Jaipur Metro Rail Corporation Limited-JMRC has published Supply, Installation, Testing And Commissioning Of Led Lights With Replacement Of Existing Old Faulty Conventional Lights At Various Locations Both Rss, Elevated Stations, Cdpe , Depot Of Jmrc. Supply, Installation, Testing And Commissioning Of Led. Submission Date for this Tender is 28-04-2022. Hooks Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | (For Mansarovar Depot) Supply of LED High Bay Light Fixture 200 watt with replacement of existing Old faulty INBY 400 watt light fixture. Specification:- Die cast aluminium housing offering lumen intensity >130 Lm/W, product lumen output 26000 1m, heat sink, surge protection 5.0 Kv internal, external 10 Kv spd, operating Voltage range 140-270 V, operating temp rang – 10 to 50 VDC, rated current <0.880 amp, power factor > 0.85, driver efficiency>85%, protection IP-65. Make: Bajaj,philips,Jaquar,Crompton,HPL or OEMhaving its own in house NABL lab setup for all facilitiesfor LED Fixture. Minimum Warranty: 2 years. |
2 | (For Mansarovar Depot) Supply of 25 watt LED pit Light (street light) Fixture with replacment of 2*18 watt existing oldfaulty conventional light fixture.Lumen Efficacy(Lm/W)=100 Make: Bajaj,philips,Jaquar,Crompton,HPL or OEMhaving its own in house NABL lab setup for all facilitiesfor LED Fixture. Minimum Warranty: 2 years. |
3 | (For Mansarovar Depot) Installation, Testing and Commissioninig for replacement of existing oldfaultylight fixture (Item No. -01) and installation ofNew LED 200 watt high bay fixtures including crane rent |
4 | (For Both RSS,Elevated Metro Stations and CDPE Metro station) Replacementof existingBAJAJ make 2X36 watt/36 Watt FTL(T8)(Thorn) oldfaultyconventional light into compatible 18/20 Watt LED Tube light T8 retro with Aluminium housing having 100 lm/watt with polycarbonate diffuser, THD <10%,Power Factor >0.95, IP 20, overvolatge protection upto 300V (20min), Surge protection 3 Kv,Operating temp -10 to 50 Degree. Make: Bajaj,philips,Jaquar,Crompton,HPL or OEMhaving its own in house NABL lab setup for all facilitiesfor LED Fixture. Minimum Warranty: 2 years |
5 | Installation, Testing & Commissioning charges of Item at sr. no. 4, including making connection & dismantling of old conventional lights |
6 | (For Elevated Metro Station) Supply of 30W LED flood light (complete fixture with all required accessories) in replacement ofexisting old faulty Thorn Make SPAK 70W light, Lumen Efficacy (Lm/W)= 100, Pressure die cast Aluminium housing, IP 65 Protection, Make: Bajaj,philips,Jaquar,Crompton,HPL or OEMhaving its own in house NABL lab setup for all facilitiesfor LED Fixture. Minimum Warranty: 2 years |
7 | (For Elevated Metro Station) Supply of 70W LED flood light (complete fixture with all required accessories) in replacement of existingold faulty Thorn Make SPAK 150W light, Lumen Efficacy (Lm/W)= 100, Pressure die cast Aluminium housing, IP 65 Protection, Make:Bajaj,philips,Jaquar,Crompton,HPL or OEM must have its own in house NABL lab setup for all facilities for LED Fixture. Minimum Warranty: 2 years |
8 | (For Both RSS and Elevated Metro Stations) Replacement of BAJAJ make 2X28 watt/AQFC-254(2*54Watt)(Make:Thorn) old faulty conventional light into compatible LED Batten 35W with Aluminium housing having 117 lm/watt with polycarbonate diffuser, THD <10%,Power Factor >0.95, IP 20, overvolatge protection upto 300V (20min), Surge protection 3 Kv,Operating temp -10 to 50 Degree. Make: Bajaj,philips,Jaquar,Crompton,HPL or OEMhaving its own in house NABL lab setup for all facilitiesfor LED Fixture. Minimum Warranty: 2 years. |
9 | (For Both RSS) Replacement of existing faulty BAJAJ make 150 WATTS MERCURY HALLIDE LAMP into compatible LED Light of Aluminium die cast LED70 W LED HIGHBAY EXCELLENT THERMAL MANAGEMENT WITH COMPACT HEAT SINK IP66 having 100lm/watt with clear diffuser, lens with toughened glass THD <10%,Power Factor >0.95, overvolatge protection upto 300V (20min), Surge protection 5 Kv internal & 10kv external ,Operating temp -10 to 50 Degree. Make: Bajaj,philips,Jaquar,Crompton,HPL or OEMhaving its own in house NABL lab setup for all facilitiesfor LED Fixture. Minimum Warranty: 2 years. |
10 | (For CDPE) Replacement of old faulty M type fixture (2*18) with LED lights fixture (15 watt,180*180mm square size),Lumen Efficacy(Lm/W)=100 Make: Bajaj,philips,Jaquar,Crompton,HPL or OEMhaving its own in house NABL lab setup for all facilitiesfor LED Fixture. Minimum Warranty: 2 years. |
11 | (For Both RSS,Depot and CDPE) Replacement of existingold faulty 54 watt Boom type/28*2 wattlights with LED 18-28 watt,T-5, Lengh-4 Feet long with Extructed aluminium housing including suitable hodlers.Lumen Efficacy(Lm/W)=100. Make: Renesola,pyrotech or OEM having its own in house NABL lab setup for all facilities for LED Fixture. Minimum Warranty: 2 years. |
12 | (for CDPE) Replacement of existing OLD faulty 36 watt,T-8,Old Conventional lights with LED 18/20 watt batten. Make: Bajaj,philips,Jaquar,Crompton,HPL or OEMhaving its own in house NABL lab setup for all facilitiesfor LED Fixture. Minimum Warranty: 2 years. |
13 | P&F of M.S. J-hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail