safeties etc as per specification no. GENAMF. |
| 288 | Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV |
| 289 | Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 290 | Supplying & erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ |
| 291 | Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FBC |
| 292 | Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC |
| 293 | Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT |
| 294 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 295 | Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/ PG |
| 296 | Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 297 | Supplying and erecting one no. brass orifice plate having 6 mm. thickness, 140 mm outer dia and required/proper diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 298 | Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour. |
| 299 | Supplying, erecting, testing and commissioning of 15 mm (½\") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR |
| 300 | Supplying, erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 100 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes |
| 301 | Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete. |
| 302 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete. |
| 303 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete. |
| 304 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 305 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 306 | Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 307 | Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 308 | Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 309 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/ CU |
| 310 | Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. |
| 311 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 312 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. |
| 313 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 314 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 315 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 316 | Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 317 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 318 | Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). |
| 319 | Fire Detection SystemSupplying, installing, testing and commissioning heat detector complete on box as per specification no. FFFAS/ HD |
| 320 | Supplying, installing, testing and commissioning optical type smoke detector complete on box as per specification no. FFFAS/ SD |
| 321 | Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 322 | Supplying, installing, testing and commissioning hooters with CRCA enclosure complete as per specification no. FF-FAAS/HTR |
| 323 | Supplying, installing, testing and commissioning remote response indicators complete as per specification no. FF-FAAS/RRI |
| 324 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/ CU |
| 325 | Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories complete as per specification no. FF-FAAS/FACP (Total 8 Zone panel) (17588+((0.25*17588)*6)=43970) |
| 326 | Part G :- HVACSupplying, erecting, testing and commissioning 28 HP, VRF/ VRV air conditioning system, out door unit (ODU)complying type-IV OEM standards working on HFCfree refrigerant R410A or other required/suitable greenequivalent refrigerant, for cooling capacity delivering 100% at47 deg. celcius and non stop cooling even at 56 deg. celsiusand coefficient of performance (COP) 3.00 to 4.00, modulartype horizontal/vertical hot air discharge suitable for totalpiping length upto 1000 metre operation in cooling modewith inverter based VRF/VRV technology microprocessorbased control compressor starter/control panel completewith scroll compressor, air cooled anti corrosive coppercondenser coil of suitable shape for increasing maximumheat transfer area, built in oil separator, accumulator and oilreceiver, copper tube aluminium fin air cooled condenser,condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3phase power supply, internal copper refrigerant piping,internal wiring and first charge of refrigerant, etc. all housedin powder coated weather proof cabinet on provided angleiron frame or suitable foundation connected to the system inapproved manner complete. |
| 327 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 4.1TR ( 1218 cfm ) to 5.0TR ( 1624 cfm ) havingEER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete. |
| 328 | Supply, installation, testing and commissioning air curtain of 6 feet width having air throw velocity of 21 m/sec, lownoise level up to 38 to 46 dB suitable for door height upto 9 feet, working on 1ph, 230 V, 50Hz, A.C. supply. |
