| 1 | Name of items with specification |
| 2 | Digital multi-programmable pacemaker with lifetime warranty.Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA/RV. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF.1. With 7F compatible passive-fixation tined lead or screw-in lead & lead introducer.2. Pulse generator only. |
| 3 | Digital multi-programmable pacemaker with lifetime warranty,a. 1.5 Tesla MRIb. 3 Tesla MRI (full body)Mode: single chamber: VVIR/ AAIR. With dynamic adjustment ofpacing output and proven longevity of >10 years with 100% pacing of RA/RV. Digital high sampling rate of P/R wave and automatedventricular rate stabilization during AF.1. With 7F compatible passive-fixation tined lead or screw-in lead & lead introducer.2. Pulse generator only. |
| 4 | Digital multi-programmable pacemaker with lifetime warranty.Mode: Dual chamber VDD (with separate atrial and ventricular leads)With dynamic adjustment of pacing output and proven longevity of >10years with 100% pacing of RA/RV. With advanced features likeautomatic AV search, to minimize RV pacing.1. With 7F compatible passive-fixation tined lead or screw-in lead &lead introducers.2. Pulse generator only. |
| 5 | Digital multi-programmable pacemaker with lifetime warrantv.Mode: Dual chamber DDD. With dynamic adjustment of pacing outputand proven longevity of >10 years with 100% pacing of RA & RV. Withadvanced features like(i) automatic AV search (li) AV delay extendable upto 400 ms (ili) Ratehysteresis etc. to minimize RV pacing.1. With 7F compatible passive-fixation tined lead or screw-in lead & lead introducers2. Pulse generator only. |
| 6 | Digital multi-programmable pacemaker with lifetime warrantya. 1.5 Tesla MRIb. 3 Tesla MRI (full body)Mode: Dual chamber DDD. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV. With advanced features like(i) automatic AV search (ii) AV delay extendable upto 400 ms (iii) Rate hysteresis etc. to minimize RV pacing.1. With 7F compatible passive-fixation tined lead or screw-in lead & lead introducers.2.Pulse generator only. |
| 7 | Digital multi-programmable pacemaker with lifetime warranty.Mode: Dual chamber DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV.1. With 7F compatible passive-fixation tined lead or screw-in lead & lead introducers.2. Pulse generator only. |
| 8 | Digital multi-programmable pacemaker with lifetime warrantya. 1.5 Tesla MRIb. 3 Tesla MRI (full body)Mode: Dual chamber DDDR. With features of automatic thresholdcheck, auto adjusting of AV delay (extendable upto 400 ms), andautomatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV.1. With 7F compatible passive-fixation tied lead or screw-in lead &lead introducers.2. Pulse generator only. |
| 9 | Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Pulse generator only. |
| 10 | Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead.a. 1.5 Tesla MRI b. 3 Tesla MRI (full body)1. Device with all leads (passive tined or active screwing) andintroducers.2. Pulse generator only. |
| 11 | Biventricular cardiac resynchronization (CRT-P) device withQuadripola LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Pulse generator only. |
| 12 | Biventricular cardiac resynchronization (CRT-P) device withQuadripolar LV lead.a. 1.5 Tesla MRIb. 3 Tesla MRI (full body)1. Device with all leads (passive tined or active screwing) andintroducers.2. Pulse generator only. |
| 13 | Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Pulse generator only. |
| 14 | Combo device (CRT-D) with bipolar LV lead. |
| 15 | Combo device (CRT-D) with bipolar LV lead.a. 1.5 Tesla MRIb. 3 Tesla MRI (full body)1. Device with all leads (passive tined or active screwing) and introducers2. Device only. |
| 16 | Combo device (CRT-D) with bipolar LV lead. Less weight of approx = 75±5 gm and small volume of approx = 30±6 cc, possibility of =4 pacing vectors with bipolar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Device only. |
| 17 | Combo device (CRT-D) with bipolar LV lead.a. 1.5 Tesla MRI b. 3 Tesla MRI (full body)Less weight of approx =75±5 gm and small volume of approx = 30±6 cc, possibility of =4 pacing vectors with bipolar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Device only. |
| 18 | Combo device (CRT-D) with Quadripolar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Device only |
| 19 | Combo device (CRT-D) with Quadripolar LV lead.a. 1.5 Tesla MRIb. 3 Tesla MRI (full body)Device with all leads (passive tined or active screwing) and introducers.2. Device only |
| 20 | Combo device (CRT-D) with Quadripolar LV lead.Less weight (approx = 75±5 gm) and small volume (approx = 30±6cc), possibility of =15 pacing vectors with the Quadripolar LV lead.1.Device with all leads (passive tined or active screwing) andintroducers.2. Device only |
| 21 | Combo device (CRT-D) with Quadripolar LV lead.a. 1.5 Tesla MRIb. 3 Tesla MRI (full body)Less weight (approx =75±5 gm) and small volume (approx = 30±6cc), possibility of =15 pacing vectors with the Quadripolar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Device only |
| 22 | Combo device (CRT-D) with bipolar LV lead, with DF-4 connector of RV lead. Less weight (approx = 75±5 gm) and small volume (approx =30±6 cc), possibility of = 5 pacing vectors with the bipolar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Device only |
| 23 | Combo device (CRT-D) with bipolar LV lead, with DF-4 Connector of RV lead.a. 1.5 Tesla MRIb.3 Tesla MRI (full body)Less weight (approx = 75± 5gm) and small volume (approx = 30±6 cc), possibility of = 5 pacing vectors with the bipolar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Device only |
| 24 | Combo device (CRT-D) with Quadripolar LV lead, with DF-4 connector of RV lead.Less weight (approx < 75±5 gm) and small volume (approx = 30±6cc), possibility of =15 pacing vectors with the Quadripolar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Device only |
| 25 | Combo device (CRT-D) with Quadripolar LV lead, with DF-4 connector of RV leada. 1.5 Tesla MRIb. 3 Tesla MRI (full body)Less weight (approx = 75+5 gm) and small volume (approx = 30+6cc), possibility of =15 pacing vectors with the Quadripolar LV lead.1. Device with all leads (passive tined or active screwing) andintroducers.2. Device only |
| 26 | Combo device (CRT-D) with epicardial LV lead1. Device with all leads (passive tined or active screwing) andintroducers.2. Device onlv |
| 27 | Implantable cardioverter defibrillator: Single chamber1. Device with lead (passive tined or active screwing)2. Device only. |
| 28 | Implantable cardioverter defibrillator: Single chambera.1.5 Tesla MRIb. 3 Tesla MRI (full body)1. Device with lead (passive tined or active screwing)2. Device only. |
| 29 | Implantable cardioverter defibrillator: Single chamber with DE-4header.1.Device with lead (passive tined or active screwing) and introducers2. Device Only |
| 30 | Implantable cardioverter defibrillator: Single chamber with DF-4header.a. 1.5 Tesla MRIb. 3 Tesla MRI (full body)1. Device with lead (passive tined or active screwing) andintroducers.2. Device only. |
| 31 | Implantable cardioverter defibrillator: Dual chamber1. Device with lead (passive tined or active screwing) andintroducers.2. Device only. |
| 32 | Implantable cardioverter defibrillator: Dual chambera. 1.5 Tesla MRIb. 3 Tesla MRI1. Device with lead (passive tined or active screwing) andintroducers.2. Device only |
| 33 | Implantable cardioverter defibrillator: Dual chamberLess weight (approx. <60±5g) and small volume (approx. =25±5cc) with advanced feature of automatic AV search, adjustable AV delay etc.1. Device with lead (passive tined or active screwing) andintroducers.2. Device only |
| 34 | Implantable cardioverter defibrillator: Dual chamberLess weight (approx. <60±5g) and small volume (approx. <25±5cc) with advanced feature of automatic AV search, adjustable AV delay etc.a. 1.5 Tesla MRIb. 3 Tesla MRI (Full body)1. Device with lead (passive tined or active screwing) and introducers.2. Device only |
| 35 | Implantable cardioverter defibrillator: Dual chamber with DF-4 header. Less weight (approx. =60±5 g) and small volume (approx. =25±5cc) with advanced feature of automatic AV search, adjustable AV delay etc.1. Device with lead (passive tined or active screwing) and introducers.2. Device only |
| 36 | Implantable cardioverter defibrillator: Dual chamber with DF-4 header Less weight (approx. <60±5 g) and small volume (approx. =25±5cc) with advanced feature of automatic AV search, adjustable AV delay etc.a. 1.5 Tesla MRIb. 3 Tesla MRI (Full body)Device with lead (passive tined or active screwing) andintroducers.2. Device only |
| 37 | Subcutaneous ICD1. Device with lead and all accessories for implantation2. Device only |
| 38 | MRI compatible Subcutaneous ICD1.Device with lead and all accessories for implantation2. Device only |
| 39 | Permanent pacing leads (ventricular / atrial endocardial bipolar,passive fixation with tines), steroid luting, IS-1 header with theintroducer sheath |
| 40 | Permanent pacing leads (ventricular / atrial endocardial bipolar,passive fixation with tines), steroid luting, IS-1 header with theintroducer sheatha. 1.5 T MRIb. 3 T MRI (full body) |
| 41 | Permanent pacing leads (ventricular / atrial endocardial bipolar, active fixation with screw), steroid luting, IS-1 header with the introducer sheath. |
| 42 | Permanent pacing leads (ventricular / atrial endocardial bipolar, active fixation with screw), steroid luting, IS-1 header with the introducer Sheatha. 1.5 T MRIb. 3 T MRI (full bodv) |
| 43 | Unipolar. MRI compatible, epicardial permanent screw-in pacing lead. steroid luting, IS-1 header with the deploying kit. |
| 44 | Bipolar, MRI compatible, epicardial permanent screw-in pacing lead, steroid luting, IS-1 header with the deploying kit. |
| 45 | Only introducer kit for endocardial RA/RV/ICD leads (without leads), 6F, 7F, 8F. |
| 46 | Permanent defibrillation lead, bipolar, endocardia steroid elutingtipped, DF-1 header, with the introducer sheath/kit.1. Tinned2 Screw- In |
| 47 | Permanent defibrillation lead, bipolar, endocardial steroid elutingtipped, DF-1 header, with the introducer sheath/kit.a. 1.5 T MRIb. 3T MRI (Full body)1.Tinned2. Screw- In |
| 48 | Permanent defibrillation lead, bipolar, endocardia steroid elutingtipped, DF-4 header, with the introducer sheath/kit.1. Tinned2. Screw- In |
| 49 | Permanent defibrillation lead, bipolar, endocardial steroid elutingtipped, DF-4 header, with the introducer sheath/kit.a.1.5 T MRIb. 3T MRI (Full body)1 Tinned2. Screw- In |
| 50 | Bipolar endocardia LV lead with introducer kit. |
| 51 | Bipolar endocardial V lead with introducer kit.a. 1.5 T MRIb. 3T MRI (Full body) |
| 52 | Quadripolar endocardia LV lead with introducer kit. |
| 53 | Quadripolar endocardia V lead with introducer kit.a.1.5T MRIb. 3T MRI (Full body) |
| 54 | CS cannulation kit only (without LV lead) with all the accessories like sheath, puncture needle, syringe, 0.035\" long guide wire. |
| 55 | Special peel away long sheath for CS cannulation with Vein sub-selectors1. The CS sheath must be peel-away sheath and should be availablein all standard sizes and shapes2. The sheath should have a hemostatic valve3. The Vein sub-selectors should be available in all standard sizesand shapes |
| 56 | Special slittable long sheath for CS cannulation with Vein sub selectors1. The CS sheath must be slittable sheath and should be available inall standard sizes and shapes2. The sheath should have a hemostatic valve3. The Vein sub-selectors should be available in all standard sizesand shapes |
| 57 | External event recording of upto 1 week of arrhythmic events,portable, easy to operate with 1/3 lead system and easy operation by patient/relatives at home |
| 58 | Digital multiprogrammable very small VVIR pacemaker for pediatric endocardial implantation, = 15 gm weight with smallest size, small endocardial steroid eluting screw-in lead, 5F sheath compatible, with lifetime warranty1. Device with lead and all accessories2. Device only |
| 59 | Digital multiprogrammable very small VVIR pacemaker forneonatal/pediatric epicardial implantation, < 15 gm weight withsmallest size, with epicardial steroid eluting screw-in lead, with lifetime warranty1. Device with lead and all accessories2. Device only |
| 60 | Combo device (CRT-D) with Quadripolar lead having features ofmultisite pacing from LV lead.1. Device with all leads (passive tinned or active screw-in) andintroducers2. Device only |
| 61 | Combo device (CRT-D) with Quadripolar lead having features ofmultisite pacing from LV lead.a. 1.5 T MRIb. 3T MRI (Full body)1. Device with all leads (passive tinned or active screw-in) andintroducers2. Device only |
| 62 | Combo device (CRT-D) with Quadripolar lead having features ofmultisite pacing from LV lead. DF-4 RV lead.1. Device with all leads (passive tinned or active screw-in) andintroducers2. Device only |
| 63 | Combo device (CRT-D) with Quadripolar lead having features ofmultisite pacing from LV lead. DF-4 RV lead. Less weight (approx = 75±5 gm) and small volume (approx = 30±6 cc)a. 1.5 T MRIb. 3T MRI (Full body)1. Device with all leads (passive tinned or active screw-in) andintroducers2. Device only |
| 64 | Digital multi-programmable pacemaker with limited warranty for 10 years.Mode: single chamber: VVIR/AAIR. With dynamic adjustment ofpacing output. Digital High sampling rate of P/R wave and automatic\ ventricular rate stabilizing during AF.1. With 7F compatible passive-fixation tined lead or screw-in lead & lead introducer.2. Pulse generator only. |
| 65 | Digital multi-programmable pacemaker with limited warranty for 10 years.Mode: single chamber: VVIR/AAIR. With dynamic adjustment ofpacing output. Digital High sampling rate of P/R wave and automaticventricular rate stabilizing during AF.a 1.5 T MRIb. 3T MRI (Full body)1. With 7F compatible passive-fixation tined lead or screw-in lead &lead introducer.2. Pulse generator only. |
| 66 | Digital multi-programmable pacemaker with lifetime warranty.Mode: Dual chamber: DDDR With features of automatic thresholdcheck, auto adjustment of AV delay (extendable upto 400 ms),automatic intrinsic activity search, and ATP. With dynamic adjustmentof pacing output and proven longevity of > 10 years with 100% RA andRV pacinga. 1.5 T MRIb. 3T MRI (Full body)1. With 7F compatible passive-fixation tined lead or screw-in lead &lead introducer.2. Pulse generator only. |
| 67 | Implantable cardioverter defibrillator: VDD with single lead.1. Device with lead (passive tined or active screwing) and allaccessories2. Device onlv |
| 68 | Implantable cardioverter defibrillator: VDD with single lead.a. 3 Tesla MRI (full body)1. Device with lead (passive tined or active screwing) and allaccessories2. Device onlv |
| 69 | 3 T &/1.5 T full body MRI conditional multiprogrammable, Quadripolarlead, auto capture management for RA, RV and LV, automatic atrialanti-tachycardia therapies, heart failure diagnostics with transthoracicfluid impedance measurement and rate drop response,multisite/multipoint pacing CRT-P |
| 70 | 3 T &/1.5 T full body MRI conditional multiprogrammable, Quadripolarlead, auto capture management for RA, RV and LV, automatic atrialanti-tachycardia therapies, heart failure diagnostics with transthoracicfluid impedance measurement and rate drop response,multisite/multipoint pacing CRT-D |
| 71 | His bundle pacing systema. Complete system (Preshaped Delivery catheter) with Hisbundle leads (with and without Lumen)b. IPG onlyC. His bundle lead only |
| 72 | His Bundle Delivery catheter: Special deflectable His Bundle deliverycatheter with mapping electrodes and accessories. |
| 73 | Left Bundle Branch pacing systema. LBB lead with Preshaped delivery catheter of standard shapesand various lengthb. LBB lead with and without stylet only |
| 74 | Left bundle branch Delivery catheter: Special deflectable Left bundlebranch delivery catheter with mapping electrodes and accessories. |
| 75 | Digital multiprogrammable pacemaker with limited warranty.Mode: single chamber: VVIR/AAIR. With dynamic adjustment ofpacing output. Digital high sampling rate of P/R wave and automatedventricular rate stabilization during AF.1. With 7F compatible passive-fixation tined lead or screw-in lead &lead introducer.2. Pulse generator only. |
| 76 | Digital multiprogrammable pacemaker with limited warranty.Mode: single chamber: VVIR/AAIR. With dynamic adjustment ofpacing output. Digital high sampling rate of P/R wave and automatedventricular rate stabilization during AF.a. 1.5 T MRI b. 3T MRI (Full body)1.With 7F compatible passive-fixation tined lead or screw-in lead &lead introducer.2. Pulse generator only. |
| 77 | Implantable cardioverter defibrillator: single chamber. With warranty=10 years1Device with lead (passive tined or active screwing) and allaccessories2. Device onlv |
| 78 | Implantable cardioverter defibrillator: single chamber, MRI compatible.With warranty =10 years1. Device with lead (passive tined or active screwing) and allaccessories2. Device only |
| 79 | Implantable cardioverter defibrillator: dual chamber. With warranty >8years1. Device with lead (passive tined or active screwing) and allaccessories2. Device only |
| 80 | Implantable cardioverter defibrillator: dual chamber. MRI compatible.With warranty = 8years1. Device with lead (passive tined or active screwing) and all accessories2. Device only |
| 81 | Combo device (CRT-D) with Quadripolar LV lead. Warranty for = 6years1. Device with lead (passive tined or active screwing) and allaccessories2. Device only |
| 82 | Combo device (CRT-D) with Quadripolar LV lead. Warranty for = 6years. MRI compatible1. Device with lead (passive tined or active screwing) and all accessories2. Device only |
| 83 | Leadless Pacemaker: for AV synchronous Pacing with Delivery system3T MRI - Full body compatibleAt least 7 years Replacement warranty policy. |