Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-04-2022 | Corrigendum | Other | 12-05-2022 |
| Sl. No. | Item Description |
| 1 | Carriage of Materialsby mechanical transport including loading, unloading and stacking ::Earth (Rate for lead 1km.) |
| 2 | Earth work in excavation in foundation, trenches etc. including, clay, black cotton soil, kankar, etc. dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, Depth upto 1.5 m |
| 3 | Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer includingramming and watering and consolidation with lead up to 50m and lift upto 1.5m. |
| 4 | Supplying Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. |
| 5 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time andcreating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of buildingexpansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc.complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinthlevel :1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 7 | Random rubble dry stone Kharanja (soling) under floor. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing andreinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto twostories excluding cost of centring, shuttering, finishing and reinforcement : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair casesupto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) - (As per design mix) |
| 11 | Centring and shuttering upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete. |
| 12 | Centring and shuttering upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform. |
| 13 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 14 | Providing, hoisting and fixing upto two stories precast reinforced cement concrete in small lintels not exceeding 1.5m clear span upto two stories including the cost of required centring, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 15 | Providing, hoisting and fixing upto two stories precast reinforced cement concrete in lintels, beams and bressumers including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centring and shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 16 | Brick work with bricks of class designation 75 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 17 | Extra for brick work in superstructure above two stories for each two stories or part thereof by mechanical means by lifting material using mobile crane . |
| 18 | Half brick masonry with brick of class designation 75 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) |
| 19 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. |
| 20 | Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 21 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edgeto give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra blackmarble.Area of slab upto 0.50 sqm. |
| 22 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edgeto give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm. |
| 23 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed withpigment of matching shade complete. |
| 24 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 25 | Providing and laying polished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 60x60 cm |
| 26 | Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineerin-Charge. |
| 27 | Marble work |
| 28 | Granite Work |
| 29 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holesfor pillar taps etc. including rubbing and polishing of cut edges etc.complete. |
| 30 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 31 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 32 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3ply veneering with vertical grains or cross bands and face veneerson both faces of shutters : 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 33 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) |
| 34 | Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile -B |
| 35 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube. |
| 36 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted onspecially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixingnecessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. 80x1.25mm M.S. laths with 1.25 mm thick top cover. |
| 37 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :in 75x75mm deep chase |
| 38 | Painting top of roofs with bitumen of approved quality at 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : With residual type petroleum bitumen of penetration 80/100 |
| 39 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. |
| 40 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding theedge sand making and finishing the outlet complete. |
| 41 | Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick bats complete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification. |
| 42 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 43 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:6 (1 cement : 6 fine/ coarse sand) |
| 44 | 6 mm cement plaster on ceiling of mix : 1:3 (1 cement : 3 fine sand) |
| 45 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 46 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 47 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 48 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. |
| 49 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 50 | Providing and laying water proofing treatment to vertical andhorizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 51 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 52 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 53 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 54 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 260gms. |
| 55 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 265mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighting not less than 263gms. |
| 56 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38mm of 83mm length and 77mm breadth, weighing not less than 60gms. |
| 57 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 58 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms. |
| 59 | Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colour. Weighing not less than 88 gms. |
| 60 | Providing and fixing PTMT grating of approved quality and colour.125 mm nominal dia with 25 mm waste hole. |
| 61 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 62 | Providing and fixing PTMT swivelling shower, 15mm nominal bore.Weighing not less than 40gms. |
| 63 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc. 15 mm dia. nominal bore |
| 64 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.25 mm dia. nominal bore |
| 65 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall.15 mm dia nominal bore |
| 66 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work : 15mm dia nominal bore |
| 67 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work :25mm dia nominal bore |
| 68 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore |
| 69 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore |
| 70 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore. |
| 71 | Providing and fixing PTMT pillar cock of approved quality and colour 15mm nominal bore, 107mm long. Weighing not less than 110 gms. |
| 72 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 15 mm nominal bore, 105 mm long weighing not less than 138 gms. |
| 73 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 74 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 75 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 76 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 77 | P & F PVC Storage Tank (IS : 12701marked indicating the BIS license No), of approved makewith cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity. |
| 78 | Hoisting Charges for each floor :for item 34 |
| 79 | Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100mm dia |
| 80 | Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150mm dia |
| 81 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia S.W. pipe |
| 82 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 150mm dia S.W. pipe |
| 83 | Providing and fixing square-mouth S.W. gully trap grade \"A\"’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design :150 x 100 mm size P type. With bricks class designation 75 |
| 84 | Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150mm dia |
| 85 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With bricks with class designation 75 |
| 86 | Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 87 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With bricks |
| 88 | Providing and fixing soil, waste and vent pipes :75 mm diameter : Sand cast iron S&S pipe as per IS: 1729. |
| 89 | Providing and fixing soil, waste and vent pipes : 100 mm diaSand cast iron S&S pipe as per IS: 1729. |
| 90 | Providing and fixing single equal plain junction of required degree : 100x100x100 mm Sand cast iron S&S as per IS - 1729 |
| 91 | Providing and fixing single equal plain junction of required degree :75x75x75 mm Sand cast iron S&S as per IS - 1729 |
| 92 | Providing and fixing plain bend of required degree. 100 mm : Sand cast iron S&S as per IS - 1729 |
| 93 | Providing and fixing plain bend of required degree. 75 mm : Sand cast iron S&S as per IS - 1729 |
| 94 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm : Sand cast iron S&S as per IS - 1729 |
| 95 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75 mm : Sand cast iron S&S as per IS - 1729 |
| 96 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 100mm dia |
| 97 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 75 mm dia |
| 98 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles,18 SWG M.S.box with earthing terminal, 6 A switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. |
| 99 | Short point (up to 3 mtr.) |
| 100 | Medium point (up to 6 mtr.) |
| 101 | Long point(up to 10 mtr..) |
| 102 | Wiring of twin control light point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tles,18 SWG M.S.box with earthing terminal, 6 A two way switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. |
| 103 | Medium point (up to 6 mtr.) |
| 104 | Wiring of 3 pin 5 amp. light plug point with 1.5 sq. mmFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved makein surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, 18 SWG M.S.box with earthing terminal, 6 Aswitch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. |
| 105 | On board |
| 106 | Short point (up to 3 mtr.) |
| 107 | Medium point (up to 6 mtr.) |
| 108 | Long point(up to 10 mtr..) |
| 109 | ADD 20 % IN POINT WIRING RATE FOR USING PC SERIES MODULAR ACCESSORIES |
| 110 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall and making good the same as required. |
| 111 | 20 mm |
| 112 | 25 mm |
| 113 | 32 mm |
| 114 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. |
| 115 | 3x 1.5 sq.mm ( For Extra Long Points Above 10 Mtr) |
| 116 | 2 x 2.5 sq. mm. + 1x1.5sqmm ( For Light circuits) |
| 117 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. ( For Power Circuits) |
| 118 | 2 x 6.0 sq.mm + 1X2.5 Sq mm |
| 119 | 1 x 4.0 sq.mm ( for submain line from Main Panel To DBs) |
| 120 | 4 x 10.0 sq.mm ( for submain line from Main Panel To DBs) |
| 121 | Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned /annealed copper conductor taped &confirming to ITD specification S/WT-129C ofapproved make in existingsurface or recessed conduit/casing capping. (Group-2)Unarmoured |
| 122 | 2 pair (35 Points x 10 mtr each) |
| 123 | Jelly filled armoured(PIJF) |
| 124 | 10 pair |
| 125 | 20 pair (1 Submains x 30 mtr each) |
| 126 | P & F Krone type main distribution frame (MDF) in the recess/ surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly painted with 2 coat of red oxide paint & two coats of enamel paint (Group-I) |
| 127 | 10 pair |
| 128 | 20 pair |
| 129 | Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existingsurface or recessed conduit/casing capping including making connections as required (Group-2) |
| 130 | RG - 6 (9 Points x 10 mtr each) |
| 131 | RG - 11 |
| 132 | P & F following modular accessories made out of unbreakable and fire retadent poly carbonate with silver contacts including making connections teating etc as required.( Group 2) |
| 133 | 16 A one way switch |
| 134 | 16 A6 pin shuttered socket |
| 135 | RJ-11 telephone jack single two line |
| 136 | T.V. coaxial socket |
| 137 | 5 step fan regulator |
| 138 | Blanking plate |
| 139 | P & F following size mounting grid plates with cover plates. |
| 140 | 1-2 Module |
| 141 | 3 Module |
| 142 | 4 Module |
| 143 | P & F following size mounting grid plates with cover plates. |
| 144 | 1-2 Module |
| 145 | 3 Module |
| 146 | 4 Module |
| 147 | P&F 240/415 V MCB of breaking capacity not less than 10 KA (D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required Group-2. Single pole MCB |
| 148 | 6 A to 32 A rating |
| 149 | Four pole MCB |
| 150 | 6 A to 32 A rating |
| 151 | 40 A to 63 A rating |
| 152 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required Group-2. Double door (Three phase) |
| 153 | 4 Way |
| 154 | 8 Way |
| 155 | P&F of Heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaustfan,IS:2312 marked in existing opening including making connections testing etc. as required.(Group 2) |
| 156 | 300 mm sweep(900/1400 RPM) |
| 157 | P & F 1.6 mm thick M.S. Recessed fan box, hexagonal/ round of size 100 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . |
| 158 | P & F 3.0 mmPVC sheet for fan box with the help of screws, cup washer as required. |
| 159 | P & F double ball bearing capacitor start ceilingfan of approved make complete with regulator and other accessories as required. (for estimation purpose only) 1200 mm sweep |
| 160 | P & F box type fluorescent tube fittingfabricated from CRCA sheet and finished with powder coating / Stove enamelled Paintcomplete with accessories like (OCCB , starter , starter seat )/EB ,condensor,rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required.( without tube) Group-2 1 X 36 Watts with OCCB |
| 161 | P & F Fluorscent tube rod in existing fixtures as required .Group-2 Triphosphor Coated 36/40 Watts |
| 162 | P & F two pin energy efficient compact fluorscent lamp in existing holder/fixture as required.Group-2 |
| 163 | 11 watt |
| 164 | 13/18 watt |
| 165 | S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 8 SWG G I Wire [10 MTR X 3 FOR METER BODY, LT PANEL BODY & TELEPHONE EXCHANGE BODY ] |
| 166 | S & Laying following size\" A\" class G.I. Pipe with accessories for laying earth conductor/strip in ground/surface/recess as required 15mm dia[10 MTR X 3 FOR METER BODY, LT PANEL BODY & TELEPHONE EXCHANGE BODY ] |
| 167 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and brick masonary finished chamber covered with ferro cement coverC.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. [1 FOR METER BODY, 1 FOR LT PANEL BODY & 1 FOR TEL EXCHANGE BODY] |
| 168 | SITC of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of CRCA sheet , required hardware,duly painted by eithertwo coats of zinc/ red oxide primer followed by two coats of synthetic enamel paint or powder coatingin grey or required shade after rinsing . The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with detachable extension type structure. (only outer area on all sides shall be measured ) |
| 169 | Supplying and fixing of Aluminium / Copper bus barby means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolytic grade Aluminium bus bar |