| 329 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 330 | Supplying, erecting, testing and commissioning centralised programmable remote contol panel (HMI) touchmanager controls minimum 16 system of minimum 64 ODU\"s can be controlled and up to 992 IDU\"s can beindividually mounted and controlled indoor units having minimum 200 mm size colour LCD touch panel, yearlyschedule, power proportional distribution function, temperature limitation, history function complete erected onwall with an arrangement to integrate with provided fire alarm system. |
| 331 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc.with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system. |
| 332 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mmdia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquidmain line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 333 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mmdia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquidmain line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 334 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mmdia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquidmain line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 335 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mmdia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquidmain line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 336 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mmdia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquidmain line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 337 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mmdia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquidmain line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 338 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mmdia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquidmain line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 339 | Supplying and erecting PVC insulated PVC round sheathed 1.5sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV |
| 340 | Supplying, erecting & terminating XLPE armoured cable1100 V. 4 core 4 sq. mm. copper conductor continuous5.48 sq. mm. (12 SWG) G.I. earth wire complete erected withglands & lugs, on wall/ trusses/ pole or laid in providedtrench/ pipe as per specification no. CB-LT/CU |
| 341 | Supplying, erecting & terminating XLPE armoured cable1100 V. 4 core 6 sq. mm. copper conductor continuous5.48 sq. mm. (12 SWG) G.I. earth wire complete erected withglands & lugs, on wall/ trusses/ pole or laid in providedtrench/ pipe as per specification no. CB-LT/CU |
| 342 | Supplying, erecting & terminating XLPE armoured cable1100 V. 4 core 10 sq. mm. copper conductor continuous5.48 sq. mm. (12 SWG) G.I. earth wire complete erected withglands & lugs, on wall/ trusses/ pole or laid in providedtrench/ pipe as per specification no. CB-LT/CU |
| 343 | Providing pipe type earthing with 40mm. dia. G.l. pipe or20 mm dia. G.l. Rod complete with all materials as perspecification no. EA-EP |
| 344 | Supplying, erecting & terminating XLPE armoured cable1100 V. 2 core 4 sq. mm. aluminium conductor withcontinuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 345 | Supplying, erecting & terminating XLPE armoured cable1100 V. 2 core 6 sq. mm. aluminium conductor withcontinuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 346 | Supplying, erecting & terminating XLPE armoured cable1100 V. 2 core 10 sq. mm. aluminium conductor withcontinuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 347 | Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 2 TR capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete with Refrigerants R410 A/R32 and copper condenser at position. specification no. AP-AC/SAC |
| 348 | Part H :- Sound System/Video Wall1.MICROPHONEa)supply installation testing and commisioning of Gooseneck Microphone without base and mute switch - 23” Electret condenser microphone with Cardioid Polar Pattern.Phantom Power Adaptor Included which will eliminate all cellular frequencies (GSM/2G, 3G, G & 5G).Cardioid polar pattern with tailored response for speech. Frequency Response : Minimum - 50 Hz, Maximum - 18000 Hz Sensitivity - 40dB +/- 3dB @ 1KHz (0dB =1V/Pa)Output Impedance : Maximum 200 Ob)supply installation testing and commisioning ofUHF Wireless Handheld Microphone Set & Antena Distribution System with Antena for 4 Wireless Handheld Microphones -Auto Frequency Selection to Locate a clear channel instantly.Wireless System: Up to 24-bit, 48 KHz, digital audio RF technology.Frequency Response : Minimum - 60 Hz, Maximum - 15kHZFrequency and power lockout avoids accidental changing of settings.Encryption: 256 bit key (AES) always-on, laboratory-verified | NSA FIPS 197 standard.With standard rack mounting hardware. 4 Bay Docking Station Included.Antena Distribution System - 130 Degree reception pattern.Gain: Provides 15dB of RF gain (915MHz) |
| 349 | 2.AUDIO REINFORCEMENTa)supply installation testing and commisioning of Main FOH Speaker -Transducers - 16 x 2.75”, 200 Watts RMS. Frequency Response - 130Hz - 23kHz.Sensitivity (2.83v @ 1m) - 94dB SPLPeak SPL - 123dB Coverage - Horizontal 140 Degree x Vertical 20 Degreeb)supply installation testing and commisioning ofDelay Speaker -8 x 2.75” Transducers, 200 Watts RMS Frequency Response - 150Hz - 23kHz. Sensitivity (2.83v @ 1m) - 94dB SPL Peak SPL - 119dB Coverage - Horizontal 140 Degree x Vertical 20 Degreec)supply installation testing and commisioning ofCeiling Speaker for Mayor, Officers and Balcony - Woofer - 6.5” x Tweeter - 1.567”, 8 Ohms 60Watts.Frequency Response - 60Hz - 20kHz. With Back Can |
| 350 | 3.VIDEO SYSTEM & CONTROL UNITa)supply installation testing and commisioning ofDisplay - 2.5P Indoor LED Wall -115” - Aspect Ratio - 16:9,Supports 1080P Full HD, 4K Resolution. Brightness (cd/m2) - Min 600, Frame Rate - 60 Hz/sec, Refresh Rate - 1920 Hz/sec, Optimum Viewing Angle - Minimum H160 Degree / V160 Degree,Should come with standard wall mount bracket.b)supply installation testing and commisioning of PTZ Camera -FHD Video Output Up to 1080/60p via USB 3.0 and HDMI,1/2.7”HD CMOS sensors.Optical Zoom: Up to 12X, Full HD 1080p signal output format with a high frame rate of 60 fps.HDMI, and USB 3.0 synchronous video outputsWith Ceiling mounting Kit |
| 351 | 4.E- PODIUM, CABLES & INTALLATIONa)supply installation testing and commisioning ofE-PODIUM -Suitable to the hall interior, 24” Touchscreen, I5 CPU, and A/V Interfaceb)supply installation testing and commisioning ofWireless Presentation Solution - Supports Windows™ and Mac™ laptops, Chromebooks™, iOS™ and Android™ mobile operating systems High–quality 4K@30Hz video streaming 6 participants can present simultaneously.2.4GHz/5GHz Wi–Fi and MIMO antennas establish and maintain a fast and reliable connection.c)consider all the necessary cables and connectors |
| 352 | Part I :- AccousticProviding & Fixing in position, Acoustical Panelling made fromFabric wrapped Compressed polyester fibre nonwoven 9 mmpanels on, 50 x 50 mm sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh on wall side, includingcostofrequiredCut-Outs,decorativemouldings/finishing-items/paint&Scaffolding,asper Architectural&AcousticalDesign &Instructions&Completeinallaspects.includingallmaterialslabour,finishing etc complete |
| 353 | Providing & Fixing in position, Acoustical Panelling made from Wood-wool board 20mmon, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsmsyntheticwool50mmthickwithchickenmeshonwallside,includingcostofrequiredCut-Outs, decorativemouldings/finishing-items/paint&Scaffolding,asperArchitectural&AcousticalDesign& Instructions & Complete in all aspects. including all materials labour,finishing etc complete |
| 354 | Providing & Fixing in position, Acoustical Panelling made from Gypsum plain 12mm panels on, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsmsyntheticwool50mmthickwithchickenmeshonwallside,includingcostofrequiredCut-Outs, decorativemouldings/finishing-items/paint&Scaffolding,asperArchitectural&AcousticalDesign& Instructions & Complete in all aspects.including all materials labour,finishing etc complete |
| 355 | Providing & Fixing in position, Acoustical Panelling made from 12mm wp Ply wood & 1.5mm laminateon, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs,decorativemouldings/finishing-items/paint&Scaffolding,asperArchitectural&Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete |
| 356 | Providing & Fixing in positionAcoustical Doors along with150 x 150mm teak woodframe, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges(Geze/Dormaoreq.) 4noeachleaf, withDoor-closer(Dorma/Gezeoreq.) includingcostof required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural&AcousticalDesign&Instructions&Completeinallaspects.includingallmaterialslabour,finishing etc complete |
| 357 | Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 & 18mm Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 at 600mm c to c on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish etc., as per Architectural & Acoustical Design & Instructions & Complete in all aspects..including all materials labour,finishing etccomplete |
| 358 | Providing & Fixing in position, Acoustical Ceiling made from Gypsum Plain Panels on approved heavy dutyG.I. frame ceiling channels at 450 c to c, & intermediate channels not more than 1200 c to c, along with ply woodformssuspendedwithHangers from Roof, in front of 1000 Gsm syntheticwool 50mm thick,with Paint,includingcostofrequiredCut-Outs,decorativemouldings/finishing-items&Scaffolding,asper Architectural&AcousticalDesign &Instructions&Completeinallaspects.includingallmaterials labour,finishing etc complete |
| 359 | Providing & Fixing in position, Acoustical Ceiling made from Compressed polyester fibre nonwoven 9mm panels onapprovedheavydutyGIframe300mmctoc&intermediatechannelsat1200mmctoc, suspendedwithHangersfrom Roof,includingcostofrequiredCut-Outs,decorative mouldings/finishing- items&Scaffolding,asperArchitectural&AcousticalDesign&Instructions&Completeinallaspects including all materials labour,finishing etc complete |
| 360 | Providing & Fixing in position, Acoustical Ceiling made from Rigitone 8/18 perforated panels on approved heavy duty G.I. frame, ceiling channels at 300 c to c, & intermediate channelsnot more than1200c to c, suspended with Hangers from Roof, in front of 1000 Gsm synthetic wool 50 mm thick, with Paint, including costofrequiredCut-Outs,decorativemouldings/finishing-items&Scaffolding,asperArchitectural& AcousticalDesign&Instructions&Completeinallaspectsincludingallmaterialslabour,finishingetccomplete |
| 361 | Providing & Fixing in position, Acoustical Panelling made from 12mm thick Agro wood strips of 50, 75 7 100 mm width on 50 x 50 mm Sal-wood frame of 600 x 600 c to c having supports from wall of required length,infrontof1000gsm syntheticwool50mm thickwithapprovedcolouredfabriconstripsside& chickenmeshonwallside,includingcostofrequiredCut-Outs,decorativemouldings/finishing-items/ Melamine Polish & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete |
| 362 | Providing & Fixing in position, Fabric wrapped Compressed polyester fibre nonwoven 9mmpanels above the woodwoolboardpanelling orexisting salwoodframe,using adhesive,asperArchitectural&Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete |
| 363 | Providing & Fixing in position,Partition made from 12mm thick Gypsum from both sides on 50 x 50 mm Sal-wood frame of 600 x 600 c to c, havingof 800 gsm synthetic wool 50 mm thick in between, including costofrequiredCut-Outs&Scaffolding,asperArchitectural&AcousticalDesign&Instructions& Complete in all aspects including all materials labour,finishing etc complete |
| 364 | Providing & Fixing in position, Carpetmore than 800+ gsm, made with100% stain proof fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in allaspectsincluding all materials labour,finishing etc complete |
| 365 | Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminatepanels above the fabricated frame on one side , as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including allmaterials labour,finishing etc complete |
| 366 | Providing&Fixinginposition,MSfabricationworkusingangles,sqrtubes,cchannelsetc forvariouspartitionframe as per Design & Instructions & Complete in all aspects . includingall materials labour,finishing etc complete |
| 367 | Providing & fixing in position, heavy duty fully upholstered Auditorium chairs 520 mm c to c tip-up type. Height of back should be less than 1030 mm with plastic protective cover on back and bottom having teak wood handles. Back to back distance is 1000mm. The auditorium chairs should be of following specifications1. Powder Coated Heavy duty MS Stand.2. Individually moulded , ergonomically designedseat and back cushions. 3.Moulded Polyurethane Foam cushion. PU foamdensity 48– 52 Kilograms/cu.mtr4. Moulded Polyurethane Foam manufactured in certified ISO 9001 facilityto ensure consistency in density for longevity.5.Upholstered in Foam laminated stretch sandwich Fabric for clean finish and soft comfortable feel as per the colour & pattern selected by the client. 6.Seat and Back should have moulded synthetic protective cover. 7. Wooden or PU armrest65mm x 20mm- 330mmlong . 8.Mounted using Anchor fasteners. |
| 368 | ProvidingandFixingRollarBlindsAMIMakeorapprovedmake&shadeof38mmroundAluminium channelwithBlackout fabric& telting withchain(Ball) system withallnecessary fixturesandfitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) |
| 369 | ProvidingandFixingVerticalBlindsofapprovedMakeandshadeof100mm regularfabricwithpowder coatedaluminiumchannelwithteltingPVCchain&bottomweightplatewithallnecessaryfixturesand fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) |
| 370 | Providing&ArrangemntofHighBack,SynchronizedMechanismwithMultipleLocking,Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Basewith Leatherite Upholstery |
| 371 | Providing&ArrangemntofHighBackChair-TILTMECHANISMWITHMULTILOCKING,HIGHDENSITYCUSHIONONSEATCOMPOSITELEATHERWITHMETALLICSILVERFINISHBASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. |
| 372 | Providing & Arrangemnt of MId Back, Normal SyncroMechanism , Fixed Armrest , Gaslift for Seat heightadjustment, Standard 5-prong/Nylon Base with Leather Upholstery |
| 373 | Sofa Set 3+1+1Providing & fixingSofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms)Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat |
| 374 | Part J :- CCTVCCTV Supplying, installing, testing and commissioning 32 Channel Network Video Recorder(DHI-NVR4232-4KS2/L)4 MEGA PIXEL FULL HIGH DEGINATIONDOME / Bullet Night Vision ColourCCTV Camera (DH-IPC-HDBW1431EP-S4) HARD DISK 8 TB POE SWITCH 16 PORT DH-PFS3228- 24GT-240 RJ 45 4*4 BOX RACK 6 UCAT 6 CABEL PER MTR 32\" FULL HD LED TVHDMI CABEL 15 MTR 24\" LED MONITOR etc. Completed |