| 170 | SITC of quick make and quick break4 POLEcurrent limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 13947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs / spreaders etc. as required Group 1 With Thermal Magnetic Release up to 100 Amp , 16/ 25kA, adjustable O/L & fixed S/C setting (100A-1NO.) |
| 171 | P&F 240/415 V MCB of breaking capacity not less than 10 KA (D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required Group-2. Four pole MCB |
| 172 | 6 A to 32 A rating |
| 173 | 40 A to 63 A rating |
| 174 | Supply and fixing of following accessories for MCCB |
| 175 | Under Voltage Release |
| 176 | S & F of (0-500 ) Volts Range Voltmeter on existing panel, making connections by PVC insulted copper condutor with PVC sleeves / Channel etc. as required Digital type |
| 177 | S & F of CT operated Direct Reading type Ampere meter on existing panel, making connections by PVC insulted copper condutor with PVC sleeves / Channel etc. as required Digital type |
| 178 | Below 500 A |
| 179 | SF of240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required. |
| 180 | Red/yellow/Green colour |
| 181 | Blue colour |
| 182 | SF ofCurrent Transformer, with all necessary support in existing panel including connection etc. as required . |
| 183 | up to 150 / 5 Ratio 5 VA , class 1 accuracy |
| 184 | S & F Selector Switch for Voltmeter (4 Position) including Making Connection Etc. as required |
| 185 | S & F of CT linked Selector Switch of 10 A for Ampere meter (4 Position) including Making Connection Etc. as required |
| 186 | SITC of self healing MPP/MP type shunt capacitor (banks) confirming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR . including making connections with suitable capacity conductors/cables testing as required. Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 187 | P & F of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors /reactors to limit the inrush current, confirming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.Up to 6 KVAR |
| 188 | P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. |
| 189 | Up to 14 Amp |
| 190 | 15 to 20 Amp |
| 191 | P & F push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Luminous type |
| 192 | P&F 240/415 V MCB of breaking capacity not less than 10 KA (D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required Group-I. Three pole MCB |
| 193 | 6 A to 32 A rating |
| 194 | 40 A to 63 A rating |
| 195 | SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. |
| 196 | Digital type |
| 197 | SF of CT operated direct reading typeAmpere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type |
| 198 | Below 500 A |
| 199 | SF ofCurrent Transformer, with all necessary support in existing panel including connection etc. as required . up to 150 / 5 Ratio 5 VA , class 1 accuracy |
| 200 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 1 x 4.0 sq.mm |
| 201 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 3.5 x 35.0 sq.mm |
| 202 | S/F cable route marker with 10cm x 10cm x 5mm thick or of 10cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 6mm angle iron,60cm long and fixing the same in ground as required |
| 203 | P, Laying and jointing of RCC class NP2 Non Pressure pipes ( IS:458) with collars Jointed with cement mortar of ratio 1:2 including excavation etc. as required 100 mm dia. Internal |
| 204 | Demolishing lime concrete and disposal of material within 50 meter lead |
| 205 | Demolishing cement concrete including disposal of material within 50 meters lead : 1 : 4 : 8 or leaner mix |
| 206 | Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead In cement mortar |
| 207 | Dismantling stone rubble masonry including stacking of serviceable material and disposal of unserficeable material within 50 meters leads In Cement mortar |
| 208 | Removing mortar from stones and cleaning stones and concrete articles including stacking (net quantity of stacks of cleaned materials will be measured) : Cement mortar |
| 209 | Dismantling doors, windows and clearstory windows (steel or wood) shutters including chowkhats, architrave and holdfasts etc. complete and stacking within 50 meters lead : |
| 210 | Of area 3 square meter and below |
| 211 | Of area beyond 3 square meter |
| 212 | Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead : |
| 213 | Of area 3 square meter and below |
| 214 | Of area beyond 3 square meter |
| 215 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead : For thickness of tiles, above 25mm and upto 40mm |
| 216 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 217 | Dismantling GI pipes (external work) including excavation and refilling trenches after taking out the pipes and including stacking of pipes within 50 meter lead : |
| 218 | 15mm to 40mm nominal bore |
| 219 | Above 40mm nominal bore |
| 220 | Dismantling CI pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into block, including stacking of pipes lead at site within 50 meter, of dia. Upto 150mm diameter |
| 221 | Dismantling chajja and shelves with care including making jhiries and making good : Katla Chajja |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail